Records from 2001 to 2010. Most recent: inspection, 14 September 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
14 September 2010
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3856583
1 March 2010
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3688070
14 May 2009
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3443144
23 March 2009
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3438484
12 June 2008
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3233705
15 May 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3207459
28 February 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3154544
3 May 2007
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2921692
31 May 2006
MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2666290
24 October 2005
Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2521482
10 May 2005
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2352791
30 March 2004
Re-Inspection · Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2066298
14 May 2003
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1793523
18 June 2002
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1619531
23 April 2002
Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1608320
11 April 2001
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1444516
Fire Fighting › Fire Hoses › Material
Issued 14 May 2009
Resolved
Provide new fire hose and nozzle (good grade hose).
Due 21 May 2009
Resolved 21 May 2009
Personnel › Training › First Aid/CPR
Issued 14 May 2009
Resolved
Provide first aid training to the crew.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 27 April 2010
Fire Fighting › Fire Hoses › Connections
Issued 14 May 2009
Resolved
Properly double clamp all hose fittings on fire pump system
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 21 May 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 May 2009
Resolved
Attach a 6' lanyard (line) with snap ring from the water light to the life ring
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 21 May 2009
Engineering › Fuel Oil Service System › Hose
Issued 14 May 2009
Resolved
Prove proper operation of quick releases on both gasoline fuel tank's hoses.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 21 May 2009
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 14 May 2009
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 21 May 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 June 2008
Resolved
Ownership shall provide written documentation to Coast Guard Sector New York to the fact that a satisfactory man overboard drill was conducted with a licensed Master. Master was unavailable during the second annual inspection therefore no drills were conducted. Master is also required to provide mariners license number on written documentation for successful completion of the MOB drill.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 June 2008
Resolved
Have Master provide proof in writing of enrollment in drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 June 2008
Resolved
Provide proof that all portable fire extinguishers are inspected and serviced. Last service date of the portable fire extinguishers was April 2007.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 June 2008
Resolved
Provide all navigational publications required in accordance with 46 CFR 184.420.
Due 19 June 2008
Resolved 13 June 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 June 2008
Resolved
Prove proper operation of the combination stern/anchor light. Vessel is restricted to daylight operations until operation is verified.
Due 19 June 2008
Resolved 13 June 2008
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2007
Resolved
Provide valid FCC Radio Safety Certificate to USCG MI. Vessel is restricted to no more than 1000ft from shore until item is cleared.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 29 February 2008
Resolution: Vessel route reduced to within 1000ft from shore.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 May 2007
Resolved
Provide self-activating waterlight for ring buoy. Vessel is restricted to daytime operations only until item is cleared.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 17 May 2007
Resolution: New light provided.
Fire Fighting › Fire Hoses › Number
Issued 3 May 2007
Resolved
Affix hose to fire pump or provide 03 firebuckets onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2007
Resolution: Hose attached with double clamps to fire pump.
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2007
Resolved
Provide valid FCC Marine Radio Operator Permit for vessel master to USCG MI.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 29 February 2008
Resolution: Vessel route reduced to within 1000ft from shore.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 May 2007
Resolved
Post COI in view of passengers.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: COI posted.
Documentation › Logs/Records › Logbook (official)
Issued 3 May 2007
Resolved
Provide logbook for training and bridge onboard vessel.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: Logbook provided onboard.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 May 2007
Resolved
Provide means of leaving accurate passenger count on shore for each voyage.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: Call in to Highlands Business Partnership and leave information.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 May 2007
Resolved
Provide lifejacket stowage for excess child lifejackets.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: PFD stowage provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2007
Resolved
Replace missing/expired medications in first-aid kit.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: New meds provided.
Engineering › Bilge Water Management System › Hose
Issued 3 May 2007
Resolved
Double clamp flex hose for bilge overboard.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 16 May 2007
Resolution: Bilge hose double clamped.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 May 2007
Resolved
Provide proof of drug and alcohol screening program enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2007
Resolution: Received fax containing proof of enrollment.