MAURY USCG vessel records Sign in
← All vessels

GULF RANGER

GULF RANGER is a 1985 fishing tender. The Coast Guard has recorded 51 inspections since 1985, most recently in May 2014, along with 20 deficiencies and 1 casualty investigation in 2002.

Records from 1985 to 2014. Most recent: inspection, 28 May 2014.

Built
1985
Last inspected
28 May 2014
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8602309 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDL4134
254480
Flag
UNITED STATES
368128470
Maury page id
psix-254480

Inspections, by type

…with no type recorded12
Years with a record 25 calendar years (1985–2014)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)129.9 ft × 36.0 ft × 9.0 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERVICE MACHINE GROUP,INC · AMELIA, LA, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPETERSBURG, AK
Trade endorsementsFishery, Registry
DocumentationValid · issued 23 March 2026 · expires 31 March 2027
Service, as the file records itFishing Tender
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL4134MMSI 368128470 · active · compulsorily equipped · granted 22 January 2020, expires 22 January 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDG2956MMSI 367520990 · expired · compulsorily equipped · granted 10 March 2012, cancelled 14 May 2022
WDD4789MMSI 367149090 · expired · compulsorily equipped · granted 4 November 2006, cancelled 7 January 2017
WDB7455MMSI 338899000 · cancelled · compulsorily equipped · granted 23 April 2004, cancelled 6 November 2006
WSH9032MMSI 338899000 · cancelled · compulsorily equipped · granted 5 December 1997, cancelled 25 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 51

28 May 2014 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4878081
22 May 2014 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4864319
27 January 2012 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4232133
4 December 2008 Annual Inspection · Hull Examination · Administrative Inspection · MTSA Verification · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3376722
8 August 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3292707
15 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3189991
17 October 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3093243
12 April 2007 Examination of Repairs · Hull Examination · Internal Structural Exam · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2910164
23 October 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806476
16 October 2006 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2838656
17 January 2006 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2566635
3 January 2005 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2268225
3 December 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2252833
21 June 2004 Cargo Tank Internal · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2105597
6 January 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1976069
18 November 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1710999
30 October 2002 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1698433
17 June 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1632168
30 May 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462231
8 October 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054657
5 October 2000 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 11688
5 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 142926
15 September 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369827
1 October 1999 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786255
10 June 1999 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470217
8 May 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 101049
8 May 1999 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798450
6 May 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 53039
9 July 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450177
20 June 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422857
16 August 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380645
28 December 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 656251
27 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 160290
30 June 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357228
9 August 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423981
18 April 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167792
16 November 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414212
30 June 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389669
26 February 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439359
19 June 1992 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373738
4 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938628
23 July 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353177
26 June 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247760
25 June 1990 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918005
12 July 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894622
20 September 1988 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196435
20 September 1988 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349894
7 September 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349734
15 July 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023092
10 July 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292739
17 July 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296447

Deficiency record · 20

Communications › Alarms/Indicators › Bilge Alarm
Issued 28 May 2014 Resolved
In operable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2014
Resolution: Caused by blown fuse. Repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 May 2014 Resolved
All lower/back-up nav lights in-operable
Action required: 17 - Rectify deficiencies prior to departure
Due 28 May 2014
Resolved 28 May 2014
Resolution: Bulbs changed out
Communications › Audible Communications › Horn/Whistle
Issued 28 May 2014 Resolved
Hoen in-operable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2014
Communications › Radio Communications › EPIRB
Issued 28 May 2014 Resolved
Expired battery
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2014
Resolution: Battery replaced sat
Electrical › Electric Supply System (service) › Cable
Issued 28 May 2014 Resolved
Unapproved wire splices on aft operating station
Action required: 705 - Other - as specified
Resolved 29 May 2014
Documentation › Markings/Placards › Garbage Placard
Issued 28 May 2014 Resolved
Update to new MARPOL V placard
Action required: 705 - Other - as specified
Resolved 29 May 2014
Engineering › Bilge Water Management System › Strainer
Issued 28 May 2014 Resolved
Missing strainer on bilge line to Fore peak tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2014
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 May 2014 Resolved
Install blank in distribution panel for missing breaker
Action required: 705 - Other - as specified
Resolved 29 May 2014
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 28 May 2014 Resolved
Provide fuel oil transfer procedures and line drawing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2014
Electrical › Electric Generation Source (service) › Panelboard
Issued 28 May 2014 Resolved
All lights out on switchboard. Vsl must replace/repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2014
Resolution: All switchboard lights now working
Lifesaving › Lifebuoys › Serviceable
Issued 28 May 2014 Resolved
Install new retro reflective tape to all lifebouys
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2014
Resolved 28 May 2014
Documentation › Certificates/Documents › Stability Letter
Issued 12 April 2007 Resolved
Blank old #2 tanks P&S at ballast manifold that contain inactive methanol tanks. Renumber tanks on manifold to match existing stability book.
Condition: Unknown
Due 26 May 2007
Resolved 9 May 2007
Resolution: Digital photos sent of blanked manifold.
Construction/Loadline › Structures › Door
Issued 12 April 2007 Resolved
Replace gasket material in watertight closures main deck and below (to hard rubber gasket).
Condition: Improper Installation
Due 26 May 2007
Resolved 10 August 2007
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 16 October 2006 Resolved
Prove ops of overspeed trip
Due 16 October 2006
Resolved 16 October 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 3 December 2004 Resolved
Provide on board, all required equipment as per 33 CFR 143 Subpart E for standby vessel service, and maintain on board as long as COI is endorsed for such service.
Action required: 705 - Other - as specified
Due 4 January 2005
Resolved 3 January 2005
Resolution: Standby Vessel equipment on board. Inventoried all equipment required by 33 CFR 143 Subpart E, all sat.
Fire Fighting › Fire Pumps
Issued 6 January 2004 Resolved
Crack in fire pump at pressure guage fitting. LEGACY COMPONENT DESC: Casing
Condition: Unknown
Due 7 January 2004
Resolved 7 January 2004
Resolution: Fire pump replaced.
Fire Fighting › Means of Escape
Issued 6 January 2004 Resolved
Escape ladder rungs were bent due to wastage of the steel. Four to be replaced. LEGACY COMPONENT DESC: Stairways
Condition: Improper/Lack of Maintenance
Due 7 January 2004
Resolved 7 January 2004
Resolution: ladder rungs replaced.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 16 October 2002 Resolved
COMPLETE COMPASS DEVIATION.
Action required: 705 - Other - as specified
Due 16 November 2002
Resolved 17 October 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 16 October 2002 Resolved
RENEW LIGHTING COVER ON FIXTURE IN ENGINEROOM.
Due 16 October 2002
Resolved 17 October 2002
Documentation
Issued 16 November 1993 Resolved
PROVIDE APPROVED PLANS FROM COAST GUARD MARINE SAFETY CENTER FOR THE CONVERSION OF THE DRY BULK TANKS TO METHONAL CARGO TANKS._x001C_
Condition: Unknown
Due 16 November 1993
Resolved 16 November 1993

Casualty record · 1

18 November 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1710999
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

M/V ERIKA LYNN (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.