MAURY USCG vessel records Sign in
← All vessels

SEA LOVE III

SEA LOVE III is a 1985 passenger vessel (inspected). The Coast Guard has recorded 103 inspections since 1985, most recently in July 2026, along with 205 deficiencies, 4 operational controls and 4 casualty investigations between 2014 and 2023.

Records from 1985 to 2026. Most recent: inspection, 5 July 2026.

Built
1985
Last inspected
5 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI6496
254183
Flag
UNITED STATES
367719280
Maury page id
psix-254183

Inspections, by type

…with no type recorded12
Years with a record 38 calendar years (1985–2026)
The 103 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.1 ft × 14.5 ft × 6.1 ft
Registered tonnagegross 33 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA LOVE INC · PONCE INLET, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST AUGUSTINE, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 7 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR4005MMSI 367719280 · active · compulsorily equipped · granted 28 August 2026, expires 28 August 2036
WDI6496MMSI 367719280 · expired · compulsorily equipped · granted 5 March 2016, cancelled 9 May 2026
WSG6725MMSI 367047920 · expired · compulsorily equipped · granted 7 June 2005, cancelled 8 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 103

5 July 2026 Vessel Attendance · Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8429142
31 March 2026 Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8338864
11 June 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8157450
20 May 2025 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8140086
21 April 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8116504
8 January 2025 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8060215
25 November 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8039584
29 October 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8035477
21 August 2024 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7986038
5 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7872357
21 August 2023 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7773542
8 June 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7708163
7 June 2023 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7721791
16 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7535476
24 June 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7485715
23 March 2022 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7404458
18 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7265201
14 April 2021 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7175318
29 May 2020 COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6952432
7 May 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6949937
9 April 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6934277
26 August 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6791654
1 May 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6674048
1 May 2019 Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6674328
28 August 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6517804
17 April 2018 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6393039
15 August 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6241469
29 August 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5983972
26 April 2016 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5863183
12 May 2014 Deficiency Check · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4866352
9 May 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4860202
1 May 2014 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4846611
1 May 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4299811
1 December 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4199334
22 August 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4132087
31 July 2008 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3284882
30 June 2008 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3252542
6 September 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3049612
7 June 2006 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2708004
22 May 2006 Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2655563
7 June 2005 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2382193
18 March 2005 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2313877
25 August 2004 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2176381
6 July 2004 Deficiency Check · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2123483
6 July 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2123527
10 September 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1905399
26 August 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1888530
27 August 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1667701
23 July 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1650669
2 July 2002 Hull Examination · Administrative Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1640137
17 October 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1432558
12 January 2001 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1391455
26 September 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1397501
21 September 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 973
17 July 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 820660
26 June 2000 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1436402
28 January 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 813964
11 January 2000 Type not recorded
No type recorded · USCGC PEA ISLAND (WPB 1347) · USCG Southeast District (CGD-SE) · Activity 1515092
24 August 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1411947
23 June 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1191643
18 September 1998 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1466559
10 September 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 168674
25 August 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1416747
17 July 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1364253
24 June 1997 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1114651
7 May 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1099717
11 October 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 874224
28 August 1996 Re-Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1400411
10 October 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1188725
13 September 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1192002
22 August 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880594
10 March 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 862422
27 July 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1172278
28 June 1994 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 863711
28 June 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1173642
3 May 1994 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1169279
5 August 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 842610
29 June 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1155795
9 November 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 953734
23 September 1992 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 937984
26 June 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 945919
27 May 1992 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 955840
27 December 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1270813
19 August 1991 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1251081
28 June 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1231884
28 June 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1247847
28 November 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 918963
16 August 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 914225
16 July 1990 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1224057
30 June 1989 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1032962
1 June 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1040742
26 July 1988 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1341723
30 June 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1206112
5 January 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1008821
30 October 1987 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1019132
9 July 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1014511
17 February 1987 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1311184
30 September 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1006418
14 August 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1308264
9 August 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1310896
7 August 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1305603
25 July 1986 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1296760
3 July 1985 Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 995599

Deficiency record · 205

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Make necessary repairs to the satisfaction of the attending Coast Guard MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2026
Resolution: Cleaned aftercoller, reinstalled and conducted power trial.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025 Resolved
Eash connection to a conductor or terminal part of a conductor must be made within an enclosure and have a pressure type connector on each conductor. Stern flood light found unwired with wires hanging down, replace wiring connections and conduct operational test. 46 cfr 183.340(g)1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 9 June 2025
Resolution: Corrected wiring
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 May 2025 Resolved
Abandon ship and MOB drill's shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel could not provide adequate log, records of drills, maintenance/testing. Create new boat log and ensure maintenance, testing of lifesaving equipment, and drills are properly logged. 46 cfr 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 9 June 2025
Resolution: Logs being recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2025 Resolved
A fire hose with a nozzle must be attached to each hydrant at all times. Nozzle was missing, replace nozzle. 46cfr181.320(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2025
Resolved 9 June 2025
Resolution: nozzle was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 November 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements... Vessel lost propulsion while operating offshore. Vessel is restricted from carrying passengers until Coast Guard marine inspector attendance.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2024
Resolved 26 November 2024
Resolution: Observed two successive starts of engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2024 Resolved
No alterations that affect the safety of the vessel may be made without OCMI approval. Automatic reels and associated wiring were installed without apoproval.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2025
Resolution: Wiring removed.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 23 August 2024 Resolved
Vessel was not fitted with an Medium Frequency (MF) Radio. Per FCC regs, 47 Part 80.905(a)(2), vessels operating 20 to 100 miles on an oceans route required a MF Radio. 47 CFR 80.903 requires FCC Tech to inspect a SPV and issue a Safety Radiotelephony Certificate (form 824) once every five years. Vessel limited to 20 N miles from shore until FCC Safety Radio Cert/Form 824 issued.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2024
Resolved 21 April 2025
Resolution: FCC Form 824 provided. Deficiency satisfied and cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 August 2024 Resolved
EPIRB Battery expired. Obtain new battery or new EPIRB with proper registration. Until resolved IAW 46 CFR 180.64 & 185.728 vessel limited to 3 N miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 23 August 2024
Resolution: New EPIRB procured, confirmed EPIRB registered.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2024 Resolved
Upon activation, fuel oil remote closing valve cable broke. Fix remote fuel oil shut off valve cable and demo proper operation IAW 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Cable replaced & def corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 August 2024 Resolved
When installed, unable to move steering system emergency tiller bar. Make repairs and demo operation iaw 46 CFR 182.620
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Reviewed hydraulic piping, no cross connect valve. O/O, Master, & CG MI agreed, if system system lost pressure tiller bar could be operated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2024 Resolved
Observed wire hanging near vessels stern light. Properly terminate wire as required by 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: E-mail with statement and photo provided by O/O reflecting deficiency corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 August 2024 Resolved
Steering gear hatch cover gasket worn. Renew steering gear hatch cover gasket iaw 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: E-mail with statement and photo provided by O/O reflecting deficiency corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2024 Resolved
Aft overhead light, portside above fishing deck box, hanging by electrical wire. Properly mount the light fixture iaw 46 CFR 183.410
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 6 September 2024
Resolution: E-mail with statement and photo provided by O/O reflecting deficiency corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2024 Resolved
Child life jacket stowage bag open, whereby mixed with the adult lifejackets. Separate Child life jackets from the adults iaw 46 CFR 180.78
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2024
Resolved 23 August 2024
Resolution: Observed Child Lifejackets stowed and separated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2024 Resolved
Crew unable to pump water thru the fixed bilge system. Make repairs and demo operation iaw (Old TS) 46 CFR 182.25-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Observed crew de-water forward & aft bilges thru the fixed bilge system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 August 2024 Resolved
Noted excessive oil & water observed in forward engine room bilge. Remove excessive oil & water as required by 46 CFR 176.830(b).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2024
Resolved 23 August 2024
Resolution: Observed oil & water removed from bilge.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 22 August 2024 Resolved
Master & Crew have no history of preforming MOB drill. Demonstrate recovery of a man over board and fire drill in presence of an attending CG MI iaw 46 CFR 176
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2024
Resolved 23 August 2024
Resolution: Observed crew preform a satisfactory MOB drill.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 August 2024 Resolved
Vessel not fitted with an official logbook. Place an official log book on the vessel and record; trips, crew, passenger count, EPIRB monthly testing, Lifesaving & Fire fighting inspections, and crew drills, iaw 46 CFR 185.504/.520/.702/.728
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 4 October 2024
Resolution: Viewed and confirmed vessel logbook.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 22 August 2024 Resolved
Missing FCC vessels Radio safety equipment inspections record. Authorized FCC inspector required to check radio installation & provide inspection cert/form 824 to CG MI iaw 47 CFR 80.13. 04OCT24 requirement extended, to be resolved by 23OCT2024.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2024
Resolved 4 November 2024
Resolution: Received copy of FCC Radio Cert
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 August 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2024
Resolved 12 November 2024
Resolution: Received an e-mail with statements and supporting documents reflecting company compliant with DAPI requirements per 46 CFR Part 16
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 March 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Add fire detector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2024
Resolved 11 March 2024
Resolution: Vessel installed smoke detector in the main cabin area.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 August 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 12 February 2024
Resolution: Company rep provided e-mail, with statement and proof requirement satisfied.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 August 2023 Resolved
Observed three "orange" day light flares were expired. O/O to obtain three new CG approved day light flares as required by 46 CFR 180.68. Replacement flares shall be onboard the vessel prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2023
Resolved 25 August 2023
Resolution: Received an e-mail with statement & photos reflecting 6 new orange flares were procured and placed onboard the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 August 2023 Resolved
Observed several first aid kit items; aspirin, eye wash solution, ointment were expired. All expired items shall be renewed and the content of the first aid kit must comply with 46 CFR 160.041 as required by 46 CFR 184.710. Requirement to be rectified within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting new First Aid Kit items were placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2023 Resolved
Observed one life float painter was dry-rotten, port life float lantern lens was worn, and both water life float water lights to be non-serviceable. O/O shall renew life float painter, lantern, and water lights as required by 46 CFR 180.137. Requirement to be rectified within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting replacement of painter.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 23 August 2023 Resolved
Portable extinguishers and engine room fixed system last serviced August 2022. Serving scheduled for next week. As required by 46 CFR 176.810(7)(B), after servicing, provide copy of third party serving report to attending CG Marine Inspector. Requirement to be rectified within 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 29 August 2023
Resolution: Service reports provided, reviewed and requirement satisfied.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 August 2023 Resolved
Observed pilot house bilge alarm box fitted with audible alarm/horns and LED lights. Confirmed audible alarm, although all LED's broken and did not illuminate, as required by 46 CFR 182.530. O/O, to renew existing bilge alarm panel or renew all LED lights. Requirement to be rectified within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting replacement of LED lights on alarm box.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 23 August 2023 Resolved
Companies DOT alcohol test strips expired. Company to procure new DOT approved alcohol test strip as required by 46 CFR Part 16.240. Recommended a few alcohol test strips be placed onboard the vessel. Rectify deficiencies with in 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos reflecting procurement of new alcohol strips.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2023 Resolved
List reflecting employee's enrolled in random chemical testing program was not available. Company to provide 3rd party consortium list reflecting current employee's enrolled in the random chemical testing program as required by 46 CFR 16.230.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 6 September 2023
Resolution: Received an e-mail with statement & photos of DAPI enrolled employees.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 August 2022 Resolved
A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”. Distress signals not properly marked.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 August 2022
Resolved 9 September 2022
Resolution: Signals properly Maked
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 August 2022 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q. Float light for life float inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 9 September 2022
Resolution: Waterlight replace
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2022 Resolved
If of the garden type, be of a good commercial grade constructed of an inner rubber tube, plies of braided fabric reinforcement, and an outer cover of rubber or equivalent material, and of sufficient strength to withstand the maximum pressure that can be produced by the fire pump. All fittings on the hose must be of suitable corrosion-resistant material. Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Fire hose found leaking and missing nozzle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 9 September 2022
Resolution: Fire hose replaced
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 16 August 2022 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency procedures typo.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 9 September 2022
Resolution: Procedures updated
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 August 2021 Resolved
FIXED GAS FIRED EXTINGUISHING SYSTEMS, THE INSPECTIONS, AND TEST IAW TABLE 176.810(B) OF THIS PART IN ADDITION TO REQUIRED TESTING. THE PRE-ENGINEERED FIXED EXTINGUISHING SYSTEM WAS FOUND IN A RECHARGE STATUS ON GUAGE. SERVICING RECORDS COULD NOT BE PRODUCED. SERVICE OR REPLACE SYSTEM IAW 181.420 OF THIS PART
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2021
Resolved 19 August 2021
Resolution: Provided service report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2021 Resolved
EACH LIFE RING, LIFE BUOY MUST BE APPROVED IAW 160.050 IN SUBCHAPTER Q OF THIS CHAPTER. RING LIFE BUOY WAS FOUND WITH WATER INTRUSION. MAKE LIFE BUOY WATERTIGHT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2021
Resolved 19 August 2021
Resolution: Ring has been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2021 Resolved
THE LIGHT MUST BE A FLOATING WATERLIGHT APPROVED IAW 161.610 OF THIS PART. MISSING PIN ON FLOATING WATERLIGHT COMPROMISING ABILITY TO FLOAT. FIX PIN; MAKE WATERTIGHT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Light has been repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 August 2021 Resolved
EACH INLET OR PIPED THAT PENETRATES THE HULL BELOW THE WATERLINE MUST HAVE MEANS TO PREVENT WATER FROM ENTERING THE VESSEL. RUDDER POST PACKING WAS FOUND LEAKING EXTENSIVELY. FIX RUDDER POST TO PREVENT EXCESSIVE LEAKING. 46 CFR 171.119(b) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Packing has been tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 August 2021 Resolved
EACH LIFE FLOAT MUST BE FITTED WITH TWO PADDLES LASHED TO THE LIFE FLOAT. ACQUIRE ONE ADDITIONAL PADDLE AND LASH TWO PADDLES TO EACH LIFE FLOAT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 19 August 2021
Resolution: Paddle has been provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 August 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2021
Resolved 19 August 2021
Resolution: Provided copy of radio operator permit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2020 Resolved
A vessel must carry a first-aid kit with equivalent contents and instructions. Replace expired pieces with in-date items.
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 23 June 2020
Resolution: First aid kit was insoected and has the required gear.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 May 2020 Resolved
All vessels shall be provided with a satisfactory arrangement for draining. 3-way valve is locked in the open position. Prove proper operation (bilge system).
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 23 June 2020
Resolution: Valve was tested and in good working condition.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 May 2020 Resolved
Portable and semi-portable extinguishers must be inspected and maintained IAW NFPA 10. Inspection sticker was not stamped. Have inspector stamp inspection sticker.
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 23 June 2020
Resolution: Inspection sticker has been updated
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2019 Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Vessel is restricted to 26 total persons.
Action required: 705 - Other - as specified
Resolved 19 September 2019
Resolution: Replacement lifejackets placed onboard. Total persons allowed onboard is 32.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2019 Resolved
At least one ring buoy must be fitted with a life line. Each Life line on a ring buoy must have a breaking strength of at least 5 kilonewtons. Line is severely deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Replaced life line.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 August 2019 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA. 10-B:C extinguisher in wheelhouse is not being maintained on a monthly or annual basis. 46 CFR 176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Replacement NEW extinguisher is onboard. Will be placed in the annual inspection cycle starting 2020.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2019 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. One PFD type is not represented on donning placards currently displayed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Newly replaced lifejackets are the same as the donning placard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 August 2019 Resolved
A vessel must carry either a first aid kit approved under 46 CFR 160.041 or a kit with equivalent contents and instructions. First aid kit not complete with required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: Updated contents onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2019 Resolved
Each EAP must include at lest the following elements: display & distribution of informational material, community hotline telephone number, and employer's policy regarding drug & alcohol use in the workplace. Drug and alcohol program was missing these elements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 19 September 2019
Resolution: EAP training completed and placard posted.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 May 2019 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Steering gear arm suffered fracture and authorized temporary repair. Replace steering gear arm in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 9 May 2019
Resolution: Steering gear repairs were completed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 May 2019 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subpart may be inspected iaw standards acceptable to the OCMI as good marine practice. Submit repair proposal with means to prevent rudder arm from contacting rudder stops.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 9 May 2019
Resolution: Proposal received via e-mail.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2019 Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office. Vessel did not immediately notify OCMI after steering loss.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2019 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel did not notify cognizant OCMI prior to making temporary repairs to steering arm.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 August 2018 Resolved
Electrical installations shall be to the satisfaction of the [name withheld] end wires identified under ladder to operating station. Remove wires or install cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: Dead ended wires have been put in a J-box.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 August 2018 Resolved
Electrical installations shall be to the satisfaction of the [name withheld] converter box lose under operating station. Fasten/secure to frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: DC converter box has been secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2018 Resolved
Each lifejacket must be marked with retroreflective material. 01 lifejacket found with degraded retro. Replace retro.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: New retro was place on lifejacket.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 August 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2018
Resolved 27 September 2018
Resolution: Operator has enrolled in a consortium, expiration date 05/09/2019.
Engineering › Fuel Oil Service System › Hose
Issued 23 August 2017 Resolved
Replace leaking fuel line near fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 24 August 2017
Resolution: A chaffed flexible fuel line was replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 August 2017 Resolved
Repair or replace (02) adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 24 August 2017
Resolution: Corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2017 Resolved
Re-mark vessel name on (01) ring life buoy.
Action required: 705 - Other - as specified
Due 24 September 2017
Resolved 24 August 2017
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 23 August 2017 Resolved
Provide proper chafing protection on the following: (1) Hydraulic hose off main engine, port side; (2) Bilge discharge pipe at hull, port side
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 September 2017
Resolved 24 August 2017
Resolution: Corrected.
Communications › Alarms/Indicators › High Water Alarm
Issued 29 August 2016 Resolved
High water alarm for e/r bilge is inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2016
Resolved 31 August 2016
Resolution: proper operation was proven.
Communications › Radio Communications › EPIRB
Issued 29 August 2016 Resolved
Hydrostatic release unit for EPIRB needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 31 August 2016
Resolution: HRU was deemed acceptable.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 May 2014 Resolved
Repair/replace missing aluminum handrail on pier side steps.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 12 June 2014
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 May 2014 Resolved
Remove slipping hazard created by makeshift step (milk crate). Step is not secured to the deck of the vessel.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 12 June 2014
Stability › Weathertight Integrity › General
Issued 1 May 2012 Resolved
Replace all broken glass windows in way of pilot house.
Due 23 May 2012
Resolved 16 May 2012
Resolution: Vessel representative emailed photos of all newly replaced windows. Windows, all sat.
Construction/Loadline › Structures › Ventilators
Issued 1 May 2012 Resolved
Seal vent on starboard cabin top.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2012
Resolution: Regasketed vent.
Engineering › Steering Gear System › Hydraulic Hose
Issued 1 May 2012 Resolved
Repair/replace hydraulic hose in way of HPU on port side of MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2012
Resolution: Repaired leaky hose.
Lifesaving › Lifejacket/PFD (Type II) › Lights
Issued 12 September 2008 Resolved
Renew expired lifejacket lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 September 2008 Resolved
Repair Starboard navigation light and ensure proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 12 September 2008 Resolved
Repair Single Side band radio and ensure proper operation. Single Side Band must be repaired prior to vessel operation more than 20 mile from a Harbor of Safe Refuge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2008
Resolved 9 October 2008
Lifesaving › Lifefloat › Serviceable
Issued 12 September 2008 Resolved
Renew or repair port lifefloat. Vessel is restricted to 20 miles from shore until life float is repaired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2008
Resolved 9 October 2008
Resolution: Replaced port lifefloat with new lifefloat.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 September 2008 Resolved
Install remote fuel shutoff on fuel line piping.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 September 2008 Resolved
Properly pipe engine cooling system piping and remove PCV piping.
Condition: Placed in Improper Service
Due 12 October 2008
Resolved 9 October 2008
Communications › Visual Communication › Warning Sign (gangway)
Issued 12 September 2008 Resolved
Post all Instructions: life jacket placards, emergency instructions.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 12 September 2008 Resolved
Demonstrate proper operation of bilge pump alarm sensors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 12 September 2008 Resolved
Install high level alarm in steering compartment. Until repaired vessel is allowed to operate as long as inspection of steering compartment is conducted every two hours.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 18 September 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 12 September 2008 Resolved
Install all seating and lavatory facilities.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Lifesaving › Lifefloat › Painter
Issued 12 September 2008 Resolved
Renew Seapainter line on lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 12 September 2008 Resolved
Provide original master license.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 12 September 2008 Resolved
Provide valid FCC marine radio operators permit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 9 October 2008
Lifesaving › Lifebuoys › Serviceable
Issued 30 June 2008 Resolved
Renew Retro on Lifering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 June 2006 Resolved
Stairs leading up to pilot house are broken and rotten, renew stairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Resolution: Stairs renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 9 June 2006 Resolved
Transverse deck frame in aft of engine room is wasted, renew frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Resolution: Frame renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 9 June 2006 Resolved
Transverse frame on starboard side forward of tank room is broken, renew frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Resolution: Frame renewed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 June 2005 Resolved
Renew / Repair fixed seating on port side.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Lifesaving › Buoyant Apparatus › Lifeline
Issued 7 June 2005 Resolved
Renew line on lifefloat and life buoy.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 June 2005 Resolved
Repair corroded terminals on fireboy bus terminal.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Engineering › Bilge Water Management System › Piping
Issued 7 June 2005 Resolved
Renew gate valve handle on aft bilge line in steering room.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Engineering › Bilge Water Management System › Piping
Issued 7 June 2005 Resolved
Double clamp all piping in steering room and MSD space.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 7 June 2005 Resolved
Repair deck where soft at forward bulkhead in MSD space.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 7 June 2005 Resolved
Renew port forward engine room vent.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Engineering › Bilge Water Management System › Not Installed
Issued 7 June 2005 Resolved
Install bilge high level alarm in MSD space.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 7 June 2005 Resolved
Provide means to recover man overboard.
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 7 July 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 August 2004 Resolved
CONDUCT ANNUAL TESTING OF PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY 46CFR176.810(b)(1).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 25 August 2004
Resolution: Fire Fighters Equipment Co. inspected portable fire extinguishers. Sea Love Charters submitted inspection receipt as evidence of inspection; paid for with check #12605.
Communications › Audible Communications › Bell
Issued 25 August 2004 Resolved
OUTFIT BELL AND MOUNT ON VSL AS REQUIRED BY 33CFR86 AND COLREGS RULE 33 (INLAND NAVIGATION RULES, RULE 33)
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 14 September 2004
Resolution: Sea Love Charters submitted photograph to MSO Jacksonville. Photo depicts bell mounted just to port of centerline above the forward windows on the pilothouse.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2004 Resolved
COMPLETE CREDIT DRYDOCK AND INTERNAL STRUCTURAL EXAMINATIONS PRIOR TO CARRYING PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 16 July 2004
Fire Fighting › Fire Main › Material
Issued 6 July 2004 Resolved
RENEW BILGE AND FIRE SYSTEM PIPING WITH FERROUS MATERIAL. PROVE PROPER OPERATION OF SAME WHEN COMPLETED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2004
Resolved 16 July 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2004 Resolved
STENCIL NAME, REMEW RETRO-REFLECTIVE TAPE AND BATTERY ON FORWARD RING BUOY.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 16 July 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 July 2004 Resolved
PROVIDE PLAN FOR FRAME REPLACEMENT / RENEWAL FOR ENTIRE STRUCTURE IN ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 16 July 2004
Construction/Loadline › Hull › Side Shell
Issued 6 July 2004 Resolved
REPAIR RUBRAIL WHERE MISSING AND REPLACE METAL PROTECTIVE SLEAVE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2004
Resolved 18 March 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 6 July 2004 Resolved
PROVIDE VENTILATION SHUTDOWNS FOR ENGINE ROOM SPACE WHEN FIXED FIRE FIGHTING IS ACTIVATED.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 August 2004
Resolved 18 March 2005
Electrical › Lighting (service)
Issued 26 August 2003 Resolved
Anchor light not working properly, LEGACY COMPONENT DESC: Lighting Fixture
Due 26 September 2003
Resolved 10 September 2003
Engineering › Bilge Water Management System
Issued 26 August 2003 Resolved
bilge piping found lose at manifold just fwd of engine piping is PVC joint lose. LEGACY COMPONENT DESC: Piping
Due 26 September 2003
Resolved 10 September 2003
Lifesaving › Lifejacket/PFD (General)
Issued 26 August 2003 Resolved
Life jackets donning placard missing, replace placard with approved type LEGACY COMPONENT DESC: Storage
Due 26 September 2003
Resolved 10 September 2003
Electrical › Lighting (service)
Issued 26 August 2003 Resolved
Light fixture missing in engine room, Dead end wires from light fixtures hanging LEGACY COMPONENT DESC: Lighting Fixture
Due 26 September 2003
Resolved 10 September 2003
Engineering › Sea-water System (primary cooling)
Issued 26 August 2003 Resolved
double clamp missing on S/W injection piping, just before exhaust riser LEGACY COMPONENT DESC: Piping
Due 26 September 2003
Resolved 10 September 2003
Lifesaving › Buoyant Apparatus
Issued 26 August 2003 Resolved
Life Float tagg lines shows signs of weathering, LEGACY COMPONENT DESC: Tag Lines
Due 26 September 2003
Resolved 10 September 2003
Operations/Management › Drills/Instruction
Issued 26 August 2003 Resolved
Waste Managament plan missing from vessel
Due 26 September 2003
Resolved 10 September 2003
Personnel › Training
Issued 26 August 2003 Resolved
Crew members could not produce there CPR cards while on board LEGACY COMPONENT DESC: First Aid/CPR
Due 26 September 2003
Resolved 10 September 2003
Accommodation/Occupational Safety
Issued 23 July 2002 Resolved
MAKE PERMANENT REPAIRS TO THE PORT AFT BENCH SEAT PRIOR TO ALLOWING PASSENGERS TO UTILIZE BENCH. LEGACY COMPONENT DESC: BENCH SEAT
Condition: Improper/Lack of Maintenance
Due 30 July 2002
Resolved 10 September 2003
Engineering › Bilge Water Management System › Hose
Issued 2 July 2002 Resolved
Double clamp primary bilge line at manifold.
Condition: Improper/Lack of Maintenance
Due 10 July 2002
Resolved 10 July 2002
Construction/Loadline › Hull
Issued 2 July 2002 Resolved
Renew the following overhead frames in the tank room, Strbd side #2 and 3, plywood strong back between #2 and 3 on strbd, inboard long frame at hatch, #4 overhead from centerline out to strbd and #2 overhead on port side. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Due 10 July 2002
Resolved 10 July 2002
Construction/Loadline › Hull
Issued 2 July 2002 Resolved
Repair section of strut under shaft log at the #2 timber. LEGACY COMPONENT DESC: Keel
Condition: Unknown
Due 10 July 2002
Resolved 10 July 2002
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 2 July 2002 Resolved
Proberly secure MSD overboard discharge valve.
Condition: Improper/Lack of Maintenance
Due 10 July 2002
Resolved 10 July 2002
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 July 2002 Resolved
Make proper repairs to forward bulkhead in tank room as marked.
Condition: Improper Installation
Due 10 July 2002
Resolved 10 July 2002
Operations/Management › Pollution
Issued 2 July 2002 Resolved
Remove all oil in forepeak, V berth and engine room bilges LEGACY COMPONENT DESC: Retention of Oily Mixture
Condition: Improper/Lack of Maintenance
Due 10 July 2002
Resolved 10 July 2002
Engineering › Steering Gear System
Issued 2 July 2002 Resolved
Renew two hydraulic lines at pump in engine room, install chaffing clamp and chaff same in V berth space. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper/Lack of Maintenance
Due 10 July 2002
Resolved 10 July 2002
Engineering › Steering Gear System › Bracket/Clamp
Issued 2 July 2002 Resolved
Reclamp steering gear lines in engine room.
Condition: Improper/Lack of Maintenance
Due 10 July 2002
Resolved 10 July 2002
Engineering › Steering Gear System › Fastener
Issued 2 July 2002 Resolved
Renew bolt from steering ram to tiller to remove slack.
Condition: Improper/Lack of Maintenance
Due 10 July 2002
Resolved 10 July 2002
Lifesaving
Issued 26 September 2000 Resolved
PROVIDE VESSELS NANE ON RING BUOY.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Construction/Loadline
Issued 26 September 2000 Resolved
TIGHTEN STR GEAR ROOM BILGE PUMP OVBD CONNECTION THRU HULL.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Construction/Loadline
Issued 26 September 2000 Resolved
REFASTEN AND REBUILD STND BOW RAIL AND GUNWALE.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Lifesaving
Issued 26 September 2000 Resolved
PROVIDE OPERATIONAL STROBE LIGHT FOR THE RING BUOY.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Lifesaving
Issued 26 September 2000 Resolved
PROVIDE RETRO TAPE FOR THE RING BUOY.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Construction/Loadline
Issued 26 June 2000 Resolved
Repair broken rub rails on Stbd side bow area.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Construction/Loadline
Issued 26 June 2000 Resolved
Repair/replace FWD escape hatch to make weather tight.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Accommodation/Occupational Safety
Issued 26 June 2000 Resolved
Repair/ repair intercomm system
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 26 June 2000 Resolved
Remove flexable fuel hose in engine room and replace with approved fuel piping.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 28 January 2000 Resolved
INSTALL A FIXED FIREFIGHTING SYSTEM FOR THE ENGINEROOM.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Fire Fighting
Issued 24 August 1999 Resolved
INSTALL A FIXED FIREFIGHTING SYSTEM FOR THE E/R.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 24 August 1999 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS FOR THE COMPARTMENTS WITH THRU HULL FITTINGS.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 24 August 1999 Resolved
PACK HYDRAULIC HOSES TO FORE PEAK THROUGH HULL BULKHEAD HOLES.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Electrical
Issued 24 August 1999 Resolved
PORT SIDE PILOTHOUSE ELECTRICAL BOX NEEDS A COVER.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Accommodation/Occupational Safety
Issued 24 August 1999 Resolved
REPAIR FOUNDATION UNDER PORT SIDE SEAT PIANO HINGE ON WEATHER DECK.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Electrical
Issued 24 August 1999 Resolved
PORT E/R LIGHT GLASS IS CRACKED AND WATER IS INSIDE GLOBE.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Electrical
Issued 24 August 1999 Resolved
DEAD END ALL BARE WIRES THROUGHOUT VESSEL. (UNDER BRIDGE CONSOLE, STEERING GEAR AND FUEL TANK COMPARTMENTS.)
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Navigation
Issued 24 August 1999 Resolved
STEERING GEAR LINKAGE BOLT NEEDS TO BE TIGHTENED ON THE QUADRANT.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Construction/Loadline
Issued 24 August 1999 Resolved
LOBBY DRAIN LINE NEEDS TO BE REATTACHED IN THE STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Navigation
Issued 24 June 1997 Resolved
Repair/renew broken tiller arm.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Lifesaving
Issued 24 June 1997 Resolved
Provide an approved storage container for distress signals in accordance with 46CFR part 185.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Navigation
Issued 24 June 1997 Resolved
Provide updated navigation chart for area of ops according to COI.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Navigation
Issued 24 June 1997 Resolved
Provide current Coast Pilot, Tide & Current tables, & Light List.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Documentation
Issued 24 June 1997 Resolved
Provide COD to reflect new owner.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Construction/Loadline
Issued 24 June 1997 Resolved
Repair coaming on aft steering hatch.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Fire Fighting
Issued 7 May 1997 Resolved
RENEW DISCHARGED B-II FIRE EXTINGUISHER PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 14 May 1997
Resolved 16 May 1997
Fire Fighting
Issued 7 May 1997 Resolved
RECHARGE AND REMOUNT B-I FIRE EXTINGUISHER PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 14 May 1997
Resolved 16 May 1997
Lifesaving
Issued 7 May 1997 Resolved
RENEW LIFEFLOAT SEA PAINTER, WEAK LINK AND WATER LIGHT LANYARD PRIOR TO THECARRIAGE OF PASSENGERS.
Condition: Unknown
Due 14 May 1997
Resolved 16 May 1997
Construction/Loadline
Issued 28 August 1996 Resolved
PROVIDE 6" COMBING BOARDS IN THE MAIN CABIN DOORWAYS OF THE MAIN CABIN. BOARDS MISSING ON THE AFT AND STBD SIDES.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Electrical
Issued 28 August 1996 Resolved
SECURE THE STEERING COMPARTMENT 12V BILGE PUMP TO THE VESSEL. PROPERLY CONNECT THE 12V WIRING, REMOVE THE TWIST/TAPE.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Documentation
Issued 28 August 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Lifesaving
Issued 28 August 1996 Resolved
RENEW RETROREFLECTIVE TAPE ON ALL LIFE PRESERVERS._x001C_
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Fire Fighting
Issued 28 August 1996 Resolved
PROVIDE AN APPROVED HAND PORTABLE FIRE EXTINGUISHER BRACKET, LOWER PASSENGER CABIN.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Electrical
Issued 28 August 1996 Resolved
PROVIDE A ELECTRICAL WIRING JUNCTION BOX, AFT IN CABIN OVERHEAD, ADJACENT TO THE FISH BOX. REMOVE ALL DEAD END WIRING FROM THE ENGINE COMPARTMENT, FUEL TANK COMPARTMENT, AND LOWER PASSENGER CABIN.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Fire Fighting
Issued 28 August 1996 Resolved
PROVIDE A HAND PORTABLE BILGE/FIRE PUMP.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Construction/Loadline
Issued 28 August 1996 Resolved
MAIN DECK: REPAIR AND PROVE PROPER OPERATION OF MAIN DECK HATCHES, IN WAY OF SECURING DEVICES AND ADRIFT LINE'S/CHAINS.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Accommodation/Occupational Safety
Issued 28 August 1996 Resolved
THE ESCAPE HATCH SECURING DEVICE IN THE LOWER PASSENGER CABIN COMPARTMENT IS FROZEN OPEN. REPAIR AND PROVE PROPER OPERATION OF BOTH SECURING DEVICES.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Electrical
Issued 28 August 1996 Resolved
PROVIDE STARTING AND EQUIPMENT BATTERY TERMINAL PROTECTION.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Lifesaving
Issued 28 August 1996 Resolved
PROVIDE PLACARDS FOR THE ADULT AND CHILDREN LIFE JACKET STORAGE LOCKERS, EMERGENCY FUEL OIL SHUT OFF VALVE AND A EMERGENCY ESCAPE HATCH IN THE LOWERCABIN.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Lifesaving
Issued 28 August 1996 Resolved
INSTALL WATERLIGHT TO RING BUOY WITH A FLOAT TYPE LINE._x001C_ REMARK THE RING BUOY AND LIFE FLOAT WITH THE VESSEL'S NAME.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Lifesaving
Issued 28 August 1996 Resolved
PRIVIDE LOGS, TRAINING LOG'S AND DOCUMENTATION IN ACCORDANCES WITH NEW SUB T REGULATIONS. 185.420, 185.502, 185.503, 185.504, 185.506, 185.510., 185.516, 185.520, 185.524, 185.604, AND 185.606.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Accommodation/Occupational Safety
Issued 28 August 1996 Resolved
REPAIR SEWAGE LEAK TO HOLDING TANK IN WAY OF A LEAKING PIPE PLUG, STBD SIDE.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Deck/Cargo
Issued 22 August 1995 Resolved
RENEW DETERIORATED HYDRAULIC SUPPLY/RETURN HOSE FOR ANCHOR CAPSTAN.
Condition: Unknown
Due 29 August 1995
Resolved 26 August 1995
Lifesaving
Issued 22 August 1995 Resolved
PROVIDE TWO PADDLES, MIN 4 FT IN LENGTH FOR LIFEFLOAT, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 26 August 1995
Resolved 26 August 1995
Navigation
Issued 22 August 1995 Resolved
PROVIDE PROPER CHARTS/PUBS APPLICABLE TO ROUTE LISTED ON CURRENT COI.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Documentation
Issued 22 August 1995 Resolved
ARRANGE TO CONDUCT A STABILITY TEST WITH A MARINE INSPECTOR FROM THE COGNIZANT OCMI.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Electrical
Issued 22 August 1995 Resolved
PROVIDE WIRING DIAGRAM AND CHARACTERISTICS OF 12 VDC ENGINE STARTING SYSTEM.
Condition: Unknown
Due 1 October 1995
Resolved 11 September 1995
Fire Fighting
Issued 22 August 1995 Resolved
PROVIDE ADEQUATE NOZZLE FOR FIREHOSE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 26 August 1995
Resolved 26 August 1995
Electrical
Issued 28 June 1994 Resolved
REMOVE ALL WIRE NUTS AND PROVIDE PROPER RUNS AND METAL BRACKET SUPPORT CLIPS TO WIRING THROUGHOUT THE VESSEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 June 1994
Resolved 28 June 1994
Construction/Loadline
Issued 28 June 1994 Resolved
EFFECT PERMANENT REPAIRS TO THE DECK DRAIN PVC PIPING TO ALLOW FOR PROPER DRAINAGE.
Condition: Unknown
Due 28 June 1994
Resolved 28 June 1994
Electrical
Issued 28 June 1994 Resolved
REMOVE ALL DEAD END WIRING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 28 June 1994
Resolved 28 June 1994
Construction/Loadline
Issued 28 June 1994 Resolved
EFFECT PERMANENT REPAIRS TO PROVE PROPER OPERATION OF THE WATER WASHDOWN PUMP.
Condition: Unknown
Due 28 June 1994
Resolved 28 June 1994
Construction/Loadline
Issued 3 May 1994 Resolved
Scrape and apply wood oil/preservative to deck framing in overhead of engine compartment showing angel hair deterioration.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 29 June 1993 Resolved
PLACE A PROPERLY OPERATING SINGLE SIDE BAND RADIO ON BOARD. VESSEL ROUTE ISLIMITED TO NOT MORE THAN 20 MILES OFFSHORE UNTIL SSB INSTALLED.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Engineering
Issued 26 June 1992 Resolved
PROVIDE ONE 2 1/2" DIAMETER GOOSENECK VENT TO THE DIESEL FUEL TANK COMPART-MENT AS REQ'D BY 46CRF182.20-50.
Condition: Unknown
Due 26 June 1992
Resolved 26 June 1992
Electrical
Issued 28 June 1991 Resolved
REMOUNT AND PROVE PROPER OPERATION OF, OR REMOVE, ALL 12 VOLT LIGHTING FIXTURES IN EACH COMPARTMENT AND ON THE OPEN DECK.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Documentation
Issued 28 June 1991 Resolved
PROVIDE AN UPDATED COPY OF THE NAVIGATION RULES, WHICH IS TO REMAIN ABOARD THE VESSEL AT ALL TIMES.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Engineering
Issued 28 June 1991 Resolved
PROVIDE GUARDS ON THE MAIN ENGINE FOR THE ALTERNATOR AND BILGE PUMP PULLEY AND BELTS.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Engineering
Issued 28 June 1991 Resolved
PROVIDE ENGINE COMPARTMENT VENT COVERS.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Accommodation/Occupational Safety
Issued 28 June 1991 Resolved
PROVE PROPER OPERATION OF OR REMOVE THE FRESH WATER TANK AND SYSTEM.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Construction/Loadline
Issued 28 June 1991 Resolved
REMARK THE BILGE PUMPING MANIFOLD WITH PERMANENT LABELS OR MARKINGS.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Accommodation/Occupational Safety
Issued 28 June 1991 Resolved
PROVE PROPER OPERATION OF THE TOILET FLUSH SUPPLY WATER.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Accommodation/Occupational Safety
Issued 28 June 1991 Resolved
PROVE PROPER OPERATION OF THE WASH BASIN OR REMOVE SAME.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Electrical
Issued 28 June 1991 Resolved
RECONNECT THE GROUND WIRING ON A GATE VALVE IN THE STEERING GEAR ROOM.
Condition: Unknown
Due 19 July 1991
Resolved 20 August 1991
Construction/Loadline
Issued 16 July 1990 Resolved
INSTALL NEW GASKET MATERIAL FOR ALL DECK HATCHES AND DEMONSTRATE PROPER OPERATION OF SECURING DEVICES. HATCHES ARE TO REMAIN SECURED.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Lifesaving
Issued 16 July 1990 Resolved
DEMONSTRATE PROPER OPERATION OF THE VESSEL'S EMERGENCY POSITION INDICATING RADIO BEACON (EPIRB). THE VESSEL'S ROUTE IS RESTRICTED TO NO MORE THAN TWENTY (20) MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS DISCREPANCY HAS BEEN CORRECTED.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Engineering
Issued 16 July 1990 Resolved
INSTALL A DRIP PAN UNDER THE MAIN ENGINE FUEL FILTER.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Engineering
Issued 16 July 1990 Resolved
MARK THE LOCATION OF THE EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Electrical
Issued 16 July 1990 Resolved
REMOVE ELECTRICAL CABLES/WIRING FROM BILGES AND SECURE SAME.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Engineering
Issued 16 July 1990 Resolved
TIGHTEN THE SHAFT PACKING.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Accommodation/Occupational Safety
Issued 30 June 1988 Resolved
PROVIDE AND PROVE PROPER OPERATION FOR THE 12V TOILET SALT WATER PUMP.
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Engineering
Issued 30 June 1988 Resolved
FASTENED 12V BILGE PUMPS IN BOTH THE TANK AND STEERING COMPARTMENTS.
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Accommodation/Occupational Safety
Issued 30 June 1988 Resolved
EFFECT PERMANENT REPAIRS TO THE VESSEL'S 3"DIA. MSD HOLDING TANK DISCHARGE LINE, PORT SIDE.
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Lifesaving
Issued 30 June 1988 Resolved
PROVIDE AN APPROVED FLOAT FREE LINK FOR THE VESSEL'S 22 PERSON LIFE FLOAT.
Condition: Unknown
Due 30 June 1988
Resolved 30 June 1988
Fire Fighting
Issued 9 July 1987 Resolved
SERVICE PROPERLY THE INSTALLED FIXED HALON 1301 SYSTEM.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Fire Fighting
Issued 9 July 1987 Resolved
PROVIDE ONE (1) B-II APPROVED TYPE FOR PASSENGER SPACE.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Unknown
Issued 14 August 1986 Resolved
MODIFY DECK AND ENGINE HATCH IN WAY OF ENGINE TURBOCHARGERS TO ALLOW FOR AIR CIRCULATION AND PROPER SPACING OF WOOD FROM TURBOS.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Unknown
Issued 7 August 1986 Resolved
ITEMS D2, D4, D5, E1 ON CG835 DATED 7/25/86 AND ITEMS NO.2, 11, 12 ON WORK LIST DATED 7/25/86 ARE REQUIRED TO BE COMPLIED WITH PRIOR TO CARRYING PASSENGERS AND NOT LATER THAN 14 AUGUST 1986.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Lifesaving
Issued 25 July 1986 Resolved
ATTACH A WATERLIGHT TO LIFE RING BUOY AND LIFEFLOAT.PROPERLY ATTACH LIFEFLOAT PAINTER AND FLOAT FREE LINK.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Fire Fighting
Issued 25 July 1986 Resolved
INSTALL TWO B-II FIRE EXTINGUISHERS IN PASSENGER CABIN.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Fire Fighting
Issued 25 July 1986 Resolved
INSTALL TWO FIRE HOSES WITH NOZZLES AND/OR ISOLATION VALVES PORT AND STBD.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Electrical
Issued 25 July 1986 Resolved
A WORKLIST OF MINOR ITEMS NEEDING ATTENTION WAS ISSUED TO THE VESSEL OPERATOR.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Lifesaving
Issued 25 July 1986 Resolved
PREPARE AND POST EMERGENCY CHECK-OFF LIST AND LIFE PRESERVER DONNING INSTRUCTIONS.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Construction/Loadline
Issued 25 July 1986 Resolved
SUBMIT PREPOSAL TO MODIFY THE WOODEN DECK AND ENGINEROOM HATCH COVER TO ALLOW A SAFE DISTANCE BETWEEN THE ENGINE TURBO CHARGERS AND THE DECK, PREPOSAL SHALL INCLUDE METHOD OF INSULATING OR INSTALLING FIRE RETARDENT MATERIALS TO THE WOODEN DECK IN WAY OF THE TURBO CHARGERS.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Construction/Loadline
Issued 25 July 1986 Resolved
ADJUST DOGS ON WATERTIGHT HATCHES FWD.& AFT. MAIN DECK.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986
Engineering
Issued 25 July 1986 Resolved
MAKE NECESSARY REPAIRS TO THE INSULATION ON BOTH TURBO CHARGERS AND EXHAUST SYSTEMS.
Condition: Unknown
Due 25 July 1986
Resolved 25 July 1986

Casualty record · 4

9 May 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4860202
1 May 2019Routine · role: Involved in a Marine Casualty · activity 6674048
24 June 2022Routine · role: Involved in a Marine Casualty · activity 7485715
7 June 2023Routine · role: Involved in a Marine Casualty · activity 7721791
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record