JEWEL

JEWEL is a 1985 passenger vessel (inspected). The Coast Guard has recorded 97 inspections since 1985, most recently in January 2026, along with 255 deficiencies, 1 operational control and 4 casualty investigations between 2008 and 2017.

Records from 1985 to 2026. Most recent: inspection, 21 January 2026.

Built
1985
Last inspected
21 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3274
253472
Flag
UNITED STATES
367336720
Maury page id
psix-253472

Inspections, by type

…with no type recorded20
Years with a record 36 calendar years (1985–2026)
The 97 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.5 ft × 28.0 ft × 6.3 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFREEPORT SHIPBUILDING & MARINE · FREEPORT, FL, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3274MMSI 367336720 · active · compulsorily equipped · granted 10 February 2018, expires 9 February 2028
WCX2748MMSI 366793740 · expired · compulsorily equipped · granted 8 February 2007, cancelled 22 April 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 97

21 January 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299345
27 February 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8085246
4 December 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8042725
28 February 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7871294
30 May 2023 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700152
28 November 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7600358
21 November 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596312
6 May 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7191074
10 November 2020 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7135760
5 March 2020 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6920852
27 February 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6633096
27 November 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6587696
11 April 2018 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6389398
29 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6330238
19 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6290831
27 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6276645
11 September 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6264138
8 August 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6234709
8 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249240
8 May 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6141145
21 November 2016 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6044945
3 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6051410
8 March 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5829013
14 May 2012 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4343443
23 February 2011 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3951691
1 April 2009 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3444312
23 January 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3400167
30 August 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320790
1 April 2008 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3175103
29 February 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3156008
9 January 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3127222
11 January 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2856656
13 October 2005 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2513872
11 October 2005 COI Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2511606
6 January 2005 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2269971
3 November 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2233660
9 August 2004 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2160766
28 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1995294
8 December 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1999095
17 November 2003 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1955988
21 January 2003 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1732806
6 January 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1731293
5 November 2001 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1431123
12 February 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1366165
23 October 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406804
29 February 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815428
20 January 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 813876
17 November 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 810650
7 September 1999 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786369
28 August 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 10043
29 July 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468082
8 February 1999 Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1410021
11 August 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 796120
28 July 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129449
17 November 1997 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787563
27 June 1997 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115143
15 January 1997 Deficiency Check · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1093842
31 July 1996 Deficiency Check · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1086709
14 June 1996 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1363700
12 June 1996 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1374657
1 May 1996 Drydock Extension
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1192134
27 June 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1417811
20 June 1994 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1414311
22 June 1993 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1457106
3 October 1992 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 647745
14 September 1992 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 933425
16 June 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 933584
24 June 1991 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 932219
17 April 1991 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1218968
20 September 1990 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 931387
25 June 1990 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 930976
1 November 1989 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1018368
26 June 1989 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1208038
24 August 1988 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1345938
27 July 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1341866
28 June 1988 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1207792
24 August 1987 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1032008
13 July 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1016599
30 June 1987 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1327712
10 June 1987 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1334570
1 June 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1016749
28 May 1987 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1031628
21 May 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1322323
12 May 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1332059
4 May 1987 Excursion Permit
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1333211
13 April 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1002050
16 March 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1324539
12 March 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1322974
27 February 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1322700
24 February 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1002401
10 February 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1012440
10 October 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1007869
21 August 1986 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 987825
30 June 1986 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1307785
10 April 1986 Credit Drydock
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1307129
18 July 1985 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1300816
2 July 1985 Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983722

Deficiency record · 255

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 February 2025 Resolved
"An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail." Starboard engine shaft did not have a guard. Replace guard. 46 CFR 116.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 10 March 2025
Resolution: photo submitted with guard over shaft
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2025 Resolved
"Penetrations and openeings in watertight bulkheads must: have means to make them watertight." Open piping found in forward storage room penetrating through a watertight bulkhead. Make the penetration watertight. 46 CFR 171.114
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 10 March 2025
Resolution: Penetration has been capped off
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 February 2025 Resolved
"Bulkheads between various spaces must meet the requirements of Table 116.415(b)." On vessel's fire control plan, 02 forward spaces underneath the main deck used for stowage were labeled as tank space and a void space (Category 12), with a storeroom (Category 9) in between. The 02 non-storerooms cannot hold stowage. Remove stowage. 46 CFR 116.415(b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2025
Resolved 10 March 2025
Resolution: photos sent of store rooms cleared out
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 27 February 2025 Resolved
"A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b) or a kit with equivalent contents and instructions." Vessel's first aid kits were expired. Replace first aid kits. 46 CFR 121.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 10 March 2025
Resolution: photo sent of new first aid kit w/ date of 2025-05-31
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 February 2025 Resolved
"Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended." Hydraulic leak discovered on starboard side steering gear in the lazarette. Repair hydraulic leak. 46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2025
Resolved 10 March 2025
Resolution: Operator submitting receipt paying for rod polishing, replacement of seals, and assembly and testing by 3rd party company.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 February 2025 Resolved
"Galley (9) means a space containing appliances with cooking surfaces that may exceed 121 C (250 F), such as ovens, griddles, and deep fat fryers." Unused oven equipment was found in space that does not meet structural fire protection standards for a galley. Remove oven equipment. 46 CFR 114.400
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2025
Resolved 10 March 2025
Resolution: oven removed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 May 2024 Resolved
A power driven fire pump shall be installed on each mechanically propelled "L" vessel. Fire pump seal is beginning to leak. Make fire pump operate without leaks. 46CFR181.10-1(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 10 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 February 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Permanently repair holes identified w/in the deck located in the ventilation space. 46 CFR 177.10-5 (OLD T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2024
Resolution: Deck was renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 February 2024 Resolved
Any vessel of at least five net tons... must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel had on board an expired COD; obtain valid COD on board. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: Vessel obtained new COD and paid NOV to FINCEN.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2024 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not have any FCC license certificates; obtain FCC licenses. 47 CFR 80.13(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2024 Resolved
The Bridge-to-Bridge Act... apply to the following vessels:... Every power-driven vessel of 20 meters or over in length while navigating; Vessel had an expired Bridge-to-Bridge certificate; obtain certificate. 47 CFR 80.1001(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2024 Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. No Stability Letter on board at time of inspection; obtain Stability Letter. 46 170.120(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 February 2024 Resolved
...the owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector... Vessel did not have service records on board for firefighting equipment; obtain records. 46 CFR 115.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 February 2024 Resolved
The emergency lighting required... If a vessel is not equipped with a single source of power for emergency lighting, it must have individual battery powered lights which... Are automatically actuated upon loss of normal power. An emergency light located in the accommodation space on the port side did not actuate upon loss of power; properly repair. 46 CFR 120.432(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2024 Resolved
Each ring life buoy on a vessel must:... be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150; Approval series could not be read on 01 ring life buoy; reflective material also incredibly worn; ensure approval series is labeled and replace retroflection tape. 46 CFR 117.70(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 February 2024 Resolved
"...items... are in proper operating condition, and fit for the service for which they are intended..." No blanks were present in the electric panel located at the Bridge. Provide panel blanks. 46 176.25-15(a) (OLD T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2024 Resolved
"Your vessel must undergo an annual inspection..." Schedule and complete your inspection. 46 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2024
Resolution: Endorsed COI for annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 November 2022 Resolved
At every vessel inspection, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Broken windows near the FWD stbd bow present safety hazard to passengers and crew.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 14 December 2022
Resolution: Widows have been replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 November 2022 Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse. The indicator must show whether the door is open or closed. Watertight door indicating panel was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 14 December 2022
Resolution: The panel was repaired.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 November 2022 Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests:(1) For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by Chapter 4 of NFPA 10, ‘‘Portable Fire Extinguishers,’’ with the frequency specified by NFPA 10. 40:BC extinguisher required by Table 118.500(a) lacked proof of recent annual servicing. 46 CFR 115.810(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 14 December 2022
Resolution: The portable extinguisher has been serviced.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 November 2022 Resolved
On a vessel on which the number of passengers permitted on the upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on the upper decks must be indicated by a durable marking of numbers and letters at least one inch in height at the entranceway to each such deck. Vessel's stability letter limits passenger carriage on upper deck, but no markings are present. 46 CFR 185.30-3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 14 December 2022
Resolution: Complete
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 May 2021 Resolved
Vessel is required to document crew training and the following information shall be included - date of the training and general description . 46CFR122.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 2 June 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 May 2021 Resolved
Vessel is required to log or documents when they conducted abandon ship and man overboard drills. Each member of the crew shall participate in at least one abandon ship drill each month. 46CFR122.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 2 June 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 May 2021 Resolved
Vessel is required to conduct at least one fire drill each month and it shall be logged or otherwise documented. 46CFR122.524
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 2 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2020 Resolved
Starboard main propulsion engine was inoperable, starboard fuel shutoff valve did not close when actuated at the remote pull station. Fix main engine and adjust starboard valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 5 March 2020 Resolved
Escape hatches must be marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR". Escape hatches for soda room and engine room did not have topside markings. Mark hatches accordingly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 March 2020 Resolved
Fire extinguishers and mounting brackets did not have numbering labels. Label each mounting bracket and extinguisher with matching numbers to confirm correct location placement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2020 Resolved
Stability letter was not posted at the operating station of the vessel. Post stability letter at operating station of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 5 March 2020 Resolved
Forward and aft ladderwells to upper deck did not have maximum passengers allowed number marked. Mark both ladderwells with maximum passengers allowed number.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 March 2020 Resolved
Aft main deck firestation did not have a spanner wrench. Provide spanner wrench.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2020 Resolved
Ring life buoys did not have vessel's name legibly marked. Mark all ring lifebuoys.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2020 Resolved
Upper deck lifejacket stowage under pilothouse was not accurately marked. Update marking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 March 2020 Resolved
Port and starboard bridge-wing light covers were broken and lights were inoperable. Repair lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2020 Resolved
Starboard side engine room fluorescent light panel did not have a cover. Pilothouse electrical distribution panel on transverse bulkhead was missing dead covers. Outlet below operating station console was not secured to mount. Aft engineroom electrical distribution panel breaker #33 created a 5 amp fault ground current. Aft engineroom electrical distribution panel was not fully labeled. Install cover for starboard engineroom light panel. Install dead covers on pilothouse electrical panel. Securely mount console outlet. Rectify fault ground current and fully label electrical distribution panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 5 March 2020 Resolved
DSC for VHF radio on pilothouse was not connected to GPS unit. Connect GPS to VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2020
Resolved 22 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 27 February 2019 Resolved
vessel lost throttle controls at main operating station do to a loss of air from a broken copper tube
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: Copper tubing for air supply to throttles was replaced. Conducted seatrials to verify proper operations of throttle
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2019 Resolved
Vessel has glass fuel bowls. Glass fuel bowls requires flame impingemnt shield
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 1 March 2019
Resolution: Flame shield was installed
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 February 2019 Resolved
Glass light covers are missing metal cage in engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 1 March 2019
Resolution: Metal cage was installed on lights
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2019 Resolved
Batteries in engineroom have loose connections
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 1 March 2019
Resolution: Battery connection was tighten
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 February 2019 Resolved
Throughout enginerooms sections of insulations is missing
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 5 March 2020
Resolution: Cleared during 05MAR2020 inspection
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2019 Resolved
s/w breaker in engineroom is broken and cant be turned on and off
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 1 March 2019
Resolution: new breaker was installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 February 2019 Resolved
Aux gen has an exhaust leak
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 1 March 2019
Resolution: Flange and gasket was changed to fix exhaust leak
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2019 Resolved
Two WTD gasket form machinery space needs to be replaced
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 5 March 2020
Resolution: Cleared during 05MAR2020 inspection
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 February 2019 Resolved
vessel has fault current going to the hull from bar lights
Condition: Placed in Improper Service
Due 28 March 2019
Resolved 5 March 2020
Resolution: Cleared during 05MAR2020 inspection
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 April 2018 Resolved
Provide FCC Bridge to Bridge and Safety Radiotelephony certificates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2018
Resolution: Verified new FCC certificates.
Engineering › Bilge Water Management System › Strainer
Issued 11 April 2018 Resolved
Replace bilge suction strainer in water tank space with those of an open area of no less than 3x the area of the bilge pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 12 April 2018
Resolution: Confirmed the strainer on the bilge piping was replaced as required in the water tank space.
Engineering › Bilge Water Management System › Not Operational
Issued 11 April 2018 Resolved
Prove proper operation of bilge piping system in storage space and water tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2018
Resolution: Witnessed proper operation of bilge system in water tank space and storage space.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 April 2018 Resolved
Replace/fix inoperable emergency light in storage space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 12 April 2018
Resolution: Verified emergency light operates correctly in storage space.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 11 September 2017 Resolved
vessel is required to submitt repair proposal and make repairs to all equipment that was damaged by fire in engine room prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 October 2017
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 8 August 2017 Resolved
vessel is required to fix exhaust leak
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2017
Resolution: Attened vessel to conduct sea trials at full power and exhaust leak was repair. No smell of exhaust in the engine room.
Engineering › Fuel Oil Service System › Filter
Issued 8 August 2017 Resolved
clogged filter cause vessel to lose ssdg and mde
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2017
Resolution: Attended vessel to conduct sea trials at full power. Ship responded accordingly to all throttle commands. Cause of failure in narritve.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 21 November 2016 Resolved
Replace both tailshaft cutless bearings. 46CFR61.20-23
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Replaced both bearings.
Construction/Loadline › Hull › Side Shell
Issued 21 November 2016 Resolved
Submit proposal for approval and make repairs to both P&S generator exhaust through hull fittings.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Replaced both exhaust through fittings.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 November 2016 Resolved
Drop both rudders for a better inspection of rudder post bearings.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Replaced both rudder post bearings.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 November 2016 Resolved
Properly secure loose piping in Lazerette.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Secured pipe with a new bracket.
Documentation › Certificates/Documents › Stability Letter
Issued 14 May 2012 Resolved
Vessel has fixed ballast in lazarette to improve bow trim. Ballast is not authorized as per stability letter. Naval architect shall submit ballast plan for updated stability letter.
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 14 June 2012
Resolution: Received a revised stability letter # H21202965 issued by MSC, demonstrating fixed ballast on the vessel.
Fire Fighting › Fire Pumps › Arrangement
Issued 14 May 2012 Resolved
Install gauge at fire pump indicating pressure.
Action required: 705 - Other - as specified
Due 21 May 2012
Resolved 1 June 2012
Resolution: Inspected to the satisfaction of attending CG marine inspector.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 14 May 2012 Resolved
Tighten shaft packing on both port and starboard shafts.
Action required: 705 - Other - as specified
Due 21 May 2012
Resolved 14 May 2012
Resolution: Inspected to the satisfaction of attending CG marine inspector.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 14 May 2012 Resolved
Attach rudder angle indicator transducer rod into starboard rudder post.
Action required: 705 - Other - as specified
Due 21 May 2012
Resolved 1 June 2012
Resolution: Inspected to the satisfaction of attending CG marine inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 14 May 2012 Resolved
Must provide updated charts for operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2012
Resolved 14 May 2012
Resolution: Inspected to the satisfaction of attending CG marine inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 May 2012 Resolved
Install brackets and remove red plastic cover in way of starboard ladder fire extinguisher.
Due 21 May 2012
Resolved 21 May 2012
Resolution: Received photos from operator demonstrating the above item has be corrected.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 14 May 2012 Resolved
Install exhaust cover in way of stove.
Action required: 705 - Other - as specified
Due 21 May 2012
Resolved 14 May 2012
Resolution: Inspected to satisfaction of attending CG marine inspector.
Fire Fighting › Grease Extraction Hood › General
Issued 14 May 2012 Resolved
Replace ceiling tiles where galley hood was removed.
Action required: 705 - Other - as specified
Due 21 May 2012
Resolved 14 May 2012
Resolution: Inspected to the satisfaction of attending CG marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2007 Resolved
C/R inset port side lazarette (stern) area above main deck.
Action required: 705 - Other - as specified
Resolved 1 February 2007
Resolution: Inset repaired.
Engineering › Bilge Water Management System › Strainer
Issued 11 January 2007 Resolved
Replace wasted bilge strainer on engine room.
Action required: 705 - Other - as specified
Resolved 1 February 2007
Resolution: Bilge strainer replaced.
Construction/Loadline › Structures › Deck Plating
Issued 11 January 2007 Resolved
Repair hatch coaming for lazarette to ensure proper sealing of hatch cover.
Action required: 705 - Other - as specified
Resolved 20 March 2007
Resolution: Hatch coaming repaired.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 January 2007 Resolved
Remove paint/flammables stowed around ice machine on upper deck.
Action required: 705 - Other - as specified
Resolved 1 February 2007
Resolution: Flammables removed.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 January 2007 Resolved
Repair hole in buoyant apparatus as discussed.
Action required: 705 - Other - as specified
Resolved 1 February 2007
Resolution: Buoyant apparatus repaired.
Documentation › Certificates/Documents › FCC SSL
Issued 13 October 2005 Resolved
Provide FCC Safety of Radio Certificate.
Condition: Unknown
Due 25 October 2005
Resolved 25 October 2005
Resolution: Provided.
Documentation › Certificates/Documents › FCC SSL
Issued 13 October 2005 Resolved
Provide FCC Marine Radio Operator Permit.
Condition: Unknown
Due 25 October 2005
Resolved 25 October 2005
Resolution: Provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 October 2005 Resolved
Provide updated drug testing paperwork.
Condition: Unknown
Due 25 October 2005
Resolved 25 October 2005
Resolution: Provided.
Lifesaving › Lifefloat › Paddle
Issued 13 October 2005 Resolved
Label lifefloat padels with vessel name.
Condition: Unknown
Due 25 October 2005
Resolved 25 October 2005
Resolution: Labelled.
Lifesaving › Lifefloat › Serviceable
Issued 13 October 2005 Resolved
Remove non-serviceable lifefloat.
Condition: Unknown
Due 25 October 2005
Resolved 25 October 2005
Resolution: Removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 13 October 2005 Resolved
Repair hydraulic leak on S/S MDE.
Condition: Unknown
Due 25 October 2005
Resolved 25 October 2005
Resolution: Repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 October 2005 Resolved
Investigate exhaust leak in engine room and make proper repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 November 2005
Resolution: Entire exhaust system replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 October 2005 Resolved
Provide FCC Safety of Radio Certificate.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 11 October 2005 Resolved
Provide updated drug testing paperwork.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Lifesaving › Lifefloat › Paddle
Issued 11 October 2005 Resolved
Label lifefloat paddles with vessel name.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Lifesaving › Lifefloat › Serviceable
Issued 11 October 2005 Resolved
Remove non-serviceable lifefloat.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 11 October 2005 Resolved
Repair hydraulic leak on Stbd side MDE in way of hydraulic oil gear pump.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 October 2005 Resolved
Provide FCC marine radio operator permit.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 October 2005 Resolved
Investigate exhaust leak in engine room and make proper repairs.
Due 25 October 2005
Resolved 13 October 2005
Resolution: Transferred to def check activity #2513872.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 3 November 2004 Resolved
Sea Rails Missing.
Condition: Unknown
Due 17 November 2004
Resolved 17 November 2004
Resolution: Re-attached sea rails on galley stove.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 3 November 2004 Resolved
Cracked Covering/Skin on all BA's & LF's.
Condition: Improper/Lack of Maintenance
Due 17 November 2004
Resolved 17 November 2004
Resolution: Repaired cracked covering/skin on all BA''s & LF''s IAW manufacture specs.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 November 2004 Resolved
Replace/Repair MDE Exhaust Lagging on P/S MDE Muffler Exhausts.
Condition: Improper/Lack of Maintenance
Due 17 November 2004
Resolved 17 November 2004
Resolution: Lagging repaired on P/S MDE muffler exhausts as proper.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 3 November 2004 Resolved
Tighten Shaft Packings on Stbd. MDE Shaft. (Leaking Profusely)
Condition: Improper/Lack of Maintenance
Due 17 November 2004
Resolved 17 November 2004
Resolution: Shaft packings tightened & operationally tested, leak halted.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 November 2004 Resolved
Present Valid COD. (Last expired on 31Oct2004)
Condition: Unknown
Due 17 November 2004
Resolved 17 November 2004
Resolution: Provided current COD.
Stability › Watertight Integrity
Issued 8 December 2003 Resolved
Make propper repairs to leak on port shaft log.
Due 8 January 2004
Resolved 4 March 2004
Stability › Watertight Integrity
Issued 8 December 2003 Resolved
Make propper repairs to leak on stbd. shaft log.
Due 8 January 2004
Resolved 24 February 2004
Fire Fighting › Combustible Materials
Issued 3 December 2003 Resolved
Install insulation to overhead in e/r. LEGACY COMPONENT DESC: Insulation
Due 8 January 2004
Resolved 24 February 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 3 December 2003 Resolved
Install lagging to port generator exhaust.
Due 8 January 2004
Resolved 24 February 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 3 December 2003 Resolved
Install lagging to stbd. generator exhaust.
Due 8 January 2004
Resolved 24 February 2004
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 3 December 2003 Resolved
Install lagging to port main eng. exhaust. LEGACY COMPONENT DESC: Piping (exhaust)
Due 8 January 2004
Resolved 4 March 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 December 2003 Resolved
Make propper repairs to oil leak on stbd. main eng. gear box.
Due 8 January 2004
Resolved 24 February 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 3 December 2003 Resolved
Install belt guard on port generator. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 8 January 2004
Resolved 24 February 2004
Documentation › Certificates/Documents
Issued 17 November 2003 Resolved
Post COI for Passengers to view.
Due 17 December 2003
Resolved 8 December 2003
Resolution: Posted COI for passengers to view on aft bulkhead of maindeck.
Navigation › Piloting/Steering
Issued 17 November 2003 Resolved
Provide proof of current tidal current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 17 December 2003
Resolved 24 February 2004
Communications › Radio Communications
Issued 17 November 2003 Resolved
Provide proof of new battery for EPIRB. Vessel is restricted to 3 mi AND 172 total persons, until NY03 is cleared by a USCG marine inspector. Vessel may carry 343 total persons on board, when on a rivers route only. LEGACY COMPONENT DESC: EPIRB
Due 17 December 2003
Resolved 24 February 2004
Lifesaving › Buoyant Apparatus
Issued 17 November 2003 Resolved
Properly stow survival craft as discussed. (Move oars, splice painter, repair painter release).
Due 17 December 2003
Resolved 24 February 2004
Resolution: Vsl replaced oars, repaired painter releases, and stowed craft properly.
Electrical › Electric Supply System (service)
Issued 17 November 2003 Resolved
Clean portside battery - remove oil from container.
Due 17 December 2003
Resolved 8 December 2003
Resolution: Removed oil from battery.
Engineering › Feedwater/Condensate Water System
Issued 17 November 2003 Resolved
Remove water from deck of tank room. LEGACY COMPONENT DESC: Tank
Due 17 December 2003
Resolved 8 December 2003
Resolution: Removed water from tank room deck. Determined cause of water to be garden hose draining on deck.
Operations/Management › Drills/Instruction
Issued 17 November 2003 Resolved
Conduct satisfactory fire and man overboard drill. LEGACY COMPONENT DESC: Fire
Due 17 December 2003
Resolved 8 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 November 2003 Resolved
Install belt guard on stbd. generator. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 8 January 2004
Resolved 24 February 2004
Fire Fighting › Combustible Materials
Issued 11 February 2003 Resolved
Remove paint in liquor space or provide metalic fire locker. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Unknown
Due 11 February 2003
Resolved 19 March 2003
Operations/Management › Navigation Safety
Issued 6 January 2003 Resolved
Provide updated navigation publications (USCG Light Lists, US Coast Pilots, Tides/Current Tables, and Rules of the Road) LEGACY COMPONENT DESC: Carriage of Charts and Publications
Due 25 January 2003
Resolved 11 February 2003
Documentation › Certificates/Documents
Issued 6 January 2003 Resolved
Provide FCC Safety Certificate LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Due 25 January 2003
Resolved 19 March 2003
Documentation › Safety/Response Plans/Programs
Issued 6 January 2003 Resolved
Provide and post fire control plan IAW 46CFR116.530. LEGACY COMPONENT DESC: Fire Control Plans
Due 25 January 2003
Resolved 19 March 2003
Documentation › Safety/Response Plans/Programs
Issued 6 January 2003 Resolved
Provide and post emergency evacuation plan IAW 46CFR116.520.
Due 25 January 2003
Resolved 19 March 2003
Engineering › Generator (propulsion-electric)
Issued 6 January 2003 Resolved
Repair fuel injector leak on port generator.
Due 25 January 2003
Resolved 19 March 2003
Engineering
Issued 6 January 2003 Resolved
Mount flame impingement bowl on starboard main engine.
Due 25 January 2003
Resolved 11 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 January 2003 Resolved
Install machinery guards on belts of air compressor, generators, and main engines. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 25 January 2003
Resolved 11 February 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 6 January 2003 Resolved
Permanently mount microwave in galley space.
Due 25 January 2003
Resolved 11 February 2003
Accommodation/Occupational Safety
Issued 6 January 2003 Resolved
Clean liquor storage area.
Due 25 January 2003
Resolved 19 March 2003
Fire Fighting › Fire Hydrants
Issued 6 January 2003 Resolved
Provide a spanner at fire station in main deck accomodation space.
Due 25 January 2003
Resolved 11 February 2003
Construction/Loadline › Structures
Issued 6 January 2003 Resolved
C/R deck plating to good metal at lazarette frame #1, Bay #2 (wasted plating). May be completed at next drydock. LEGACY COMPONENT DESC: Deck Plating
Due 25 January 2003
Resolved 11 February 2003
Documentation
Issued 5 November 2001 Resolved
Provide waste management plan which complies with 33CFR151.57(c)(1) through(c)(3).
Condition: Unknown
Due 12 November 2001
Resolved 16 November 2001
Lifesaving
Issued 5 November 2001 Resolved
Renew EPIRB hydrostatic release. Vessel restricted to no more than 3 miles from coastline until corrected.
Condition: Unknown
Due 5 November 2001
Resolved 16 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
Install captive device for lazarette hatch cover.
Condition: Unknown
Due 12 November 2001
Resolved 16 November 2001
Lifesaving
Issued 5 November 2001 Resolved
Install 1 waterlight to buoyant apparatus.
Condition: Unknown
Due 12 November 2001
Resolved 16 November 2001
Navigation
Issued 5 November 2001 Resolved
Permanently repair hydraulic leak to stbd steering ram.
Condition: Unknown
Due 5 December 2001
Resolved 16 November 2001
Unknown
Issued 5 November 2001 Resolved
Clean lazarette of all hydraulic fluid due to steering ram leak.
Condition: Unknown
Due 5 December 2001
Resolved 16 November 2001
Accommodation/Occupational Safety
Issued 5 November 2001 Resolved
Remove unapproved air compressor from vessel (portable wheeled unit stampedneither ASME U or UM).
Condition: Unknown
Due 12 November 2001
Resolved 16 November 2001
Lifesaving
Issued 5 November 2001 Resolved
Remove heat tape from air horn piping in overhead of wheelhouse.
Condition: Unknown
Due 12 November 2001
Resolved 16 November 2001
Electrical
Issued 5 November 2001 Resolved
Make electrical outlet on 2nd deck, stbd watertight (cover missing).
Condition: Unknown
Due 8 November 2001
Resolved 8 November 2001
Navigation
Issued 5 November 2001 Resolved
Prove proper operation of vessel's radar.
Condition: Unknown
Due 12 November 2001
Resolved 16 November 2001
Fire Fighting
Issued 12 February 2001 Resolved
Secure CO2 bottles in pantry space.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Construction/Loadline
Issued 12 February 2001 Resolved
V/W crack in starboard side lazzerate at deck line and stern
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Engineering
Issued 23 October 2000 Resolved
Replace expanded metal grid over shafts in engine room.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Electrical
Issued 23 October 2000 Resolved
Replace over voltage limitation light bulbs in spot fixtures on main deck approximately 40.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Navigation
Issued 23 October 2000 Resolved
Provide 12" bell in accordance with NAV Rules.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Fire Fighting
Issued 23 October 2000 Resolved
Replace unapproved smooth bore fire nozzles with approved combination fire nozzles.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Construction/Loadline
Issued 23 October 2000 Resolved
Make repairs to lazerette high water alarm.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Documentation
Issued 23 October 2000 Resolved
Add EPIRB TO FCC Station License & Safety Certificate.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Electrical
Issued 23 October 2000 Resolved
Make permanent repairs to switch board in engine room to remove opening around switches and breaker bar and knock-outs.
Condition: Unknown
Due 10 February 2001
Resolved 10 February 2001
Accommodation/Occupational Safety
Issued 23 October 2000 Resolved
Provide storm rails for stove
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Electrical
Issued 23 October 2000 Resolved
Prove proper operation of watertight door indication switches and light indicators on bridge.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Electrical
Issued 23 October 2000 Resolved
Provide Electrical matting in engine room.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Electrical
Issued 23 October 2000 Resolved
Make repairs to light fixtures in tank room.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Construction/Loadline
Issued 23 October 2000 Resolved
Make repairs to quick acting watertight door to freezer space / storage room.
Condition: Unknown
Due 5 January 2001
Resolved 5 January 2001
Construction/Loadline
Issued 29 July 1999 Resolved
Make repairs to engine room/main deck wtd, gasket has no contact w/door andthe door is not water tight.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Electrical
Issued 29 July 1999 Resolved
Make repairs to electrical short located in between service box and batterycharger in engine room.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Remove all spray in foam associated with penetrations and wire runs._x001C_ Polyeurethane foam is prohibited on subchapter K vessels.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999 Resolved
Provide 3 additional red flares and 3 additional smoke distress signals.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999 Resolved
Renew hydrostatic release for EPIRB.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Provide strainer for engine room bilge suction.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Provide valves at hull or connect stand (weld) pipe to provide level higherthan the deepest load water line before there are any flexible hose connections in accordance with 46 CFR 119.422.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999 Resolved
Make repairs to EPIRB. Strobe light is inoperable and inspector/operator isunable to verify proper operation.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Renew stuffing tubes and non-watertight penetrations for multiple wire runsthrough collision bulkhead, forward void, engine room, and lazerette bulkheads.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Provide bilge suction for area forward of collision bulkhead.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Electrical
Issued 29 July 1999 Resolved
Remove welding equipment and 220/208 supply.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 8 February 1999 Resolved
CROP AND RENEW 1" BALL VALVE ON AFT ENGINE ROOM SEA CHEST AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Accommodation/Occupational Safety
Issued 8 February 1999 Resolved
VERTICAL WELD BOTTOM STEP TO TRANSOM ACCESS BELOW WATER LIKE (U-BAR).
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Engineering
Issued 8 February 1999 Resolved
SUBMIT PLAN PROPOSAL FOR REPAIRS OF PORT STERN TUBE CRACK, TO NY OCMI.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Engineering
Issued 8 February 1999 Resolved
REPAIR CRACKED BLADE ON PORT PROP AND MAKE AVAILABLE TO MARINE INSPECTOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Construction/Loadline
Issued 8 February 1999 Resolved
CROP AND CAP OFF 1/2" BALL VALVE ON AFT ENGINE ROOM SEA CHEST.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Engineering
Issued 11 August 1998 Resolved
Provide proof of proper repairs to stbd tachometer and gauges. Fax ltr attesting to permanent repairs.
Condition: Unknown
Due 14 August 1998
Resolved 14 August 1998
Electrical
Issued 28 July 1998 Resolved
Repair loose light fixture to tank space entry.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Lifesaving
Issued 28 July 1998 Resolved
Tank space general housekeeping - stow loose gear.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Navigation
Issued 28 July 1998 Resolved
Prove proper operation of compass light.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Electrical
Issued 28 July 1998 Resolved
Correct openings in electrical boxes and missing covers throughout vessel. Top deck stbd, pilot house console, engine room center stanchion, etc.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Electrical
Issued 28 July 1998 Resolved
Remove dead ended wiring from pilot house console, tank space, etc.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Engineering
Issued 28 July 1998 Resolved
Attach broken port generator pipe hanger.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Fire Fighting
Issued 28 July 1998 Resolved
Swap fire extinguishers - B-I in pilot house and B-II at base of accommodation stairs.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Fire Fighting
Issued 28 July 1998 Resolved
Post sign for fire extinguisher located in accommodation closet.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Unknown
Issued 28 July 1998 Resolved
Conduct u/w emergency drills in presence of attending CG Marine Inspector.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
Plug open drain line which is leaking water into tank room.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
Stencil max persons allowed on top deck at all accesses.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Electrical
Issued 28 July 1998 Resolved
Remove wire ties on cables and renew with suitable metal hangers in tank room access to engineroom.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Engineering
Issued 28 July 1998 Resolved
Outline emergency fuel cut off valve label in red and paint handle to be more visible.
Condition: Unknown
Due 11 August 1998
Resolved 14 August 1998
Lifesaving
Issued 27 June 1997 Resolved
REPLACE CATEGORY C WITH CATEGORY I 406MHZ EPIRB.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 27 June 1997 Resolved
LABEL PANEL BOARD IN PILOT HOUSE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Accommodation/Occupational Safety
Issued 27 June 1997 Resolved
LABEL EMERGENCY ESCAPE EXITS OUTSIDE ENGINE ROOM
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 27 June 1997 Resolved
PROVIDE GLASS AND COVER GUARDS FOR LIGHTS IN THE ENGINE ROOM.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 27 June 1997 Resolved
CLEAN UP LOOSE WIRING IN ENGINE ROOM.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 27 June 1997 Resolved
REPLACE BULBS ON PORT NAV LIGHT AND ANCHOR LIGHT.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 27 June 1997 Resolved
REPLACE PADDLES ON LIFE FLOATS.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 27 June 1997 Resolved
GET ADDITIONAL BA'S TO ACCOMODATE 7 MORE PEOPLE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 27 June 1997 Resolved
GET PLASTIC MAT TO PLACE IN FRONT OF MAIN ELECTRICAL PANEL.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Engineering
Issued 15 January 1997 Resolved
REPLACE/RENEW BOTH P/S STRUT BEARINGS.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 15 January 1997 Resolved
INSTALL BILGE STRAINERS AT THE PICKUPS IN THE FOLLOWING SPACES: (A) HOLDINGTANK SPACE AND (B) THE SCULLERY.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 15 January 1997 Resolved
REPLACE/RENEW SEA VALVES INSTALLED AT SEA CHEST AND/OR INSTALL PLUGS TO PIPING THAT WILL NOT BE USED.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 15 January 1997 Resolved
GOUGE/REWELD THE CUTOUT TO THE POTABLE WATER TANK SPACE BOTTOM PLATING ON THE PORT SIDE.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 15 January 1997 Resolved
REWELD THE DAMAGED/CRACKED WELD AT THE PORT AFT CORNER.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Construction/Loadline
Issued 15 January 1997 Resolved
INSTALL A PIPE CAP ON THE NIPPLE PENETRATION OF THE AFT ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Navigation
Issued 15 January 1997 Resolved
RENEW THE PORT RUDDER POST BEARING.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 31 July 1996 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 August 1996
Resolved 21 October 1996
Electrical
Issued 31 July 1996 Resolved
MAKE OPERATIONAL THE WATERTIGHT DOORS REMOTE ELECTRICAL WARNING LIGHTS ON THE BRIDGE.
Condition: Unknown
Due 14 August 1996
Resolved 21 October 1996
Unknown
Issued 31 July 1996 Resolved
PROVIDE PROOF OF ENROLLMENT OF ENTIRE CREW IN AN APPROVED RANDOM DRUG TEST PROGRAM.
Condition: Unknown
Due 14 August 1996
Resolved 21 October 1996
Navigation
Issued 31 July 1996 Resolved
PROVIDE A COMPASS DEVIATION CARD ON THE BRIDGE.
Condition: Unknown
Due 14 August 1996
Resolved 21 October 1996
Engineering
Issued 31 July 1996 Resolved
INSTALL A FLAME IMPINGEMENT BOWL UNDER THE PORT MAIN ENGINE FUEL FILTER.
Condition: Unknown
Due 14 August 1996
Resolved 21 October 1996
Lifesaving
Issued 14 June 1996 Resolved
Prior to carrying passengers, but not later than the compliance date, properly mount all buoyant apparatus, including lines, line cages, proper weak-links & waterlights.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Navigation
Issued 14 June 1996 Resolved
Prior to carrying passengers, but not later than compliance date, provide navigation charts, publications and regulations as required by cognizant OCMI.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Navigation
Issued 14 June 1996 Resolved
Install pinkeepers on two largest rudder arm connecting pins, and properly lubricate all steering system mechanical joints._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Lifesaving
Issued 14 June 1996 Resolved
Prior to carring passengers, but not later than compliance date, perform underway life saving & fire drills to the satisfaction of the congnizant OCMI.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Engineering
Issued 14 June 1996 Resolved
Prove proper operation of port main diesel engine RPM guage located in pilot house.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
Properly mount and weather-proof pilot house and steel cover over upperdeckbar.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Electrical
Issued 14 June 1996 Resolved
Make proper electrical connections to all circuitry in pilot house.
Condition: Unknown
Due 14 June 1996
Resolved 14 June 1996
Electrical
Issued 27 June 1995 Resolved
Remove portable extension cords and properly install fixed wiring for cooler and freezer units in galley stores.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 27 June 1995 Resolved
Renew damaged wiring and make operable stbd side overhead light fixture in engine room.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 27 June 1995 Resolved
Properly mount soda pump/motor and install fixed wiring.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 27 June 1995 Resolved
Renew reflexive tape and deteriorated grab lines on all Buoyant appratus.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Accommodation/Occupational Safety
Issued 27 June 1995 Resolved
Mark main deck women's toilet.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Construction/Loadline
Issued 27 June 1995 Resolved
Properly adjust and prove operation of all three watertight doors.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Electrical
Issued 27 June 1995 Resolved
Repair and prove satisfactory operation of stbd service generator.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Accommodation/Occupational Safety
Issued 27 June 1995 Resolved
Make operable forward upper deck women's commode.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 27 June 1995 Resolved
Replace port generator housing covers.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 27 June 1995 Resolved
Locate and repair all generator and main deisel engine exhaust leaks in engine room.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Construction/Loadline
Issued 27 June 1995 Resolved
Repair hole at aft port corner (deck level) in way of after steering compt.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 27 June 1995 Resolved
Replace missing light switch cover in engine room passageway.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Fire Fighting
Issued 27 June 1995 Resolved
Replace upper deck fire hose with lined U.L. Standard 19 type.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Navigation
Issued 27 June 1995 Resolved
Provide valid fcc radio station license.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Navigation
Issued 27 June 1995 Resolved
Provide valid magnetic compass deviation card.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 27 June 1995 Resolved
Secure or remove upright refrigerator in galley stores.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Engineering
Issued 22 June 1993 Resolved
Remove portable air compressor, portable battery charger and fuel cans fromvessel.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Construction/Loadline
Issued 22 June 1993 Resolved
replace missing switch for engine room water tight door alarm.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Unknown
Issued 22 June 1993 Resolved
Clean fuel oil fill/vent containment.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Clean engine room ventillation supply blower.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Make installed air compressor pressure vessel availible for internal exaination, and demonstrate proper operation of the relief valve. RECINDEDITEM._x001C_ _x001C_
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Lifesaving
Issued 22 June 1993 Resolved
Provide six hand red flares with current expiration dates.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Tighten main engine mount bolts._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Clean all engine starting battery connections and replace cell caps where missing.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Electrical
Issued 22 June 1993 Resolved
Lable all circuit breakers in engine room.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Reinstall belt guards on starboard main engine.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Repair exhaust leak in starboard main engine exhaust muffler.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Electrical
Issued 22 June 1993 Resolved
Replace lighting fixture globes and guards where missing.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Accommodation/Occupational Safety
Issued 22 June 1993 Resolved
Make sanitary water to all heads functional.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993 Resolved
Renew pollution placard.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 22 June 1993 Resolved
Repair cracks and gouges in all eight life floats.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 22 June 1993 Resolved
Renew (white) painter and life lines on one life float.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Fire Fighting
Issued 22 June 1993 Resolved
Renew aluminum fire hose ends on main deck fire hose with brass ends.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Fire Fighting
Issued 25 June 1990 Resolved
PROVIDE 2 EACH USCG APPROVED FIRE NOZZELS.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Electrical
Issued 26 June 1989 Resolved
PLACE THE BATTERY UNDERNEATH THE BRIDGE CONSOLE IN A BATTERY BOX.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Electrical
Issued 26 June 1989 Resolved
REMOUNT ALL LOOSE WIRING UNDERNEATH THE BRIDGE CONSOLE.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Construction/Loadline
Issued 26 June 1989 Resolved
PROVIDE AND POST A DIAGRAM OF THE BILGE PIPING SYSTEM TO ALLOW IDENTIFI- CATION OF LETTERS ON VALVES.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Engineering
Issued 26 June 1989 Resolved
INSTALL INSULATION ON EXHAUST PIPING FROM PORT MAIN DIESEL ENGINE AND STARBOARD GENERATOR.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Electrical
Issued 26 June 1989 Resolved
REMOVE DEAD END WIRES FROM CABLE ATTACHED TO NO. 1 GENERATOR BATTERY.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Documentation
Issued 26 June 1989 Resolved
POST A POLLUTION PLACARD NEAR CONTROLS OF BILGE PUMP STATION.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Fire Fighting
Issued 26 June 1989 Resolved
REPLACE BROKEN PRESSURE GAUGE ON FIRE MAIN SYSTEM.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Electrical
Issued 26 June 1989 Resolved
INSTALL PROTECTIVE GUARD ON EMERGENCY LIGHTING FIXTURE POSITIONED OVER PUMP STATION IN ENGINE ROOM.
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Construction/Loadline
Issued 27 July 1988 Resolved
REPLACE FORWARD WATERTIGHT DOOR NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 27 July 1988
Resolved 27 July 1988
Electrical
Issued 28 June 1988 Resolved
REPAIR EXHAUST LEAKS ON PORT AND STARBOARD GENERATORS.
Condition: Unknown
Due 28 June 1988
Resolved 28 June 1988
Engineering
Issued 28 June 1988 Resolved
PROVIDE TAGS FOR BILGE MANIFOLD OR DIAGRAN FOR SYSTEM.
Condition: Unknown
Due 28 June 1988
Resolved 28 June 1988
Construction/Loadline
Issued 28 June 1988 Resolved
REPLACE DOG FOR STEERING GEAR COMPARTMENT COVER.
Condition: Unknown
Due 28 June 1988
Resolved 28 June 1988
Construction/Loadline
Issued 30 June 1987 Resolved
INSTALL AND PROVE OPERATION OF WATERTIGHT DOOR INDICATOR LIGHTS ON 2 FORWARD AND 1 AFTER WATERTIGHT DOORS BELOW THE MAIN DECK NOT LATER THAN 30 JULY 1987 TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Deck/Cargo
Issued 30 June 1987 Resolved
FREE CABLE AND PROVE OPERATION OF REMOTE FUEL OIL EMERGENCY SHUT OFF VALVE NOT LATER THAN 7 JULY 1987 TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Accommodation/Occupational Safety
Issued 10 June 1987 Resolved
REMOVE ALL VESSEL STORES FROM VOID SPACE BETWEEN FUEL TANKS UNTIL A-60 INSULATION IS INSTALLED ON OVERHEAD.
Condition: Unknown
Due 10 June 1987
Resolved 10 June 1987
Accommodation/Occupational Safety
Issued 27 February 1987 Resolved
THE HOT WATER HEATER UNDER PILOT HOUSE MUST BE SUITABLE FOR MARINE USE AND INSTALLED WITH FIXED PIPING, RELIEF VALVE AND ELECTRICAL CONNECTION OF A PERMANENT MATERIAL. WELD UP HOLES DRILLED IN WATERTIGHT BULKHEAD FRAME 17.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Electrical
Issued 27 February 1987 Resolved
PROVIDE VERTICAL AND HORIZONTAL SUPPORT FOR ALL ELECTRICAL CABLE WHICH COMPLY WITH IEEE45.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Construction/Loadline
Issued 27 February 1987 Resolved
STOP ALL WORK ON WATERTIGHT DOOR AT FRAMES 17 AND 11. SUBMIT DETAIL DRAWINGS ON THESE MODIFICATIONS TO INCLUDE FIT-UP AND WELDING PROCEDURES.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Accommodation/Occupational Safety
Issued 27 February 1987 Resolved
PROVIDE DETAIL DRAWINGS AND BILL OF MATERIALS ON MODIFICATIONS AND ADDITIONS TO THE AIR CONDITIONING SYSTEM.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Electrical
Issued 27 February 1987 Resolved
REMOVE ALL TWIST LUG TYPE ELECTRICAL CONNECTORS AND PROVIDE EITHER A CRIMP LUG, CRIMP SPLICE OR SOLDERED CONNECTION.
Condition: Unknown
Due 27 February 1987
Resolved 27 February 1987
Documentation
Issued 30 June 1986 Resolved
PROVIDE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 30 June 1986 Resolved
SPLICE LINES BETWEEN ALL FOUR LIFE FLOATS.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 30 June 1986 Resolved
RENEW EPIRB BATTERIES.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Documentation
Issued 30 June 1986 Resolved
PROVIDE VESSEL'S DOCUMENT.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986

Casualty record · 4

30 August 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3320790
3 September 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6051410
8 August 2017Routine · role: Involved in a Marine Casualty · activity 6249240
27 September 2017Routine · role: Involved in a Marine Casualty · activity 6276645
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.