NA PALI KAI is a 1985 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in July 2026, along with 20 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 July 2026.

Built
1985
Last inspected
1 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY6965
253143
Flag
UNITED STATES
Maury page id
psix-253143

Documentation record

Registered dimensions (L × B × D)33.8 ft × 11.0 ft × 5.0 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIGHTNIN FIBERGLASS · KILAUEA, HI, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

1 July 2026 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8426416
17 June 2026 Deficiency Check · In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8433249
2 May 2025 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8127049
21 January 2025 Drydock Exam · Examination of Repairs
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8067730
2 August 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7961731
20 May 2024 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7922037
7 September 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7787323
26 June 2023 DAPI Audit · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7724433
21 February 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7641145
13 July 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7505851
9 June 2022 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7519964
1 September 2021 Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7346210
29 April 2021 Annual Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7181631
8 February 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7137626
5 February 2021 In-Service Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7136163
28 April 2020 COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6945391
31 July 2019 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6768009
31 July 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6532389
16 April 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6423030
2 May 2017 Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6136746
15 May 2016 Hull Examination · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913865

Deficiency record · 20

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 July 2026 Resolved
Pre-engineered gas system not meeting the following requirement: -Must shut-down power ventilation systems upon discharge. Must make repairs to satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2026
Resolved 2 July 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2026 Resolved
Port shaft sheared causing a loss of the port propeller. Vessel operator must make necessary repairs to port propulsion system to satisfaction of USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 May 2025 Resolved
Must replace gasket on watertight hatch to lazeretted space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 16 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 August 2024 Resolved
Vessels on limited coastwise routes are required to carry six (06) red and six (06) orange flares or twelve (12) red flares. Three (03) red flares are expired by two months at the time of the inspection. Must replace expired flares with current approved flares.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2024
Resolved 2 August 2024
Resolution: Pictures emailed to rectify def.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 June 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for EPIRB expired. Install new hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2023
Resolved 26 June 2023
Resolution: new installation
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 June 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent extent necessary to determine that they are in suitable condition and fit for the service intended.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2023
Resolved 26 June 2023
Resolution: Inspected and no longer leaking
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2023 Resolved
Machinery and fuel tank spaces must be separated by boundaries that prevent the passage of vapors. The portside has a hole in the bulkhead to the outside that is not a ventilation openings, the penetration is not vapor tight. Provide a proper seal to prevent loss of FM 200 upon future activation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2023
Resolved 26 June 2023
Resolution: hole made vapor tight, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. 15 life jackets had faded retro tape. New approved retro tape must be installed to life jackets. Reduced passenger count by 15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2023
Resolved 26 June 2023
Resolution: all retro was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The port side engine had one rusted, bursting, cracking fuel hose. Must install new hose with fitting in accordance with 46 CFR 182.720
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2023
Resolved 26 June 2023
Resolution: New hose with fitting installed and met regs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 July 2022 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. No stern light. Provide navigation lights that are in compliance with the Navigation Rules. Due no later than 27 July 2022.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: New stern light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2022 Resolved
Fuel tanks and fittings must be so installed as to permit examination or removal for cleaning with minimum disturbance to the hull structure and fuel shutoff valves installed at the tank connection. Shut off valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Fuel tank is not accessible for inspection and no fuel shutoff valve installed on the tank.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 21 February 2023
Resolution: Two new fuel shut off valves installed and considered satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2021 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. The vessel's starboard side emergency fuel shut is inoperable. Please make permanent repairs to the starboard side emergency fuel shut.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Permanent repairs to the starboard side emergency fuel shut and it is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2021 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The vessel's EPIRB has an expired hydrostatic release unit and needs to be replaced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 29 April 2021
Resolution: The vessel's EPIRB hydrostatic release was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2021 Resolved
Connections must be made to battery terminals with permanent type connectors. Replace wing nuts on the battery terminals.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 29 April 2021
Resolution: The wing nuts on the battery terminals where removed and replaced with nuts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2021 Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. One of the three required child life jackets was removed due to the poor condition. The life jacket needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 29 April 2021
Resolution: The child life jacket was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 29 April 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The bilges where oily and need to be cleaned.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 1 September 2021
Resolution: The oil in the bilges where cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2021 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. The vessel allided with the pier and the impact broke the mount holding the steering ram. The vessel lost steering and had a ½ inch breech in the hull. The vessel needs to make permanent repairs to the steering mount and hull fracture.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2021
Resolution: The vessel maked permanent repairs to the steering mount and hull fractures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2019 Resolved
Replace SOLAS tape on 03 adult and 02 child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 15 August 2019
Resolution: Marine Inspector verified new retroflective tape on life jackets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 July 2019 Resolved
Provide ammonia inhalants in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 15 August 2019
Resolution: Marine Inspector verified ammonia inhalants in first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2019 Resolved
Provide visual indicator on bilge high level alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2019
Resolved 15 August 2019
Resolution: Marine Inspector verified visual indicator of bilge high level alarm on helm.