Records from 1985 to 2026. Most recent: inspection, 9 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 72
9 April 2026
COI Inspection · Drydock Exam · Deficiency Check · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8340578
1 July 2025
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8170408
27 June 2024
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7959511
6 June 2023
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7706525
26 July 2022
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7509948
22 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7337610
24 May 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7205774
6 May 2021
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7202734
30 April 2021
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7186228
22 April 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6946896
16 July 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6766013
21 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6457583
23 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6265028
11 July 2017
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6204356
16 May 2016
COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5886772
11 May 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5875101
24 June 2014
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4897109
14 May 2012
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4310916
8 November 2010
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3996510
16 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3345725
20 August 2008
Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3303725
27 September 2007
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3067146
14 September 2006
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2778020
27 March 2006
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2610447
27 March 2006
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2778984
11 July 2005
COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2419920
20 October 2004
Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2224512
12 April 2004
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040089
5 May 2003
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1785011
22 November 2002
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1706901
13 June 2002
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1634520
26 July 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467317
20 July 2000
Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444384
30 May 2000
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1433660
29 July 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1381642
14 April 1999
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1125723
14 January 1999
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 810034
26 December 1998
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 807418
6 August 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1131254
10 July 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 157720
7 May 1998
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411676
24 July 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 780774
28 August 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1247362
10 June 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1188924
31 October 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878790
3 August 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882391
28 October 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173626
10 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868739
22 June 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961947
16 June 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961944
15 May 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 60917
29 July 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833697
12 July 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 57669
30 October 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256039
18 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265387
28 July 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264880
3 June 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943124
15 July 1991
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243706
8 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243890
13 June 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1237831
24 April 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913468
13 July 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202547
19 April 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200290
5 July 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210017
19 April 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341693
6 October 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321150
23 June 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317409
24 June 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 988740
19 June 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998090
21 May 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300180
10 April 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999423
17 July 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 984933
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2021
Resolved
Place flashlight at or near engine compartment. 46CFR183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 24 May 2021
Resolution: Verified with vessel rep. that an additional flashlight was placed on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 May 2021
Resolved
Vessel needs to update nav pubs. 46CFR184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2021
Resolved 24 May 2021
Resolution: Verified with vessel rep. that updated pubs are on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2017
Resolved
First aid kit has expired and missing items. Replace kit or items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 17 July 2017
Resolution: Verified kit was replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 11 July 2017
Resolved
Excess ring life buoy is degraded and unserviceable. Replace ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 17 July 2017
Resolution: Verified life ring replaced.
Engineering › Electric Propulsion System › Battery Charging Circuitry
Issued 14 May 2012
Resolved
Install machinery guards covering rotation belts of alternators and sea power generators on both main engines and service generator.
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 7 June 2013
Resolution: Guards were installed
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 May 2012
Resolved
Label location of life jackets in passenger compartment stowed under center bench identifying location and number of.
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 7 June 2013
Resolution: Completed
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 27 May 2011
Resolved
Owner/Operator upgrading lifesaving appliances with a 50 and 25 person IBAs. IBAs were not on board yet. Issued requirement to properly install to satisfaction of MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2011
Resolved 8 June 2011
Resolution: Observed IBAs properly installed on top of pilot house. Entered SNs/data into MISLE.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 27 May 2011
Resolved
Ladder to lower cabin (former berthing area) is open to the main cabin and a hazard to passengers in the main cabin because of the potential for falling down the ladder during vessel movement. Issued requirement to install a gate or guard at the top of the ladder.
Due 27 June 2011
Resolved 14 May 2012
Resolution: installed a folding style gate which prevents passengers from going into lower compartment.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 May 2011
Resolved
Lifejackets stowed in lower cabin (former berthing area) need to be relocated to main cabin since the lower cabin will be inaccessible to passengers. Total on board count limited to 60 until corrected.
Condition: Improper Installation
Due 27 June 2011
Resolved 8 June 2011
Resolution: Lifejackets stowed in additional space provided in main cabin.
Communications › Public Address System › Loudspeaker
Issued 27 May 2011
Resolved
Public Address speaker is located in the lower cabin (former berthing area) which will be inaccessible to passengers. During the PA test it was difficult to hear in the main cabin while the engines were running. Issued requirement to relocate the speaker to the main cabin or install an additional speaker in the main cabin.
Action required: 705 - Other - as specified
Due 14 June 2012
Resolved 7 June 2013
Resolution: Moved speaker
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 27 May 2011
Resolved
Install covers for open circuit breaker slots in distribuation panels...all locations.
Due 27 June 2011
Resolved 14 May 2012
Resolution: Installed covers in blank breaker slots, no open breakers remain.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 September 2007
Resolved
Provide service report for all portable fire extinguishers to Coast Guard prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2007
Resolution: Provided service report for all portable fire extinguishers to Coast Guard prior to carrying passengers.
Communications › Radio Communications › EPIRB
Issued 27 September 2007
Resolved
Provide new hydrostatic release mechanism for EPIRB, vessel is restricted to not more than three miles from shore until completed.
Due 10 October 2007
Resolved 24 October 2007
Resolution: Provided new hydrostatic release mechanism for EPIRB
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 September 2007
Resolved
Mount portable fire extinguisher in engine room with permanent bracket.
Due 10 October 2007
Resolved 24 October 2007
Resolution: Properly mounted portable fire extinguisher in engine room with permanent bracket.
Lifesaving › Lifefloat › Lifeline
Issued 27 September 2007
Resolved
Replace all worn lifelines on life float arrangement. Secure paddles to each life float and ensure that vessel name is stenciled on each paddle. Ensure that life float arrangement remains clear of garbage and debris.
Due 10 October 2007
Resolved 24 October 2007
Resolution: Replaced all worn lifelines on life float arrangement. Secured paddles to each life float and ensured that vessel name is stenciled on each paddle. Ensured that life float arrangement remains clear of garbage and debris.
Communications › Alarms/Indicators › High Water Alarm
Issued 27 September 2007
Resolved
Re-label bilge high water alarm on bridge.
Due 5 October 2007
Resolved 24 October 2007
Resolution: Re-labeled bilge high water alarm on bridge.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 September 2007
Resolved
Provide emergency broadcast placard at operating station.
Due 5 October 2007
Resolved 24 October 2007
Resolution: Provided emergency broadcast placard at operating station.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 27 September 2007
Resolved
Clear all bildges of excess oily/water mixtures and ensure the operability of all bildge suctions prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2007
Resolved 24 October 2007
Resolution: Cleared all bildges of excess oily/water mixtures and ensure the operability of all bildge suctions prior to carrying passengers.
Engineering › Bilge Water Management System › Manifold
Issued 27 September 2007
Resolved
Label bilge manifold in engine room, to ensure that operator can identify correct valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2007
Resolution: Labeled bilge manifold in engine room, to ensure that operator can identify correct valve.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2007
Resolved
Provide cover for flouresenant light in berthing area.
Due 10 October 2007
Resolved 24 October 2007
Resolution: Provided cover for flouresenant light in berthing area.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 September 2007
Resolved
Provide proof of enrollment in drug consortium for master and crew prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2007
Resolution: Provided proof of enrollment in drug consortium for master and crew to Coast Guard.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 September 2007
Resolved
Provide onboard vessel all applicable navigation publications and charts for operating area.
Due 10 October 2007
Resolved 24 October 2007
Resolution: Provided onboard vessel all applicable navigation publications and charts for operating area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2006
Resolved
Remove dead end wires in pilot house and in forward anchor space.
Due 30 September 2006
Resolved 30 September 2006
Resolution: Removed all dead end wires.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 September 2006
Resolved
Properly mount Portable fire extinguishers in pilot house.
Due 22 September 2006
Resolved 22 September 2006
Resolution: Properly mounted portable fire extinguishers in pilot house.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 September 2006
Resolved
Provide audible alarm for bunk room bilge alarm prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2006
Resolution: Installed new bilge alarm in bunkroom, so that it met requirements for audible and visual alarms.
Lifesaving › Lifefloat › Lifeline
Issued 14 September 2006
Resolved
Replace all worn lifefloat lines prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2006
Resolution: Replaced all worn lifefloat lines.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 September 2006
Resolved
Replace all lines and straps on lifering prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2006
Resolution: Replaced all lines and straps on lifering.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 14 September 2006
Resolved
Provide two lifejacket lights for lifejackets.
Due 22 September 2006
Resolved 22 September 2006
Resolution: Provided two new lifejacket lights for lifejackets.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 14 September 2006
Resolved
Provide emergency broadcast placard in pilot house.
Due 22 September 2006
Resolved 22 September 2006
Resolution: Provided proper emergency broadcast placard in pilot house.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 September 2006
Resolved
Replace covers for lights in both heads, and for main light in bunk room.
Due 30 September 2006
Resolved 30 September 2006
Resolution: Replaced covers for lights in both heads, and for main light in bunk room.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 September 2006
Resolved
Replace bulbs in two smaller lights in bunk room.
Due 30 September 2006
Resolved 30 September 2006
Resolution: Replaced bulbs in the two smaller lights in bunk room.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2006
Resolved
Provide new eyewash and asprin for first aid kit.
Due 22 September 2006
Resolved 22 September 2006
Resolution: Provided new eyewash and asprin for first aid kit.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 September 2006
Resolved
Replace raw water hose on starboard main engine.
Due 1 October 2006
Resolved 30 September 2006
Resolution: Replaced raw water hose on starboard main engine with new hose.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 September 2006
Resolved
Tighten starboard shaft packing on starboard main.
Due 1 October 2006
Resolved 30 September 2006
Resolution: Tightened starboard shaft packing on starboard main.
Engineering › Bilge Water Management System › Manifold
Issued 14 September 2006
Resolved
Label bildge manifold.
Due 1 October 2006
Resolved 30 September 2006
Resolution: Labeled bilge manifold as directed.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 14 September 2006
Resolved
Label emergency fuel shutoffs.
Due 1 October 2006
Resolved 30 September 2006
Resolution: Labeled emergency fuel shutoffs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 July 2005
Resolved
J-box cover missing
Condition: Improper Installation
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement atesting to completion.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 11 July 2005
Resolved
B1 Fire Extinguiser was not serviced
Condition: Improper/Lack of Maintenance
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Documentation › Logs/Records › Drug Test Records
Issued 11 July 2005
Resolved
Provide additional information on Drug Program.
Condition: Improper/Lack of Maintenance
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 July 2005
Resolved
Replace 4 lifejackets that failed inspection, passenger count reduce until in compliance.
Condition: Unknown
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 11 July 2005
Resolved
Properly attach float light to ring buoy
Condition: Improper Installation
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Lifesaving › Lifefloat › Float-free Link
Issued 11 July 2005
Resolved
Provide lable for detachable link as proof of proper installation
Condition: Improper Installation
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 July 2005
Resolved
Repare leaking hot water heater water hose
Condition: Placed in Improper Service
Due 26 July 2005
Resolved 29 July 2005
Fire Fighting › Fire Bucket › Availability
Issued 11 July 2005
Resolved
Provide 3 fire buckets
Condition: Unknown
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Engineering › Bilge Water Management System › Valve
Issued 11 July 2005
Resolved
Prove proper operation of bilge overboard valve.
Condition: Improper/Lack of Maintenance
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 July 2005
Resolved
Provide original license (to be carried onboard) at all times of operation
Condition: Unknown
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 July 2005
Resolved
Provide light list, nav rules for vessel
Condition: Improper Installation
Due 26 July 2005
Resolved 29 July 2005
Resolution: Faxed statement attesting to completion.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 October 2004
Resolved
Provide 2 adult lifejackets with lights, vessel restricted to 33 passengers oceans/68 passengers limited coastwise until corrected.
Action required: 705 - Other - as specified
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Documentation › Markings/Placards › Warning Signs
Issued 20 October 2004
Resolved
Provide emergency broadcast placard.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2004
Resolved
Provide aspirin, eyewash, ammonia inhalants.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 October 2004
Resolved
Log all drills and EPIRB checks.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Lifesaving › Lifefloat › Paddle
Issued 20 October 2004
Resolved
Re-stencil lifefloat paddles.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 20 October 2004
Resolved
Tighten port shaft packing.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 October 2004
Resolved
Remove oily water in engineroom bilge.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Engineering › Bilge Water Management System › Manifold
Issued 20 October 2004
Resolved
Label bilge manifold.
Due 31 December 2004
Resolved 20 December 2004
Resolution: Rcvd faxed ltr fm O/O stating that all outstanding CG-835 requirements had been completed.
Electrical › Electric Generation Source (service)
Issued 22 November 2002
Resolved
No cycle gauge for S/S generator. Repair/renew LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 January 2003
Resolved 6 May 2003
Operations/Management › Drills/Instruction
Issued 22 November 2002
Resolved
No record of training, testing EPIRB, FCC Radio Log. Conduct required drills and provide appropriate logs with proper entries. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 6 May 2003
Communications › Radio Communications
Issued 22 November 2002
Resolved
Battery expired, hydro out dated. Repair/renew, vsl restricted to less than 3 miles. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2003
Resolved 6 May 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 November 2002
Resolved
Service all fire ext. on board prior to carrying passengers. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2003
Resolved 6 May 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 November 2002
Resolved
No first AID kit. Provide kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2003
Resolved 6 May 2003
Lifesaving › Buoyant Apparatus
Issued 22 November 2002
Resolved
Life float lights not attached, painter, paddle, and life lines rotten. Repair/renew prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 6 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 22 November 2002
Resolved
Batteries expired on PFD's lights, water lights batteries expired. Repair/renew. Vsl retsricted to limited coastwise. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 6 May 2003
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 June 2002
Resolved
E/R 4TH FRAME INBOARD STBD SIDE DECK LONG. FRACTURED. REPAIR/RENEW.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 27 June 2002
Construction/Loadline › Hull › Bracket
Issued 13 June 2002
Resolved
2ND COMPARTMENT 3RD GUSSET PORT & STARBOARD SIDE FRACTURED. DRILL STOP AND WELD.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2002
Resolved 25 July 2002
Documentation
Issued 26 July 2001
Resolved
PROVIDE A WRITTEN WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Documentation
Issued 26 July 2001
Resolved
PROVIDE CREW TRAINING RECORDS.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Fire Fighting
Issued 26 July 2001
Resolved
PROVIDE AN UP TO DATE BI FIRE EXTINGUISHER FOR THE PILOT HOUSE PRIOR TO SAILING.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Construction/Loadline
Issued 26 July 2001
Resolved
REPAIR AUDIBLE ALARM FOR BILGE HIGH WATER INDICATOR.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Lifesaving
Issued 26 July 2001
Resolved
REPLACE HYDROSTATIC RELEASE FOR EPIRB OR SHOW PROOF OF PURCHACE DATE.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Lifesaving
Issued 26 July 2001
Resolved
PROVIDE NEW RETROREFLECTIVE TAPE FOR LIFE FLOATS.
Condition: Unknown
Due 6 August 2001
Resolved 6 August 2001
Lifesaving
Issued 20 July 2000
Resolved
PROVIDE A PORTABLE WATERTIGHT CONTAINER, PROPERLY LABELED, FOR DISTRESS SIGNALS.
Condition: Unknown
Due 4 August 2000
Resolved 1 August 2000
Lifesaving
Issued 20 July 2000
Resolved
PROPERLY MOUNT WATERLIGHTS FOR L/Fs.
Condition: Unknown
Due 4 August 2000
Resolved 1 August 2000
Lifesaving
Issued 29 July 1999
Resolved
RENEW HYDROSTATIC RELEASE SERVING EPIRB. VESSELS ROUTE REDUCED TO L, B, S,AND R UNTIL CLEARED.
Condition: Unknown
Due 30 July 1999
Resolved 29 July 1999
Fire Fighting
Issued 29 July 1999
Resolved
RENEW THE B-I EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 30 July 1999
Resolved 29 July 1999
Electrical
Issued 6 August 1998
Resolved
LABEL ALL BREAKERS THROUGHOUT VESSEL.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Fire Fighting
Issued 6 August 1998
Resolved
SERVICE EXPIRED B-II ENTINGUISHER OR PROVIDE ONE NEW B-II FIRE EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 10 August 1998
Resolved 6 August 1998
Unknown
Issued 6 August 1998
Resolved
PROVIDE PROOF OF LOGGED TRAINING AND DRILLS.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Construction/Loadline
Issued 6 August 1998
Resolved
REWELD CRACKED WELDS IN #2 COMPT AT FRAMES 1, 2, 3 ON BOTH PORT AND STBD SIDES. ADDRESS AT FALL HAUL OUT.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Lifesaving
Issued 6 August 1998
Resolved
ATTACH FLOATING WATERLIGHT TO RINGBUOY W/ 3' TO 6' LANYARD W/ QUICK DISCONNECT CLIP.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 6 August 1998
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Unknown
Issued 6 August 1998
Resolved
PROVIDE PROOF OF LOGGED EPIRB TESTS.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Unknown
Issued 6 August 1998
Resolved
PROVIDE GARBAGE LOG.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 24 July 1997
Resolved
SHOW PROOF OF LOGGED TRAINING, DRILLS AND MONTHLY EPIRB TESTS.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Unknown
Issued 24 July 1997
Resolved
PROVE 100% COMPLIANCE W/ CG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 3 August 1997
Resolved 6 August 1997
Lifesaving
Issued 24 July 1997
Resolved
PROVIDE 3 ADULT PFD'S. VESSELS TOTAL CARRYING CAPACITY REDUCED TO 67 ADULTS AND 7 CHILDREN UNTIL CLEARED.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Lifesaving
Issued 24 July 1997
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD NEXT TO RADIO TRANSMIT EQUIPMENT.
Condition: Unknown
Due 3 August 1997
Resolved 6 August 1997
Lifesaving
Issued 24 July 1997
Resolved
PROVIDE AND POST LIFE JACKET PLACARD.
Condition: Unknown
Due 3 August 1997
Resolved 6 August 1997
Fire Fighting
Issued 24 July 1997
Resolved
PROVIDE 1 B-1 AND 1 B-II FIRE EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 3 August 1997
Resolved 6 August 1997
Lifesaving
Issued 24 July 1997
Resolved
INSTALL RETRO TAPE IN 4 EVENLY SPACED PLACES ON RING BUOY AND LIFE FLOATS.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 24 July 1997
Resolved
LABEL ALL FUEL SHUT OFFS.
Condition: Unknown
Due 3 August 1997
Resolved 20 August 1997
Documentation
Issued 22 June 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 June 1994
Resolved 22 June 1994
Electrical
Issued 22 June 1994
Resolved
PROVIDE PROPER BLANKS FOR ELECTRICAL PANEL IN PILOT HOUSE, STBD SIDE UNDER CHART TABLE.
Condition: Unknown
Due 22 June 1994
Resolved 22 June 1994
Lifesaving
Issued 29 July 1993
Resolved
VESSEL TOTAL PERSONS REDUCED TO 30 PERSONS ON AN OCEANS ROUTE. REPLACE LIGHTS ON 5 PFD'S. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR OF COGNIZANT [name withheld] 30AUG93.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Navigation
Issued 28 July 1992
Resolved
OBTAIN UP TO DATE NAVIGATION RULES.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Navigation
Issued 28 July 1992
Resolved
OBTAIN UP TO DATE LIGHT LIST.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Lifesaving
Issued 28 July 1992
Resolved
PROVIDE 1 HAND BILGE PUMP.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Navigation
Issued 28 July 1992
Resolved
OBTAIN UPDATED CHARTS FOR AREA OF OPERATION INCLUDING GULF OF MEXICO AND FLORIDA AS SPECIFIED BY ROUTE.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Engineering
Issued 28 July 1992
Resolved
REPAIR / REPLACE LAGGING ON EXHAUST PIPING EXTENDING FROM BOTH MDE.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Navigation
Issued 28 July 1992
Resolved
OBTAIN UP TO DATE COAST PILOT.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Engineering
Issued 28 July 1992
Resolved
LABEL FUEL SHUTOFF.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Electrical
Issued 28 July 1992
Resolved
IN LAZARETTE-SECURE BATTERIES IN BATTERY BOX AND PROPERLY SECURE COVER.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Electrical
Issued 28 July 1992
Resolved
IN ENGINEROOM-REMOVE BATTERIES FROM BOX, CLEAN BATTERIES AND BOX OF CORROSION. INSURE BOX IS PROPERLY LINED WITH FIBERGLASS OR LEAD. PROVIDE SECURE PROTECTION OVER BATTERY TERMINALS. THIS IS APPLICABLE TO BATTERIES ON BOTH PORT & STBD SIDES.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Navigation
Issued 28 July 1992
Resolved
OBTAIN UP TO DATE TIDES & CURRENT TABLES.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Lifesaving
Issued 28 July 1992
Resolved
OBTAIN 2 RING BUOYS VSL LIMITED TO CARRY 70 TOTAL PERSONS UNTIL THESE RING BUOYS ARE PROVIDED.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Documentation
Issued 28 July 1992
Resolved
OBTAIN MARPOL WASTE MANAGEMENT PLACARD.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Engineering
Issued 28 July 1992
Resolved
PLACE GUARD AROUND BELT DRIVE ON STBD MDE.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Lifesaving
Issued 28 July 1992
Resolved
CLEAN BILGES OF EXCESS OIL AND ANY STRAY UNNECESSARY OBJECTS.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Lifesaving
Issued 15 July 1991
Resolved
PROVIDE (3) RED FLARES AND (3) ORANGE SMOKE FLARES.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Lifesaving
Issued 15 July 1991
Resolved
PROVIDE PROPER EPIRB MOUNT IN ORDER THAT THE EPIRB CAN FLOAT FREE OF VESSEL.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Lifesaving
Issued 15 July 1991
Resolved
PROVIDE AND INSTALL UP TO DATE PFD LIGHTS ON ALL PFDS.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Fire Fighting
Issued 15 July 1991
Resolved
PROVIDE (1) TYPE B, SIZE II (BII) PORTABLE FIRE EXTINGUSHER.
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Navigation
Issued 15 July 1991
Resolved
PROVIDE UP TO DATE TIDE TABLES, CURRENT TABLES, LOCAL NOTICE TO MARINERS RULES OF THE ROAD (NAV. RULES).
Condition: Unknown
Due 25 September 1991
Resolved 25 September 1991
Fire Fighting
Issued 6 October 1987
Resolved
PROVIDE PROPER MAIN DECK FITTING FOR FIRE MAIN PIPING.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
PROPERLY SECURE WIRING IN ENGINEROOM FOR 12 VOLT BILGE PUMP.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
PROPERLY SECURE HORIZONTAL RUNS OF WIRING IN LAZARETTE WITH METAL WIRE HOLDERS.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
PROVIDE PROPER ELECTRICAL BOX COVERS MISSING FROM: 2 - BERTHING COMPART- MENT; 1 - PASSENGER COMPARTMENT; 1 - ENGINEROOM; 1 - LAZARETTE.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
SHORTEN AND SECURE BATTERY CABLES FOR GENERATOR BATTERY AND PROVIDE COVER FOR BATTERY, LOCATED IN LAZARETTE.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Lifesaving
Issued 6 October 1987
Resolved
PROVIDE TWO COAST GUARD APPROVED WATERLIGHTS FOR RING BUOYS.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Construction/Loadline
Issued 23 June 1987
Resolved
RENEW PLASTIC THROUGH HULL FITTINGS FOR BILGE PUMP DISCHARGES WITH METAL FITTINGS.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Engineering
Issued 19 June 1986
Resolved
STENCIL REMOTE FUEL TANK SHUT OFF VALVE LOCATIONS FOR CLEAR IDENTIFICATION AND LOCATION
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Electrical
Issued 19 June 1986
Resolved
PROVIDE PROTECTIVE BLANK COVERS FOR PILOTHOUSE ELECTRICAL PANELS.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Lifesaving
Issued 19 June 1986
Resolved
PROVIDE TWO COAST GUARD APPROVED WATER LIGHTS FOR TYPE V RING BUOYS.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Electrical
Issued 19 June 1986
Resolved
SECURELY MOUNT ENGINE AND GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Electrical
Issued 19 June 1986
Resolved
PROVIDE PROTECTIVE GLOBES AND GUARDS FOR ENGINEROOM AND GENERATOR ROOM LIGHTING SYSTEM.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Lifesaving
Issued 19 June 1986
Resolved
STENCIL ADULT AND CHILDRENS PFD STOWAGE AREAS.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Electrical
Issued 17 July 1985
Resolved
TEST AND OBTAIN USCG INSPECTION OF GENERATOR INSTALLATION PRIOR TO USE.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Accommodation/Occupational Safety
Issued 17 July 1985
Resolved
PROVIDE ADEQUATE BERTHING FOR CREW.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Fire Fighting
Issued 17 July 1985
Resolved
MOUNT FIRE EXTINGUISHERS ON BRACKETS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Accommodation/Occupational Safety
Issued 17 July 1985
Resolved
OBTAIN USCG INSPECTION OF PASSENGER ACCOMODATION SPACE BELOW DECKS PRIOR TOALLOWING PASSENGERS IN COMPARTMENT.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985