MAURY USCG vessel records
← All vessels

MOONLIGHT

MOONLIGHT is a 1985 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 31 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 7 May 2026.

Built
1985
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WSH5085
253956
Flag
UNITED STATES
Maury page id
psix-253956

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)100.3 ft × 24.4 ft × 7.3 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMONTAUK PILOTS INC · GROTON, CT, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

7 May 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8368228
5 June 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8153065
9 July 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7946449
26 March 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7881072
24 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7695792
1 February 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7630607
2 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7454556
15 April 2022 Drydock Exam · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7430260
10 June 2021 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7220681
17 July 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007824
29 June 2020 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6990601
18 June 2019 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6841222
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526176
18 June 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6448916
26 April 2018 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6400131
5 June 2017 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6141611
17 June 2016 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5917777
19 April 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5857548

Deficiency record · 31

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2024 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Vessels fixed electric bilge pump could not dewater FWD peak. Vessel shall repair electric bilge pump. 46 CFR 182.25-1 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2024
Resolution: Vessel successfully pumped all bilges. This deficiency has been resolved.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 July 2024 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. PA system speakers on main deck did not operate. Vessel shall repair PA system on main deck. 46 CFR 184.610 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2024
Resolution: Vessel repaired PA system. This deficency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2024 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Vessel has no spacers in between life floats. Vessel shall install spacers between life floats 46 CFR 180.137 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Vessel has installed spacers between life floats. This defciecny has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve... MI's noted several seams failing on life floats. Vessel shall repair life floats IAW manufacturer instructions. 46 CFR 180.175 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Vessel has repaired life float IAW manufacturer instructions. This deficecny has been resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel has excess hazmat on board and gear adrift. Vessel shall remove excess hazmat and address gear adrift. 46 CFR 176.830 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Vessel has removed hazmat and addressed gear adrift. This deficency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2024 Resolved
Each life jacket stowed overhead must be supported in a manner that allows quick release for distribution. Overhead above life jacket stowage area is sagging and potentially impeding quick distribution of life jackets. Vessel shall repair overhead. 46 CFR 180.78 (a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Vessel has completed repairs to overhead IVO life jacket stowage. This defciency has been resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2024 Resolved
All vessels with overnight accommodations must be equipped with a general alarm system. The public address system required by § 184.610 of this chapter may be used to sound the general alarm signal. Vessel is equipped with overnight accommodations (racks). Vessel has stated that there is not an intention of utilizing. Vessel shall remove racks from vessel or get in compliance with overnight accommodation requirements. 46 CFR 183.550
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Vessel has removed racks from vessel. This deficecny has been resolved.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 July 2024 Resolved
...all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. Vessel does not have ladder for second means of escape in fwd space. Vessel provide repairs proposal and repair second means of escape. 46 CFR 177.15-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 August 2024
Resolution: Vessel fabricated and installed new ladder. this deficecny has been resolved.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2024 Resolved
certification, re inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Vessel has hot water heater plugged into receptacle. Vessel shall permanently wire hot water heater. 46 CFR 176.25-50 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 23 September 2024
Resolution: Vessel permanently wired hot water heater.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2024 Resolved
At each initial and subsequent inspection for certification, re inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Vessel exhaust system has several broken brackets. Vessel shall repair brackets. 46 CFR 176.25-50 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 August 2024
Resolution: Vessel repaired exhaust brackets. This deficecny has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2024 Resolved
..rescue boat shall be required except when, in the opinion of the OCMI the vessel is of such design and operating characteristics that the vessel itself provides a fully satisfactory rescue platform. Vessels rescue platform is not IAW SEC NY policy. Vessel shall get rescue platform in compliance. 46 CFR 180.10-35 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2024
Resolution: Vessel provided pictures of plaform added to resuce device. This defciency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2024 Resolved
..the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel performed MOB using sharp gafs to recover Oscar. Vessel determine a safer way to recover MOB.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2024
Resolution: Vessel has outfitted MOB with boat hooks. This deficecny has been resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 May 2023 Resolved
Steering space watertight hatch missing a way to keep attached to vessel. Provide way to secure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2023
Resolved 26 May 2023
Resolution: Line has been fixed to hull and hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2023 Resolved
Fuel line coming off Port Fuel tank heavily corroded. Replace fuel line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: Line has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 May 2023 Resolved
Grab lines on life floats that are detriorated beyond repiar. Replace grab lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: All grab lines have been replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 24 May 2023 Resolved
Railing that is sharp edge and rusting is a hazard. Provide solution to mitgate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: Padding has been added in the concerned areas.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 24 May 2023 Resolved
Coaming on upper deck stairwell needs to identify hazard to crew and passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: Area has been painted yellow to contrast the deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2022 Resolved
Grab lines on Ring Life Buoy shall be 3/8" with a minimum breaking strength of 1,350 lbs. Grab lines on STBD and AFT Ring Life Buoys are frayed. Replace grab lines on Ring Life Buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2022
Resolved 14 June 2022
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 June 2022 Resolved
Painter lines must be stowed in such a way that it runs out freely when life float floats away from sinking vessel. Painter lines not stowed to freely release. Conduct maintanence so painter line runs out freely.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2022
Resolved 14 June 2022
Resolution: installed properly
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 June 2022 Resolved
Each pendant on a life float must have a breaking strength of at least 540 lbs. Pendant visibly frayed on life floats. Replace frayed pendants.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2022
Resolved 14 June 2022
Resolution: replaced
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 April 2022 Resolved
Submit repair proposal to USCG for all plate (identified by gauging report dated 4/21) at or higher than 25% wastage.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2022
Resolved 19 May 2022
Resolution: completed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2020 Resolved
Remove extension cord and replace with a permanent electrical circuit in aft cabin used to supply portable fans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 23 July 2020
Resolution: New circuit installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018 Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 17 October 2018
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 June 2018 Resolved
Replace all batteries in float lights.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 1 August 2018
Resolution: Batteries replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 June 2018 Resolved
Replace float light on life float. Protective cover missing on light.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 1 August 2018
Resolution: Float light replaced.
Engineering › Thrusters › Hose
Issued 18 June 2018 Resolved
Repair hydralic leak in bow thruster void
Action required: 705 - Other - as specified
Due 18 July 2018
Resolved 1 August 2018
Resolution: Area cleaned. Leak could not be found.
Engineering › Compressed Air System (start air) › Control Gear
Issued 18 June 2018 Resolved
Bench test pressure releif valve on air compressor.
Action required: 705 - Other - as specified
Due 18 July 2018
Resolved 1 August 2018
Resolution: Pressure guage replaced and relief valve tested.
Engineering › Bilge Water Management System › Hose
Issued 18 June 2018 Resolved
Replace bilge hose attached to strainer in lazerate.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 18 June 2018
Resolution: Hose replaced.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2018 Resolved
Repair clutch on bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2018
Resolved 18 June 2018
Resolution: Pump repaired.
Engineering › Bilge Water Management System › Eductor
Issued 5 June 2017 Resolved
Repair the bilge piping in the forepeak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2017
Resolved 8 June 2017
Resolution: Piping repair.
Construction/Loadline › Hull › Bracket
Issued 5 June 2017 Resolved
Repair broken bracket on the port rudder tube.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 8 June 2017
Resolution: Bracket repaired.