Records from 2016 to 2025. Most recent: inspection, 16 April 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2025
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. Vessel did not complete annual drydock examination and internal structural examination as required on Certificate of Inspection. Vessel must complete new drydock examination and internal structural examination prior to carriage of passengers.
46 CFR 176.600 (c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 May 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. O/O has commenced a drydock inspection on 16APR2025 with the US COAST GUARD. Worklist was issued and shall be completed with credit drydock given by USCG prior to commercial operations (carriage of passengers).
46 CFR 176.600 (c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2025
Resolution: cleared and re-issued to complete new credit drydock / ISE due to vessel not completing drydock / ise.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2025
No resolution recorded
Empty anchor windlass battery housing of all water and replace battery housing cover in forepeak compartment.
Prior to credit drydock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2025
No resolution recorded
Renew frame head bolt on the port side, second frame from the stem, in forepeak compartment.
Prior to credit drydock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2025
No resolution recorded
Replace missing hardware on 01 deck STBD stanchion
(3rd from aft).
Prior to credit drydock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2025
Resolved
Replace deck light housing on stbd main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2025
Resolved 9 May 2025
Resolution: Replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2025
No resolution recorded
Repair cracked bench on the port side main deck.
Prior to credit drydock.
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 April 2025
No resolution recorded
Conduct chalk/hose test of water tight hatches in presence of MI's.
Prior to credit drydock.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 April 2025
No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel is outside of its inspection window and Certificate of Inspection is no longer valid.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 April 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Annual servicing of portable extinguishers was not completed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 June 2024
Resolution: O/O sent in servicing report
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 April 2024
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB registration was expired.
46CFR180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2024
Resolution: O/O obtained new NOAA registration.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 April 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Lifeline was deteriorated.
46CFR180.70(c)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2024
Resolution: Line was replaced
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 May 2023
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Vessels EPIRB hydrostatic release unit was found expired during inspection.
46 CFR 185.740(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 15 August 2023
Resolution: Recieved photos of new Hydrostatic Release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets were stored with adult life jackets and storage location and quantity of child life jackets was not properly marked.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 15 August 2023
Resolution: Recieved photo of life jacket stowage and markings.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 August 2021
Resolved
Each EPIRB battery replaced before expiration date required by FCC regulations and EPIRB test required to be logged; EPIRB Battery expired; limited route within 3NM until replaced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: New EPIRB installed; battery inspected satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2021
Resolved
Each survival craft must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway; life float questionable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Demonstrated safe use of life float prior to cold weather operations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2021
Resolved
Each life float must be outfitted with a lifeline, pendants two paddles, and a light; water light inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Verified water light operational
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2021
Resolved
Each vessel that operates more than 3NM from shore must have on board a FCC Category 1 EPIRB installed to automatically float free and activate; housing wasted; route reduced within 3NM from shore until standard met.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Verified installation of EPIRB.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 August 2021
Resolved
If number of passengers to upper deck is limited by stability criteria, must be indicated by a durable marking; no markings present
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 16 November 2021
Resolution: Vessel has posted a "no passengers allowed on upper deck" sign.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 August 2021
Resolved
Fuel shutoff valves must be marked in clear legible letters at least 1in high indicating the purpose of the valve and direction of operation; fuel off valve not labeled; label to meet standard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 16 November 2021
Resolution: Fuel shutoff valve has been properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 18 August 2021
Resolved
Crew space must be of adequate construction; soft spot on upper deck, port side
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Soft spot has been taken care of and will no longer present a safety hazard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 August 2021
Resolved
Items listed in standard missing from First Aid kit
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Verified all required first aid items present.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 August 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date US Coast Pilot or similar publication.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Verified up to date coast pilot kept onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2021
Resolved
Each child size life jacket must be stowed separately from adult jackets; jackets stored together
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2021
Resolved 9 November 2021
Resolution: Verified adult and child lifejackets are stored separately.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 August 2021
Resolved
Use of lights shall be complied with sunset to sunrise; stern light inoperable; bulb replaced.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 August 2021
Resolved 18 September 2021
Resolution: Light bulb replaced and demonstrated as operational on the spot.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 May 2021
Resolved
46CFR176.802: Fuel vent connection to the deck has wasted away, repair to satisfaction of [name withheld] item to CG-835.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 9 November 2021
Resolution: verified fuel vent connected to deck is appropriate.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 August 2020
Resolved
Vessel must be provided with High Water Alarm in each space. Forepeak High Water Alarm inop. Crew must conduct hourly rounds of the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 9 November 2021
Resolution: inspected and tested high water alarm in forepeak
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 August 2020
Resolved
Placard for donning and use of life jackets required. Multiple types of life jackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 9 November 2021
Resolution: verified presence of donning placard for each type of lifejacket onboard
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 August 2020
Resolved
Passenger count and crew limited to 41 people. Replace 2 adult life jackets and one child life jacket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 9 November 2021
Resolution: verified presence of appropriate number of life jackets to meet maximum of 25 persons on board to match COI
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 May 2019
Resolved
Found charts out of date, update charts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 29 May 2019
Resolution: Updated charts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2019
Resolved
Bilge discharge STBD #2 compartment leaking, replace hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 29 May 2019
Resolution: Replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 May 2018
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct portable and fixed fire extinguishing servicing. Portable and fixed fire extinguishing systems not serviced in over 12 months.
46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 21 May 2018
Resolution: Vessel owner provided servicing report froma qualified servicing facility for all portable and fixed fire extinguishing systems on board.
Construction/Loadline › Structures › Scuttle
Issued 17 May 2018
Resolved
Each hatch must have a way of securing. Forward hatch cover cannot be secured. 46 CFR 171.124(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 21 May 2018
Resolution: Vessel owner made repairs and inspectors witnessed the proper operation and securing of the forward hatch.
Documentation › Certificates/Documents › Stability Letter
Issued 17 May 2018
Resolved
Vessel must carry valid stability letter on board. Vessel does not have a valid stability letter on board.
46 CFR 170.120(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 21 May 2018
Resolution: Sector Hampton Roads Domestic Inspections provided the vessel owner with a copy of its valid stability letter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2018
Resolved
Wiring joints and splices must be mechanically secure. Wash down pump located in starboard aft engine room has broken wire connection. Fix wiring connection or remove wash down pump and secure through hull mechanically.
46 CFR 183.05-50(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 21 May 2018
Resolution: Vessel owner repaired wire connection to the wash down pump.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 May 2018
Resolved
Underway drills not conducted due to fire extinguishing equipment not be serviced.
46 CFR 176.810(d)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 21 May 2018
Resolution: Vessel conducted a man overboard recovey drill and fire drill to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Keel
Issued 25 July 2017
Resolved
Make permanent repairs to water leak at base of rudder post where temporaraily repaired. 46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Due 25 August 2017
Resolved 21 February 2018
Resolution: Verified permanent repair made to rudder post/horn timber.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 July 2017
Resolved
Mark location of Lifejacket stowage for proper amount.
Condition: Improper Installation
Due 31 July 2017
Resolved 25 July 2017
Resolution: Storage of lifejackets properly marked.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 July 2017
Resolved
Provide two adult lifejackets. Vessel passenger capacity reduced by two until corrected and verified.
Condition: Improper/Lack of Maintenance
Due 31 July 2017
Resolved 24 July 2017
Resolution: Corrected on the spot by replacing damaged lifejackets.
Construction/Loadline › Hull › Keel
Issued 24 July 2017
Resolved
Make proper repairs to secure water leak at base of rudder post. 46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 25 July 2017
Resolution: Temporary repairs were made. Deficiency issued to make permanent repairs.
Stability › Watertight Integrity › General
Issued 12 July 2016
Resolved
COMPLETE POST DRYDOCK WOOD BOAT SEA TRIAL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2016
Resolution: Completed post drydock wood boat sea trial.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2016
Resolved
Provide aspirin for first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Provided
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 April 2016
Resolved
Update or provide new coast pilot and light list.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Provided
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 April 2016
Resolved
Make repairs to stern light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Stern light operational.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 April 2016
Resolved
Connect VHF-DSC radio to GPS and input MMSI number.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Verified completed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 April 2016
Resolved
Renew raw water intake hose for M/E.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Verified damaged end of raw water hose was cut off.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 April 2016
Resolved
Make copy of FCC Safety Radio Certificate available.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: New FCC Safety Certificate provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 April 2016
Resolved
Prove proper operation of high level bilge alarm in E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Verified proper operation of bilge alarm in engine compartment.
Engineering › Bilge Water Management System › Pump
Issued 29 April 2016
Resolved
Prove proper operation of bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Verified operation of bilge pump in number 2 compartment.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 April 2016
Resolved
Renew flexible connection for stbd exhaust.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Verified flexible connection not leaking.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 April 2016
Resolved
Install manual pull and conduct maintenance of pull for fixed firefighting system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 17 May 2016
Resolution: Verified manual pull installed and secured.