DAYDREAMER

DAYDREAMER is a 2001 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 2001, most recently in March 2026, along with 73 deficiencies, 3 operational controls and 3 casualty investigations between 2005 and 2024.

Records from 2001 to 2026. Most recent: inspection, 4 March 2026.

Built
2001
Last inspected
4 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK2410
Flag
UNITED STATES
368032650, 368035210
Maury page id
psix-25211

Inspections, by type

…with no type recorded5
Years with a record 24 calendar years (2001–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 27.0 ft × 7.5 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE TECHNOLOGIES · CHARLESTON, SC, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portST JOHN, VI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 24 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK2410MMSI 368035210 · active · compulsorily equipped · granted 2 May 2018, expires 2 May 2028
WDK2129MMSI 368032650 · active · voluntarily equipped · granted 13 April 2018, expires 13 April 2028
WDG4146MMSI 367533460 · expired · compulsorily equipped · granted 2 June 2012, cancelled 6 August 2022
WDA8405MMSI 366853990 · expired · compulsorily equipped · granted 23 May 2002, cancelled 28 July 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

4 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8321182
20 February 2026 COI Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8307895
14 December 2025 Type not recorded
No type recorded · Boat Forces Unit United States Virgin Islands · USCG Southeast District (CGD-SE) · Activity 8284103
22 July 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8198545
18 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8190058
20 February 2025 MTSA/ISPS Verification · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8082165
23 July 2024 Administrative Inspection · In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7999981
27 March 2024 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7910052
5 March 2024 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7885215
20 February 2024 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7850821
25 July 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7778595
27 February 2023 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7636637
18 August 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7546524
2 March 2022 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7403890
20 August 2021 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7292266
18 February 2021 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7176294
6 August 2020 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7090958
20 February 2020 DAPI Audit · Annual Inspection · MTSA/ISPS Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6912032
23 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6840682
8 August 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6809354
22 February 2019 DAPI Audit · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6620447
29 November 2018 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6588880
15 August 2018 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6513121
22 May 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6420329
26 February 2018 Deficiency Check · MTSA Verification · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6357878
5 December 2017 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6318697
12 September 2017 Examination of Repairs · Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6264840
28 March 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6113540
21 February 2017 MTSA/ISPS Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6091640
6 September 2016 Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5993143
26 February 2016 Deficiency Check · MTSA/ISPS Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5822404
3 September 2015 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5233334
22 May 2014 DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4933206
14 March 2014 DAPI Audit · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4815904
20 September 2011 Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4150215
28 July 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4096842
22 September 2010 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3870419
9 March 2010 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3692257
19 February 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3682222
11 March 2009 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3431378
31 October 2008 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3360405
17 March 2008 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3161610
4 September 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3065611
16 March 2007 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2886119
21 February 2007 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2875038
25 September 2006 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2808451
3 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2639193
13 March 2006 COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2601223
16 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586663
14 September 2005 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2492102
3 August 2005 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2455673
18 April 2005 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2336210
14 April 2005 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2333576
14 March 2005 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2309467
20 September 2004 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2200006
16 June 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2099994
7 May 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2061574
15 March 2004 COI Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2024448
6 March 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2019432
9 February 2004 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2009317
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999542
4 December 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1960310
19 May 2003 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1803611
11 March 2003 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1755140
11 December 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1720084
1 July 2002 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1639347
11 March 2002 Initial Certification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1492638
6 March 2002 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1491745
21 August 2001 Initial Construction-Excluding Oversight
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1410643

Deficiency record · 73

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 February 2024 Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the Commandant.**HRU expired.** 46 CFR 180.130(b)
Action required: 10 - Deficiency Rectified
Due 20 February 2024
Resolved 20 February 2024
Resolution: HRU replaced and installed new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. **Replace missing PORT ME vent closure device. 46 CFR 176.804
Action required: 10 - Deficiency Rectified
Resolved 20 February 2024
Resolution: Vent cover located and back in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. **Port main engine shift and throttle cable fittings/mounts/cotter pins corroded. Replace in-kind** 46 CFR 176.804
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 24 March 2024
Resolution: CIV [name withheld] cleared deficiency.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems.**Repair steering system leaks in the following locations: Helm, STBD steering gear space cylinder, PORT steering gear space pipe fittings. 46 CFR 176.804
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 24 March 2024
Resolution: CIV [name withheld] cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 February 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. **STBD ME Fireboy override control at the operating station won't start the ME unless the override control and engine start button are pressed in tandem. Provide documentation from manufacturer that this function by design or replace control and demonstrate operation for attending MI's. 46 CFR 176.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 24 March 2024
Resolution: CIV [name withheld] cleared deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. **STBD overhead deck hatch will not close.** 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 24 March 2024
Resolution: CIV [name withheld] cleared deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 February 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. **PORT forward lower lifeline damaged. Replace or repair for reinspection.** 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 21 March 2024
Resolution: Verified satisfactory replacement of port forward lower lifeline course.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 20 February 2024 Resolved
SMS Annual Internal Audit not conducted in 2023. SOLAS IX/4.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 24 March 2024
Resolution: CIV [name withheld] cleared deficiency.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 February 2024 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.**Provide current covered employee list.** 46 CFR 16.210
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 21 March 2024
Resolution: Verified current covered employee list.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2024 Resolved
All inspected sailing vessel owner/operators should have a written Preventive Maintenance Plan (PMP) that specifically addresses their vessel’s sail rigging equipment and components. PMP not on board vessel. Provide PMP for the DAYDREAMER to USCG MI's for review within 30 days. 46 CFR 176.802(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 24 March 2024
Resolution: CIV [name withheld] cleared deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 March 2022 Resolved
Forward port deck hatch is damaged and no longer weather tight due to cracks. Replace weathertight hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 18 August 2022
Resolution: Hatch previously replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 March 2022 Resolved
Vessel operator requested to change the vessel route to resume international service. Inspectors attended the vessel on 02MAR2022 to conduct an international T-boat COI inspection. The vessel is Restricted to Domestic Route only until the following items are provided and CG inspectors attend vessel for verification reinspection: 1. 03 life floats not on board in float free condition.
Action required: 702 - Prior to embarking on international voyage
Due 8 March 2022
Resolved 2 March 2022
Resolution: Verified IBAs onboard to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 October 2019 Resolved
Effective November 1st, 2019, all life floats will be required to be replaced by approved inflatable liferafts or inflatable buoyant apparatuses (IBAs) to comply with IMO SLS.14/Circ. 87 of 1989 for 100% of passengers onboard. Pending the decision results from USCG HQ to your waiver request for the carriage of IBA lifesaving appliances, this requirement will otherwise be due on 01 January 2020. Additional time may be granted pending the results of the decision by USCG HQ. If disapproved, a reasonable amount of time to acquire necessary IBAs may be granted as approved by the OCMI.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 20 February 2024
Resolution: Vessel removed life floats and replaced with an IBAs Returning to life floats for international service is not authorized.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 February 2019 Resolved
Provide current flares. 06 red handheld flares expired.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2019
Resolved 22 February 2019
Resolution: Vessel purchased 6 additional flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 February 2019 Resolved
Condemned 42 out of 53 adult type 1 PFDs due to foam degradation. Provide 53 serviceable adult PFDs.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2019
Resolved 22 February 2019
Resolution: Vessel provided additional PFDs reallocated from out of service vessels.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 February 2019 Resolved
Stern light inoperable. Show proper operation of stern light.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2019
Resolved 22 February 2019
Resolution: Vessel repaired sternlight and showed proper operation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 February 2019 Resolved
Aspirin and eyewash expired in first aid kit. Provide current and complete first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2019
Resolved 26 February 2019
Resolution: Vessel provided new aspirin and eyewash.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 February 2019 Resolved
Provide FCC Safety Radio Telephony certificate bearing correct call sign.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2019
Resolved 26 February 2019
Resolution: Vessel provided revised FCC SRC
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 February 2019 Resolved
Show proper operation of port pre-engineered fixed firefighting system (Fireboy) override.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2019
Resolved 26 February 2019
Resolution: Vessel replaced override switch and demonstrated proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2019 Resolved
Provide portable bilge pump suitable for all spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2019
Resolved 26 February 2019
Resolution: Vessel purchased bilge pump with longer hose.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 February 2019 Resolved
Replace expired EPIRB hydrostatic release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2019
Resolved 26 February 2019
Resolution: Vessel installed new hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 August 2018 Resolved
Replace/repair painter line holder and properly assemble the line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2018
Resolution: Renewed.
Communications › Visual Communication › Red Warning Signal
Issued 26 February 2018 Resolved
Provide required distress signals (flares).
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2018
Resolved 1 March 2018
Resolution: All new flares provided on board vessel.
Sail Rigging › Sails › Reinforcements and Chafe Patches
Issued 26 February 2018 Resolved
Secure/tighten nut attaching mainsail tack.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2018
Resolved 1 March 2018
Resolution: Nut tightened.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 February 2018 Resolved
Properly secure all high bilge water alarm and automatic bilge float switches to bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2018
Resolved 1 March 2018
Resolution: ALl bilge float switches properly secured.
Construction/Loadline › Hull › Hull Plating
Issued 26 February 2018 Resolved
Provide drainage limber hole in portside fwd compartment or install bilge pump and high water alarm for compartment.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: Limber hole installed.
Documentation › Manuals/Policy Documentation › Crude Oil Washing Operations/Equipment Manual
Issued 26 February 2018 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: Instructions posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 February 2018 Resolved
Provide current first aid kit.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: First aid kit updated.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 26 February 2018 Resolved
Properly label vessel name on child's PFDs.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: PFDs marked.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 February 2018 Resolved
Properly attach ground/bonding wire on port side fuel fill.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: Bonding wire secured.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 February 2018 Resolved
Update vessel's rigging maintenance log to include rig replacement and sail repairs.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: Rigging log updated.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 February 2018 Resolved
Properly post COI and stability letter.
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 9 March 2018
Resolution: COI Posted.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 5 December 2017 Resolved
Port side engine room override switch found to be broken.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2018
Resolution: Received tech report attesting to proper operation.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2017 Resolved
repair port hull that was severely damaged due to hard grounding
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 May 2017
Resolution: The hull was repaired with the original lay-up schedule using epoxy resin
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 28 March 2017 Resolved
MDE was partially submerged in sea water
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 May 2017
Resolution: MDE was replaced with new in-kind Yanmar
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 6 September 2016 Resolved
Refasten MSD/sewage tank.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 14 September 2016
Resolution: The sewage holding tank was refastened to the deck.
Engineering › Diesel Engine (propulsion-electric) › Bearing
Issued 6 September 2016 Resolved
Install new cutlass bearings.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 14 September 2016
Resolution: New cutlass bearings were installed.
Stability › Weathertight Integrity › General
Issued 6 September 2016 Resolved
Make forward 02 hatches weathertight.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 14 September 2016
Resolution: The hatches were resealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 September 2016 Resolved
Properly terminate dead-end wire in forward starboard compartment.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 14 September 2016
Resolution: The wire was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 September 2016 Resolved
Secure wires in port side aft-most compartment.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 14 September 2016
Resolution: The hanging wires were properly secured to the bulkhead.
Lifesaving › Lifefloat › Serviceable
Issued 26 February 2016 Resolved
Repair liferafts to serviceable condition. Vessel restricted to 3 mile domestic route until cleared.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 March 2016
Resolution: Life float lines all replaced and spliced. Paddles labeled and tacked into place.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 February 2016 Resolved
Provide sail rigging inspection log.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 March 2016
Resolution: Rigging inspection log in place.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 February 2016 Resolved
Replace starboard fwd deck hatch cover.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 26 April 2016
Resolution: New hatch installed.
Engineering › Bilge Water Management System › Pump
Issued 26 February 2016 Resolved
Prove proper operation of starboard aft bilge pump.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 March 2016
Resolution: Bilge pump working properly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 February 2016 Resolved
Provide indication light for automatic bilge pump operation at operating station.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 26 April 2016
Resolution: Indicators installed for bilge pumps.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 26 February 2016 Resolved
Prove proper operation of engine room ventilation closures.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 March 2016
Resolution: Ventilation closures properly repaired.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 February 2016 Resolved
Provide lifejacket stowage placards.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 March 2016
Resolution: LIfejacket storage properly labeled.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 February 2016 Resolved
Secure batteries in both port and starboard engine room.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 2 March 2016
Resolution: Batteries properly secured.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 14 March 2014 Resolved
Vessel is restricted to "motoring" operations only until proper documents/training, etc. are found satisfactory by an attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 14 March 2014
Resolved 22 April 2014
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 14 March 2014 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 22 May 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 March 2010 Resolved
Install netting mesh or additional course rails between the top most rail and deck so that no space is greater than four inches where pasengers have access to the railing.
Action required: 705 - Other - as specified
Due 9 May 2010
Resolved 11 March 2010
Resolution: Noted previous requirement issued for this item and subsequent appeal for reconsideration from owner. Correction of this item from previous requirement was not documented.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 March 2010 Resolved
Line attached to the ring lifebuoy noted not of approved type. Lifeline shall be buoyant, at least 60 ft, 5/16 in, dark in color or otherwise UV resistant. Renew lifeline with that of approved type.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 5 May 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 March 2010 Resolved
Vessel noted without current copy of US Coast Pilot. Provide current copy or appropriate excerpts for the area of operation.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 5 May 2010
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 11 March 2009 Resolved
Remove all Stability Letters and Sail Plans approved and issued prior to 15 April 2002. Ensure only the Stability Letter and Sail Plan approved and dated 15 April 2002 is on board vessel and available to the Master.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 10 June 2009
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 11 March 2009 Resolved
Provide and install current copy of form CG-2692 and CG-2692B in SMS Manual.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 10 June 2009
Documentation › Safety Management System › Response Measures Documentation
Issued 11 March 2009 Resolved
Provide and install Company Policy in regards to meeting the 2-Hour Rule within the SMS Manual.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 10 June 2009
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 11 March 2009 Resolved
Provide and install Company Policy in regards to the TWIC within the SMS Manual.
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 15 April 2009
Resolution: Cancelled/Withdrawn
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 March 2009 Resolved
Provide and install vessels name and homeport on stern of vessel as per Certificate of Documentation (COD).
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 10 June 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 March 2009 Resolved
Provide and install four (4) inch rail courses or equivalent as per 46 CFR 177.900(f)(1) or apply, in writing, to the OCMI for a Special Consideration, via MSD St. Thomas as per 46 CFR 175.550.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 10 June 2009
Resolution: Submitted Special Consideration Request.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2005 Resolved
Provide missing stbd running light cover.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2005
Construction/Loadline › Hull › Bottom Plating
Issued 14 September 2005 Resolved
Repair all nicks and dings throughout the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2005 Resolved
Provide non-corrosive clip for ring buoy waterlight.
Due 28 March 2005
Resolved 12 April 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 March 2005 Resolved
Provide copy of emergency procedures and post on vessel.
Due 28 March 2005
Resolved 12 April 2005
Personnel › Training
Issued 11 March 2003 Resolved
Provide proof of crew enrollment in earliest possible STCW basic safety training course.
Due 31 May 2003
Resolved 19 May 2003
Engineering › Bilge Water Management System
Issued 11 December 2002 Resolved
Replace or repair starboard High Water Level- Audible alarm
Due 10 January 2003
Resolved 11 March 2003
Stability › Incline Test
Issued 11 March 2002 Resolved
RE-CUT JIB TO 300SQ FT MAXIMUM
Due 11 April 2002
Resolved 12 April 2002
Lifesaving › Buoyant Apparatus
Issued 11 March 2002 Resolved
STENCIL 4 PERSON LIFEFLOAT WITH VSLS NAME LEGACY COMPONENT DESC: Marking
Due 18 March 2002
Resolved 18 March 2002
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 March 2002 Resolved
MARK STOWAGE CONTAINER FOR CHILDRENS LIFEJACKETS
Due 18 March 2002
Resolved 18 March 2002
Engineering › Fuel Oil Service System › Filter
Issued 11 March 2002 Resolved
PROVIDE IMPINGEMENT BOWL FOR RACOR FUEL FILTER
Due 18 March 2002
Resolved 18 March 2002
Engineering › Bilge Water Management System
Issued 11 March 2002 Resolved
PROPERLY SECURE HIGH BILGE LEVEL ALARM IN PORT LAZARETTE
Due 18 March 2002
Resolved 18 March 2002
Engineering › Bilge Water Management System › Pump
Issued 11 March 2002 Resolved
REPAIR INDICATOR LAMP FOR AUTOMATIC BILGE PUMP PORT AFT PUMP.
Due 18 March 2002
Resolved 18 March 2002
Lifesaving › Buoyant Apparatus
Issued 11 March 2002 Resolved
PROVIDE PADDLES FOR ALL LIFEFLOATS LEGACY COMPONENT DESC: Paddles
Due 18 March 2002
Resolved 18 March 2002
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 March 2002 Resolved
POST ALL CERTIFICATES AS REQUIRED BY 46 AND 33 CFR
Due 18 March 2002
Resolved 18 March 2002

Casualty record · 3

3 August 2005Routine · role: Involved in a Marine Casualty · activity 2455673
5 March 2024Routine · role: Involved in a Marine Casualty · 1 injured · activity 7885215
27 March 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7910052
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record