MAURY USCG vessel records Sign in
← All vessels

PINDOS

PINDOS is a 1977 freight ship. The Coast Guard has recorded 16 inspections since 1985, most recently in June 2001, along with 18 deficiencies and 3 operational controls.

Records from 1985 to 2001. Most recent: operational control imposed, 15 June 2001.

Built
1977
Last inspected
15 June 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7533109 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
251978
Flag
PANAMA
—
Maury page id
psix-251978

Inspections, by type

…with no type recorded16
Years with a record 11 calendar years (1985–2001)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14420 - Regulatory (Subpart C or D), Net Ton
23627 - Regulatory (Subpart C or D), Gross Ton
38931 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

15 June 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291049
17 August 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 281333
15 June 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429710
7 May 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 415943
24 April 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 415147
11 September 1996 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 395335
1 February 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 387239
13 January 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 374064
1 February 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 341756
21 November 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 333798
6 March 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 328837
22 June 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 316905
30 August 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 311126
1 August 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 444410
22 January 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 466734
24 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 303136

Deficiency record · 18

Electrical
Issued 15 June 2001 Resolved
Fresh water cooling pump on #3 SS Generator leaking excessively. _x001C_(SOLAS 60/I/REG 11). Make permanent repairs to the satisfaction of the safety construction certificate issuing authority, prior to departure.
Condition: Unknown
Due 15 June 2001
Resolved 17 June 2001
Electrical
Issued 15 June 2001 Resolved
Raw water cooling line leading to air cooler wasted, rendering the #1 SS Generator inoperable. (SOLAS 60/I/REG 11). Make permanent repairs to the satisfaction of the safety construction certificate issuing authority priorto departure.
Condition: Unknown
Due 15 June 2001
Resolved 17 June 2001
Lifesaving
Issued 24 April 1998 Resolved
Remove open oil containments in steering gear and engine room.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Navigation
Issued 24 April 1998 Resolved
Place cotter pins or double nuts in steering gear. (Missing)
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 24 April 1998 Resolved
Remove oil on deck in steering gear room.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 24 April 1998 Resolved
Place grating or other nonslip surface in steering gear room. (Missing)
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Navigation
Issued 24 April 1998 Resolved
Update charts. (Missing Notice to Mariners Information)
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Navigation
Issued 24 April 1998 Resolved
Update C.G. Light List. (Missing 1998)
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 24 April 1998 Resolved
Clean vent in galley.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Navigation
Issued 24 April 1998 Resolved
Make repairs to magnetic compass. (14 degree error)
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Documentation
Issued 24 April 1998 Resolved
Certificate of Financial Responsiblity not onboard. (VALID C.O.F.R. 846273-10)
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Navigation
Issued 24 April 1998 Resolved
Make repairs to ARPA and provide tech. report. (inoperative)
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Deck/Cargo
Issued 13 January 1995 Resolved
NO MECHANICAL MEANS FOR PLUGGING CONTAIMENT ON DECK
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Fire Fighting
Issued 13 January 1995 Resolved
FIRE NOZZLES INOP THROUGHOUT SHIP DUE TO LACK OF MAINTENANCE. (SOLAS CHP II-2 REG 21.)
Condition: Unknown
Due 13 January 1995
Resolved 29 January 1995
Navigation
Issued 13 January 1995 Resolved
A LETTER OF DEVIATION WAS ISSUED TO ENTER THE PORT OF LAKE CHARLES, WITH ANINOP RADAR.
Condition: Unknown
Due 14 January 1995
Resolved 29 January 1995
Electrical
Issued 13 January 1995 Resolved
SWITCHBOARD ROOM AND EMERGENCY BATTERY ROOM MISSING SUITABLE GROUNDING DECKMATERIAL. (SOLAS CHP II-1 REG 40.1.3)
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Documentation
Issued 13 January 1995 Resolved
NO MAINTENANCE RECORD OF LIFESAVING APPLIANCES (SOLAS CHP III REG 52)
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996
Navigation
Issued 30 August 1986 Resolved
THERE WERE NO CORRECTED U.S. CHARTS 12311 AND 12312 OR A FOREIGN EQUIVALENTON BOARD THE VESSEL
Condition: Unknown
Due 2 February 1996
Resolved 2 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.