Records from 2016 to 2020. Most recent: inspection, 28 December 2020.
Electrical › Electric Supply System (service) › Transformer
Issued 11 May 2017
No resolution recorded
Vessel contained inverter wired to battery bank that was designed for recreational vehicle use and not plan reviewed. Several saftey and fire hazards identified. Remove inverter and all associated installation wiring and submit for plan review. 46 CFR 176.700
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2017
Resolved
Operator hardwired 12V outlet to sewage circuit without plan review. Automotive style inverter was plugged into outlet that supplied power to ~20" monitor for passengers' viewing. Remove 12V adaptor & all associated wiring from sewage circuit and submit plan review. 46 CFR 176.600
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 16 June 2017
Resolution: Installation was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2017
Resolved
Operator installed 110 VAC cicuits (wiring/components/outlets) throughout vessel without plan approval. Outlets are connected in series with non-marine grade conductors that don't meet UL requirements and weren't installed IAW 46 CFR 183.340. Remove all 110VAC circuits & submit for plan approval. - 46 CFR 176.700
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017
Resolved 5 June 2017
Resolution: 110 Circuits were removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 May 2017
No resolution recorded
Center battery isolator switch is missing high-amperage control knob, which presents electrical shock hazard. Middle battery isolator switch must be installed with high-amperage control knob. - 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017 — due date passed with no resolution recorded
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 11 May 2017
No resolution recorded
Operator installed a venrilation system with ~5FT of ~3" PVC piping on STBD side in fwd compartment without plan review. Fan was spliced into an extension cord to a 110VAC outlet. Vent fan was mounted in fwd bulkhead of Engineroom preventing it from being vapor tight. Remove all unapproved vent piping/fans; seal holes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2017 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 May 2017
Resolved
Float light did not work due to inoperative battery. Operator changed battery and re-installed. 46 CFR 180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 11 May 2017
Resolution: Operator changed battery and re-installed IAW 46 CFR 180.175(f)(4).
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 July 2016
No resolution recorded
Remove all welding cables being used as battery cables and install UL Boat or UL Marine Cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2016 — due date passed with no resolution recorded
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 26 July 2016
Resolved
Provide current Navigational Rule book.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 18 October 2016
Resolution: Provided updated Navigational Rule book.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 July 2016
Resolved
Remove all used oils, trash, debris and unrelated to operations material from the vessel.
Accumulation deemed possible fire hazard and could prevent proper bilge dewatering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 18 October 2016
Resolution: Removed used oils, trash, debris, and unrrelated to operations material.
Engineering › Bilge Water Management System › Valve
Issued 26 July 2016
Resolved
Provide positive shutoff valves at the hull penetrations of each bilge discharge line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 1 December 2016
Resolution: Special consideration granted to not have a positive shutoff valve at hull penetration.
Engineering › Bilge Water Management System › Not Installed
Issued 26 July 2016
Resolved
Permanently mount STBD bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 18 October 2016
Resolution: STBD bilge high water alarm permanently mounted
Engineering › Bilge Water Management System › Pump
Issued 26 July 2016
No resolution recorded
Install submersible electric bilge pumps that meet UL 1113, 10 GPM.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2021 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 July 2016
Resolved
Renew all soaked sorbent pads throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 18 October 2016
Resolution: Replaced soaked sorbent pads with new pads.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 26 July 2016
Resolved
Provide adequate support to MDE exhaust pipping in the lazarette.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 18 October 2016
Resolution: Provided support to MDE exhaust piping
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 July 2016
Resolved
Replace expired eye wash, burn cream, aspirin, and ammonia inhalants.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 18 October 2016
Resolution: All expired first aid kits replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 July 2016
No resolution recorded
Plug all holes in the forward and aft engine room bulkheads, ensure it is vapor tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016 — due date passed with no resolution recorded