Records from 1985 to 2008. Most recent: inspection, 5 December 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
5 December 2008
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3374989
24 October 2006
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2806455
8 March 2006
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2599830
27 January 2006
Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2576110
10 August 2005
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2457087
20 August 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2171477
20 August 2003
Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1863915
29 July 2003
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1861041
14 August 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1661342
7 August 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1403451
10 August 2000
COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1365938
30 June 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088063
11 May 1999
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1129270
8 April 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1381534
1 April 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1406293
27 February 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1101119
28 May 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 58640
6 March 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1078764
1 February 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 837968
10 January 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1147390
21 July 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 843693
29 July 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 960589
29 July 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1264756
20 April 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 112946
31 July 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 934486
16 July 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 939311
2 August 1990
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1240533
5 October 1989
Plan Review "T" Boat
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1327103
10 August 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1345214
4 August 1989
Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 894348
10 January 1989
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1351608
10 February 1988
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1295966
15 July 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1016977
9 April 1986
Credit Drydock
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1306927
7 January 1986
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 988605
29 March 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1295348
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 10 August 2005
Resolved
Provide a high water alarm for the engine room compartment with a visual and audible indication at the operating station.
Due 20 September 2005
Resolved 22 September 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 August 2005
Resolved
Provide new eye wash for the first aid kit.
Due 20 September 2005
Resolved 22 September 2005
Documentation › Markings/Placards › Garbage Placard
Issued 10 August 2005
Resolved
Provide a new garbage placard for the vessel.
Due 20 September 2005
Resolved 22 September 2005
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 10 August 2005
Resolved
Provide 6 feet of anchor chain to the anchor with a shackle and anchor line.
Due 20 September 2005
Resolved 22 September 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 August 2005
Resolved
Provide 60 feet of dark buoyant line for the life ring.
Due 20 September 2005
Resolved 22 September 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 August 2005
Resolved
Fire servicing is will be due in Oct.2005. Provide servicing to all fire extinguishers to coincide with the vessel's COI anniversary date.
Due 20 September 2005
Resolved 22 September 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 10 August 2005
Resolved
Provide a station licence for the vhf radio.
Due 20 September 2005
Resolved 22 September 2005
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 August 2005
Resolved
Provide securing devices for all hatch covers.
Due 20 September 2005
Resolved 22 September 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 August 2005
Resolved
Repaint all name and number markings on the hull.
Due 22 October 2005
Resolved 30 September 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 10 August 2005
Resolved
Replace the stuffing box prop shaft bearing on both shafts.
Due 22 October 2005
Resolved 30 September 2005
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 10 August 2005
Resolved
Remove paint from all hull zincs.
Due 22 October 2005
Resolved 30 September 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 August 2002
Resolved
CONDUCT LIFESAVING AND FIREFIGHTING, TRAINING AND DRILLS.
Due 30 August 2002
Resolved 23 August 2002
Resolution: RECEIVED FAX OF TRAINING AND DRILLS.
Construction/Loadline
Issued 10 August 2000
Resolved
REPAIR ALL UNDERCUT WELDS NOTED BY CG APPROX. 60FT.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Documentation
Issued 8 April 1999
Resolved
PROVIDE PROOF THAT COMPANY EMPLOYEES MEET THE RANDOM DRUG TESTING PROGRAM REQUIREMENTS OF 46CFR 4, 5, & 6 ( EXAMPLE; ALL EMPLOYEES ARE IN SAME RANDOMPOOL.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Lifesaving
Issued 27 February 1997
Resolved
RENEW RING BUOY W/ REFLECTIVE TAPE
Condition: Unknown
Due 27 February 1998
Resolved 28 February 1997
Fire Fighting
Issued 27 February 1997
Resolved
REPLACE CRACKED HOSES ON CO2 FIRE EXTINGUSHERS
Condition: Unknown
Due 27 February 1997
Resolved 28 February 1997
Fire Fighting
Issued 27 February 1997
Resolved
PROVIDE ON BOARD 3 THREE 2-1/2 GAL FIRE BUCKETS.
Condition: Unknown
Due 27 February 1997
Resolved 28 February 1997
Documentation
Issued 21 July 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Lifesaving
Issued 16 July 1991
Resolved
PROVIDE FIVE ADULT PFD'S. LIMITED TO 34 PASSENGERS UNTIL COMPLETED
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Documentation
Issued 16 July 1991
Resolved
PROVIDE CURRENT COPY OF VESSEL DOCUMENTATION
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
LABEL CIRCUITS IN PANEL BOX IN PILOT HOUSE
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Lifesaving
Issued 2 August 1990
Resolved
PROVIDE THREE ADULT SIZE PFD'S
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Electrical
Issued 2 August 1990
Resolved
REMOVE ELECTRICAL TAPE FROM WIRING UNDER CONSOL.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Lifesaving
Issued 2 August 1990
Resolved
RENEW LINE ON RING BOUY WITH LINE THAT IS BOUYANT IN NATURE
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Electrical
Issued 4 August 1989
Resolved
PRIOR TO FINAL APPROVAL, PLAN 1035-0011, ELECTRICAL, SHALL BE MODIFIED AND THREE COPIES PROVIDED TO [name withheld] THE EMERGENCY DISCONNECT SWITCH FOR THE DIESEL ENGINE 12 VOLT SYSTEM.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Construction/Loadline
Issued 4 August 1989
Resolved
PROVE SATISFACTORY OPERATION OF ELECTRICAL BILGE PUMP TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION NOT LATER THAN 4SEP89.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Construction/Loadline
Issued 4 August 1989
Resolved
PROVE SATISFACTORY OPERATION OF HYDRAULIC BILGE PUMP PRIOR TO CARRYING ANY VEHICLES AND/OR PASSENGERS AND NOT LATER THAN 4SEP89 TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Engineering
Issued 4 August 1989
Resolved
PRIOR TO FINAL APPROVAL, PLAN 1035-006, HYDRAULIC PIPING, SHALL BE MODIFIEDAND THREE COPIES PRIVODED TO [name withheld] THE HYDRAULIC PIPING MODIFICATIONS AS BUILT AND APPROVED BY [name withheld] ON 4AUG889.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Electrical
Issued 10 February 1988
Resolved
ELIMINATE ELECTRICAL WIRING TO INOPERATIVE JABSCO PUMP TO HEATER.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Electrical
Issued 10 February 1988
Resolved
PROVIDE WOODEN BLOCKS TO 12 VOLT BATTERY TRAY.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Unknown
Issued 10 February 1988
Resolved
PROVIDE GLOBE TO LIGHT FIXTURE IN MACHINERY SPACE.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988
Construction/Loadline
Issued 15 July 1987
Resolved
PROVIDE PROPER RUBBER/SILCONE GASKETS FOR VEHICLE DECK.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Construction/Loadline
Issued 15 July 1987
Resolved
PROVIDE SECOND HORIZONTAL COURSE OF CHAIN ACCESS VEHICLE RUNWAY.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Construction/Loadline
Issued 15 July 1987
Resolved
ELIMINATE RUBBER HEATER HOSE USED AS BILGE PIPING. REPLACE WITH METALLIC PIPING AS INSTALLED THROUGHOUT VESSEL.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Fire Fighting
Issued 15 July 1987
Resolved
PROVIDE MEANS OF SECURING VENTILATION TO ENGINE ROOM IN EVENT OF DISCHARG- ING OF CO2 CYLINDER.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Electrical
Issued 15 July 1987
Resolved
PROPERLY SECURE ELECTRICAL WIRE IN MACHINERY SPACE AT LEAST EVERY 24 INCHES. ELIMINATE EXCESS WIRE AND DEAD CABLE.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Electrical
Issued 15 July 1987
Resolved
PROVIDE MISING GLOBES ON LIGHTS IN MACHINERY SPACE.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Fire Fighting
Issued 15 July 1987
Resolved
PLACE BLOCK UNDER CO2 CYCLINDER ON MAIN DECK TO PROVIDE 2 INCHES OF SPACE BETWEEN DECK AND CYLINDER.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987