MAURY USCG vessel records
← All vessels

SUPER CHIC

SUPER CHIC is a 1984 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in May 2025, along with 31 deficiencies and 1 casualty investigation in 2002.

Records from 2002 to 2025. Most recent: inspection, 12 May 2025.

Built
1984
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE9205
252075
Flag
UNITED STATES
Maury page id
psix-252075

Documentation record

Registered dimensions (L × B × D)55.7 ft × 16.7 ft × 7.5 ft
Registered tonnagegross 48 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBBINS BOAT BLDRS INC · CAMBRIDGE, MD, UNITED STATES · built 1984
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPARKERTOWN, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
39 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

12 May 2025 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8132966
27 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8085441
25 July 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7966583
20 June 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7938963
16 April 2024 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7896375
11 August 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7765575
8 June 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7709889
6 April 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7664026
5 January 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7616815
16 September 2022 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7548010
9 July 2022 Type not recorded
No type recorded · USCGC ROLLIN A. FRITCH (WPC 1119) · USCG East District (CGD-E) · Activity 7504354
25 May 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7459200
14 October 2021 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7334687
13 April 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7174076
1 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7167138
2 March 2020 In-Service Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6919256
1 May 2019 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6674593
10 April 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6660006
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505600
15 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6389353
28 March 2017 Administrative Inspection · Examination of Repairs · Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6155987
29 March 2016 Hull Examination · Deficiency Check · DAPI Audit · Annual Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5842524

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2024 Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection. STBD M/E Raycor fuel filter had diesel fuel in flame shield bowl. Remove excessive fuel from flame shield. 46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 25 July 2024
Resolution: Repairs completed to fuel filter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2024 Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection. STBD propulsion shaft seal had excessive leak. Repair to the satisfaction of the attending Marine Inspector. 46CFR182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 25 July 2024
Resolution: Repairs completed to STBD shaft seal
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. Generator windings are saturated with oil and dirt. Clean windings to the satisfaction of attending marine inspector. 46 CFR 183.200(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2023
Resolved 11 August 2023
Resolution: Verified generator windings cleaned during follow on inpsection 11AUG23
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2023 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicator was not at operating station. Install indicator to the satisfaction of the attending inspector. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 11 August 2023
Resolution: verified visual indicator installed at operating station during follow on exam 11AUG23. Conducted operational test. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 June 2023 Resolved
A vessel on an oceans route must carry six hand orange smoke distress signals approved in accordance with § 160.037. Vessel is missing 03 orange smoke distress signals. Replace signals. 46 CFR 180.68(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2023
Resolved 11 August 2023
Resolution: Verified 03 smoke flares were put into service during follow on exam 11AUG23
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 June 2023 Resolved
Interim rule will add a new provision prohibiting avenues of escape that are located directly above, or dependent on, a berth for vessels with overnight. Egress depends of berth to escape. Submit plans to move egress route to [email withheld]. 46 CFR 177.500 IFR
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 11 June 2024
Resolution: Approved plans for modification.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 September 2022 Resolved
The waterlight required by 46 CFR 180.70(d)(3) was not working, O/O replaced battery, opp test sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 September 2022
Resolved 16 September 2022
Resolution: O/O replaced battery, opp test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 25 May 2022 Resolved
Identified accumulation of oily water in E/R bilge. Clean bilge prior to carriage of passengers. 46 CFR 176.830(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2022
Resolved 1 June 2022
Resolution: e/r bilge cleaned and dry
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 25 May 2022 Resolved
Identified expired FCC safety radio certificate. Vessel restricted to 1000 feet from shore. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 25 May 2022
Resolved 31 May 2022
Resolution: o/o provided valid FCC safety radio cert.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 April 2021 Resolved
Emergency escape hatch must be marked on both sides. Deck side emergency escape hatch must be marked "EMERGENCY EXIT, KEEP CLEAR" in two inch block letters. 46 CFR 185.30-25.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 22 April 2021
Resolution: Owner stenciled "Emergency Exit Keep Clear" in red block letters. Verified via photo.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 April 2021 Resolved
Provide proof of consortium MIS report and random testing for 2020.46 CFR 16.230 and 16.500.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 22 April 2021
Resolution: O/O emailed over proof of 2021 enrollment in consortium as well as random drug testing and MIS report for 2020.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 March 2020 Resolved
Adequate emergency lighting automaticallu acturated on failure of the main lighting system shall be fitted along the line of escape. 46 CFR "Old T" 184.30-5. 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2020
Resolved 4 May 2020
Resolution: Owner provided photos of newly installed, off the shelf e,ergency lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 March 2020 Resolved
Install plugs on bottom of petcocks on main engine racor fuel strainers. 46 CFR "Old T" 182.20-40. 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2020
Resolved 4 May 2020
Resolution: Owner provided photos of installed plugs.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 May 2019 Resolved
Prove proper operation of all visual bilge alarms. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2019 Resolved
Prove proper operation of forepeak bilge valve. 46 CFR 182.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 3 October 2019
Resolution: Made owner aware of the deficiency and he will double check the AIS broadcast info the next time he's on the vessel.
Lifesaving › Hand Flares › Expired
Issued 15 May 2018 Resolved
Need to replace 1 expired flare
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 17 May 2018
Resolution: Vessel's owner provided photo documentation of newly purchased hand flares. Vessel has correct amount (6 day and 6 night) of distress signals on board.
Fire Fighting › Ventilation Systems › Ducts
Issued 1 June 2017 Resolved
RT01: Engine Room is protected by a fixed gas extinguishing system and has no way to close ventilation. 46 CFR 182.465 (h) Prior to carry passengers.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 2 June 2017
Resolution: [name withheld] cleared via email
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 28 March 2017 Resolved
RT02: Alternator installed on port engine is an exposed hazard that requires a guard. 46 CFR 177.960 Due in 30 days, 01 July 2017
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 1 December 2017
Resolution: Owner provided pictures of new guard over alrernator
Construction/Loadline › Hull › Side Shell
Issued 9 June 2016 Resolved
Stbd stem and port chine log are leaking in the forepeak. Make watertight, including proper submission of repair plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2016
Resolution: Conducted satisfactory underway checkride to verify no water was leaking. The vessel was hauled and fiberglassed in the bow area with woven roven and West eopxy.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 June 2016 Resolved
Collision bulkhead is leaking water at the bottom. Submit repair plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2016
Resolution: Filled forepeak with approximately one foot of water to verify bulkhead is tight. The bulkhead/bottom shell joint was cleaned and glassed with West epoxy and woven roven.
Engineering › Bilge Water Management System › Valve
Issued 9 June 2016 Resolved
Install check valve in lazarette bilge piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 20 June 2016
Resolution: Check valve installed and laz suction verified.
Construction/Loadline › Hull › Keel
Issued 9 June 2016 Resolved
Keel underneath rudder posts in the lazarette has deep rot. Submit plan to repair and crop to good wood for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Verified proper repairs made.
Construction/Loadline › Hull › Transverse Frame
Issued 9 June 2016 Resolved
Rotted deck beams in port and stbd outboard sides of passengers cabin. Crop to good and make available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 1 December 2016
Resolution: Verified proper repair made.
Communications › Radio Communications › EPIRB
Issued 9 June 2016 Resolved
Mark hydrostatic release expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2016
Resolution: Corrected on the spot.
Engineering › Bilge Water Management System › Hose
Issued 9 June 2016 Resolved
Flex hoses in bilge system in 2nd compartment need additional hose clamps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 August 2016
Resolution: Verified additional hose clamps installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2016 Resolved
Remove dead end wire in lazarette.
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 20 June 2016
Resolution: Wire removed.
Engineering › Bilge Water Management System › Hose
Issued 9 June 2016 Resolved
Bilge pump discharge hose must meet SAE J-1942 with approved fittings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 3 August 2016
Resolution: Approved hose and fittings installed.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 June 2016 Resolved
Provide updated Coast Pilot for operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 20 June 2016
Resolution: Updated Coast Pilot on board.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 9 June 2016 Resolved
Install smoke detector that meets UL217 in overnight accommodation space prior to overnight trips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 June 2016
Resolution: Battery smoke detector installed.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 June 2016 Resolved
Hydraulic flex hose penetrates required collision bulkhead. Piping must be metallic when crossing a watertight bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 3 August 2016
Resolution: Installation accepted by OCMI.

Casualty record · 1

7 July 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1664773
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record