Records from 1984 to 1999. Most recent: inspection, 16 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
16 August 1999
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1093088
27 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1078057
21 October 1998
Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 802863
6 March 1998
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1364625
18 June 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1413209
17 May 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1190036
24 April 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443693
28 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422505
7 June 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1174374
3 May 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1169405
23 August 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 842865
28 April 1993
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 834928
5 May 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1254457
6 September 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 933863
26 April 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215748
24 January 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215701
13 June 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 892778
26 July 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1038117
16 June 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 895255
15 March 1988
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1029121
1 July 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318873
28 May 1987
COI Inspection · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1028753
19 August 1986
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987188
25 June 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1302836
11 June 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1301620
25 September 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 994640
1 June 1984
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987482
Electrical
Issued 24 April 1996
Resolved
PROVIDE AND INSTALL A VAPOR DETECTOR IN THE GENERATOR COMPARTMENT WITH AN ALARM AT THE PILOT STATION.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 24 April 1996
Resolved
Provide 21 adult and 2 child PFD's, passenger capacity is reduced to 28 until the PFD's are provided.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Construction/Loadline
Issued 3 May 1994
Resolved
Provide hoses for the hand fire and bilge pump as necessary not later than the compliance date.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 3 May 1994
Resolved
Replace the faded out port running light lense not later than the compliance date.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 28 April 1993
Resolved
Provide new louvers for the portside ventilation ducts not later than the compliance date.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Accommodation/Occupational Safety
Issued 28 April 1993
Resolved
Provide garbage pollution placards as necessary for passenger viewing not later than the compliance date.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Fire Fighting
Issued 28 April 1993
Resolved
Provide effective hoses for the hand fire and bilge pump per_x001C_ 46 CFR 181.10-5 not later than the compliance date.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Lifesaving
Issued 16 June 1988
Resolved
PROVIDE 6 RED FLARES AND 6 ORANGE SMOKE DISTRESS SIGNALS OR 12 COMBINATION RED FLARE AND ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Electrical
Issued 28 May 1987
Resolved
PERMANENTLY CONNECT HOT LEADS TO BATHROOM SEWAGE PUMP.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Fire Fighting
Issued 28 May 1987
Resolved
INSTALL APPROVED FIXED FIRE EXTINGUISHING SYSTEM FOR MAIN ENGINE AND GENERATOR SPACES.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Electrical
Issued 28 May 1987
Resolved
PROVIDE ELECTRICAL BOX COVER ON SEWAGE PUMP SWITCH.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Engineering
Issued 11 June 1986
Resolved
PERMANENTLY SECURE FUEL FILL HOSE ABOVE STEERING TILLER TO PREVENT CHAFING OF HOSE ON TILLER BAR.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Engineering
Issued 11 June 1986
Resolved
REPLACE PLASTIC ENGINE COMPARTMENT AND AUXILIARY GENERATOR VENTILATION DUCTING WITH RIGID NON-COMBUSTIBLE TYPE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986