MAURY USCG vessel records Sign in
← All vessels

CHIOS STAR

CHIOS STAR is a 1984 freight ship. The Coast Guard has recorded 44 inspections since 1985, most recently in August 2011, along with 26 deficiencies — 3 with no resolution recorded — and 3 operational controls.

Records from 1985 to 2011. Most recent: inspection, 19 August 2011.

Built
1984
Last inspected
19 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8309452 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
252437
Flag
GREECE
—
Maury page id
psix-252437

Inspections, by type

…with no type recorded27
…past their stated due date3
Years with a record 19 calendar years (1985–2011)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13683 - Convention (Subpart B), Net Ton
26195 - Convention (Subpart B), Gross Ton
52176 - Displacement, Ton
43792 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

19 August 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4120399
10 January 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3924184
29 December 2010 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3915335
29 March 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3705108
22 March 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3700649
23 February 2010 ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex VI Survey · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3681264
10 May 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3471477
9 April 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3448989
8 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3449437
7 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3448284
22 January 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3398581
11 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3392012
11 January 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3392116
7 January 2009 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3387425
17 August 2004 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2165456
6 August 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2157621
3 August 2004 ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2155153
31 July 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2151247
27 July 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2147246
22 December 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1968230
19 December 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1969284
27 June 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1828169
27 June 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1828320
8 March 2002 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1492401
8 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 106896
25 June 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292352
18 May 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 277908
23 February 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 425230
13 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418012
6 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418053
9 January 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 411956
1 November 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 409554
30 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 368215
30 June 1994 Damage Survey · Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 864026
29 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83828
23 January 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 485584
26 March 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 349659
30 September 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 339575
24 September 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 339503
31 July 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 331726
31 December 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 320478
26 September 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 311663
31 January 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 528557
5 August 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 303382

Deficiency record · 26

Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 August 2011 Resolved
1560 All ships shall carry adequate chart for the intended voyage. The foreign chart currently being used for transit of Redwood City is of insufficient size and scale. Ship must have U.S. chart number 18651 prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2011
Resolved 19 August 2011
Resolution: Vessel has received U.S. Chart 18651.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 August 2011 No resolution recorded
0900 Fire resistance of doors shall, as far as practicable be equivalent to the division in which they are fitted. Doors required to be self closing shall not be fitted with hold back hooks. Multiple self closing class "A" doors were found to have hold back hooks and not capable of closing. Recommend class address the integrity of all doors.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 September 2011 — due date passed with no resolution recorded
Construction/Loadline › Structures › Ventilators
Issued 19 August 2011 No resolution recorded
1275 Ventilators must have steel coamings, be efficiently connected to the deck, and be fitted with weather tight closing appliances. multiple vents on deck were found to be wasted and missing rubber gaskets.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 September 2011 — due date passed with no resolution recorded
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 19 August 2011 No resolution recorded
0735 Fireman’s outfit shall be of material to protect from heat radiating from the fire and from burns. two of the fireman’s outfits need to be replaced due to the delaminating of the material and the seams coming apart.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 September 2011 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 29 December 2010 Resolved
0984 - Hull Crack - PSCO observed that while conducting an examination of the hull that on the port side one frame forward of the aft bulkhead separating 1TST from 2TST, located between longitudinal frame 6 and 7 below the deck level there is a fracture in the hull - ICLL 66, Reg 1
Action required: 705 - Other - as specified
Due 5 January 2011
Resolved 10 January 2011
Resolution: Received, reviewed and accepted class report from CCS attesting to permanent repairs to the hull.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 29 December 2010 Resolved
1400 - Propulsion & Aux. Machinery - PSCO observed that the engineering crew has installed a temporary flex hose from the main diesel engine cylinder oil tank pump to the feed line to the main diesel engine - SOLAS 74am / II-2/5
Action required: 705 - Other - as specified
Due 5 January 2011
Resolved 10 January 2011
Resolution: Received, reviewed and accepted class report from CCS attesting to permanent pipe installation on the main diesel engine cylinder oil tank.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 29 December 2010 Resolved
1599 - Other (Navigator) - PSCO observed that the VDR is giving an intermittent failure of the AC back up.
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 29 December 2010
Resolution: Deficiency corrected on the spot by the ships electrician. PSCO verified VDR tested without error.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 March 2010 Resolved
The radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2010
Resolved 29 March 2010
Resolution: Received, reviewed and accepted tech report from Mackay Marine sating the radar was repaired, tested and found satisfactory.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 23 February 2010 Resolved
2115 - Loading/ unloading/ cleaning proc. Carg. - While in static operating condition, the #4 cargo hatch forward hydraulic rams both port and starboard are leaking hydraulic fluid at a rate of one drop per second. The ships crew has taken appropriate measures to prevent pollution IAW their SOPEP manual. The [name withheld] informed the PSCO that replacement parts were onboard. - MARPOL Anx 1 reg 15
Action required: 705 - Other - as specified
Due 9 March 2010
Resolved 1 March 2010
Resolution: Received reviewed and accepted class report from China [name withheld] stating deficiency has been rectified. The O ring seals of No. 4 cargo hold hydraulic rams both port and starboard were replaced.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 8 April 2009 Resolved
Port anchor windlass found to be inoperative due to a loose brake nut.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2009
Resolved 9 April 2009
Resolution: Received class report rectifying deficiency.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 January 2009 Resolved
While operating within the Sector New Orleans COTP zone the vessel acquired an inoperable radar.
Action required: 15 - Rectify deficiencies by next port
Due 25 January 2009
Resolved 26 January 2009
Resolution: Received proper documentation satisfying requirement.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 August 2004 Resolved
Provide class report for identification of all fuel/oil tanks listed on IOPP for ships understanding so crew can make proper entries in oil record book with regard to quantities of oil retained on board. MARPOL 73/78.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 January 2009
Engineering
Issued 25 June 2001 Resolved
NO. 3 GENERATOR LEAKING FUEL AT FUEL PUMP. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO 25 AUGUST 2001. (SOLAS 74A I/11)
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001
Fire Fighting
Issued 23 February 1999 Resolved
CONDUCTED PROPER FIRE DRILL._x001C_ SOLAS 74 (AMENDED) REG III/53
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Lifesaving
Issued 23 February 1999 Resolved
CONDUCTED PROPER ABANDON SHIP DRILL._x001C_ SOLAS 74 (AMENDED) REG III/18.3.4
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Fire Fighting
Issued 9 January 1998 Resolved
REPAIR FIRE MAIN WHERE LEAKING PRIOR TO NEXT TO US PORT.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Unknown
Issued 9 January 1998 Resolved
REPAIR LEAKING HYDRAULIC LINE ON STARBOARD SIDE PRIOR TO NEXT US PORT.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Navigation
Issued 1 November 1997 Resolved
REPLACE DAYLIGHT SIGNALLING LAMP BULB THAT'S EXTINGUISHED. _x001C_ VESSEL REQUIRED TO HAVE AN EFFICIENT/OPERATIONAL DAYLIGHT SIGNALLING LAMP IN ACCORDANCE WITH SOLAS CHAPTER V REGULATION 11.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Lifesaving
Issued 1 November 1997 Resolved
CONDUCT FIRE AND BOAT DRILL IN ACCORDANCE WITH SOLAS CHAPTER III REGULATION18.3.3.1
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Navigation
Issued 24 September 1990 Resolved
PRE-ARRIVAL TESTS FOR ENTERING AND GETTING UNDERWAY WERE NOT PROPERLY LOGGED IN VSL LOG._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Documentation
Issued 24 September 1990 Resolved
VSL'S OIL RECORD BOOK MAINTAINED FOR ONLY 6 MONTHS INSTEAD OF THE REQUIRED 3 YRS.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Accommodation/Occupational Safety
Issued 24 September 1990 Resolved
VSL DID NOT SEPERATE PLASTICS FROM GARBAGE. GARBAGE WAS GATHERED AT_x001C_ THE STERN FOR OVERBOARD DISCHARGE.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Navigation
Issued 24 September 1990 Resolved
TESTS FOR GETTING UNDERWAY WERE NOT COMPLETED PRIOR TO DEPARTING_x001C_ HOMER, AK, AFTER SITTING @ ANCHOR FROM 21SEP90 TO 23SEP90.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Documentation
Issued 24 September 1990 Resolved
VSL HAS NO OIL TRANSFER PROCEDURES!_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Navigation
Issued 31 July 1989 Resolved
U.S. COAST PILOT, VOL. 7, 1988 EDITION, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINERS CORRECTIONS AS FOLLOWS: 1988-16, 25, 31, 33, 42, 49, 51,52. 1989-3, 11, 16, 20.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Deck/Cargo
Issued 5 August 1985 Resolved
NO OIL TRANSFER PROCEDURES
Condition: Unknown
Due 5 August 1985
Resolved 5 August 1985

Ownership record