Inspection history · 74
14 July 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8185325
8 July 2024
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7946189
9 February 2024
ISM SMC Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7863144
15 August 2023
MTSA Verification · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7768632
9 August 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7529046
29 June 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7239421
16 June 2021
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7227189
17 September 2020
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7059802
3 October 2019
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6827032
10 April 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6659700
26 September 2018
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6588609
10 September 2018
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6537050
8 November 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6303201
21 September 2017
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6271441
19 July 2016
Deficiency Check · COI Inspection · Internal Structural Exam · Drydock Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5945095
22 October 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5748322
20 October 2014
MTSA Verification · Periodic Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5008317
16 October 2013
Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4735694
17 September 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4718033
27 October 2011
Cargo Tank Internal · COI Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4177400
30 November 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3900973
16 November 2010
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3892166
15 September 2009
Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3549780
2 February 2009
MARPOL Annex V Examination · MTSA Verification · MARPOL Annex I Examination · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3400412
30 November 2007
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3107145
6 February 2007
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2867665
2 February 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2866339
14 December 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2840209
23 October 2006
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2806451
11 October 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2798279
4 January 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2560642
28 November 2005
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2541531
12 July 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2424080
1 December 2004
Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2251070
9 December 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1961013
31 January 2003
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1737822
6 January 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1726491
5 January 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1727069
24 June 2002
Deficiency Check · Administrative Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1635838
4 April 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1601179
22 October 2001
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1439284
14 October 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1124560
4 October 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198503
4 October 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1352485
10 February 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792887
13 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 678281
23 January 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779737
29 April 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 145443
7 April 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1094189
6 April 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 495678
15 January 1997
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1101409
7 November 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193667
28 September 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192329
13 January 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829127
9 March 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855061
22 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852995
21 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163355
15 January 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870113
15 January 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133682
18 August 1992
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 931152
30 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254563
23 June 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268683
27 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959190
11 January 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234936
2 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932540
14 September 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917348
8 December 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 899034
8 December 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902158
18 October 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200429
26 November 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331047
27 August 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299161
17 July 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297598
15 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289698
17 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287234
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2023
Resolved
1 PORT: V/W missing stitch weld on 1st bottom longitudinal working inwards, where it meets the bilge knuckle.
Action required: 705 - Other - as specified
Due 31 August 2026
Resolved 16 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2021
Resolved
Pressure vessels shall be designed, constructed, and inspected in accordance with section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference, see 46 CFR 54.01-1).
Barge had a portable air compressor on board that is not ASME approved.
46 CFR 54.01-2(a)
14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 23 July 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 29 June 2021
Resolved
Cargo pump pressure gauge shall be tested at least once a year for accuracy; Each pressure gauge must show pressure within 10 percent of the actual pressure.
No proof of pressure gauge testing was provided.
46 CFR 35.35-70(c), 33 CFR 156.170(c)(3).
30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 June 2021
Resolved
Boilers, main and auxiliary machinery, and piping systems shall conform to the requirements of subchapter F (Marine Engineering) of this chapter. At each inspection for certification the marine inspector shall conduct such tests of auxiliary machinery as she feels necessary to check safe operation. Automatic shutdown shall occur under the following conditions: (i) overspeed, (ii) low lubricating oil pressure.
Marine inspector was unable to complete necessary tests due to inoperable gauges at the time of the inspection.
46 CFR 32.35-1, 46 CFR 61.20-3(a), 46 CFR 58.10-15(f)
30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2021
Resolved
Pressure vessels … must be stamped with the following information: Maximum allowable working pressure __ kPa (__ psig) at __ °C (__ °F).
The air receiver on deck has an illegible nameplate; MAWP is unknown.
46 CFR 54.10-20.
30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 29 June 2021
Resolved
Per IEEE Std. 45 (2002), incorporated by reference in 46 CFR 110.10-1(j)(5), range units should be sectional.
Range is not sectional.
46 CFR 110.10-1(j)(5), IEEE (2002) 45/19.1.1
30 days
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 July 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 17 September 2020
Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized.
Guards need to be placed on both Cargo Pump Engines over the exposed rotary belts.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2020
Resolved 15 October 2020
Resolution: Guards were installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2019
Resolved
01: Provide updated crew list for Drug and Alcohol Program
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 30 October 2019
Resolution: received crew list.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 October 2019
Resolved
02: Repair frayed armored cable on port running light
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 15 October 2019
Resolution: Vessel provided picture of repaired armored cable on port running light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2019
Resolved
03: Replace port side life buoy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 15 October 2019
Resolution: Vessel provided a picture and receipt of replaced life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 October 2019
Resolved
04: Relocate liferaft from the top of the accommodation house. To be completed at next drydock (31AUG2021).
Action required: 705 - Other - as specified
Due 31 August 2021
Resolved 7 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2018
Resolved
If the voltage of a distribution system is less than 1,000 volts, line to line, a tank vessel must not have a grounded distribution system. The main switchboard in the generator space has an amperes to ground meter and the meter is showing the presence of about 2 amps going to ground. Vessel to needs to determine where the ground is coming from, rectify the issue, and replace the system with an ungrounded system and have the proper ground detection installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2018
Resolved 19 November 2018
Resolution: Vessel installed new ground detection for tank vessel
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018
Resolved
As per regulation, the plans submitted to the Sector New York Inspections Office, dated 13 September 2018, to make a modification to the cargo tank opening shall be approved by the Coast Guard Marine Safety Center. While awaiting approval from MSC, the local OCMI will allow the vessel to proceed with the modifications and operate for a period of 30 days, from reciept of this CG-835V, with the understanding that if the intended modifications are not approved by MSC, the vessel's COI will be deactivated until the intended modifications are approved or other modifications required to obtain MSC approval are achieved.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 10 April 2019
Resolution: MSC approved the modifcations made to the barge, and has approved the new Hazardous Zone Plan for the barge as a result of the modifications made.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 19 August 2016
Resolved
Dryer and stove contain a floating neutral. Vessel must isolate the floating neutral with a transformer. The dryer and stove must be on separate transformers off of the distribution panel or replace each with suitable appliances. 46CFR111.05-15(a) and 46CFR111.05-19(a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 3 October 2016
Resolution: [name withheld] / [name withheld] verified deficiency, vessel has newly installed transformers for dryer and stove units. deficiency cleared.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 19 July 2016
Resolved
The 120 V distribution panel did not have a ground detection system installed. Install ground detection lights for this panel. 46CFR111.05-21(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 3 October 2016
Resolution: Ground detection installed to 120 V distribution panel. verified by MI's. def cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 19 July 2016
Resolved
The overspeed trip on the stbd generator failed to activate during testing. Prove proper operation to the satisfaction of the attending marine inspector. 46CFR111.12-1(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 3 October 2016
Resolution: Vessel crewmember demonstrated proper operation of overspeed shutdown on STBD generator. all operation, Def cleared.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 20 October 2014
Resolved
Ground detection is required on main power distribution panels, 480v, 240v and 120v. Submit electrical plans to USCG prior to installation of ground detection component. 46CFR111.05-21 (New CFR)
46CFR111.30-15(7) (Old CFR, 1952-1982)
Due 24 December 2014
Resolved 12 December 2014
Resolution: Verified the proper operation of ground detection system.
Electrical › Electric Generation Source (emergency) › Generator
Issued 27 October 2011
Resolved
Vessel must demonstrate proper operation of the outboard generator's overspeed and lube oil shut downs to comply with 46 CFR 111.12-1b&c
Action required: 705 - Other - as specified
Due 23 December 2011
Resolved 14 December 2011
Resolution: Vessel demonstrated proper shutdowns for both generators.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 October 2011
Resolved
Vessel's exposed steam lines have no protective insulation preventing burns to personnel. Vessel must wrap all exposed steam lines with insulation.
Action required: 705 - Other - as specified
Due 23 December 2011
Resolved 14 December 2011
Resolution: Vessel wrapped all steam lines with proper insulation.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 27 October 2011
Resolved
Vessel's anchor windless prime mover (2 cylinder diesel) does not operate. The anchor cannot be hoisted after dropped. Vessel must demonstrate proper operation of the anchor.
Action required: 705 - Other - as specified
Due 23 December 2011
Resolved 4 January 2012
Resolution: Witnessed proper operation of anchor windless.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 October 2011
Resolved
Vessel's # 5 & 6 P/S cargo dome inspection ports are missing gaskets. Vessel must install new gaskets.
Action required: 705 - Other - as specified
Due 23 December 2011
Resolved 14 December 2011
Resolution: Vessel installed new gaskets.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 2 February 2009
Resolved
Properly stencil cargo hoses w/OIL SERVICE ONLY and MAWP.
Action required: 705 - Other - as specified
Due 16 February 2009
Resolved 9 February 2009
Engineering › Compressed Air System (start air) › Piping
Issued 2 February 2009
Resolved
Vessel must install hard piping for use w/anchor winch motor air start. Vessel currently uses flexible hose.
Action required: 705 - Other - as specified
Due 31 October 2009
Resolved 15 September 2009
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 November 2005
Resolved
Lagging missing on Port cargo pump engine exhaust manifold.
Condition: Placed in Improper Service
Due 28 December 2005
Resolved 4 January 2006
Resolution: New lagging in place.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 November 2005
Resolved
Both generator engines exhaust manifolds missing lagging.
Condition: Placed in Improper Service
Due 28 December 2005
Resolved 4 January 2006
Resolution: New lagging in place.
Engineering › Fuel Oil Service System › Hose
Issued 28 November 2005
Resolved
Replace fuel hoses on the Port cargo pump engine.
Condition: Placed in Improper Service
Due 28 December 2005
Resolved 4 January 2006
Resolution: New fuel hoses in place.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 November 2005
Resolved
Provide lagging on Stbd Cargo Pump engine exhaust manifold.
Condition: Placed in Improper Service
Due 28 December 2005
Resolved 4 January 2006
Resolution: New lagging in place.
Lifesaving › Immersion Suits
Issued 9 December 2003
Resolved
T/B is required to have two immersion suits aboard. None were present during the inspection. Gellatly will be purchaing two suits and faxing a copy of the receipt to Marine Safety Operations - Cargo within thirty days.
Condition: Unknown
Due 9 January 2004
Resolved 29 December 2003
Resolution: Received invoice by fax.
Electrical › Lighting (service)
Issued 31 January 2003
Resolved
Work light located on port side of anchor winch inop. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 12 February 2003
Resolution: Light was deemed uneccessary and was removed.
Engineering › Pressure Vessel
Issued 31 January 2003
Resolved
Pressure relief valve on air receiver failed to operate as designed when hand lifted. Vessel crew not to exceed 125 psi on receiver until PRV has been repaired or replaced. LEGACY COMPONENT DESC: Air Receiver
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 12 February 2003
Resolution: Vsl installed new PV relief valve, hand tested, sat.
Navigation › Collision/Grounding Avoidance
Issued 31 January 2003
Resolved
Vessel's stern light inoperable. Vessel not permitted to transit beyond dusk until light has been repaired or replaced. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2003
Resolved 12 February 2003
Resolution: Stern light repaired and tested in presence of CG.
Fire Fighting › Firemans Outfit
Issued 31 January 2003
Resolved
Fireman's outfit missing. Vessel not permitted to sail manned until a proper outfit has been placed onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 12 February 2003
Resolution: Vsl purchased and presented full FF outfit to CG.
Documentation › Logs/Records
Issued 31 January 2003
Resolved
Vessel missing proof of annual calibration required for cargo pump pressure relief valves and associated gauges. LEGACY COMPONENT DESC: Cargo pump/PRV calibration records
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 12 February 2003
Resolution: Vsl provided logs showing cargo pump relief valve calibration & hydro test on pipelines and hoses.
Construction/Loadline › Hull
Issued 6 January 2003
Resolved
Fwd railing stbd side bent. Make permanent repairs to fwd railing, stbd side. Adjoining spaces must be gas freed before hotwork is performed. All repairs must be completed to satisfaction of USCG marine inspector. LEGACY COMPONENT DESC: Deck railings
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 February 2003
Resolved 31 January 2003
Resolution: Corrected. Company had forward railings removed.
Construction/Loadline › Structures
Issued 22 October 2001
Resolved
Provide USCG with corrected and professional engineer approved plans for vessel's general arrangement for as-built verification. LEGACY COMPONENT DESC: Superstructure
Due 14 February 2002
Resolved 15 April 2002
Resolution: Provided USCG with corrected/professional engineer approved plans for vessel''s general arrangements for as-built verification.
Personnel › Training
Issued 22 October 2001
Resolved
Train crew on use of combustible gas indicator and demonstrate that knowledge to a USCG marine inspector. LEGACY COMPONENT DESC: Cargo Safety
Due 14 February 2002
Resolved 15 April 2002
Resolution: Crew operated combustible gas meter to USCG MI''s.
Accommodation/Occupational Safety › Messroom
Issued 22 October 2001
Resolved
Permanently mount all galley equipment.
Condition: Improper Installation
Due 14 February 2002
Resolved 15 April 2002
Resolution: All galley equippent satisfactoriy mounted and bracketed down.
Documentation › Logs/Records
Issued 22 October 2001
Resolved
Provide receipt showing payment of user fees to marine inspection office. LEGACY COMPONENT DESC: User Fees
Condition: Unknown
Due 28 February 2002
Resolved 15 April 2002
Resolution: Provided copies of cancelled checks for user fees paid.
Electrical › Electric Generation Source (service)
Issued 22 October 2001
Resolved
Install and prove proper operation of tachometer for outboard generator. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 28 February 2002
Resolved 15 April 2002
Resolution: Observed operation of tachometer for outboard generator.
Engineering › Diesel Engine (auxiliary)
Issued 22 October 2001
Resolved
Install insulating blankets on both generator exhaust lines. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Design Flaw
Due 14 February 2002
Resolved 15 April 2002
Resolution: Observed insulating blankets on generator exhaust lines.
Accommodation/Occupational Safety
Issued 4 October 1999
Resolved
Make air receiver ready for hydro test in presence of USCG marine inspector.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Electrical
Issued 4 October 1999
Resolved
Prove proper operation of #2 generator power available light.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Fire Fighting
Issued 4 October 1999
Resolved
Provide proof of servicing for portable firefighting equipment.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Documentation
Issued 4 October 1999
Resolved
Provide original COFR & COI for review.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Deck/Cargo
Issued 23 January 1998
Resolved
PROVIDE PROOF OF HYDROSTATIC TESTING FOR CARGO PIPING ON BOARD. CORRECT PRIOR TO CONDUCTING CARGO TRANSFERS.
Condition: Unknown
Due 23 February 1998
Resolved 12 February 1998
Deck/Cargo
Issued 23 January 1998
Resolved
PROPERLY STENCIL ALL CARGO HOSES WITH PROPER MARKINGS "HAZARDOUS MATERIALS".
Condition: Unknown
Due 23 February 1998
Resolved 12 February 1998
Deck/Cargo
Issued 15 January 1997
Resolved
PROVE PROPER OPERATION OF PORT SIDE CARGO PUMPS AND SHUTDOWNS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 March 1997
Resolved 31 March 1997
Electrical
Issued 28 September 1995
Resolved
CONNECTION BOX FITTINGS/WIRING ARMOR LOOSE ON AFT FLOODLIGHTS FORWARD OF TANKS 5 P&S. RENEW PACKING MATERIAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Electrical
Issued 28 September 1995
Resolved
REWIRE EXPLOSION PROOF LIGHT ON STBD OUTBOARD HANDRAIL STANCHION IWO #3 STBD DOUBLE BOTTOM HATCH. RENEW PACKING MATERIAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Construction/Loadline
Issued 15 January 1993
Resolved
COMPLETE INTERNAL STRUCTURAL EXAM NO LATER THEN 02MAR94.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993
Lifesaving
Issued 11 January 1991
Resolved
LABEL RING BUOYS WITH VESSELS NAME.
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Electrical
Issued 11 January 1991
Resolved
INSTALL GLOBE GUARDS FOR DECK LIGHTING IN WAY OF HOUSE, FWD.
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Deck/Cargo
Issued 11 January 1991
Resolved
CLEAN OR RENW ALL VENT SCREENS.
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Deck/Cargo
Issued 17 June 1985
Resolved
RENEW THE SHORT PIECES OF FLEXIBLE FUEL LINE THAT ARE CONNECTED TO THE FUELFILTERS OF THE TWO CARGO PUMPS, THE WASH DOWN PUMP AND THE SHORT PIECE AT THE BOTTOM OF THE AIR COMPRESSOR PUMP WITH FLEXIBLE HOSE OR TUBING IN ACCORDANCE WITH 46 CFR 56.50-75.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985