Documentation record
Registered dimensions (L × B × D)65.0 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 63 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTUART, FL, UNITED STATES · built 1985
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWBURYPORT, MA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
16 March 2026
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8327250
2 October 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8243494
24 September 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8003186
5 February 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7853378
28 September 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7787602
2 May 2023
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668519
22 September 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7546319
28 September 2021
Annual Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7314430
15 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7077095
24 October 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6835558
3 October 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6824408
4 October 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6554180
12 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6539051
13 October 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6286801
25 September 2017
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6272443
4 October 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6014873
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 October 2025
No resolution recorded
The float-free link required by § 180.130(a)(1) must be certified to meet 46 CFR 160.073 and of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Each link certified by the manufacturer to meet the requirements of this subpart must have a corrosion resistant, waterproof tag attached to it. Weak link tag for 21 or more persons is missing from 22-person life floats. 705: Limited to within 1 mile of shore.
46 CFR 180.137(b)
46 CFR 160.073-20
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. The 10-B:C portable fire extinguisher at the operating station was missed during the 2025 annual servicing.
46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 16 October 2025
Resolution: New 10-B:C extinguisher placed at operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 15 October 2020
Resolved
Life floats and buoyant apparatus must not be stowed
in tiers more than 1,220 millimeters (4 feet) high.
When stowed in tiers, the separate units must be kept
apart by spacers. No spacers between life floats.
Action required: 10 - Deficiency Rectified
Resolved 15 October 2020
Resolution: Spacer provided and properly installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 October 2020
Resolved
Every vessel subject to Part III of Title III of the
Communications Act must have a detailed inspection
of the radio installation by an FCC-licensed technician
in accordance with §80.59 once every five years.
Official number on vessels safety certificate is not
accurate. Provide accurate certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 4 November 2020
Resolution: New radio certificate recieved and verified.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 October 2020
Resolved
Fire fighting drills and training shall be logged or
otherwise documented for review by the Coast Guard
upon request. The drill entry shall include the following
information:
(1) Date of the drill and training; and
(2) General description of the drill scenario and
training topics. No drill logged on vessel. Provide
vessel log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 4 November 2020
Resolution: Drill sheets provided with properly log entries.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2020
Resolved
Each vessel must—
(1) Have permanent draft marks at each end of the
vessel; no draft marks on vessel.
Vessel has no visible forward or aft draft marks.
Provide draft markings at vessels next dry dock.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 4 November 2020
Resolution: Draft marks painted on vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Investigation after accident
Issued 4 October 2018
Resolved
Alcohol testing of each individual must be conducted within 2 hours of when the Serious Marine Incident (SMI) occurred. Vessel does not have means of testing onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2018
Resolved 10 October 2018
Resolution: Alcohol test strips onboard the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 October 2018
Resolved
Where cable protection is carried through watertight decks or bulkheads, installations shall be such that will insure watertight integrity of the structure.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2018
Resolved 10 October 2018
Resolution: Bulkhead penetrations filled using a fire retardant foam.
Lifesaving › Lifefloat › Pendant
Issued 25 September 2017
Resolved
Replace pendents of line on life float; port side bottom as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 13 October 2017
Resolution: Pendants replaced
Engineering › Fuel Oil Service System › Tank
Issued 25 September 2017
Resolved
Install bonding wire on STBD fuel tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 13 October 2017
Resolution: Bonding wire installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 4 October 2016
Resolved
During Test of Pre-engineered Fire suppression system,engine shutdown failed to function properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: Proved proper operation of engine shutdown for installed pre-engineered system.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 October 2016
Resolved
Waterlight on Ring buoy not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2016
Resolved 24 October 2016