MAURY USCG vessel records
← All vessels

CAPT. JP III

CAPT. JP III is a 1985 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in August 2025, along with 63 deficiencies, 2 operational controls and 1 casualty investigation in 2012.

Records from 2012 to 2025. Most recent: inspection, 26 August 2025.

Built
1985
Last inspected
26 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2012
254086
Flag
UNITED STATES
Maury page id
psix-254086

Documentation record

Registered dimensions (L × B × D)149.5 ft × 34.0 ft × 7.0 ft
Registered tonnagegross 99 / net 83
ITC dimensions (L × B × D)149.5 ft × 34.0 ft × 7.0 ft
ITC tonnagegross 781 / net 276
BuilderSERODINO INC · GUILD, TN, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFORT MYERS, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it781 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
276 - Convention (Subpart B), Net Ton
83 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

26 August 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8217894
4 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7995803
18 July 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7960989
18 May 2023 Deficiency Check · MTSA Verification · In-Service Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7691095
27 January 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7585262
19 July 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7515783
8 June 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7470061
31 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7301897
30 September 2020 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7070094
28 August 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6797339
26 August 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6794741
12 August 2019 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6780775
25 January 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6615294
25 January 2019 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6618671
27 September 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6559373
1 May 2018 Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6435168
5 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6385332
1 February 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384565
1 June 2017 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6162095
31 March 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5844256
19 January 2016 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5803548

Deficiency record · 63

09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 26 August 2025 Resolved
Where pressure-indicating gages are used, they must be chosen to be compatible with the pressure to be indicated. MIs observed a broken pressure gauge on the relief valve of the Air Compressor. Replace the pressure gauge with an appropriate sized gauge for the pressures to be observed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2025
Resolution: Vessel submitted photos showing the pressure gauge was replaced. See correspondence in documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel reported that they were missing 14 adult life jackets. Passenger count limited to 586.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2025
Resolution: Vessel sent email with invoice to show condemned life jackets were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2025 Resolved
A number of child-size life jackets equal to at least 10% of the number of persons permitted on board must be provided,
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2025
Resolution: Vessel sent email with invoice to show condemned life jackets were replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 September 2024 Resolved
CO2 Cylinders must be maintained in accordance with NFPA Standards. CO2 Cylinders Hydrostatic testing greater than 12 Years from Stamp. Hydrostatic test all CO2 Cylinders. 46 CFR 181.400 - 701 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2024
Resolution: Provided servicing reciept of CO2 cylinder's being hydrostatically tested.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 September 2024 Resolved
Fire Dampeners installed in engine room with fixed fire extinguishing systems must have dampeners installed. Engine room fire dampener missing. 46 CFR 181.20-35
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2024
Resolution: Reference pictures attached.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 4 September 2024 Resolved
Vessel is missing alcohol testing swabs. 46 CFR 122.212
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: Provided documentary evidence of new swabs on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2024 Resolved
Permanently wire or remove decorative LED lights from Pilot House to Aft Exhaust Stack. 46 CFR 120.410
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: Recieved documentary evidence via photos that lights were hardwired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2024 Resolved
Review Circuit boards and electrical pannels. De-energize breakers labelled as spares and update directory for pannel d in liquor locker on 2nd deck. 46CFR 120.330
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: photos attesting to completion of deficiency clearance.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 September 2024 Resolved
Railing for guard rail opening was secured with zip ties. Remove and install rigid closure pins. 46 CFR 115.830
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: Pictures added showing metal pins added to secure the guards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2024 Resolved
Renew life rings, life rings sealing plugs were missing. Compromising internal foam. 46 CFR 117.71
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: photos attesting to completion of deficiency clearance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2024 Resolved
02 hydralic lines in steering system need to be replaced. 46 CFR 115.814
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: photos attesting to completion of deficiency clearance.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 September 2024 Resolved
Structural fire protection in engine room damaged and worn. Replace. 46 CFR 116.405
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: photos attesting to completion of deficiency clearance.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 September 2024 Resolved
Emergency Lighting in engine room space not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 September 2024 Resolved
Several lights missing guards/ covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: See attached pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2024 Resolved
Replace wirenuts in stbd side battery compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2024
Resolution: see attached pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
All electrical installations shall be to the satisfaction of the OCMI. - Remove or cap all dead end wiring in generator and engine room - Main power distribution wiring located in engine room is not properly secured and beginning to corrode on shielding. Re secure and remove corrosion. - Shaft seal bilge pump wiring is twisted together as a spice. install single run of wire or environmentally seal splice. - HP Air cond chiller No1 and No2 circuit breakers call for 100A breakers, 125 are installed. Provided original drawings or electricians report attesting the breaker requirements and install new breaker as appropriate. - Install blanking plate on distribution panel in generator room. (under AC Comp (13)) - Lighting in lazerette does not function. - Dead end wire in way of stbd rudder post. Re-install wiring. 46CFR183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 May 2023 Resolved
Vessels that carry more then 150 passengers shall meet the requirements of subchapter H for structural fire protection. Reinstall SFP in both machinery spaces where it has been removed. Provide repair plan and materials list prior to installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 May 2023 Resolved
All escape hatches and other emergency exits shall be marked "Emergency Exit, Keep Clear." - Fwd escape hatch for generator space needs to be remarked, letters have been worn off. - Sign leading to fwd escape in generator space has broken off. Re-attached sign indicating route of escape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 May 2023 Resolved
Vessels that carry more then 150 passengers shall meet the requirements of subchapter H for structural fire protection. - Install fire stop in all wire penetrations through bulkheads. 46CFR177.10-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 May 2023 Resolved
All vessels shall be provided with no less then two avenues of escape. Top hinge on male bathroom door on 01 deck is broken. Door does not function properly and is an egress hazard. Repair door.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 August 2021 Resolved
A DEVICE MUST BE PROVIDED TO AUTOMATICALLY SHUT DOWN VENTILATION SERVING THE PROTECTED SPACE AND ENGINES THAT DRAW INTAKE AIR FROM THE PROTECTED PACE PRIOR TO RELEASE OF THE EXTINGUISHING AGENT INTO THE SPACES. MI DISCOVERED THAT THE STBD ENGINE SPACE'S VENTILATION DID NOT SHUT DOWN ONCE THE FIXED SYSTEM WAS TESTED. 46 CFR 118.410 (b)(10)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2021
Resolution: Operator had a technician come onboard after the inspection. The technician installed a lever connected to the vessel's emergency shutdown. Once activated, both blowers shut down ventilation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 August 2021 Resolved
COMBUSTIBLE INSTALLATION SHALL BE USED FOR PIPE AND MACHINERY COVERING OR LAGGING WITHIN A MACHINERY SPACE. MI DISCOVERED PORTIONS IN THE ENGINE ROOM SUCH AS ABOVE THE BOILER WERE MISSING REQUIRED PORTIONS OF INSULATION. 46 CFR 116.430(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 1 September 2021
Resolution: Operator sent photographs showing all newly placed/installed portions of installation above called out areas in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2021 Resolved
A VESSEL GREATER THAN 65 FEET IN LENGTH MUST CARRY A MINIMUM OF THREE LIFE BUOYSR. DISCOVERED THAT THE VESSEL CARRIED 02 LIFE BUOYS. 46 CFR 117.70(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 1 September 2021
Resolution: Operator sent a photograph of 03 life ring buoys onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 August 2021 Resolved
WITH PERMANENT TYPE CONNECTORS. SPRING CLIPS OR OTHER TEMPORARY TYPE CLAMPS ARE PROHIBITED. DISCOVERED THAT THE BATTERY CONNECTIONS WERE NOT PERMANENT TYPE CONNECTORS. 46 CFR 120.350(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 1 September 2021
Resolution: Operator sent photographs of permanent battery connectors. Opeator overhauled all temporary connectors.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 31 August 2021 Resolved
THE STORAGE CYLINDERS FOR A FIXED FIRE SYSTEM SHALL BE ACCESSIBLE FOR INSPECTION/TO ACCESS ITS CONTROLS IN CASE OF AN EMERGENCY. DISCOVERED THAT THE OPERATOR WAS UNABLE TO ACCESS ALL REQUIRED CONTROLS FOR THE FIXED SYSTEM. 46 CFR 118.410
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 1 September 2021
Resolution: Operator sent video/photograph of easily accessing the fixed fire system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019 Resolved
EACH LIFE JACKET CARRIED MUST BE MARKED IAW 46CFR122.604. SEVERAL LIFEJACKETS HAD THE VESSEL'S PREVIOUS NAME AND/OR FADED/DETERIORATED RETRO-REFLECTIVE TAPE. 46CFR117.71(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019 Resolved
T-L VESSELS SHALL BE FITTED WITH SUITABLE BILGE SUCTION STRAINERS W/NOT LESS THAN THREE TIME THE NOMINAL OPENING OF THE PIPE. THE ENGINE ROOM BILGE SUCTION STRAINER WAS WASTED TO FAILURE. 46CFR182.25-5(b) 'OLD T'
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Monitoring of voyage or passage plan
Issued 25 January 2019 Resolved
Prior to movement of the vessel from its current berth in Troy, NY, you are to notify the Command Center at US Coast Guard Sector NY at [phone withheld]. This requirement is in reference to the conducting Towing Operations under safe weather conditions on the Hudson River.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2019
Resolution: Vessel owner and Salver kept SECNY informed of details of the towing operation. Vessel was safely towed from Troy, NY to Nyack, NY and secured at the North River Shipyard, Nyack, NY.
Documentation › Certificates/Documents › FCC SSL
Issued 5 April 2018 Resolved
provide FCC station license - vessel is restricted to <1000ft from shore.
Action required: 705 - Other - as specified
Resolved 10 April 2018
Resolution: O/op provided electronic copy of FCC Station License.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 April 2018 Resolved
Program MMSI number into VHF radio
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 10 April 2018
Resolution: O/op provided electronic documentation of programmed MMSI number in VHF radio.
Documentation › Markings/Placards › Warning Signs
Issued 5 April 2018 Resolved
Post emergency broadcasting placard at operating station
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 10 April 2018
Resolution: O/op provided electronic documentation of posted emergency broadcast placard.
Documentation › Certificates/Documents › Permit, Other
Issued 5 April 2018 Resolved
prove complete proof on elevator inspection - prior to using elevator.
Action required: 705 - Other - as specified
Resolved 17 April 2018
Resolution: Vessel proved proper operation of elevator.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 April 2018 Resolved
clean bilges of oil and flammable material in generator space.
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Bilges were properly cleaned.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 5 April 2018 Resolved
secure armored cable to electrical panel in generator space
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Armored cable was properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2018 Resolved
remove or cap all dead-end wires in void space fwd of the generator space and also in the laz
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: All dead-end wires were properly removed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 April 2018 Resolved
prove proper operation of float light on ring buoy - restricted to daytime operations.
Action required: 705 - Other - as specified
Resolved 17 April 2018
Resolution: Confirmed operation of float light.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 April 2018 Resolved
provide 2018 light list and tide/current
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Confirmed new LL and tide/currents.
Documentation › Certificates/Documents › Permit, Other
Issued 5 April 2018 Resolved
prove written designation of senior deckhand and required engineer.
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed proper designation of senior deckhand and engineer.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 April 2018 Resolved
Provide record of completion of man overboard, fire, and security drills.
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 10 April 2018
Resolution: O/op provided electronic documentation of recorded drills.
Construction/Loadline › Hull › Weld
Issued 5 April 2018 Resolved
properly seal cut openings in port and stbd bulkhead in laz space to ensure watertight integrity
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed properly sealed openings in bulkhead.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2018 Resolved
provide repair proposal for corroded area in overhead on fwd stbd side of laz
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed proper repairs of corroded overhead in laz compartment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2018 Resolved
seal all wire runs in all spaces to ensure watertight integrity
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed sealed wire runs.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 5 April 2018 Resolved
vessel must prove proper operation of 480v ground detection
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed operation of ground detection on 480V.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 5 April 2018 Resolved
install ground fault meter for 208/120 circuit
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed properly operating and installed ground fault meter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2018 Resolved
enclose all wire connections in junction boxes
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed installation of required junction boxes.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 April 2018 Resolved
provide unexpired first aid kit
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 17 April 2018
Resolution: Witnessed required first aid kit.
Engineering › Bilge Water Management System › Pump
Issued 1 June 2017 Resolved
Prove proper operation of bilge pump, to include the pumping of all watertight spaces, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2018
Resolved 5 April 2018
Resolution: Verified the proper operation of all bilge pumps.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 June 2017 Resolved
Provide licensing for all crew operating vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2018
Resolved 5 April 2018
Resolution: Verified all MMCs for master/crew.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 June 2017 Resolved
Conduct Fire and Man Overboard drills prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2018
Resolved 5 April 2018
Resolution: Conducted satisfactory fire, man overboard, and security drills.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 June 2017 Resolved
Provide proof of DAPI enrollment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2018
Resolved 5 April 2018
Resolution: Verified proof of DAPI enrollment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 June 2017 Resolved
Provide a CG approved first aid kit.
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 5 April 2018
Resolution: Vessel's new first aid kit was expired since purchasing; requirement rewritten as 835 in Activity# 6385332.
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2017 Resolved
Provide updated charts, coast pilot, light list, and tides and currents tables for operating area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 5 April 2018
Resolution: Cleared chart/Coast Pilot from def; requirement for tides/currents and Light List rewritten as 835 in Activity# 6385332.
Construction/Loadline › Structures › Door
Issued 1 June 2017 Resolved
Repair 3rd deck emergency exit door.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2017
Resolution: Witnessed satisfactory operation.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2017 Resolved
Prove proper operation of navigation lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2017
Resolution: Witnessed satisfactory operation.
Documentation › Certificates/Documents › Permit, Other
Issued 1 June 2017 Resolved
Provide proof of elevator annual inspection. Prior to using elevator.
Action required: 705 - Other - as specified
Resolved 13 November 2017
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 1 June 2017 Resolved
Provide fire protection in overhead of the lazarette and space aft of bow thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2017
Resolved 13 November 2017
Engineering › Steam Boiler (auxiliary/waste heat) › Air Heater
Issued 1 June 2017 Resolved
Prove electric water heater meets part 53 and 63 in subchapter F.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2017
Resolved 5 April 2018
Resolution: Verified electric water heater met applicable subchapters.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 January 2016 Resolved
Properly blank off open space in Panel F - generator room.
Due 19 February 2016
Resolved 27 January 2016
Resolution: Spaces were properly blanked with commercial blanks.
Fire Fighting › Structural - Horizontal Zones › General
Issued 19 January 2016 Resolved
Insulation in generator room is falling in several areas.
Due 19 February 2016
Resolved 27 January 2016
Resolution: Insulation has been properly hung as required.
Engineering › Pressure Vessel › Safety Valve
Issued 19 January 2016 Resolved
The pressure/temp relief valve on the hot water heater is directed to an open space. Install diverter pipe to safe direction. Location - generator room
Due 19 February 2016
Resolved 27 January 2016
Resolution: A PVC diverter line has been permanently fitted to the P/V relief valve.
Engineering › Fuel Oil Service System › Piping
Issued 19 January 2016 Resolved
Fix leaking F/O pipe in the overhead of the generator room - port side.
Due 19 February 2016
Resolved 27 January 2016
Resolution: The coupling was tightened and is no longer showing signs of leakage.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 19 January 2016 Resolved
Prove proper operation of rescue boat/launching mechanism.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2016
Resolution: Resue boat was launched using the ships davit and the rescue boat was run for approx. 10 minutes with both fwd and reverse verified and a full range of speed witnessed.
Electrical › Electric Supply System (service) › Cable
Issued 19 January 2016 Resolved
Properly terminate dead end wire in generator space.
Due 19 February 2016
Resolved 27 January 2016
Resolution: Wire was terminated inside an existing junction box and secured appropriately.

Casualty record · 1

19 May 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4342969
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HENRIETTA III (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.