Records from 2016 to 2026. Most recent: inspection, 21 April 2026.
Documentation record
Registered dimensions (L × B × D)27.5 ft × 12.1 ft × 4.6 ft
Registered tonnagegross 9 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA MARINE · MARATHON SHORES, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 18 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
21 April 2026
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8353627
14 February 2024
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7865319
18 May 2023
DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7693736
16 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7452056
4 January 2022
Drydock Exam · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7375295
26 April 2021
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7183278
28 February 2020
DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6917204
8 January 2020
Internal Structural Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6885461
20 June 2019
Deficiency Check · Administrative Inspection · DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6720146
14 January 2019
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6610137
11 June 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6535208
12 June 2017
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6303415
10 January 2017
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6106671
15 June 2016
Annual Inspection · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5907940
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 February 2024
No resolution recorded
Vessel failed to conduct drydock inspection within the required time frame. Must conduct a drydock inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 May 2022
Resolved
Both life float paddles were dry rotted and crumbleing appart. Must replace life float paddles that are at least 4 feet long.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2022
Resolved 18 May 2022
Resolution: 2 four foot paddles onboard.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 January 2022
Resolved
Re attach frames called out on both Port and STBD side under helm station
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2022
Resolution: Attached new brackets to secure frames
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 April 2021
Resolved
Fireboy system not functioning properly. Engine will shut down, but will not start in the override mode. Must conduct repairs and test to the satisfaction attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 3 May 2021
Resolution: Tech rep came out and replaced switch on helm station, Tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 April 2021
Resolved
Vessel only had 8 flares, must have 12. Replace missing flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 3 May 2021
Resolution: Vessel bought 4 more flares to meet the requirement of 12
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 April 2021
Resolved
Alcohol swabs were expired. Owner did show proof of new ones on order. Once arrive, show proof of valid Alcohol swaps.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2021
Resolved 3 May 2021
Resolution: Ordered new alcohol swabs with experation date of Aug 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 April 2021
Resolved
All around anchor light aft bulb was not working, must replace and test to the satisfaction of attending CG Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 3 May 2021
Resolution: Installed 2 new bulbs, test SAT
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 April 2021
Resolved
Vessel did not have a deckhand available for todays inspection. Must have deckhand available to get vessel underway and conduct fire and MOB drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2021
Resolved 3 May 2021
Resolution: Vessel underway to conduct MOB and Fire drills, SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2020
Resolved
2 adult life vest are wasted. Renew prior to carrying 24 person.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: 2 adult life vest were purchased and put into service.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 February 2020
Resolved
Hardware on steering mount is loose. Renew/Repair.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Hardware on steering mount was repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 February 2020
Resolved
Navigation light on starboard side is extinguished. Renew/Replace.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Starboard side navigation light was renewed and verified to be watching properly.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 February 2020
Resolved
Compass is required to be lighted. Renew/Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2020
Resolution: Compass light was renewed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 February 2020
Resolved
Remote fuel shut-off valve must be repaired/Renewed
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
Resolution: Remote fuel shut-off valve was repaired and verified to be in good working order.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 20 June 2019
Resolved
Engine room bilge auto operations light is extinguished. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2019
Resolution: Engine room auto operation bilge light has been repaired and is in good working order.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 June 2019
Resolved
VHF mush link to GPS or have its own GPS. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2019
Resolution: GPS is now reflected with the VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 June 2019
Resolved
Hand rail STBD side cabin top is loose. Renew/Repair hardware.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2019
Resolution: The hardware on the STBD side handrail was renewed, installed and allsat.
Lifesaving › Hand Flares › Quantity
Issued 12 June 2017
Resolved
Vessel is missing 3 orange smoke flares and 3 red hand flares. Provide
Action required: 705 - Other - as specified
Resolved 12 June 2017
Resolution: New flares were provided before exam was completed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 June 2017
Resolved
Fire extinguisher and pre-engineered system have not been serviced in over a year. Provide proof of service.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Third party servicing was conducted.
Engineering › Fuel Oil Service System › Valve
Issued 12 June 2017
Resolved
Fuel remote fuel shut-off valve is not marked.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Valve was properly marked.
Lifesaving › Lifefloat › Markings
Issued 12 June 2017
Resolved
Life float does not have the vessel name or capacity marked.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Life float was properly marked.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 June 2017
Resolved
Vessel does not have a portable light at the operating station.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Light was provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 12 June 2017
Resolved
Vessel does not have a log for monthly EPIRB testing and life saving equipment maintenance.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: New log books were created and placed into service.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 June 2017
Resolved
All navigation publications are expired. Provide new/update.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: New pubs were provided.
Engineering › Fuel Oil Service System › Filter
Issued 12 June 2017
Resolved
RACOR filter has broken hardware. Remount with new hardware.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017