MAURY USCG vessel records
← All vessels

SEA LOVE III

SEA LOVE III is a 1985 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in July 2026, along with 62 deficiencies, 4 operational controls and 4 casualty investigations between 2014 and 2023.

Records from 2014 to 2026. Most recent: inspection, 5 July 2026.

Built
1985
Last inspected
5 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 July 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI6496
254183
Flag
UNITED STATES
Maury page id
psix-254183

Documentation record

Registered dimensions (L × B × D)42.1 ft × 14.5 ft × 6.1 ft
Registered tonnagegross 33 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA LOVE INC · PONCE INLET, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 7 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

5 July 2026 Vessel Attendance · Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8429142
31 March 2026 Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8338864
11 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8157450
20 May 2025 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8140086
21 April 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8116504
8 January 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8060215
25 November 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8039584
29 October 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8035477
21 August 2024 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7986038
5 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7872357
21 August 2023 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7773542
8 June 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7708163
7 June 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7721791
16 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7535476
24 June 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7485715
23 March 2022 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7404458
18 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7265201
14 April 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7175318
29 May 2020 COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6952432
7 May 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6949937
9 April 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6934277
26 August 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6791654
1 May 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6674048
1 May 2019 Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6674328
28 August 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6517804
17 April 2018 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6393039
15 August 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6241469
29 August 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5983972
26 April 2016 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5863183

Deficiency record · 62

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Make necessary repairs to the satisfaction of the attending Coast Guard MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2026
Resolution: Cleaned aftercoller, reinstalled and conducted power trial.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025 Resolved
Eash connection to a conductor or terminal part of a conductor must be made within an enclosure and have a pressure type connector on each conductor. Stern flood light found unwired with wires hanging down, replace wiring connections and conduct operational test. 46 cfr 183.340(g)1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 9 June 2025
Resolution: Corrected wiring
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 May 2025 Resolved
Abandon ship and MOB drill's shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel could not provide adequate log, records of drills, maintenance/testing. Create new boat log and ensure maintenance, testing of lifesaving equipment, and drills are properly logged. 46 cfr 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 9 June 2025
Resolution: Logs being recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2025 Resolved
A fire hose with a nozzle must be attached to each hydrant at all times. Nozzle was missing, replace nozzle. 46cfr181.320(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 9 June 2025
Resolution: nozzle was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 November 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements... Vessel lost propulsion while operating offshore. Vessel is restricted from carrying passengers until Coast Guard marine inspector attendance.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2024
Resolved 26 November 2024
Resolution: Observed two successive starts of engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2024 Resolved
No alterations that affect the safety of the vessel may be made without OCMI approval. Automatic reels and associated wiring were installed without apoproval.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2025
Resolution: Wiring removed.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 23 August 2024 Resolved
Vessel was not fitted with an Medium Frequency (MF) Radio. Per FCC regs, 47 Part 80.905(a)(2), vessels operating 20 to 100 miles on an oceans route required a MF Radio. 47 CFR 80.903 requires FCC Tech to inspect a SPV and issue a Safety Radiotelephony Certificate (form 824) once every five years. Vessel limited to 20 N miles from shore until FCC Safety Radio Cert/Form 824 issued.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2024
Resolved 21 April 2025
Resolution: FCC Form 824 provided. Deficiency satisfied and cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 August 2024 Resolved
EPIRB Battery expired. Obtain new battery or new EPIRB with proper registration. Until resolved IAW 46 CFR 180.64 & 185.728 vessel limited to 3 N miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 23 August 2024
Resolution: New EPIRB procured, confirmed EPIRB registered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2024 Resolved
Upon activation, fuel oil remote closing valve cable broke. Fix remote fuel oil shut off valve cable and demo proper operation IAW 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Cable replaced & def corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 August 2024 Resolved
When installed, unable to move steering system emergency tiller bar. Make repairs and demo operation iaw 46 CFR 182.620
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Reviewed hydraulic piping, no cross connect valve. O/O, Master, & CG MI agreed, if system system lost pressure tiller bar could be operated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2024 Resolved
Observed wire hanging near vessels stern light. Properly terminate wire as required by 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: E-mail with statement and photo provided by O/O reflecting deficiency corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 August 2024 Resolved
Steering gear hatch cover gasket worn. Renew steering gear hatch cover gasket iaw 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: E-mail with statement and photo provided by O/O reflecting deficiency corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2024 Resolved
Aft overhead light, portside above fishing deck box, hanging by electrical wire. Properly mount the light fixture iaw 46 CFR 183.410
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: E-mail with statement and photo provided by O/O reflecting deficiency corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2024 Resolved
Child life jacket stowage bag open, whereby mixed with the adult lifejackets. Separate Child life jackets from the adults iaw 46 CFR 180.78
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2024
Resolved 23 August 2024
Resolution: Observed Child Lifejackets stowed and separated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2024 Resolved
Crew unable to pump water thru the fixed bilge system. Make repairs and demo operation iaw (Old TS) 46 CFR 182.25-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Observed crew de-water forward & aft bilges thru the fixed bilge system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 August 2024 Resolved
Noted excessive oil & water observed in forward engine room bilge. Remove excessive oil & water as required by 46 CFR 176.830(b).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2024
Resolved 23 August 2024
Resolution: Observed oil & water removed from bilge.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 August 2024 Resolved
Master & Crew have no history of preforming MOB drill. Demonstrate recovery of a man over board and fire drill in presence of an attending CG MI iaw 46 CFR 176
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2024
Resolved 23 August 2024
Resolution: Observed crew preform a satisfactory MOB drill.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 August 2024 Resolved
Vessel not fitted with an official logbook. Place an official log book on the vessel and record; trips, crew, passenger count, EPIRB monthly testing, Lifesaving & Fire fighting inspections, and crew drills, iaw 46 CFR 185.504/.520/.702/.728
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 4 October 2024
Resolution: Viewed and confirmed vessel logbook.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 22 August 2024 Resolved
Missing FCC vessels Radio safety equipment inspections record. Authorized FCC inspector required to check radio installation & provide inspection cert/form 824 to CG MI iaw 47 CFR 80.13. 04OCT24 requirement extended, to be resolved by 23OCT2024.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2024
Resolved 4 November 2024
Resolution: Received copy of FCC Radio Cert
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 August 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2024
Resolved 12 November 2024
Resolution: Received an e-mail with statements and supporting documents reflecting company compliant with DAPI requirements per 46 CFR Part 16
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 March 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Add fire detector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 11 March 2024
Resolution: Vessel installed smoke detector in the main cabin area.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 August 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 12 February 2024
Resolution: Company rep provided e-mail, with statement and proof requirement satisfied.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 August 2023 Resolved
Observed three "orange" day light flares were expired. O/O to obtain three new CG approved day light flares as required by 46 CFR 180.68. Replacement flares shall be onboard the vessel prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2023
Resolved 25 August 2023
Resolution: Received an e-mail with statement & photos reflecting 6 new orange flares were procured and placed onboard the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 August 2023 Resolved
Observed several first aid kit items; aspirin, eye wash solution, ointment were expired. All expired items shall be renewed and the content of the first aid kit must comply with 46 CFR 160.041 as required by 46 CFR 184.710. Requirement to be rectified within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting new First Aid Kit items were placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2023 Resolved
Observed one life float painter was dry-rotten, port life float lantern lens was worn, and both water life float water lights to be non-serviceable. O/O shall renew life float painter, lantern, and water lights as required by 46 CFR 180.137. Requirement to be rectified within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting replacement of painter.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 23 August 2023 Resolved
Portable extinguishers and engine room fixed system last serviced August 2022. Serving scheduled for next week. As required by 46 CFR 176.810(7)(B), after servicing, provide copy of third party serving report to attending CG Marine Inspector. Requirement to be rectified within 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 29 August 2023
Resolution: Service reports provided, reviewed and requirement satisfied.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 August 2023 Resolved
Observed pilot house bilge alarm box fitted with audible alarm/horns and LED lights. Confirmed audible alarm, although all LED's broken and did not illuminate, as required by 46 CFR 182.530. O/O, to renew existing bilge alarm panel or renew all LED lights. Requirement to be rectified within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting replacement of LED lights on alarm box.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 23 August 2023 Resolved
Companies DOT alcohol test strips expired. Company to procure new DOT approved alcohol test strip as required by 46 CFR Part 16.240. Recommended a few alcohol test strips be placed onboard the vessel. Rectify deficiencies with in 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting procurement of new alcohol strips.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2023 Resolved
List reflecting employee's enrolled in random chemical testing program was not available. Company to provide 3rd party consortium list reflecting current employee's enrolled in the random chemical testing program as required by 46 CFR 16.230.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos of DAPI enrolled employees.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 August 2022 Resolved
A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”. Distress signals not properly marked.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 August 2022
Resolved 9 September 2022
Resolution: Signals properly Maked
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 August 2022 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q. Float light for life float inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 9 September 2022
Resolution: Waterlight replace
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2022 Resolved
If of the garden type, be of a good commercial grade constructed of an inner rubber tube, plies of braided fabric reinforcement, and an outer cover of rubber or equivalent material, and of sufficient strength to withstand the maximum pressure that can be produced by the fire pump. All fittings on the hose must be of suitable corrosion-resistant material. Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Fire hose found leaking and missing nozzle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 9 September 2022
Resolution: Fire hose replaced
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 August 2022 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency procedures typo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 9 September 2022
Resolution: Procedures updated
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 August 2021 Resolved
FIXED GAS FIRED EXTINGUISHING SYSTEMS, THE INSPECTIONS, AND TEST IAW TABLE 176.810(B) OF THIS PART IN ADDITION TO REQUIRED TESTING. THE PRE-ENGINEERED FIXED EXTINGUISHING SYSTEM WAS FOUND IN A RECHARGE STATUS ON GUAGE. SERVICING RECORDS COULD NOT BE PRODUCED. SERVICE OR REPLACE SYSTEM IAW 181.420 OF THIS PART
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2021
Resolved 19 August 2021
Resolution: Provided service report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2021 Resolved
EACH LIFE RING, LIFE BUOY MUST BE APPROVED IAW 160.050 IN SUBCHAPTER Q OF THIS CHAPTER. RING LIFE BUOY WAS FOUND WITH WATER INTRUSION. MAKE LIFE BUOY WATERTIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2021
Resolved 19 August 2021
Resolution: Ring has been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2021 Resolved
THE LIGHT MUST BE A FLOATING WATERLIGHT APPROVED IAW 161.610 OF THIS PART. MISSING PIN ON FLOATING WATERLIGHT COMPROMISING ABILITY TO FLOAT. FIX PIN; MAKE WATERTIGHT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Light has been repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 August 2021 Resolved
EACH INLET OR PIPED THAT PENETRATES THE HULL BELOW THE WATERLINE MUST HAVE MEANS TO PREVENT WATER FROM ENTERING THE VESSEL. RUDDER POST PACKING WAS FOUND LEAKING EXTENSIVELY. FIX RUDDER POST TO PREVENT EXCESSIVE LEAKING. 46 CFR 171.119(b) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Packing has been tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 August 2021 Resolved
EACH LIFE FLOAT MUST BE FITTED WITH TWO PADDLES LASHED TO THE LIFE FLOAT. ACQUIRE ONE ADDITIONAL PADDLE AND LASH TWO PADDLES TO EACH LIFE FLOAT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Paddle has been provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 August 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2021
Resolved 19 August 2021
Resolution: Provided copy of radio operator permit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2020 Resolved
A vessel must carry a first-aid kit with equivalent contents and instructions. Replace expired pieces with in-date items.
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 23 June 2020
Resolution: First aid kit was insoected and has the required gear.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 May 2020 Resolved
All vessels shall be provided with a satisfactory arrangement for draining. 3-way valve is locked in the open position. Prove proper operation (bilge system).
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 23 June 2020
Resolution: Valve was tested and in good working condition.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 May 2020 Resolved
Portable and semi-portable extinguishers must be inspected and maintained IAW NFPA 10. Inspection sticker was not stamped. Have inspector stamp inspection sticker.
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 23 June 2020
Resolution: Inspection sticker has been updated
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2019 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Vessel is restricted to 26 total persons.
Action required: 705 - Other - as specified
Resolved 19 September 2019
Resolution: Replacement lifejackets placed onboard. Total persons allowed onboard is 32.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2019 Resolved
At least one ring buoy must be fitted with a life line. Each Life line on a ring buoy must have a breaking strength of at least 5 kilonewtons. Line is severely deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Replaced life line.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 August 2019 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA. 10-B:C extinguisher in wheelhouse is not being maintained on a monthly or annual basis. 46 CFR 176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Replacement NEW extinguisher is onboard. Will be placed in the annual inspection cycle starting 2020.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2019 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. One PFD type is not represented on donning placards currently displayed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Newly replaced lifejackets are the same as the donning placard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2019 Resolved
A vessel must carry either a first aid kit approved under 46 CFR 160.041 or a kit with equivalent contents and instructions. First aid kit not complete with required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Updated contents onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2019 Resolved
Each EAP must include at lest the following elements: display & distribution of informational material, community hotline telephone number, and employer's policy regarding drug & alcohol use in the workplace. Drug and alcohol program was missing these elements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: EAP training completed and placard posted.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 May 2019 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Steering gear arm suffered fracture and authorized temporary repair. Replace steering gear arm in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 9 May 2019
Resolution: Steering gear repairs were completed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 May 2019 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subpart may be inspected iaw standards acceptable to the OCMI as good marine practice. Submit repair proposal with means to prevent rudder arm from contacting rudder stops.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 9 May 2019
Resolution: Proposal received via e-mail.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2019 Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office. Vessel did not immediately notify OCMI after steering loss.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2019 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel did not notify cognizant OCMI prior to making temporary repairs to steering arm.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 August 2018 Resolved
Electrical installations shall be to the satisfaction of the [name withheld] end wires identified under ladder to operating station. Remove wires or install cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: Dead ended wires have been put in a J-box.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 August 2018 Resolved
Electrical installations shall be to the satisfaction of the [name withheld] converter box lose under operating station. Fasten/secure to frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: DC converter box has been secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2018 Resolved
Each lifejacket must be marked with retroreflective material. 01 lifejacket found with degraded retro. Replace retro.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: New retro was place on lifejacket.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 August 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: Operator has enrolled in a consortium, expiration date 05/09/2019.
Engineering › Fuel Oil Service System › Hose
Issued 23 August 2017 Resolved
Replace leaking fuel line near fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 24 August 2017
Resolution: A chaffed flexible fuel line was replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 August 2017 Resolved
Repair or replace (02) adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 24 August 2017
Resolution: Corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2017 Resolved
Re-mark vessel name on (01) ring life buoy.
Action required: 705 - Other - as specified
Due 24 September 2017
Resolved 24 August 2017
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 23 August 2017 Resolved
Provide proper chafing protection on the following: (1) Hydraulic hose off main engine, port side; (2) Bilge discharge pipe at hull, port side
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 24 August 2017
Resolution: Corrected.
Communications › Alarms/Indicators › High Water Alarm
Issued 29 August 2016 Resolved
High water alarm for e/r bilge is inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2016
Resolved 31 August 2016
Resolution: proper operation was proven.
Communications › Radio Communications › EPIRB
Issued 29 August 2016 Resolved
Hydrostatic release unit for EPIRB needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 31 August 2016
Resolution: HRU was deemed acceptable.

Casualty record · 4

9 May 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4860202
1 May 2019Routine · role: Involved in a Marine Casualty · activity 6674048
24 June 2022Routine · role: Involved in a Marine Casualty · activity 7485715
7 June 2023Routine · role: Involved in a Marine Casualty · activity 7721791
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.