MAURY USCG vessel records Sign in
← All vessels

LION IN THE SUN

LION IN THE SUN is a 1983 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1984, most recently in August 1999, along with 13 deficiencies.

Records from 1984 to 1999. Most recent: inspection, 16 August 1999.

Built
1983
Last inspected
16 August 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ2850
254530
Flag
UNITED STATES
—
Maury page id
psix-254530

Inspections, by type

…with no type recorded1
Years with a record 16 calendar years (1984–1999)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it38 - Simplified, Gross Ton
30 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCZ2850MMSI not assigned · expired · voluntarily equipped · granted 21 May 1999, cancelled 25 July 2009
WAN2733MMSI not assigned · expired · compulsorily equipped · granted 26 June 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

16 August 1999 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1093088
27 June 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1078057
21 October 1998 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 802863
6 March 1998 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1364625
18 June 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1413209
17 May 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1190036
24 April 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443693
28 April 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422505
7 June 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1174374
3 May 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1169405
23 August 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 842865
28 April 1993 Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 834928
5 May 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1254457
6 September 1991 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 933863
26 April 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215748
24 January 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215701
13 June 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 892778
26 July 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1038117
16 June 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 895255
15 March 1988 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1029121
1 July 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318873
28 May 1987 COI Inspection · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1028753
19 August 1986 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987188
25 June 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1302836
11 June 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1301620
25 September 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 994640
1 June 1984 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987482

Deficiency record · 13

Electrical
Issued 24 April 1996 Resolved
PROVIDE AND INSTALL A VAPOR DETECTOR IN THE GENERATOR COMPARTMENT WITH AN ALARM AT THE PILOT STATION.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 24 April 1996 Resolved
Provide 21 adult and 2 child PFD's, passenger capacity is reduced to 28 until the PFD's are provided.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Construction/Loadline
Issued 3 May 1994 Resolved
Provide hoses for the hand fire and bilge pump as necessary not later than the compliance date.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 3 May 1994 Resolved
Replace the faded out port running light lense not later than the compliance date.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 28 April 1993 Resolved
Provide new louvers for the portside ventilation ducts not later than the compliance date.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Accommodation/Occupational Safety
Issued 28 April 1993 Resolved
Provide garbage pollution placards as necessary for passenger viewing not later than the compliance date.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Fire Fighting
Issued 28 April 1993 Resolved
Provide effective hoses for the hand fire and bilge pump per_x001C_ 46 CFR 181.10-5 not later than the compliance date.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Lifesaving
Issued 16 June 1988 Resolved
PROVIDE 6 RED FLARES AND 6 ORANGE SMOKE DISTRESS SIGNALS OR 12 COMBINATION RED FLARE AND ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Electrical
Issued 28 May 1987 Resolved
PERMANENTLY CONNECT HOT LEADS TO BATHROOM SEWAGE PUMP.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Fire Fighting
Issued 28 May 1987 Resolved
INSTALL APPROVED FIXED FIRE EXTINGUISHING SYSTEM FOR MAIN ENGINE AND GENERATOR SPACES.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Electrical
Issued 28 May 1987 Resolved
PROVIDE ELECTRICAL BOX COVER ON SEWAGE PUMP SWITCH.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Engineering
Issued 11 June 1986 Resolved
PERMANENTLY SECURE FUEL FILL HOSE ABOVE STEERING TILLER TO PREVENT CHAFING OF HOSE ON TILLER BAR.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Engineering
Issued 11 June 1986 Resolved
REPLACE PLASTIC ENGINE COMPARTMENT AND AUXILIARY GENERATOR VENTILATION DUCTING WITH RIGID NON-COMBUSTIBLE TYPE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.