← All vessels
SHADY LADY
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named SHADY LADY
SHADY LADY is a 1985 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1985, most recently in February 2026, along with 199 deficiencies and 2 operational controls.
Records from 1985 to 2026. Most recent: inspection, 18 February 2026.
- Built
- 1985
- Last inspected
- 18 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 199 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
681969
WDI5475
253456
Flag
UNITED STATES
367563370, 367649440, 367708940 (licence lapsed)
Maury page id
psix-253456
Inspections, by type
…with no type recorded9
Years with a record
39 calendar years (1985–2026)
The 98 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)56.3 ft × 18.6 ft × 7.5 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE, INC · PANAMA CITY, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI5475MMSI 367708940 · expired · compulsorily equipped · granted 5 January 2016, cancelled 7 March 2026
WDH7572MMSI 367649440 · expired · voluntarily equipped · granted 9 December 2014, cancelled 8 February 2025
WDG7048MMSI 367563370 · expired · compulsorily equipped · granted 21 February 2013, cancelled 29 April 2023
WAK2396MMSI not assigned · expired · compulsorily equipped · granted 3 June 1996, cancelled 5 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 98
18 February 2026
Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8303412
8 October 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8249479
9 September 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7999493
4 December 2023
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7833350
7 November 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7823954
2 October 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7801933
1 August 2023
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7797972
28 June 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7725528
18 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7670953
27 September 2022
In-Service Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7544234
27 October 2021
Administrative Inspection · Annual Inspection · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7340931
13 September 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7334722
27 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7211874
3 December 2020
Administrative Inspection · Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7105834
8 January 2020
Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6885426
18 September 2019
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814670
25 February 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6631757
8 January 2018
Hull Examination · DAPI Audit · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6334161
30 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6160823
26 April 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6133372
25 February 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6094537
13 July 2016
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 5939932
23 March 2016
Simplified Stability Test · Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5846603
10 March 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5831055
1 December 2015
Administrative Inspection · Internal Structural Exam · Hull Examination · Annual Inspection · Deficiency Check · Examination of Repairs · Plan Review "T" Boat · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5773766
19 December 2011
COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4211114
9 March 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3692334
22 April 2009
Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3459592
20 February 2009
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3421196
17 February 2009
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3419268
10 March 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3157649
14 February 2008
Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3148214
31 January 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2864646
16 January 2007
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2856286
19 August 2006
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 2795034
21 February 2006
Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2644105
15 February 2006
Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2585901
7 February 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2564377
27 July 2005
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2441773
3 January 2005
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2268024
3 March 2004
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2000248
10 February 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2005029
30 December 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1971443
4 February 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1742520
23 October 2002
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1695299
23 October 2002
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1736078
22 October 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1695443
2 April 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1602630
7 March 2002
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491176
1 February 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1482202
11 April 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1062958
20 February 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060073
11 February 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815334
9 February 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 814182
9 February 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465531
11 January 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434980
23 September 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 814181
19 July 1999
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 815534
19 July 1999
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1464883
17 July 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 118206
15 April 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1440170
22 February 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 811573
12 November 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 806272
10 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 806490
10 February 1998
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421472
1 May 1997
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392694
19 June 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1088412
15 May 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380505
11 March 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 885432
7 February 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447528
31 July 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1184570
24 April 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1450965
4 May 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 874456
3 May 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168705
1 February 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162094
10 May 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837113
10 November 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825709
27 April 1992
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 959308
14 April 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955559
19 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 910156
20 May 1991
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909288
12 February 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 915463
14 November 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 929880
6 September 1990
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 917862
27 June 1990
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 904621
30 May 1990
Drydock Extension · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1215794
21 May 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 928675
31 August 1989
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341838
16 June 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 890805
30 November 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1207597
3 August 1988
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1343279
8 June 1988
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 892513
9 June 1987
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338479
3 February 1987
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1004247
6 August 1986
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 987272
4 August 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985818
8 July 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1300944
13 June 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1291639
Deficiency record · 199
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2025
Resolved
All wiring shall be run as high as practicable above bilges. MI observed yellow grounding wire connected between Port and STBD engine starters unsupported running along floor in engine room. Submit repair proposal on rerouting wire.
46 CFR 183.10-20(d) [Old T]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 September 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.MI observed exposed wiring in pilot house overhead, starboard accommodation closet space and salon passageway.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 September 2024
Resolved
An existing vessel must comply with the subdivision, damage stability, and watertight integrity regulations
which were applicable to the vessel on March 10, 1996, or, as an alternative, the vessel may comply with the regulations in this part. Vessel's forward emergency escape hatch was found leaking. Provide plans to either make sufficient repairs, replace in kind, or install new hatch complying with 46 CFR 179.360.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2024
Resolved
Tanks may not have any openings in bottoms, sides, or ends, except for: An opening fitted with a threaded plug or cap installed for tank cleaning purposes; and, openings for supply piping and tubular gauge glasses. Cleaning ports on independent fuel tanks were found to have a flexible fuel hose connecting port and starboard tanks. Remove hose and install threaded cap into tank opening.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 October 2023
Resolved
Vessel only had 01 life float on board. The second one is ashore for repairs. Vessel has been restricted to carry a maximum of 20 PAX
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2023
Resolved
24 adult life jackets did not have approved SOLAS retro tape. Vessel has been restricted to 22 passengers
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 September 2022
Resolved
Weak link was incorrectly attached to life floats, both vessel and LF painter were connected to the same side of the weak link. Vessel limited to operations within 03 NM.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 September 2022
Resolved
Smoke detectors in passenger overnight accommodation spaces were expired or inop due to insufficient battery charge. Rectify prior to overnight passenger operations.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 September 2022
Resolved
The number of passengers allowed on the upper deck was not marked clearly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 September 2022
Resolved
Stern light and anchor light were inop. Correct prior to nighttime ops.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2022
Resolved
Electrical outlet on fantail of vessel was removed due to corrosion, leaving dead end wires in an exposed location.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 December 2021
Resolved
Hinges on engine room vent closure broken
182.465(h)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 December 2021
Resolved
Bilge hand pump non-operational
46CFR182.520(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2021
Resolved
Electrical panel in machinery space was not properly labled for usage. All electrical equipment and circuits must be clearly marked and indentified.
46 CFR 183.220(d)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2021
Resolved
Anchor light was inoperable at time of inspection. All vessels must have navigation lights that are in compliance with the applicable sections of the inland nav rules. Vessel is restricted to day time operations only.
46 CFR 183.420
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2021
Resolved
Life jackets had retro reflective tape that is in need of replacement on 20+ life jackets.
Each life jacket must be marked with Type 1 retro reflective material approved in 46 CFR 164.018.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 October 2019
Resolved
Informed the Captain that he was not allowed to sail until he acquired a temporary EPIRB while his was sent out for a new battery.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 February 2019
Resolved
Vessel Does not have voyage plan. Provide means for voyage plan.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 25 February 2019
Resolved
Vessel does not have waste management plan. Provide means for waste management plan.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2019
Resolved
Portable extinguisher on bridge was not inspected. Provide evidence of portable extinguisher inspection.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 February 2019
Resolved
Navigation Chart for intended area of operation missing. Provide adequate charts for safe navigation in area of operation.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 25 February 2019
Resolved
Portable hand bilge pump hose length insufficient to reach bilge. Add hose extension to meet requirement.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 April 2017
Resolved
Link GPS to DSC on VFH radio IAW 46 CFR 184.502
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 March 2017
Resolved
EAP training must be conducted for crewmembers and supervisory personnel. Provide documentation to satisfy requirements have been met.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 23 March 2017
Resolved
SSB radio is required for vessels route. Re-install SSB radio or obtain FCC exemption certificate. Limited to less than 20NM from shore.
Stability › Watertight Integrity › General
Issued 23 March 2017
Resolved
Seal wiring in engine room where wires run thru bulkheads.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 23 March 2017
Resolved
Water leak on port main engine near R/G cooloer and oil leak at starboard engine inboard oil line. Repair or replace.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 January 2016
Resolved
COD, FCC Station license, FCC Safety Certificate, EPIRB registration did not
reflect updated owner’s information. Provide these documents with the updated
owner’s information IAW 46 CFR 67 and 47 CFR 80
Documentation › Certificates/Documents › FCC SSL
Issued 5 January 2016
Resolved
Current owner/Captain did not provide FCC operators permit. Provide FCC
operators permit IAW 47 CFR 80
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 January 2016
Resolved
COI was not posted. Post COI in a public area IAW 46 CFR 176.302
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 January 2016
Resolved
No light list or coastal pilot found on board. Provide light list and coastal pilot
IAW 46 CFR 184.420
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 January 2016
Resolved
There were no updated or appropriate charts for the vessel’s area of operation
on board. Obtain and make available for inspection updated charts IAW 46
CFR 184.420.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 January 2016
Resolved
There was no proof that either the master or the crewmembers are enrolled in a
random drug testing program with the vessel’s company or EAP. Enroll all
employees in a random drug testing program and provide EAP training
certification IAW 46 CFR 16.230 and 16.401
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2016
Resolved
There were dead ended wires under the operating station console. Properly
remove or cap wires to prevent electrical hazard IAW 46 CFR 183.340.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2016
Resolved
There were dead ended wires on topside of the pilot house. Properly remove or
cap wires to prevent electrical hazard IAW 46 CFR 183.340.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 5 January 2016
Resolved
Safety chain at top of ladder going to pilot house was missing. Provide chain
IAW 46 CFR 177.920
Lifesaving › Lifebuoys › Immediately Available
Issued 5 January 2016
Resolved
Life ring buoy was not easily accessible. Reconfigure to allow quick access
IAW 46 CFR 180.70
Engineering › Fuel Oil Service System › Piping
Issued 5 January 2016
Resolved
Fuel line in lazarette was loose. Secure fuel line with appropriate supports
IAW 46 CFR 182.455
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2016
Resolved
Loose hanging wires found in the lazarette. Bundle and secure wires IAW 46
CFR 183.10-20
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2016
Resolved
Broken wire found in lazarette. Properly reconnect broken wires IAW 46 CFR
183.340
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2016
Resolved
Found disconnected ground in lazarette. Reconnect ground IAW 46 CFR
183.372
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 January 2016
Resolved
A/C pump on Port side was not secure. Properly secure pump IAW 46 CFR
176.800
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 January 2016
Resolved
Helium tank not secure for sea. Properly secure tank IAW 46 CFR 176.800
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 January 2016
Resolved
Short six life jackets. Provide missing life jackets IAW 46 CFR 180.71 Reduce passenger count to 34 until resolved.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 January 2016
Resolved
Did not conduct underway drills as no deck has been hired for the season.
Conduct drills prior to carrying passengers IAW 46 CFR 185.520
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 January 2012
Resolved
Currently the anchor light is not operating. Prove proper operation of the anchor light as per 46 CFR 183.420.
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 January 2012
Resolved
Currently the magnetic compass light is not operating. Prove proper operation of the magnetic compass light as per 46 CFR 184.402.
Navigation › Piloting/Steering › Marine Charts
Issued 3 January 2012
Resolved
Currently there are no marine charts for the operating area onboard. Provide current and corrected marine charts (large enough for safe navigation) for the operating area as per 46 CFR 184.420
Electrical › Electric Supply System (service) › Cable
Issued 3 January 2012
Resolved
Currently there is a dead end wire coming out of the distribution panel located in the engine room on the forward, starboard side. Remove wire as per 46 CFR 176.800.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 3 January 2012
Resolved
Provide emergency training and drill logs as required by 46 CFR 185.520
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 3 January 2012
Resolved
Currently there is no life saving equipment maintenance log onboard as required by 46 CFR 185.700 and 185.728. Provide the same.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 January 2012
Resolved
Currently the exhaust muffler on the ship service generator is leaking exhaust gases into the engine room. Repair exhaust piping as required by 46 CFR 176.800
Engineering › Bilge Water Management System › Pump
Issued 3 January 2012
Resolved
Currently the electric submersible bilge pumps are not mounted properly to have access to the strainer. Properly mount and properly wire in a water tight junction box as per 46 CFR 176.800
Engineering › Bilge Water Management System › Pump
Issued 3 January 2012
Resolved
Currently the forward bilge pump in the lazarette is not operating. Prove proper operation as required by 46 CFR 182.500.
Engineering › Steering Gear System › Ram
Issued 3 January 2012
Resolved
Currently the steering ram mounting bracket is loose. Properly mount the same as per 46 CFR 176.800
Communications › Public Address System › Announcing Station
Issued 19 December 2011
Resolved
Currently the public address announcement cannot be heard in the accommodation space. Prove proper operation of the public address system as per 46 CFR 184.610.
Personnel › Training › Ship's Business
Issued 19 December 2011
Resolved
Currently there are no training records/logs as required by 46 CFR 185.420.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 10 March 2010
Resolved
Replace gasket for lazarette manhole cover.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 March 2010
Resolved
Install valve in plugged hull penetration on stbd eng room.
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2010
Resolved
Make repairs to the hull, approx 3 blisters.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 22 April 2009
Resolved
Provide handles for emergency fuel shut-off per 46 CFR 182.455.
Engineering › Steering Gear System › Rudder
Issued 22 April 2009
Resolved
Provide and install proper rudder stops per 46 CFR 182.600.
Engineering › Steering Gear System › Fastener
Issued 22 April 2009
Resolved
Properly install the tiller arm bolts per 46 CFR 182.600. Bolts are currently inverted.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 April 2009
Resolved
Replace 3 adult and 1 child life jacket that were rejected. Vessel shall not operate with more than 41 total adults on board until cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 March 2008
Resolved
Prove proper operation of stern and side navigation lights as per 46 CFR 183.420
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 March 2008
Resolved
Provide NOAA registration for EPIRB as per 46 CFR 185.604
Communications › Audible Communications › Horn/Whistle
Issued 10 March 2008
Resolved
Provide a whistle or horn as per 33 CFR 86.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 March 2008
Resolved
Provide chain to cross upper deck railing where ladder meets upper deck as per 46 CFR 177.900.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 March 2008
Resolved
Provide a lifesaving equipment maintenance manual as per 46 CFR 185.702.
Lifesaving › Hand Flares › Not on Board
Issued 10 March 2008
Resolved
Provide 02 red hand flared as per 46 CFR 180.68.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2008
Resolved
Provide a cover for the light in forward passenger berthing as per 46 CFR 176.800.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 March 2008
Resolved
Provide a list for the first aid kit as per 46 CFR 184.710.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 10 March 2008
Resolved
Prove operation of smoke detector in 'master berthing' in passenger area (aft of two detectors) as per 46 CFR 176.800
Stability › Unintentional Flooding › General
Issued 10 March 2008
Resolved
Plug all unused through hull fittings in the forward engine room as per 46 CFR 179.350.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 10 March 2008
Resolved
Repair the port side emergency light in the engine room so it lights as per 46 CFR 176.800.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 March 2008
Resolved
Repair/replace the outboard starboard main engine battery box, and secure it, and secure the generator batter box as per 46 CFR 183.350.
Stability › Unintentional Flooding › General
Issued 10 March 2008
Resolved
Remove water from the aft compartments in the engine room as per 46 CFR 176.800.
Engineering › Fuel Oil Service System › Piping
Issued 10 March 2008
Resolved
Replace the non-metallic fuel return hose on the starboard main engine as per 46 CFR 182.455.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 March 2008
Resolved
Replace the non-metallic exhaust cooling hose on the starboard main engine as per 46 CFR 182.425.
Lifesaving › Lifefloat › Serviceable
Issued 10 March 2008
Resolved
Replace the condemned life float as per 46 CFR 18.137.
Lifesaving › Lifefloat › Serviceable
Issued 10 March 2008
Resolved
Repair/replace the other life float, repairs to include all the black line and netting as per 46 CFR 180.137.
Lifesaving › Lifebuoys › Serviceable
Issued 10 March 2008
Resolved
Replace the grab line and reflective tape on the life ring as per 46 CFR 180.70.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 14 February 2008
Resolved
Provide and install rudders and propellers prior to refloating the vessel.
Documentation › Certificates/Documents › FCC SSL
Issued 16 January 2007
Resolved
Provide an FCC Station License in accordance with 47 CFR 80.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 16 January 2007
Resolved
Provide an FCC Radiotelephony Safety Certificate in accordance with 47 CFR 80.
Documentation › Logs/Records › Logbook (official)
Issued 16 January 2007
Resolved
Provide a current bridge log in accordance with 46 CFR 185.520.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 16 January 2007
Resolved
Provide an Emeregency Instruction List in accordance with 46 CFR 185.510.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 January 2007
Resolved
Provide a current U.S. Coast Pilot [name withheld] List, Tide Table, and Tidal Current Table in accordance with 46 CFR 184.420.
Communications › Radio Communications › EPIRB
Issued 16 January 2007
Resolved
Prove servicing and registration EPIRB in accordance with 46 CFR 185.604.
Construction/Loadline › Structures › Manhole
Issued 16 January 2007
Resolved
Make Escape hatch operable from both sides in accordance with 46 CFR 177.500.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 January 2007
Resolved
Prove the ability to recover an unconcious person from the water in way of a rescue platform in accordance with 46 CFR 180.210.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 January 2007
Resolved
Provide a Coast Guard approved First Aid Kit in accordance with 46 CFR 184.710.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 January 2007
Resolved
Properly mount the Auto Pilot and clean the area around it in accordance with 46 CFR 183.320.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 January 2007
Resolved
Prove proper operation of emergency lights in accordance with 46 CFR 183.432.
Construction/Loadline › Structures › Deck Plating
Issued 16 January 2007
Resolved
Fill in the holes on the 01 deck where an old antenna was mounted in accordance with 46 CFR 176.802.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 16 January 2007
Resolved
Properly stencil the Emergency Exit in accordance with 46 CFR 185.510.
Lifesaving › Lifefloat › Float-free Link
Issued 16 January 2007
Resolved
Prove the weak link on the sea painter for the lifefloat in accordance with 46 CFR 180.137.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 January 2007
Resolved
Provide two adult and one child size lifejacket to meet the requirements of your COI. Total amount of passengers is reduced to 40 and only 4 children may be carried until you have met the lifejacket requirement as stated on your COI in accordance with 46 CFR 180.71.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 January 2007
Resolved
Conduct drills in the presence of a Coast Guard Marine inspector in accordance with 46 CFR 185.520.
Engineering › Fuel Oil Service System › Filter
Issued 21 February 2006
Resolved
Replace plug in the fuel filter on the ship service generator in accordance with 46 CFR 182.455.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 21 February 2006
Resolved
Replace valve handle on the sewage discharge valve and ship service generator through hull fitting in accordance with 46 CFR 176.610.
Stability › Watertight Integrity › General
Issued 21 February 2006
Resolved
Make aft engine room bulkhead watertight in accordance with 46 CFR 179.360.
Construction/Loadline › Hull › Hull Plating
Issued 21 February 2006
Resolved
Make proper repairs to gouges in the hull in way of the ladder by grinding and using appoved fiberglass repair methods in accordance with NVIC 8-87.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 February 2006
Resolved
Remove diesel from bilge and lazarette in accordance w/ 46 CFR 176.830.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 February 2006
Resolved
Properly support and secure the steering hydraulic lines in the lazarette in accordance with 46 CFR 183.340.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 February 2006
Resolved
Provide current certificate of documentation.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 February 2006
Resolved
Provide current Coast Pilot [name withheld] and Tidal Current Tables.
Construction/Loadline › Structures › Door
Issued 7 February 2006
Resolved
Replace broken door in main cabin.
Construction/Loadline › Penetrations › Gasket
Issued 7 February 2006
Resolved
Replace gasket on accommodation space on emergency escape hatch.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 February 2006
Resolved
Provide retro reflective tape on life jackets where needed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 February 2006
Resolved
Provide eye wash in first aid kit.
Engineering › Steering Gear System › Rudder
Issued 7 February 2006
Resolved
Repack port and starboard rudders.
Engineering › Gas Turbine (propulsion/auxiliary-electric) › Enclosure
Issued 7 February 2006
Resolved
Replace guard on alternator starboard engine.
Engineering › Freshwater Generation System › Heat Exchanger
Issued 7 February 2006
Resolved
Replace raw water hoses on generator sea suction.
Engineering
Issued 4 February 2003
Resolved
Make all overboard discharges double clamped on starboard side of engine room LEGACY COMPONENT DESC: piping systems
Construction/Loadline › Structures
Issued 4 February 2003
Resolved
Make aft bulkhead of engine room on starboard side vapor tight. LEGACY COMPONENT DESC: End Bulkhead
Documentation › Markings/Placards
Issued 4 February 2003
Resolved
Post oil pollution placard LEGACY COMPONENT DESC: Oil Discharge Placard
Construction/Loadline › Structures
Issued 4 February 2003
Resolved
Make forward bulkhead of engine room starboard side vapor tight.
Communications › Radio Communications › EPIRB
Issued 4 February 2003
Resolved
Replace broken EPIRB antenna as per 46 CFR 185.728.
Electrical › Electrical Distribution System (service)
Issued 9 December 2002
Resolved
Provide plans for electrical installation as required by 46 CFR 700 (b) for modifications and repairs. LEGACY COMPONENT DESC: all
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 9 December 2002
Resolved
Provide plans and details regarding installation of preengineered fixed fire system as per 46 CFR 181.400/420 LEGACY COMPONENT DESC: all
Engineering › Sea-water System (primary cooling)
Issued 9 December 2002
Resolved
Provide plans for exhaust system installation on both main engines. as required by 46 CFR 700(b) LEGACY COMPONENT DESC: all
Lifesaving › Buoyant Apparatus
Issued 7 March 2002
Resolved
REPAIR 22 MAN LIFEFLOAT AS REQUIRED BY 46 CFR 180.100. VESSEL NOT TO CARRY MORE THAN 22 PERSONS UNTIL LIFEFLOAT IS REPAIRED. LEGACY COMPONENT DESC: LIFEFLOAT
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 March 2002
Resolved
REMOVE CORROSION FROM BATTERY TERMINALS LOCATED ON STBD SIDE OF ENGINE ROOM AS REQUIRED BY 46 CFR 183.200.
Construction/Loadline › Hull
Issued 15 February 2002
Resolved
Repair blistering on hull where marked by CG inspector. Repairs to be made using original fiberglass lay up schedule.
Construction/Loadline
Issued 20 February 2001
Resolved
MAKE PORT GENERATOR HATCH VAPOR TIGHT AS REQUIRED BY 46 CFR 182.470_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Lifesaving
Issued 20 February 2001
Resolved
RENEW LIFE JACKET RETRO REFLECTIVE TAPE AND LIGHTS AS REQUIRED BY 46 CFR 182.670._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Navigation
Issued 20 February 2001
Resolved
PROVIDE BELL AS REQUIRED BY 72 COLREGS._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Lifesaving
Issued 20 February 2001
Resolved
REPAIR FORWARD SMOKE DETECTOR IN ACCOMODATION SPACE AS REQUIRED BY 46 CFR 176.810. _x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Electrical
Issued 11 January 2000
Resolved
PROVIDE AND INSTALL A PROPER STRAIN RELIEF CLAMP ON THE GENERATOR MAIN CABLE PRIOR TO CARRYING PASSENGERS. 46 CFR 183.10-20.
Accommodation/Occupational Safety
Issued 11 January 2000
Resolved
REMOVE EXCESS HOSE FROM MSD DISCHARGE LINE. 46 CFR 176.804.
Lifesaving
Issued 15 April 1999
Resolved
PROPERLY MARK EPIRB WITH THE VESSELS NAME AS PER 46 CFR 185.604(c).
Electrical
Issued 15 April 1999
Resolved
PROPERLY WIRE VESSEL AS PER 46 CFR 183.220.
Fire Fighting
Issued 15 April 1999
Resolved
PROVIDE AND INSTALL FIXED FIRE SYSTEM THAT MEETS THE REQUIREMENTS OF 46 CFR181.400 / 420.
Construction/Loadline
Issued 15 April 1999
Resolved
REMOVE OILY WASTE FROM ENGINE ROOM BILGES.
Accommodation/Occupational Safety
Issued 15 April 1999
Resolved
PROVIDE VENTILATION CLOING DEVICES FOR ENGINE ROOM VENTS AS PER 46 CFR 182.465(h)
Accommodation/Occupational Safety
Issued 15 April 1999
Resolved
REPAIR LADDER AND HAND RAIL LEADING TO THE WHEEL HOUSE.
Electrical
Issued 10 November 1998
Resolved
PROPERLY FASTEN WIRES HANGING FROM OVERHEAD IN ENGINE ROOM 46 CFR 183.340(b)(4).
Engineering
Issued 10 November 1998
Resolved
PROPERLY REPAIR EMERGENCY FUEL VALVE ACCESS COVER SO THAT IT CAN BE OPENED EASILY. 46 CFR 185.30-20.
Engineering
Issued 10 November 1998
Resolved
PROPERLY REPAIR ALL LEAKING FUEL FITTINGS THROUGH OUT THE VESSEL AS PER 46 CFR 176.804.
Accommodation/Occupational Safety
Issued 10 November 1998
Resolved
REMOVE WASTE OIL FROM BILGES IN ENGINE ROOM.46 CFR 176.804
Accommodation/Occupational Safety
Issued 10 November 1998
Resolved
RENEW VENT LINE FOR THE MSD TANK. 33 CFR 159.95.
Navigation
Issued 10 November 1998
Resolved
PROPERLY REPAIR HYDRAULIC LEAK ON STEERING PUMP UNDER CONSOLE IN WHEEL HOUSE. 46 CFR 176.800.
Lifesaving
Issued 15 May 1996
Resolved
PROVIDE AND INSTALL PLACARD STATING MAXIMUM PASSENGERS ALLOWED ON SECOND DECK IAW IFR 46 CFR 185.602(g).
Lifesaving
Issued 15 May 1996
Resolved
COMPLETE REPAIRS IAW MANIFACTURES STANDARDS TO SPLITS IN COVERS OF BOTH LIFEFLOATS. REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Electrical
Issued 15 May 1996
Resolved
REMOVE IMPROPER BARE LIVE WELL WIRING IN ENGINE ROOM OR INSTALL PROPER WIRING CONNECTION IN A JUNCTION BOX.
Lifesaving
Issued 15 May 1996
Resolved
PROVIDE AND POST PROPER LIFEJACKET DONNING PLACARD IAW 46 CFR 185.516.
Lifesaving
Issued 7 February 1996
Resolved
COMPLETE REPAIRS AS DISCUSSED FOR -1-OF THE -22- PERSON LIFEFLOATS. REPAIRSTO BE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 7 February 1996
Resolved
REMOVE EXCESSIVE ANGLE HAIR BUILD UP IN MACHINERY SPACES AND TREAT HULL THROUGHOUT VESSEL.
Accommodation/Occupational Safety
Issued 24 April 1995
Resolved
INSTALL LOCKING DEVICE ON MSD OVERBOARD SWITCH.
Lifesaving
Issued 24 April 1995
Resolved
PERMANENTLY ATTACH BOTH WATER LIGHTS TO RESPECTIVE LIFE FLOATS WITH BUOYANTLINES.
Construction/Loadline
Issued 24 April 1995
Resolved
STOP EXCESSIVE LEAKAGE AROUND PORT AND STARBOARD THROUGH HULL SHAFT LOGS.
Lifesaving
Issued 24 April 1995
Resolved
PERMANENTLY ATTACH WEAK LINK TO VESSEL.
Lifesaving
Issued 24 April 1995
Resolved
PERMANENTLY ATTACH SEA PAINTER TO BOTH LIFE FLOATS.
Electrical
Issued 24 April 1995
Resolved
INSTALL METAL WIRE CLAMPS ON ALL OVERHEAD WIRE RUNS IN ENGINE ROOM AT INTERVALS OF 18".
Deck/Cargo
Issued 24 April 1995
Resolved
INSTALL HOSE CLAMP ON POTABLE WATER TANK VENT.
Lifesaving
Issued 24 April 1995
Resolved
RENEW INOPERABLE WATER LIGHT ON LIFE FLOAT.
Engineering
Issued 3 May 1994
Resolved
INSTALL DIESEL FUEL SHUTOFF VALVES AT PORT AND STARBOARD MAIN DIESEL ENGINEAND THE DIESEL GENERATOR SET IAW 46 CFR 182.20-40(3). THIS INSTALLATION TOBE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Navigation
Issued 20 May 1991
Resolved
PROVE PROPER OPERATION OF FWD MAST HEAD AND STERN LIGHT.
Documentation
Issued 20 May 1991
Resolved
PROVIDE AND POST EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.25
Fire Fighting
Issued 20 May 1991
Resolved
PROVIDE AND INSTALL (4) MARINE FIRE EXTINGUISHER BRACKETS.
Electrical
Issued 20 May 1991
Resolved
PROVE PROPER OPERATION OF AMP METER.
Engineering
Issued 20 May 1991
Resolved
REPAIR AND INSTALL HANDLE REACH ROD ON STBD EMERGENCY FUEL SHUTOFF.
Navigation
Issued 20 May 1991
Resolved
REPAIR OR REPLACE PIN RAM CONNECTION TO TIE ROD RUDDERS
Electrical
Issued 20 May 1991
Resolved
MAKE PROPER CONNECTION BETWEEN EXHAUST HOSE GENERATOR
Engineering
Issued 20 May 1991
Resolved
BOND FUEL FILL CONNECTION TO TANK
Lifesaving
Issued 20 May 1991
Resolved
RENEW LINE TO RING BOUY (60') AND 18 FEET TO WATER LIGHT.
Lifesaving
Issued 20 May 1991
Resolved
REPAIR OR REPLACE ONE (22) PERSON LIFEFLOAT.
Engineering
Issued 20 May 1991
Resolved
PROVIDE AND INSTALL FUEL TANK VENT WITH 30 X 30 MESH WIRE SCREEN_x001C_ NON-CORROSIVE MATERIAL.
Lifesaving
Issued 20 May 1991
Resolved
PROVIDE ONE ADULT LIFEPRESERVER
Navigation
Issued 20 May 1991
Resolved
REMOVE TINTED WINDOWS ON FOUR SIDES AND REPLACE WITH CLEAR WINDOWS.
Engineering
Issued 20 May 1991
Resolved
PROVIDE DOCUMENTATION THAT SHOWS FUEL HOSE IS APPROVED TYPE FOR MAIN ENGINES AND GENERATOR.
Electrical
Issued 30 May 1990
Resolved
REPLACE OR REPAIR BATTERY BOX FOR PORT MAIN ENGINE.
Accommodation/Occupational Safety
Issued 30 May 1990
Resolved
CLEAN A/C CONDENSOR DRAIN PAN.
Deck/Cargo
Issued 30 May 1990
Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Navigation
Issued 30 May 1990
Resolved
SUPPORT HYDRAULIC RAM FOR STEERING AND RENEW CONNECTOR ARM BOLTS.
Electrical
Issued 30 May 1990
Resolved
REROUTE FEEDER CABLE FOR GENERATOR AND INSTALL 80 AMP BREAKER TO DERATE GENERATOR.
Accommodation/Occupational Safety
Issued 30 May 1990
Resolved
CROP AND RENEW DECKING BETWEEN TWO HEADS.
Documentation
Issued 30 May 1990
Resolved
PROVIDE AND POST A VALID FCC SAFETY CERTIFICATE.
Documentation
Issued 30 May 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety
Issued 16 June 1989
Resolved
REPAIR HAND RAIL TO FLYING BRIDGE.
Construction/Loadline
Issued 16 June 1989
Resolved
REPAIR BROKEN PILOTHOUSE AND SALON DOOR WINDOWS.
Navigation
Issued 16 June 1989
Resolved
DEMONSTRATE OPERATION OF SINGLE SIDE BAND RADIO.
Electrical
Issued 16 June 1989
Resolved
REPLACE COVER TO PILOTHOUSE FUSE PANEL.
Engineering
Issued 16 June 1989
Resolved
RPOVIDE MACHINERY GUARD FOR GENERATOR BELT AND MAIN ENGINES.
Electrical
Issued 16 June 1989
Resolved
PROVIDE BATTERY BOX FOR GENERATOR BATTERY.
Accommodation/Occupational Safety
Issued 16 June 1989
Resolved
CLEAN OR REPLACE RELIEF VALVE ON HOT WATER HEATER.
Electrical
Issued 16 June 1989
Resolved
HARD WIRE THE ELECTRIC BILGE PUMPS.
Electrical
Issued 16 June 1989
Resolved
REPAIR DAMAGED DECK LIGHTS AFT.
Accommodation/Occupational Safety
Issued 16 June 1989
Resolved
PROVIDE A HARD VENT TO NEAR THE VESSELS BILGES.
Documentation
Issued 16 June 1989
Resolved
PROVIDE ON BOARD A CURRENT CERTIFICATE OF DOCUMENTATION.
Navigation
Issued 3 February 1987
Resolved
PROVIDE PROOF THAT FORWARD FACING (3 PANES) TINTED GLASS WINDOWS IN PILOT HOUSE TRANSMIT AT LEAST 80% OF AVAILABLE LIGHT OR REMOVE AND REPLACE WITH GLASS THAT DOES MEET THIS STANDARD.
Unknown
Issued 3 February 1987
Resolved
UNDERGO A STABILITY TEST.
Unknown
Issued 4 August 1986
Resolved
VESSEL NEEDS A SIMPLIFIED STABILITY TEST DUE TO OCEANS ROUTE.
Navigation
Issued 8 July 1986
Resolved
RENEW EPIRB BATTERY
Deck/Cargo
Issued 8 July 1986
Resolved
PROVIDE ONBOARD A STANDARD DANFORTH ANCHOR OF AT LEAST 75 POUNDS WEIGHT.
Lifesaving
Issued 8 July 1986
Resolved
REPLACE THREE (3) NON WORKING PFD LIGHTS.
Electrical
Issued 13 June 1985
Resolved
DERATE THE GENERATOR IAW 46CFR 183.10-S(F.5).
Lifesaving
Issued 13 June 1985
Resolved
PROVIDE ONBOARD A SSB RADIO & A 20 PERSON LIFE FLOAT WITH PROPER EQUIPMENT.VESSEL IS LIMITED TO COASTWISE SERVICE UNTIL THIS REQUIREMENT IS COMPLETED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.