← All vessels
PINDOS
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named PINDOS
PINDOS is a 1977 freight ship. The Coast Guard has recorded 16 inspections since 1985, most recently in June 2001, along with 18 deficiencies and 3 operational controls.
Records from 1985 to 2001. Most recent: operational control imposed, 15 June 2001.
- Built
- 1977
- Last inspected
- 15 June 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7533109 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HFP6
251978
Flag
PANAMA
—
Maury page id
psix-251978
Inspections, by type
…with no type recorded16
Years with a record
11 calendar years (1985–2001)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it14420 - Regulatory (Subpart C or D), Net Ton
23627 - Regulatory (Subpart C or D), Gross Ton
38931 - Dead Weight, Ton
23627 - Regulatory (Subpart C or D), Gross Ton
38931 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
15 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291049
17 August 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 281333
15 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429710
7 May 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 415943
24 April 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 415147
11 September 1996
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 395335
1 February 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 387239
13 January 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 374064
1 February 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 341756
21 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 333798
6 March 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 328837
22 June 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 316905
30 August 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 311126
1 August 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 444410
22 January 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 466734
24 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 303136
Deficiency record · 18
Electrical
Issued 15 June 2001
Resolved
Fresh water cooling pump on #3 SS Generator leaking excessively. _x001C_(SOLAS 60/I/REG 11). Make permanent repairs to the satisfaction of the safety construction certificate issuing authority, prior to departure.
Electrical
Issued 15 June 2001
Resolved
Raw water cooling line leading to air cooler wasted, rendering the #1 SS Generator inoperable. (SOLAS 60/I/REG 11). Make permanent repairs to the satisfaction of the safety construction certificate issuing authority priorto departure.
Lifesaving
Issued 24 April 1998
Resolved
Remove open oil containments in steering gear and engine room.
Navigation
Issued 24 April 1998
Resolved
Place cotter pins or double nuts in steering gear. (Missing)
Lifesaving
Issued 24 April 1998
Resolved
Remove oil on deck in steering gear room.
Accommodation/Occupational Safety
Issued 24 April 1998
Resolved
Place grating or other nonslip surface in steering gear room. (Missing)
Navigation
Issued 24 April 1998
Resolved
Update charts. (Missing Notice to Mariners Information)
Navigation
Issued 24 April 1998
Resolved
Update C.G. Light List. (Missing 1998)
Accommodation/Occupational Safety
Issued 24 April 1998
Resolved
Clean vent in galley.
Navigation
Issued 24 April 1998
Resolved
Make repairs to magnetic compass. (14 degree error)
Documentation
Issued 24 April 1998
Resolved
Certificate of Financial Responsiblity not onboard. (VALID C.O.F.R. 846273-10)
Navigation
Issued 24 April 1998
Resolved
Make repairs to ARPA and provide tech. report. (inoperative)
Deck/Cargo
Issued 13 January 1995
Resolved
NO MECHANICAL MEANS FOR PLUGGING CONTAIMENT ON DECK
Fire Fighting
Issued 13 January 1995
Resolved
FIRE NOZZLES INOP THROUGHOUT SHIP DUE TO LACK OF MAINTENANCE. (SOLAS CHP II-2 REG 21.)
Navigation
Issued 13 January 1995
Resolved
A LETTER OF DEVIATION WAS ISSUED TO ENTER THE PORT OF LAKE CHARLES, WITH ANINOP RADAR.
Electrical
Issued 13 January 1995
Resolved
SWITCHBOARD ROOM AND EMERGENCY BATTERY ROOM MISSING SUITABLE GROUNDING DECKMATERIAL. (SOLAS CHP II-1 REG 40.1.3)
Documentation
Issued 13 January 1995
Resolved
NO MAINTENANCE RECORD OF LIFESAVING APPLIANCES (SOLAS CHP III REG 52)
Navigation
Issued 30 August 1986
Resolved
THERE WERE NO CORRECTED U.S. CHARTS 12311 AND 12312 OR A FOREIGN EQUIVALENTON BOARD THE VESSEL