SCUBA CAT

SCUBA CAT is a 2000 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 2000, most recently in July 2025, along with 40 deficiencies and 1 operational control.

Records from 2000 to 2025. Most recent: inspection, 28 July 2025.

Built
2000
Last inspected
28 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP2036
Flag
UNITED STATES
367574840
Maury page id
psix-2527

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (2000–2025)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL LA · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 11 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP2036MMSI 367574840 · active · compulsorily equipped · granted 8 September 2023, expires 8 September 2033
WDG8181MMSI 367574840 · expired · compulsorily equipped · granted 15 May 2013, cancelled 15 July 2023
WCZ7174MMSI 367441540 · expired · compulsorily equipped · granted 3 March 2010, cancelled 23 May 2020
EX135MMSI 367421410 · expired · exemption · granted 19 January 2010, cancelled 31 January 2015
WDE9797MMSI 367421410 · expired · compulsorily equipped · granted 7 August 2009, cancelled 12 October 2019
EX83MMSI 367102780 · expired · exemption · granted 28 March 2006, cancelled 3 April 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 43

28 July 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8145413
17 October 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8007773
8 August 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7907488
18 April 2024 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7883030
20 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7694313
27 April 2023 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7666896
10 April 2023 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7665800
15 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7651624
27 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426881
27 July 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7268850
1 April 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7165495
26 March 2020 COI Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6932047
30 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6679013
1 May 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6404016
23 March 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6364348
12 March 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6364336
7 April 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6106820
11 May 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5863845
28 April 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5842916
14 May 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4842840
14 March 2014 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4816254
27 June 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4359967
25 March 2010 DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3682601
15 March 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3682587
8 July 2009 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3520335
21 May 2008 Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3186237
25 March 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3159198
6 March 2008 Internal Structural Exam · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3159728
5 March 2008 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3159191
23 April 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2911539
27 March 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594025
9 February 2006 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2581217
4 April 2005 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2326226
17 November 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2243018
10 November 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2238696
19 February 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2009224
6 February 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001724
21 May 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1794120
16 May 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1617915
4 March 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1494087
7 March 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391515
21 April 2000 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381871
5 April 2000 Initial Construction-Excluding Oversight · Plan Review "T" Boat · Inclining Experiment · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464281

Deficiency record · 40

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 October 2024 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel's station license is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2024
Resolved 24 October 2024
Resolution: Vessel provided current FCC radio station license.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 October 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel's Radiotelephony Certificate is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2024
Resolved 4 November 2024
Resolution: Received certificate via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2023 Resolved
The exhaust pipe cooling water system must comply with the requirements of this paragraph. The part of the exhaust system between the point of cooling water injection and the engine manifold must be water-jacketed or effectively insulated and protected in compliance with §§ 177.405(b) and 177.970 of this chapter. MI identified deteriorated lagging serving exhaust system on both PORT & STBD engine. 46CFR182.425(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 9 October 2023
Resolution: New lagging was installed in Port and STBD Engine exhausts.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 September 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. MI identified incorrect weak link serving 02 life floats and both life floats missing stenciling requirements. 46CFR180.175(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: MI verified correct weak link and stenciling requirement. ALL SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2023 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050.MI identified damaged retroflected tape on life ring. 46CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Retroflected tape now installed. ALL SAT.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 20 September 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. MI identified missing alcohol tests onboard. 46CFR4.06-15(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Alcohol tests now onboard. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 September 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MI identified fire, MOB, and Fire emergency instructions not posted. 46CFR185.510
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2023
Resolved 29 September 2023
Resolution: Instructions now posted. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 27 April 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The vessel did not have emergency instructions mounted at the operating station or available for inspection on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 11 April 2023
Resolution: Vessel owner provided emergency instructions on board.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 27 July 2021 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio Beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 46 CFR part 80. The vessels Radio Telephony Certificate was found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 11 April 2023
Resolution: Vessel owner provided valid FCC Radiotelephony Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 July 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible, as well as U.S. Coast Pilot or similar publication, Coast Guard Light List and Tide Tables. Vessels charts and navigation publications were not up-to-date (i.e. not most recent chart/publication).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 11 April 2023
Resolution: Vessel owner provided current navigation publications.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 27 July 2021 Resolved
The float free link required by 46CFR180.130(a)(1) must be of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. The identification tag for both float free links were missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2021
Resolved 27 April 2022
Resolution: Float-free link identification tag for life floats was present.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 July 2021 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The light provided for the port side life float was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2021 Resolved
Each life jacket carried on a vessel on oceans route must have a life jacket light; Each life jacket light must be securely attached to the front shoulder area of the life jackets. Several life jackets were found to be missing the required light.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 July 2021 Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Paddles on both life floats were not attached/lashed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 July 2020 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which installed. EPIRB Hydrostatic Release unit is passed its due date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 22 August 2020
Resolution: Operator provided pictures and documentation of new EPIRB Hydrostatic realease installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 May 2019 Resolved
Railing cannot have more than 12 inches of exposed area with in 36 inches. Vessel currently has one rope line at 36 inches for its aft rail.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 12 November 2019
Resolution: Vessel provided acceptable coarses to aft railing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 May 2019 Resolved
Battery connections must be connected with permanent type connectors. Vessel is using wing nuts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2019
Resolved 31 May 2019
Resolution: Replaced wing nuts with approved permanent nut.
Lifesaving › Lifefloat › Serviceable
Issued 12 March 2018 Resolved
REPAIR STBD LIFEFLOAT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. TOTAL PERSON COUNT REDUCED TO 22 WHEN OPERATING BEYOND 3NM FROM SHORE. 46CFR180.204
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 May 2018
Resolution: Owner replaced both lifefloats and properly rigged them.
Engineering › Freshwater System (cylinder head cooling) › Valve
Issued 28 April 2016 Resolved
Replace in kind 2" ball valves supplying the main engines.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 11 May 2016
Resolution: (02) ball valves were replaced in kind.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 April 2016 Resolved
Make rail height 36" in all areas where passengers have access.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 11 May 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 May 2014 Resolved
Provide current tide tables booklet onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 14 May 2014
Resolution: Fixed on the spot.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 March 2010 Resolved
Provide current crew list for the Drug program
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 26 March 2010
Resolution: Received in an email the crew list.
Lifesaving › Lifefloat › Serviceable
Issued 25 March 2010 Resolved
Repair upper life float, persons allowed is reduced to 27 persons
Action required: 705 - Other - as specified
Due 25 May 2010
Resolved 4 May 2010
Resolution: Received Photo of repaired life float, Person allowed is back to 49
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 July 2009 Resolved
Provide unexpired alcohol test kits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2009
Resolved 25 August 2009
Resolution: Replacement kits provided.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 8 July 2009 Resolved
Provide cover for exposed electrical connectors in midship space IAW 46 CFR 183
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 August 2009
Resolved 25 August 2009
Resolution: Photo provided of installed cover.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 8 July 2009 Resolved
Provide an FCC Safety Radio Telephony certificate. Route restricted to 1000 ft offshore until cleared.
Action required: 705 - Other - as specified
Due 8 August 2009
Resolved 10 August 2009
Resolution: Correspondence with servicing technician at Neptune Marine Electronics confirmed that the FCC inspection was performed and radio installation found satisfactory.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 July 2009 Resolved
Provide an MF radio installation or satellite phone with appropriate FCC waiver. Vessel restricted to the following route until Completed: Pacific Ocean between Point Conception, CA and 32-15 N Lat, not more than 20 miles from a harbor of safe refuge on the mainland shore. A voyage from the mainland to Catalina Island and anywhere within 5 miles of Catalina Island is considered within this route
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 January 2010
Resolved 21 December 2009
Resolution: Valid FCC radio exemption provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 23 April 2007 Resolved
Provide satisfactory evidence of the required servicing to the fixed gas fire extinguishing system
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2007
Resolved 26 April 2007
Resolution: O/O provide satisfactory evidence of the required servicing to the fixed gas fire extinguishing system.
Lifesaving › Hand Flares › Not on Board
Issued 23 April 2007 Resolved
Provide fixed orange handheld smoke distress signal
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2007
Resolved 26 April 2007
Resolution: O/O Provide fixed orange handheld smoke distress signal.
Fire Fighting › Fire Bucket › Availability
Issued 23 April 2007 Resolved
Provide two 2-1/2 gallon buckets with appropriate markings.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 23 April 2007
Resolution: O/O Provided two 2-1/2 gallon buckets with appropriate markings.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 April 2007 Resolved
Provide current and up-to-date US. Coast Pilot and CG Light List.
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 26 April 2007
Resolution: O/O Provided current and up-to-date US. Coast Pilot and CG Light List.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 April 2007 Resolved
Provide current and up-to-date US. Coast Pilot and CG Light List.
Action required: 705 - Other - as specified
Due 13 May 2007
Resolved 26 April 2007
Resolution: O/O Provided current and up-to-date US. Coast Pilot and CG Light List.
Lifesaving › Hand Flares › Expired
Issued 27 March 2006 Resolved
Replace all orange hand-held flares. Flares expired on February 2006. Vessel is restricted to operating on short runs and limited to approximately 30 minutes away from the dock. 46CFR180.68(a)
Action required: 705 - Other - as specified
Due 30 March 2006
Resolved 30 March 2006
Resolution: Vessel provided fax receipt of the purchase of new flares.
Communications › Radio Communications › Satellite Communications Capability
Issued 19 February 2004 Resolved
Meet FCC MF radio requirements for 100 mile route. LEGACY COMPONENT DESC: MF Radio
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 30 March 2006
Resolution: Vessel''s master provided CG Marine Inspector with wavier letter from FCC.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2004 Resolved
Reduce waterlight pendant to within 3'-6'. It was attached to a lifeline-lenth pendant, but other lifebuoy had proper lifeline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Corrected / spliced on the spot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 February 2004 Resolved
Repair bilge alarm for lazzarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Corrected on the spot.
Lifesaving
Issued 21 April 2000 Resolved
Install bonding wires between the fuel fill fitting and the fuel tank.
Condition: Unknown
Due 2 June 2000
Resolved 18 July 2000
Lifesaving
Issued 21 April 2000 Resolved
Mark number of persons capacity on the lifefloats.
Condition: Unknown
Due 21 May 2000
Resolved 18 July 2000
Lifesaving
Issued 21 April 2000 Resolved
Provide a drug testing program meeting all applicable requirements in 46CFR16.
Condition: Unknown
Due 21 May 2000
Resolved 18 July 2000
Construction/Loadline
Issued 21 April 2000 Resolved
Provide a check valve at the overboard connection for all submersible bilgepumps or show an exemption letter.
Condition: Unknown
Due 11 July 2000
Resolved 18 July 2000

Ownership record