Records from 1985 to 2009. Most recent: inspection, 13 January 2009.
Inspection history · 26
13 January 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3393114
16 December 2008
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3380485
14 March 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2887791
2 October 2006
MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791125
13 July 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2711940
5 December 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2546237
8 August 2005
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2454477
18 October 2004
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2222946
16 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2222376
6 February 2003
Security Inspection · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740789
4 February 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1746716
23 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 286377
19 June 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 279141
24 March 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 426862
9 September 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 420120
11 June 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 416837
14 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 142131
9 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405450
22 December 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 386410
13 June 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 646805
3 June 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 379037
12 June 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 516984
10 June 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 462596
7 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339151
12 August 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 519042
9 August 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 303546
Lifesaving › Immersion Suits › General
Issued 16 December 2008
Resolved
Crew unable to don type HYF-1 immersion suits in way of boot fittings due to suit design. These suits must be replaced with suits which meet requirements of SOLAS Cons. Ed. 2004 III/7.3.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 13 January 2009
Resolution: Received proper documentation satisfying requirement.
Fire Fighting › Firemans Outfit › Lifeline
Issued 6 February 2003
Resolved
FIREMAN OUTFIT IS NOT OUTFITTED WITH A FIREPROOF LIFELINE LEGACY COMPONENT DESC: Lifeline
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2004
Resolution: Verified by CG PSC inspector.
Construction/Loadline › Structures
Issued 6 February 2003
Resolved
1) CRACK IN DECK ACCESS IN #3 HOLD, LOCATED PORT SIDE, MANHOLE TRUNK.
2) HORZONTAL SUPPORT BAR, LOCATED PORT SIDE #3 HOLD.
3) STBD SIDE TO #3 HOLD CRACK IN DECK NEXT TO HOUSE. LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2003
Resolved 6 February 2003
Resolution: Corrected to the satisfaction of class
Engineering › Bilge Water Management System › Pump
Issued 6 February 2003
Resolved
PIN HOLE LEAK IN DISCHARGE PIPE TO BILGE PUMP. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2004
Resolution: Verified by CG PSC boarding officer.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 6 February 2003
Resolved
REPLACE FLAME SCREENS ON ALL TANKS AND REPAIR VENT HEAD STBD SIDE #1 DIESEL OIL TANK AND #3 BUNKER FUEL TANK,AND #2 BUNKER FUEL TANK. LEGACY COMPONENT DESC: Flame Arrester
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2004
Resolution: Verified by CG PSC boarding officer.
Deck/Cargo › Holds/Tanks › Hatch
Issued 6 February 2003
Resolved
BROKEN/MISSING DOGS ON #2 HOLD SUPPLY VENTILATION COVER. LEGACY COMPONENT DESC: Ventilation Air Intake
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2003
Resolved 18 October 2004
Resolution: Verified by CG PSC boarding officer.
Engineering
Issued 11 June 1998
Resolved
Provide mechanical drain plugs for all containment areas prior to entry into next U.S. port after sailing foreign. 33 CFR 155.320
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Accommodation/Occupational Safety
Issued 11 June 1998
Resolved
Repair leaking water closet in hospital space prior to entry into next_x001C_ U.S. port after sailing ILO 147.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Lifesaving
Issued 11 June 1998
Resolved
Remove all insecticides/poisons from medicine locker and stow properly prior to entry into next U.S. port after sailing foreign. ILO 147.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Accommodation/Occupational Safety
Issued 11 June 1998
Resolved
Repair door to fish locker so that it closes and latches properly prior to entry into next U.S. port after sailing foreign. ILO 147.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Engineering
Issued 11 June 1998
Resolved
Repair leaks in ship service generators and clean excess oil from generatorflat prior to entry into next U.S. port after sailing foreign. SOLAS 74 amd II-2/15.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Accommodation/Occupational Safety
Issued 11 June 1998
Resolved
Repair deck in front of freezers to prevent tripping hazard prior to entry into next U.S. port after sailing foreign. ILO 147.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Fire Fighting
Issued 22 December 1995
Resolved
AFT PORT SIDE FIRE HOSE HAD NUMEROUS LEAKS.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 22 December 1995
Resolved
PORT SIDE HAS ONE INCH HOLE IN MAIN DECK NEAR NO. 1 CARGO TANK.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Lifesaving
Issued 22 December 1995
Resolved
STBD MOTOR LIFEBOAT FAILED TO START.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Fire Fighting
Issued 22 December 1995
Resolved
NEW SPRINKLER SYSTEM INSTALLED IN PAINT LOCKER NOT REFLECTED ON FIRE CONTROL PLAN.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Fire Fighting
Issued 22 December 1995
Resolved
FIREMAIN AFT OF HOLD #2 ON PORTSIDE LEAKING DUE TO CORROSION.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Navigation
Issued 3 June 1995
Resolved
The M/V SINCERE OCEANUS transited Puget Sound shipping channels and did nothave the required working frequency,(Channel 5-A) as stated in 33 CFR 161.112.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997