MAURY USCG vessel records Sign in
← All vessels

JOY II

JOY II is a 1984 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 1984, most recently in July 2025, along with 33 deficiencies — 3 with no resolution recorded —.

Records from 1984 to 2025. Most recent: inspection, 16 July 2025.

Built
1984
Last inspected
16 July 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

252371
Flag
UNITED STATES
—
Maury page id
psix-252371

Inspections, by type

…with no type recorded3
…past their stated due date3
Years with a record 28 calendar years (1984–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.3 ft × 12.5 ft × 6.2 ft
Registered tonnagegross 25 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARTHUR M BURCH · KALISPELL MT, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKALISPELL, MT
Trade endorsementsRegistry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

16 July 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8189140
7 October 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8020080
13 June 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710886
7 June 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7447753
9 June 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7225119
7 August 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7026509
8 October 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6840580
10 June 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6714069
12 June 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6501341
14 June 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6162524
13 June 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5916724
22 June 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4887874
6 June 2012 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4335756
13 September 2011 Simplified Stability Test
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4149484
19 July 2011 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4077966
19 June 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3328163
5 June 2007 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2952433
3 October 2006 Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2799462
20 July 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2719481
26 August 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2475676
1 July 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2196558
19 June 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1912329
3 May 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1612633
23 June 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1068270
13 June 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 820113
11 June 1999 Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411924
29 May 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1089139
6 July 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1011252
29 May 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 991269
5 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294968
15 June 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1306054

Deficiency record · 33

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2025 No resolution recorded
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Forward bulkhead penetrations in the engine compartment are missing sealant.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 July 2025 No resolution recorded
The name of a vessel must be marked in clearly legible letters and numbers on each life jacket. Multiple life jackets were missing the proper labeling.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 July 2025 No resolution recorded
Each life float must be fitted with two paddles; each paddle must be lashed to the life float to which it belongs and buoyant. The paddles were not lashed to the life float.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2016 Resolved
Twist on wire nuts used for electrical connections under the operators console. Replace wire nuts IAW 46CFR183.340(g).
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 13 June 2016
Resolution: Twist on wire nuts replaced with pressure type connectors.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 June 2016 Resolved
Certificate of Documentation onboard was expired. Renew Certificate of Documentation.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 July 2016
Resolution: Vessel is not required to maintain a valid Certificate Of Documentation, the vessel does not operate on the navigable waters of the United States IAW 46 CFR 67.9(b). Vessel operates on ST. [name withheld], Glacier National Park, Montana.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 19 July 2011 Resolved
Properly install and equip buoyant apparatus. 46 CFR 180.137; 46 CFR 180.175(e) by 02 AUG 11.
Condition: Improper Installation
Due 2 August 2011
Resolved 2 August 2011
Resolution: Buoyant apparatus is installed IAW regulations.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 July 2011 Resolved
Fix or replace bracket for aft port side fire extinguisher. 46CFR181.30-10(b) by 30 JUL 11.
Due 30 July 2011
Resolved 30 July 2011
Resolution: Fire extinguisher is properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 July 2011 Resolved
Install metal wire hangers with gasketing in engine space. 46 CFR 182.40-1(a)(4) by 02 AUG 2011
Condition: Improper Installation
Due 2 August 2011
Resolved 2 August 2011
Resolution: All wiring is properly supported.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 July 2011 Resolved
Replace hose on port side exhaust. 46 CFR 182.40-1(a)(4) by 02 AUG 2011
Condition: Improper/Lack of Maintenance
Due 2 August 2011
Resolved 2 August 2011
Resolution: New exhaust hose is installed.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 July 2011 Resolved
Post emergency instructions in a clearly visible location from operating station. 46 CFR 185.25-1 by 30 JUL 2011.
Due 30 July 2011
Resolved 30 July 2011
Resolution: Emergency instructions are now clearly visible.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2007 Resolved
Provide a visual indicator at the operation station for all installed automatic bilge pumps and alarms.
Condition: Unknown
Due 1 May 2008
Resolved 19 June 2008
Resolution: Installed Lite
Construction/Loadline › Structures › Superstructure
Issued 5 June 2007 Resolved
Provide proposal for secondary means of escape in fwd end of main cabin.
Condition: Unknown
Due 30 September 2007
Resolved 19 June 2008
Resolution: Installed Hatch
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 June 2007 Resolved
Prove annual fixed fire extinguishing system servicing.
Condition: Improper/Lack of Maintenance
Due 18 July 2007
Resolved 19 June 2008
Resolution: corrected
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 3 October 2006 Resolved
Stb. Engine raw water valve stuck in open position needs to be repaired and exercised
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2007
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 3 October 2006 Resolved
Port Propeller hub is to short allowing excessive free play for/aft between nut and thrust washer
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2008
Resolved 2 April 2008
Resolution: Installed new propeller
Operations/Management › Drills/Instruction › Abandon Ship
Issued 20 July 2006 Resolved
establish vessel specific procedures for abandon ship and food control and drill crew Daily checks of bilge alarm and pumps need to be recorded prior to operation each day
Due 20 July 2006
Resolved 21 June 2007
Construction/Loadline › Structures › Door
Issued 20 July 2006 Resolved
Locate and identify emergency exits from passenger area
Due 20 July 2006
Resolved 21 June 2007
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 20 July 2006 Resolved
Repair cooling water leak Stb engine heat exchanger end cover
Due 20 July 2006
Resolved 21 June 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear/Clutch Starter (electric)
Issued 20 July 2006 Resolved
Make port engine remote start operable
Due 20 July 2006
Resolved 21 June 2007
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 20 July 2006 Resolved
Investigate and propose a procedure to rescue passengers in the event of vessel sinking
Due 20 July 2006
Resolved 21 June 2007
Resolution: Evaluated operation and construction. Vsl is FRP w/in 1 mile from shore and will not be required PLS.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 May 2002 Resolved
MAKE FUEL SOLINOID VALVE OPERABLE ON BOTH ENGINES. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 30 June 2003
Resolved 28 June 2002
Fire Fighting
Issued 23 June 2001 Resolved
PROVIDE A B-1 FIRE EX. PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 23 July 2001
Resolved 23 June 2001
Fire Fighting
Issued 23 June 2001 Resolved
Install a means to reset devices used to automatically shut down ventilation systems and engines. 46 CFR 181.420 (b)(3).
Condition: Unknown
Due 23 July 2001
Resolved 23 June 2001
Lifesaving
Issued 13 June 2000 Resolved
PROVIDE A BOAT HOOK FOR MAN OVERBOARD RETRIVEL.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000
Lifesaving
Issued 13 June 2000 Resolved
_x001C_ PROVIDE A LADDER TO ASSIST IN MAN OVERBOARD RETRIEVAL.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000
Lifesaving
Issued 13 June 2000 Resolved
PROVIDE 60 FEET OF FLOATING LINE FOR LIFE RING.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000
Electrical
Issued 11 June 1999 Resolved
PROVIDE SECOND FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Construction/Loadline
Issued 11 June 1999 Resolved
FOR UPPER DECK RAILS, ENSURE GAP BETWEEN RAIL COURSES IS NO MORE THAN 4 INCHES IN ACCORDANCE WITH 46CFR177.900(g).
Condition: Unknown
Due 25 September 2003
Resolved 11 June 1999
Lifesaving
Issued 11 June 1999 Resolved
PROVIDE WATERLIGHT FOR RING BUOY. _x001C_ _x001C_ VESSEL IS RESTRICTED TO DAYTIME OPERATIONS ONLY UNTIL COMPLETED.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Lifesaving
Issued 11 June 1999 Resolved
OBTAIN 3 HAND FLARES AND 3 ORANGE SMOKE SIGNALS THAT ARE COAST GUARD APPROVED.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Fire Fighting
Issued 11 June 1999 Resolved
PROVIDE APPROVED FIRE SUPPRESSION SYSTEM FOR E/R SPACE.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Fire Fighting
Issued 11 June 1999 Resolved
MOUNT FIRE EXTINGUISHER BRACKET LOCATED AFT OF PASSENGER CABIN.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Construction/Loadline
Issued 11 June 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.