MAURY USCG vessel records Sign in
← All vessels

M/V OUTER LIMITS

M/V OUTER LIMITS is a 1985 passenger vessel (inspected). The Coast Guard has recorded 106 inspections since 1985, most recently in July 2026, along with 113 deficiencies and 2 casualty investigations between 2003 and 2014.

Records from 1985 to 2026. Most recent: inspection, 13 July 2026.

Built
1985
Last inspected
13 July 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ6405
254425
Flag
UNITED STATES
367169560
Maury page id
psix-254425

Inspections, by type

…with no type recorded16
Years with a record 36 calendar years (1985–2026)
The 106 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.2 ft × 19.4 ft × 7.0 ft
Registered tonnagegross 67 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6405MMSI 367169560 · active · compulsorily equipped · granted 29 June 2017, expires 29 June 2027
WCX4854MMSI 367169560 · terminated · compulsorily equipped · granted 1 March 2007, cancelled 13 June 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 106

13 July 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8437423
14 April 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111315
8 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111291
25 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7942369
15 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7715684
15 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7716164
15 June 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7804134
11 April 2023 In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7666828
13 May 2021 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7195896
1 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7166863
15 April 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6938056
1 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6828575
20 May 2019 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6688468
19 March 2019 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6645429
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548026
8 May 2018 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6409038
17 May 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6148368
21 March 2017 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6108841
17 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5879428
1 April 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5845419
4 October 2014 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4998766
4 October 2014 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4999996
8 June 2014 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4882772
7 March 2014 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4819037
30 March 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3442918
15 August 2008 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3299228
21 April 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3189628
10 April 2008 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3181368
27 April 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2904666
14 March 2007 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2887946
10 October 2006 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2797498
10 May 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2619315
3 May 2006 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2684875
6 January 2006 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2560459
16 May 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2345938
7 April 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2324865
12 April 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2033321
9 April 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2026151
19 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2027747
7 September 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1901007
12 May 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1791646
5 May 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1613124
9 April 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601682
22 February 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1488512
15 August 2001 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1069031
17 April 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1061645
20 March 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370063
1 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1457877
30 May 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 817765
15 May 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391294
28 February 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1470248
24 May 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386535
3 September 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 798639
28 August 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 797386
4 May 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1468860
25 February 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381147
21 November 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396831
21 July 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1116063
16 May 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1380884
14 April 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1464682
23 September 1996 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1400421
27 November 1995 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402137
18 July 1995 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1460797
3 March 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 854533
20 January 1995 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1180319
3 January 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1166673
12 December 1994 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1389934
28 January 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 852667
7 December 1993 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414210
12 September 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 34398
25 May 1993 Inclining Experiment
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1419137
3 August 1992 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1256674
30 July 1992 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 697143
28 June 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 960557
25 June 1992 Deficiency Check · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 961813
26 May 1992 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 43719
13 April 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 958021
30 December 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 664281
24 September 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 935800
23 January 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1224552
27 November 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 926445
23 October 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1230354
17 November 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 925305
15 November 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213316
30 October 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 889766
19 July 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897152
24 April 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037576
30 November 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 895898
22 September 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1198590
11 August 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037724
22 June 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 894175
20 April 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1344130
29 March 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 993625
16 February 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022273
23 June 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1317769
5 May 1987 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024056
6 March 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1315698
4 March 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007811
17 December 1986 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1027922
3 October 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1318220
31 January 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996766
31 October 1985 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297801
7 October 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 993752
19 September 1985 Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 986956
12 September 1985 Initial Construction-Excluding Oversight
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296110
5 September 1985 Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989339

Deficiency record · 113

05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 April 2025 Resolved
Vessel's VHF radio did not have MMSI logged and GPS was not set-up; thereby DSC function was operational. Vessel is to replace radio or have these applications functioning on current system, prior to operating more than 20NM 46CFR184.502
Action required: 705 - Other - as specified
Resolved 28 April 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2025 Resolved
The forward bulkhead of E/R had an open penetration on the upper/starboard side. Fill the penetration to the satisfaction of the attending Coast Guard Marine Inspector. To be rectified by 28 April 2025. 46 CFR 179.320(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2025
Resolution: Hole was filled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2025 Resolved
Distribution panel #3 was missing a blank. Install a blank or spare breaker in the open slot of distribution panel #3. 46 CFR 183.330.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2025
Resolution: Blank was installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here. Marine inspector found the portable fire extinguishers had not been serviced. Have them serviced and reach out to the local OCMI once completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2024
Resolution: Received servicing report from Master.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 June 2024 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2024
Resolution: Received servicing report from Master.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2020 Resolved
A required portable fire extinguisher was identified as being under charged. Have the fire extinguisher serviced by a certified servicing company.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 April 2020 Resolved
Provide proof of enrollment and crew list for drug testing consortium.
Action required: 10 - Deficiency Rectified
Due 29 April 2020
Resolved 4 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019 Resolved
Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 10 April 2020
Resolution: drawings submitted for file
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 1 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 October 2019 Resolved
Vessel required to have the appropriate number of smoke detectors in accommodation spaces. Must install smoke detector in forward four man berthing to satisfaction of Coast Guard Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 28 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 October 2019 Resolved
All emergency lighting installed shall operate in accordance with regulations. Must modify emergency power on DC to activate upon failure of main power to vessel
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2019
Resolved 28 October 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 October 2019 Resolved
All emergency exits must be properly labeled in accordance with regulations. Forward emergency exit must be labeled on the outside to the satisfaction of the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 5 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
CLSN: Vsl is broadcasting Invalid Call Sign, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2018
Resolution: Verified in VIVS.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 4 October 2014 Resolved
Provide proper operation of fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2014
Resolution: Vessel o/o & Captain worked with Simplex Grinnell to refill discharged bottle with Halon 1301.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 June 2014 Resolved
Properly re-locate the two (2) pressure control switches for the fixed fire fighting system located in the engine and provide a technician's service report.
Action required: 705 - Other - as specified
Due 8 September 2014
Resolved 11 July 2014
Resolution: Pressure switches were properly re-located.
Engineering › Fuel Oil Service System › Valve
Issued 27 April 2007 Resolved
Repair/replace emergency fuel valve handle on the starboard side, handle hits wood and will not secure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2007
Resolution: Both emergency fuel valve handles were renewed
Fire Fighting › Grease Extraction Hood › General
Issued 27 April 2007 Resolved
Provide data for hood and grill
Action required: 705 - Other - as specified
Resolved 3 May 2007
Resolution: Data was provided and vsl complies with CID policy letter #20
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 27 April 2007 Resolved
Make both over boards for toilets lockable
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 3 May 2007
Resolution: Both overboards were locked
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 April 2007 Resolved
Repair valve for remote valve, handle is hitting the wood and not allowing to close completely.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2007
Resolution: Emergency fuel remote valve handle was replaced.
Fire Fighting › Ventilation Systems › Fans
Issued 27 April 2007 Resolved
Starboard side vent closure for the engine is inop.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2007
Resolution: Closure hinges was repaired, closure now is working properly.
Lifesaving › Lifefloat › Serviceable
Issued 10 May 2006 Resolved
Replace four lines to each strobe lights.
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 16 May 2006
Resolution: Replaced four lines to each strobe lights.
Lifesaving › Lifejacket/PFD (Type II) › Lights
Issued 10 May 2006 Resolved
Replace/repair 2 inop lights on lifejackets.
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 16 May 2006
Resolution: Lights are renewed
Lifesaving › Lifefloat › Serviceable
Issued 10 May 2006 Resolved
Repair cracks and small holes on two life floats.
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 16 May 2006
Resolution: Cracks and holes are repaired.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 May 2006 Resolved
Update to current US Coast Pilot.
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 16 May 2006
Resolution: Current US Coast Pilot have been purschased and onboard
Personnel › Certificates/Documents/Licenses › License, Master
Issued 10 May 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 16 May 2006
Resolved 16 May 2006
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2006 Resolved
Replace outdated Aspirin.
Due 16 May 2006
Resolved 16 May 2006
Resolution: Aspirin has been replaced
Fire Fighting › Fixed Fire Detection System
Issued 5 May 2002 Resolved
Provide servicing report for fixed and portable fire extinguishers and show proper operation of engine/generator shutdowns.
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 6 May 2002
Construction/Loadline › Penetrations
Issued 5 May 2002 Resolved
Seal bulkhead fwd engine room lower pipe penetration and remove excess water from bilges. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 6 May 2002
Construction/Loadline
Issued 1 February 2001 Resolved
Provide metalic valves and penetrationsfor PVC piping traversing watertightbulkheads.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 February 2002
Resolved 21 February 2002
Lifesaving
Issued 1 February 2001 Resolved
Provide damage control kit consisting of a mallet, various cone plugs and okum in a labeled container/bag. Kit is to be stored in an accessable area above the bulkhead deck.
Condition: Unknown
Due 1 February 2001
Resolved 9 February 2001
Lifesaving
Issued 15 May 2000 Resolved
Renew eye wash in frist aid kit._x001C_
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Lifesaving
Issued 15 May 2000 Resolved
Post emergency broadcast placard._x001C_
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Fire Fighting
Issued 15 May 2000 Resolved
Repair all vent closures to seal upon closing._x001C_
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Construction/Loadline
Issued 28 February 2000 Resolved
Demonstrate proper operation of bilge piping system with duct putty removed.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Construction/Loadline
Issued 28 February 2000 Resolved
Install high level bilge alarm in bunk-room space.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Fire Fighting
Issued 24 May 1999 Resolved
INSTALL AUTOMATIC HEAT DETECTION FOR FIXED HALON SYSTEM.
Condition: Unknown
Due 16 June 1999
Resolved 24 June 1999
Fire Fighting
Issued 24 May 1999 Resolved
PROVIDE 1 ADDITIONAL B-II FIRE EXTINGUISHER FOR GALLEY.
Condition: Unknown
Due 25 May 1999
Resolved 24 June 1999
Fire Fighting
Issued 4 May 1998 Resolved
PROVIDE TIME DELAY AND ALARM TO SOUND FOR AT LEAST 20 SECONDS FOR FIXED FIRE FIGHTING SYSTEM. PROVE OPERATION TO ATTENDING MARINE INSPECTOR. (46 CFR 181.410(B)
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 4 May 1998 Resolved
LABEL RING BUOY AND LIGHT WITH VESSEL NAME.
Condition: Unknown
Due 12 May 1998
Resolved 22 June 1998
Fire Fighting
Issued 4 May 1998 Resolved
TEST FIXED FIREFIGHTING SYSTEM IN THE PRESENCE OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 16 May 1997 Resolved
Modify and renew the current fixed Halon system in E/R to meet requirementsand have serviced._x001C_
Condition: Unknown
Due 21 July 1997
Resolved 29 May 1997
Electrical
Issued 16 May 1997 Resolved
Renew salt water cooling (suction) lline on generaqtor._x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Fire Fighting
Issued 16 May 1997 Resolved
Make repairs and test berthing area sprinkler system._x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Construction/Loadline
Issued 16 May 1997 Resolved
Cap off 2" pipe run from E/R to aft steering._x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Lifesaving
Issued 16 May 1997 Resolved
Log all training and lifesaving repairs._x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Lifesaving
Issued 16 May 1997 Resolved
Renew life ring and line._x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Construction/Loadline
Issued 16 May 1997 Resolved
Provide hand pump with proper length hoses._x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Electrical
Issued 14 April 1997 Resolved
PROVIDE DRIPPROOF ELECTRICAL RECEPTACLES IN THE ENGINE ROOM COMPARTMENT.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 14 April 1997 Resolved
PROVIDE A PROPER BOX AND COVER FOR THE FORWARD BATTERY IN BATTERY BANK #2.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Engineering
Issued 14 April 1997 Resolved
REPLACE THE WORN STARBOARD CUTLASS BEARING.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 12 December 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPAIR LIFE RING WITH PROTECTIVE COATING OR REPLACE.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Documentation
Issued 12 December 1994 Resolved
PROVIDE PROOF OF CURRENT FCC OPERATORS LICENSE, SEND COPY TO MARINE INSPECTOR.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Lifesaving
Issued 12 December 1994 Resolved
PROVIDE USCG APPROVED PFD LIGHTS FOR 35 PFDS, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Fire Fighting
Issued 12 December 1994 Resolved
PROPERLY SERVICE (ANNUAL) FOR B-I EXTINGUISHER ON BRIDGE, PRIOR TO CARRYINGPASSENGERS FOR HIRE.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Engineering
Issued 25 June 1992 Resolved
Prove proper operation of the main engine guages in the pilothouse.
Condition: Unknown
Due 24 October 1992
Resolved 4 August 1992
Accommodation/Occupational Safety
Issued 24 September 1991 Resolved
REPAIR TOILETS TO ENSURE THAT THEY ARE NOT CONTINUOUS FLOW AND/OR PROVIDE AN APPROVED TYPE II SYSTEM.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Engineering
Issued 24 September 1991 Resolved
DOUBLE CLAMP ALL FLEXIBLE HOSES ON SEA SUCTION LINES IN ENGINE ROOM.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Lifesaving
Issued 24 September 1991 Resolved
PROVIDE APPROVED WATER LIGHTS FOR FIVE ADULT PFD'S. VESSEL IS LIMITED TO CARRYING 32 PERSONS UNTIL COMPLETION OF THIS ITEM.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Engineering
Issued 24 September 1991 Resolved
PROVE PROPER OPERATION OF MAIN ENGINE GAUGES IN PILOTHOUSE.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Fire Fighting
Issued 24 September 1991 Resolved
SERVICE FIXED HALON SYSTEM LOCATED IN ENGINEROOM.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Fire Fighting
Issued 24 September 1991 Resolved
SERVICE ALL PORTABLE FIRE FIGHTING EQUIPMENT.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Construction/Loadline
Issued 23 January 1991 Resolved
REPAIRS TO HULL DAMAGE RESULTING FROM GROUNDING TO BE COMPLETED NOT LATER THAN 31 MAR 91.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Engineering
Issued 23 October 1990 Resolved
CAP THE UNUSED THRU HULL FITTINGS IN WAY OF THE FORWARD BULKHEAD OF THE ENGINE COMPARTMENT.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
LABEL THE BILGE MANIFOLD VALVES.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Engineering
Issued 23 October 1990 Resolved
REPAIR THE WATER LEAK IN THE PORT MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Electrical
Issued 23 October 1990 Resolved
REMOVE DEAD-END ELECTRICAL WIRING ALONG THE FORWARD BULKHEAD OF THE ENGINE COMPARTMENT.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Documentation
Issued 23 October 1990 Resolved
PROVIDE A VALID FCC RADIO SAFETY TELEPHONY CERTIFICATE.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Navigation
Issued 30 October 1989 Resolved
PROVIDE FCC CERTIFICATE FOR THE VESSEL'S EPIRB.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Electrical
Issued 30 October 1989 Resolved
PROVIDE GROUNDED RECEPTACLE FOR THE T.V. AND GALLEY EQUIPMENT.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Electrical
Issued 30 October 1989 Resolved
PROVE THE PROPER OPERATION OF THE CG APPROVED EMERGENCY LIGHTING SYSTEM AS PER PLANS DTD 05MAY87 IAW 46 CFR 184.30.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Electrical
Issued 30 October 1989 Resolved
PROVIDE LEAD OR FIBERGLASS LINED BATTERY BOXES FOR ALL BATTERY INSTALLATIONON BOARD THE VESSEL, AND PROVIDE COVER FOR THE STBD BATTERY BOX.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Construction/Loadline
Issued 30 October 1989 Resolved
MAKE THE AFT ENGINE ROOM BULKHEAD WATERTIGHT IN WAY OF THE PIPE PENETRATION.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Electrical
Issued 30 October 1989 Resolved
PROVE THE PROPER OPERATION OF THE S/S DIESEL GENERATOR REMOTE SHUT DOWN ANDENSURE THAT THE GENERATOR IS EQUIPPED WITH A SUITABLE PULLEY GUARD TO PROTECT PERSONNEL FROM ROTATING DANGER.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Documentation
Issued 30 October 1989 Resolved
UPDATE THE OFFICIAL MARINE DOCUMENT TO REFLECT CURRENT OWNER ADDRESS.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Electrical
Issued 24 April 1989 Resolved
DRY BOTH BATTERY BOXES.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Engineering
Issued 24 April 1989 Resolved
REPAIR LEAKS IN FIBERGLASS EXHAUST PIPING AS FOLLOWS: AT RAW WATER HOSE CONNECTION ON STBD EXHAUST, AT AFT FLEXIBLE HOSE CONNECTION AND AT AFT E/R BULKHEAD ON PORT EXHAUST.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Navigation
Issued 24 April 1989 Resolved
PROVIDE DOUBLE NUT FOR STARBOARD QUADRANT ON STEERING ARM.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 24 April 1989 Resolved
REPAIR LEAKS FROM MAINDECK ACCESS HATCHES TO ENGINE ROOM.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Deck/Cargo
Issued 24 April 1989 Resolved
RECONNECT HAWSEPIPE TO PREVENT WATER FROM LEAKING INTO THE FOREPEAK.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Electrical
Issued 24 April 1989 Resolved
PROVIDE COVER FOR ELECTRICAL BOX IN LAZARETTE.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 24 April 1989 Resolved
REPAIR LEAK FROM MAIN DECK IN WAY OF PORT FUEL FILL IN TANK COMPARTMENT OVERHEAD.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 24 April 1989 Resolved
CLEAN ALL GATE VALVES AND VALVE BODIES.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 24 April 1989 Resolved
PROVIDE CAPTURE CHAINS FOR ALL WATERTIGHT HATCHES.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 24 April 1989 Resolved
PROVIDE A SIGN ON WATERTIGHT DOOR TO KEEP DOOR CLOSED WHILE UNDERWAY.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Accommodation/Occupational Safety
Issued 24 April 1989 Resolved
REPAIR/REPLACE FLEXIBLE HOSE CONNECTION FROM MSD TO THROUGH HULL AND REPAIRLEAK FROM AROUND INSPECTION PLATE, BOTH ON STARBOARD MSD.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Electrical
Issued 24 April 1989 Resolved
REMOVE DEAD-END WIRES FROM LAZARETTE, FOREPEAK AND IN WAY OF STBD MDE.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Electrical
Issued 22 September 1988 Resolved
REMOVE TEMPORARY POWER CORD AND PERMANENTLY HARDWIRE SANITATION FLUSH PUMP.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Electrical
Issued 22 September 1988 Resolved
PROPERLY SECURE AND PROVIDE COVER FOR WIRING ASSOCIATED WITH FRESH WATER PUMP.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Fire Fighting
Issued 22 September 1988 Resolved
PROVE PROPER OPERATION OF VENT DAMPERS; LABEL PULL HANDLES.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Construction/Loadline
Issued 22 September 1988 Resolved
PROVE PROPER OPERATION OF POWER-DRIVEN BILGE PUMP AS REQUIRED BY 46 CFR 182.25-10.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Engineering
Issued 16 February 1988 Resolved
REPAIR PORT MAIN ENGINE FUEL OIL SHUT-OFF REMOTE VALVE.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Engineering
Issued 16 February 1988 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Lifesaving
Issued 16 February 1988 Resolved
LABEL WATERTIGHT DOORS, ESCAPE HATHES AND REMOTE FUEL OIL SHUT-OFFS IN ACCORDANCE WITH 46 CFR 185.30.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Documentation
Issued 16 February 1988 Resolved
MAINTAIN VESSEL'S STABILITY LETTER ON BOARD.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Accommodation/Occupational Safety
Issued 16 February 1988 Resolved
PROVE PROPER OPERATION OF REMOTE ENGINEROOM EXHAUST VENT CLOSURES.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Lifesaving
Issued 16 February 1988 Resolved
SEAL HOLE (PORT), REPLACE PAINTERS (BOTH), AND PROPERLY MOUNT LIFE FLOATS.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Accommodation/Occupational Safety
Issued 16 February 1988 Resolved
REPLACE SANITATION SYSTEM SALTWATER PUMP.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Construction/Loadline
Issued 16 February 1988 Resolved
INSTALL PLUG IN UNUSED BAIT TANK SALTWATER SEA VALVE.
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Accommodation/Occupational Safety
Issued 16 February 1988 Resolved
EXTEND ENGINEROOM EXHAUST DUCTING TO NEAREST BILGE OR DECKPLATE OR FLOOR LEVEL IN ACCORDANCE WITH 46 CFR 182.20-45(C).
Condition: Unknown
Due 16 February 1988
Resolved 16 February 1988
Navigation
Issued 4 March 1987 Resolved
SUBMIT WELDING PROCEDURES AND PROOF OF WELDER QUALIFICATIONS, FOR REPAIRS TO VESSEL'S RUDDER.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Deck/Cargo
Issued 4 March 1987 Resolved
SUBMIT PLANS TO U.S. COAST GUARD FOR BAIT TANK PIPING MODIFICATIONS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 4 March 1987 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT IN WAY OF ANCHOR WINDLASS WIRING.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Electrical
Issued 4 March 1987 Resolved
PROPERLY SUPPORT ANCHOR WINDLASS WIRING IN WAY OF COMPARTMENT AFT COLLISIONBULKHEAD.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Accommodation/Occupational Safety
Issued 3 October 1986 Resolved
INSTALL METALLIC OVERBOARD DISCHARGE VALVES FOR BILGE DISCHARGE PORT/STBD AND DRAIN FROM HEAD IN PLASTIC OVERBOARD LINES.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Electrical
Issued 3 October 1986 Resolved
PROVIDE EMERGENCY LIGHTING IN BELOW DECK BERTHING AREAS. IN THE INTERIOR, PLACE PORTABLE LIGHTS IN BERTHING.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Fire Fighting
Issued 3 October 1986 Resolved
OBTAIN AND INSTALL NOZZLE ON FIREHOSE.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Fire Fighting
Issued 3 October 1986 Resolved
SERVICE ALL PORTABLE EXTINGUISHERS AND FIXED ENGINEROOM HALON SYSTEM.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Lifesaving
Issued 3 October 1986 Resolved
REPAIR INTERIOR LIFEFLOAT LIFELINE.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Fire Fighting
Issued 3 October 1986 Resolved
DEMONSTRATE PROPER OPERATION OF BERTHING AREA FIRE PUMP AND AIR TEST BERTHING AREA FIRE DISCHARGE PIPING AND SPRAY NOZZLES.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Construction/Loadline
Issued 19 September 1985 Resolved
PROVIDE REVISED PLANS FOR BAIT TANK APPROVAL BY 30 OCTOBER 1985.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985
Documentation
Issued 19 September 1985 Resolved
POST STABILITY LETTER, PRIOR TO CARRYING PASSANGERS FOR HIRE.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985
Documentation
Issued 19 September 1985 Resolved
POST OPERATOR'S LICENSE WHEN OPERATING UNDER THE ATHORITY OF THE LISCENSE.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985
Fire Fighting
Issued 19 September 1985 Resolved
PRIOR TO CARRYING PASSANGERS FOR HIRE, HAVE FIXED EXTINGUISHING SYSTEM FOR ENGINEROOM AND FUEL TANK COMPARTMENT EXAMINED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 September 1985
Resolved 19 September 1985

Casualty record · 2

7 September 2003Routine · role: Involved in a Marine Casualty · activity 1901007
4 October 2014Routine · role: Involved in a Marine Casualty · activity 4999996
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record