← All vessels
DRIFTER
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named DRIFTER
DRIFTER is a 1985 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1985, most recently in May 2026, along with 127 deficiencies and 3 operational controls.
Records from 1985 to 2026. Most recent: inspection, 5 May 2026.
- Built
- 1985
- Last inspected
- 5 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 127 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
684905
WUT8259
252543
Flag
UNITED STATES
367390290
Maury page id
psix-252543
Inspections, by type
…with no type recorded4
Years with a record
36 calendar years (1985–2026)
The 69 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.7 ft × 15.2 ft × 6.2 ft
Registered tonnagegross 45 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS & R.E. YEOMANS · ARUNDEL, ME, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHILTON HEAD ISLAND, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WUT8259MMSI 367390290 · active · compulsorily equipped · granted 2 February 2019, expires 16 February 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 69
5 May 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8367794
6 May 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8129923
14 January 2025
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8063554
9 April 2024
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7892255
10 January 2023
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7618826
15 November 2022
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7578957
28 May 2022
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7463901
2 May 2022
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7445199
26 April 2021
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7182993
12 January 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7123245
4 March 2020
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6920510
14 May 2019
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6684054
26 November 2018
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6589793
6 March 2018
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6364595
7 July 2017
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6204417
23 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6166509
25 January 2017
Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6078344
23 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5886379
29 May 2014
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4873679
1 February 2011
Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3936985
3 March 2010
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3689377
1 March 2010
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3685155
19 November 2008
Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3365961
28 January 2008
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3136202
23 April 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2908715
26 March 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2890632
29 January 2007
Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2863214
11 May 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2646847
14 March 2005
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2309485
7 February 2005
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2287691
26 April 2004
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2052672
28 January 2003
COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1735858
26 November 2001
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1466810
28 October 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 796361
7 September 1999
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1406587
26 April 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 790421
12 April 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 787268
11 February 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1130278
4 February 1999
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1395105
4 November 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 804294
8 September 1998
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1395029
16 July 1997
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1442603
13 February 1997
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1465301
30 September 1996
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1442462
24 July 1995
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1440950
24 March 1995
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1471324
21 September 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1180258
8 August 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1179636
20 July 1994
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1438201
20 September 1993
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1423826
11 August 1993
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 848634
28 December 1992
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1471644
20 July 1992
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1456069
24 January 1992
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1259550
26 July 1991
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1243583
28 February 1991
Damage Survey · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1236919
1 October 1990
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1235809
29 August 1990
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 913296
30 April 1990
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1235359
2 August 1989
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 890208
23 January 1989
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1206915
13 October 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1198353
28 July 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1036677
24 May 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1043653
28 July 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023777
12 November 1986
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1323550
22 May 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 985449
1 August 1985
Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 981645
21 June 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 981643
Deficiency record · 127
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 April 2024
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. Vsl life float was not marked with persons capacity. 46 CFR 185.604(e)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2024
Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vsl missed first annual inspection, when the 3 month post-anniversary date was 13 March 2024. 46 CFR 176.500(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 May 2022
Resolved
A hatch exposed to the weather must be watertight.
Aft hatch failed hose test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 May 2022
Resolved
A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
line used as tether is wasted and breaking.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2022
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Plastic trash cans were present.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Placard was for wrong style of life jacket.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 May 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Tide tables
Missing tide table
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 2 May 2022
Resolved
A crew accommodation space and a work space must be of sufficient size, adequate construction, and with suitable equipment to provide for the safe operation of the vessel.
Aft crew ladder has loose rungs that needs to be fixed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 2 May 2022
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage.
Missing securing device.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2022
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter.
Two life jackets were un-servicable but the vessel had sufficient number of life jackets on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2021
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
STBD exhaust manifold leak. Provide repair plan.
46 CFR 182.01-5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions.
Lazarette bilge suction check valve was locked in place and not operating, restricting bilge suction. Clean strainers to ensure adequate suction.
46 CFR 182.25-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferable from an accessible position on the weather deck.
Fuel shutoff valve rusted and wasted. Needs to be replaced.
46 CFR 182.20-40(b)(3)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 April 2021
Resolved
A hatch exposed to he weather must be watertight / A hatch cover must have a securing device and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Aft deck hatch frame missing screws and hatch not connected to the frame.
46 CFR 179.360(a)&(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2021
Resolved
Where flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, mat be used. Such hose shall overlap metallic pipe ends at least 1.5 times the pipe diameter and shall be secured at each end by two clamps of corrosion resistance metal.
Port MDE piping missing double clamp.
46 CFR 182.20-30(d)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 April 2021
Resolved
Each life float must be secured to the vessel by a painter and a float-free link. The float-free link must be certified to meet Subpart 160.073 of this chapter, of proper strength for the size of the life float as indicated on its identification tag.
Weak link identification tag faded and could not verify strength capabilities. Provide acceptable identification tag by manufacturer or replace.
46 CFR 180.20-1(a)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the Inland Navigation Rules.
Stern light was non-operational. Port and STBD running light backgrounds were faded and no longer matte black. Restricted to daytime operations until satisfactory to marine inspector.
46 CFR 183.420
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 April 2021
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus.
Tiller arm linkage wasted and has excessive movement. Provide repair plan to the satisfaction of marine inspector.
46 CFR 182.30-1
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Replace 5 adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 May 2020
Resolved
Each lifefloat must be fitted with two paddles. Replace cracked lifefloat paddle.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 19 May 2020
Resolved
General construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Fill all bulkhead penetrations with approved firestop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2020
Resolved
An exposed hazard must be properly protected by a cover or guard. Missing machinery guard on forward end of port engine.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. All around white light lens is faded significantly, lens to be replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency towing arrangements and procedures
Issued 19 May 2020
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions missing.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 May 2019
Resolved
Vessel restricted to 1000 feet from shore due to VHF radio missing DSC capability.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 May 2019
Resolved
Life Float showing signs of deterioration, repair as per manufacturer instructions.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2019
Resolved
Hull penetration in lazarette needs to be removed if not in use.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2019
Resolved
Non watertight penetration located in the engine room blkhd must be made watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 May 2019
Resolved
Hull penetration in engine room compartment must be double hose clamped.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 15 May 2019
Resolved
Vessel to provide to USCG with CPR Certification documentation.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 March 2018
Resolved
Repair visual light on engien room high water alarm.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 March 2018
Resolved
Paint nav lights background flat black.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 March 2018
Resolved
Repair gasket leak on heat exchanger seal & tighten raw water leak on hose gasket on stbd MDE.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2017
Resolved
Place guards over stbd MDE fly wheel.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 23 May 2017
Resolved
Tighten packing on stbd shaft to stop excessive leaking.
Communications › Radio Communications › EPIRB
Issued 23 May 2017
Resolved
Renew expired EPIRG hydrostatic release.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 May 2017
Resolved
Demonstrate fireboy MDE shutdown & override restart is operational.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 23 May 2017
Resolved
Mark storage location for fire extinguishers IWO inside bar.
Lifesaving › Lifefloat › Serviceable
Issued 23 May 2017
Resolved
Place spacers between stacked life floats.
Lifesaving › Lifefloat › Painter
Issued 23 May 2017
Resolved
Inspect life float painter and make available for MI or renew painter.
Construction/Loadline › Hull › Bottom Plating
Issued 25 January 2017
Resolved
Provide repairs to 20 blisters located below the waterline.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 May 2016
Resolved
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 May 2014
Resolved
Prove proper operation of the automatic bilge light for engine room space. 46CFR182.530
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 May 2014
Resolved
Prove proper operation of the magnetic compass light. 46CFR184.20-1
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 30 May 2014
Resolved
Provide proof of company DAPI policy IAW 46CFR16.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2014
Resolved
Provide wire support for wire laying on top of fuel tank.
Engineering › Bilge Water Management System › Interface Detector
Issued 1 March 2010
Resolved
Properly secure loose bilge float switch for the alarm panel in the vsl's aft lazerette.
Communications › Visual Communication › Warning Sign (gangway)
Issued 1 March 2010
Resolved
Properly label emergency engine room vent closures and emergency fuel shut off valves.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 March 2010
Resolved
Properly repair vsl's stern light. Vsl restricted to day time operations until this light is repaired.
Documentation › Certificates/Documents › FCC SSL
Issued 1 March 2010
Resolved
Renew FCC safety certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 March 2010
Resolved
Properly repair vsl's VHF radio.
Communications › Public Address System › Loudspeaker
Issued 1 March 2010
Resolved
Properly repair or replace vsl's public address system.
Lifesaving › Lifefloat › Markings
Issued 1 March 2010
Resolved
Properly restencil vsl's name onto life floats and ring buoys.
Fire Fighting › Nozzles › Type
Issued 1 March 2010
Resolved
Provide nozzle for vsl's fire hose.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 1 March 2010
Resolved
Provide onboard updated light list and coast pilot.
Lifesaving › Lifefloat › Retroreflective Material
Issued 1 March 2010
Resolved
Renew worn out retro tape on vsl's life float.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2010
Resolved
Provide corrosion resistant clip for vsl's life ring buoy float light.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 19 November 2008
Resolved
Poor operating station visibility due to wear and tear on bridge windows. Replace/Renew to original state. 46 CFR 177.1030
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 November 2008
Resolved
Missing safety guard on fire pump belt drive. Install safe guard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 November 2008
Resolved
Inoperable navigation lights due to damaged wires. Repair/Replace to new.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 November 2008
Resolved
Expired First Aid/CPR cerification. (46 CFR 28.210)
Fire Fighting › Ventilation Systems › Operating Controls
Issued 19 November 2008
Resolved
Vessel has fixed fire fighting system with no ventilation covers. Missing engine room ventilation covers.
Lifesaving › Lifefloat › Lifeline
Issued 19 November 2008
Resolved
Repair life float ensure life float is vivid reddish orange, replace worn grab lines, and worn line on water lights.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 November 2008
Resolved
Replace damaged life ring on upper deck and renew lanyard on water light.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 19 November 2008
Resolved
Depth sounder inoperable.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 November 2008
Resolved
Condemned 14 adult life jackets due to damaged sustained by rats. Replace missing lifejackets.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 January 2008
Resolved
Properly secure fwd bow hand rails port and stbd loose. Mounting hardware missing or loose.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 January 2008
Resolved
Properly repair vessel e-lights that are not working.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 28 January 2008
Resolved
Properly install PSI gauge on vsl's fire pump discharge piping.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 January 2008
Resolved
Properly label port and stbd emergency fuel shut off valves.
Engineering › Bilge Water Management System › Manifold
Issued 28 January 2008
Resolved
Label valves for vsl's fixed bilge system, post operating instructions for the same.
Fire Fighting › Fire Hydrants › Location/Position
Issued 28 January 2008
Resolved
Properly label vsl's fire hydrant.
Engineering › Bilge Water Management System › Valve
Issued 28 January 2008
Resolved
Install skin valve on vsl's bilge ovbd discharge piping in the engine room and fuel tank void.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 28 January 2008
Resolved
Renew wasted and broken hose clamps on vsl's port MDE raw water suction hose from the sea chest to the sea strainer.
Communications › Visual Communication › Warning Sign (gangway)
Issued 28 January 2008
Resolved
Properly post garbage and oil discharge placards.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2008
Resolved
Remove dead end wires in engine room under MDE starting batteries.
Communications › Audible Communications › SPD (Other)
Issued 28 January 2008
Resolved
Repair vsl's public address system.
Construction/Loadline › Hull › Hull Plating
Issued 28 January 2008
Resolved
Submit repair proposal to make permanent repairs to vsl's aft main deck approximately 3 ft in all directions fm the aft lazerette hatch. Deck found soft from excessive rot in this area.
Documentation › Markings/Placards › Official Number (US)
Issued 28 January 2008
Resolved
Permanently affix vsl's official number to interior hull structural member.
Engineering › Bilge Water Management System › Pump
Issued 28 January 2008
Resolved
Renew vsl's required portable hand bilge pump. Pump is not working.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 March 2007
Resolved
Secure loose wiring in engine room.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 26 March 2007
Resolved
Remove all deadend wiring from vessel.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 March 2007
Resolved
Re-apply retro tape to three children lifejackets.
Lifesaving › Lifefloat › Serviceable
Issued 26 March 2007
Resolved
Repair coverings on lifefloat with approved material from [name withheld].
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 26 March 2007
Resolved
Bridge windows need to be either polished or replaced.
Lifesaving › Lifeboat Equipment › Oar
Issued 26 April 2004
Resolved
Renew 04 life float paddles. Paddles splitting from sun exposure.
Lifesaving › Lifebuoys
Issued 26 April 2004
Resolved
Renew ring buoy. Line frayed, ring split.
Lifesaving › Visual Distress Signals (General)
Issued 26 April 2004
Resolved
Renew all (03) float light batteries.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 November 2001
Resolved
Raw water strainer nipple on STBD engine cracked and leaking.
Engineering › Steering Gear System
Issued 26 November 2001
Resolved
Steering pivit pin assembly had excessive amount of play in it, top bolt in the assembly was excessively corroded. LEGACY COMPONENT DESC: Pin
Construction/Loadline › Penetrations
Issued 26 November 2001
Resolved
Sluice valve in #2 compartment (in subdivision bulkhead) needs blankoff plate.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 26 November 2001
Resolved
STBD shaft leaking.
Fire Fighting
Issued 7 September 1999
Resolved
PROVE SERVICABILITY OF ONE (1) PORTABLE BII FIRE EXTINGUISHER.
Construction/Loadline
Issued 7 September 1999
Resolved
INSTALL BILGE HIGH LEVEL ALARM IN WAY OF THE LAZERETTE.
Construction/Loadline
Issued 7 September 1999
Resolved
INSTALL BILGE ALARMS FOR EACH COMPARTMENT (ENGINE ROOM, FUEL TANK, AND LAZARETTE).
Lifesaving
Issued 7 September 1999
Resolved
PROVIDE NEW HYDROSTATIC RELEASE FOR EPRIB. ROUTE RESTRICTED TO NMT THREE (3) MILES OFF SHORE UNTIL HYDROSTATIC RELEASE IS RENEWED.
Construction/Loadline
Issued 4 February 1999
Resolved
Replace handles on overboard valves for main engines. Both handles for both valves have corroded and have fallen off.
Construction/Loadline
Issued 4 February 1999
Resolved
Replace both overboard valves in tank room. Both valves were corroded and failed to operate.
Construction/Loadline
Issued 4 February 1999
Resolved
Repair or replace windshield on main deck. Windshield is no longer weathertight.
Construction/Loadline
Issued 8 September 1998
Resolved
CLEAN ENGINE ROOM BILGES OF OILY RESIDUE.
Fire Fighting
Issued 8 September 1998
Resolved
CONDUCT FIRE SERVICING ON HALON 1301 BOTTLE IN WAY OF THE ENGINE ROOM.
Construction/Loadline
Issued 8 September 1998
Resolved
RENEW/REPAIR THE PORTABLE HAND BILGE PUMP.
Fire Fighting
Issued 8 September 1998
Resolved
PRIOR TO 11 MARCH 1999, ENSURE THE FIXED FIREFIGHTING SYSTEM MEETS THE REQUIREMENTS FOUND IN 46CFR181.400.
Documentation
Issued 8 September 1998
Resolved
PROVIDE EVIDENCE OF FIRST AID/CPR TRAINING FOR CREW._x001C_
Lifesaving
Issued 8 September 1998
Resolved
PROPERLY ATTACH LIFE LINE TO RING BUOY WITH 60FT OF BUOYANT LINE, NON- KINKING, 5/16 INCH MINIMUM DIAMETER, HAVE A BREAKING STRENGTH OF AT LEAST 1,124 POUNDS AND BE OF A TYPE RESISTANT TO UV LIGHT._x001C_ _x001C_
Lifesaving
Issued 8 September 1998
Resolved
ATTACH RETROREFLECTIVE TAPE TO LIFE RING.
Lifesaving
Issued 8 September 1998
Resolved
INSTALL RETROREFLECTIVE TAPE TO NOTED LIFEJACKETS (7).
Accommodation/Occupational Safety
Issued 8 September 1998
Resolved
PROPERLY MOUNT/SECURE MSD TANK AT NEXT DRYDOCK.
Lifesaving
Issued 8 September 1998
Resolved
ATTACH LIFE RING WATER LIGHT WITH A 3 TO 6 FT LANYARD AND CLIP.
Documentation
Issued 20 July 1994
Resolved
Provide drug testing results and provide drug testing program as required by 46 CFR part 16.
Fire Fighting
Issued 29 August 1990
Resolved
INSTALL AUTOMATIC ENGINE SHUTDOWN FOR HALON SYSTEM IN ENGINEROOM.
Lifesaving
Issued 29 August 1990
Resolved
RENEW HAND HOLD LINE ON RING LIFEBUOY.
Lifesaving
Issued 29 August 1990
Resolved
RENEW HAND HOLD LINE ON 22 PERSON LIFEFLOAT
Engineering
Issued 2 August 1989
Resolved
LABEL VALVES ON BILGE SYSTEM MANIFOLD.
Lifesaving
Issued 2 August 1989
Resolved
LABEL LIFEFLOAT PADDLES WITH THE VESSEL NAME IAW 46 CFR 185.30-5(A).
Lifesaving
Issued 2 August 1989
Resolved
REMARK LIFEFLOATS WITH VESSEL NAME AND CAPICITY IAW 46 CFR 180.20-5.
Navigation
Issued 2 August 1989
Resolved
PUT COTTER PINS IN TIILER CROSSBAR PINS AND DOUBLE NUT BOLT ATTACHING STEERING RAM TO TILLER.
Lifesaving
Issued 13 October 1988
Resolved
SEGREGATE CHILDS LIFE PRESERVER STOWAGE.
Lifesaving
Issued 13 October 1988
Resolved
STENCIL EACH LIFE RAFT WITH CAPACITY AND NAME OF VESSEL.
Lifesaving
Issued 13 October 1988
Resolved
PROCURE AND PROPERLY MOUNT WEAK LINK(20 AND OVER) AND 100 FT CERTIFIED PAINTER ASSEMBLY THEN ATTACH TWO RAFTS TOGETHER.
Lifesaving
Issued 13 October 1988
Resolved
PROVIDE 2 PADDLES EACH 4 FEET LONG, LASHED TO EACH LIFE RAFT.
Lifesaving
Issued 13 October 1988
Resolved
PROVIDE STACKING STRIPS BETWEEN EACH LIFERAFT.
Lifesaving
Issued 28 July 1988
Resolved
RENEW HAND LINES ON ALL LIFE FLOATS.
Navigation
Issued 28 July 1988
Resolved
STERNLIGHT BROKEN.
Lifesaving
Issued 28 July 1988
Resolved
PROPERLY SECURE WEAK LINK TO LIFE FLOATS.
Fire Fighting
Issued 28 July 1988
Resolved
PROVIDE ONE BII FOR CABIN AND SERVICE BII FOR E.R.
Fire Fighting
Issued 28 July 1987
Resolved
HAVE THE 3 B-II FIRE EXTINGUISHERS ABOARD THE VESSEL SERVICED OR REPLACED.