MAURY USCG vessel records Sign in
← All vessels

ELSA

ELSA is a 1985 freight ship. The Coast Guard has recorded 21 inspections since 1985, most recently in July 2004, along with 26 deficiencies and 7 operational controls.

Records from 1985 to 2004. Most recent: inspection, 3 July 2004.

Built
1985
Last inspected
3 July 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8322040 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
254816
Flag
NETHERLANDS
—
Maury page id
psix-254816

Inspections, by type

…with no type recorded11
Years with a record 7 calendar years (1985–2004)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2419 - Regulatory (Subpart C or D), Net Ton
2419 - Convention (Subpart B), Net Ton
3986 - Regulatory (Subpart C or D), Gross Ton
3986 - Convention (Subpart B), Gross Ton
6025 - Dead Weight, Ton
8510 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

3 July 2004 PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2119635
29 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2123283
28 June 2004 PII Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2114263
27 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2111602
25 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2110870
14 January 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1984989
27 October 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1937783
25 October 2003 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1936141
24 October 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1941977
17 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1930709
12 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1904644
7 June 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1811768
21 April 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1779110
18 August 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1663762
22 July 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1650380
22 September 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 433008
16 November 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 422626
10 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367651
7 May 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 366568
11 September 1985 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 304208
31 August 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 303944

Deficiency record · 26

Construction/Loadline › Hull › Double Hull
Issued 27 October 2003 Resolved
No. 4 port ballast tank top iwo no. 3 port fuel oil tank between frames 38 and 44 are to be cropped and renewed as found necessary by 04/04. Both tanks are not to be used until class report attesting to satisfactory repairs is provided to local Coast Guard Marine Safety Office.
Condition: Unknown
Due 4 April 2004
Resolved 3 July 2004
Resolution: Recieved class report attesting to condition of class being issued for the area in question.
Construction/Loadline › Hull › Bottom Plating
Issued 27 October 2003 Resolved
Provide photographs of repair to the fracture in #3 port fuel oil wing tank/#4 port ballast tank top.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2003
Resolved 29 October 2003
Resolution: Received photographs of repairs.
Deck/Cargo › Ballast
Issued 25 October 2003 Resolved
Vessel found fracture in #3 port fuel tank which contaminated #4 port ballast tank. Vessel made repairs on their own without notifying class. Have repairs approved by class prior to departure. LEGACY COMPONENT DESC: Tank
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2003
Resolved 29 October 2003
Resolution: Received class report attesting to satisfactory permanent repairs.
Operations/Management › Vessel Safety Management
Issued 25 October 2003 Resolved
Vessel failed to notify classification society regarding fracture in tank and repair approval. Vessel required to follow proper notification procedures. LEGACY COMPONENT DESC: Plans for Shipboard Operations
Action required: 705 - Other - as specified
Due 26 October 2003
Resolved 29 October 2003
Resolution: Class addressed issue.
Operations/Management › Equipment Service/Testing
Issued 25 October 2003 Resolved
Vessel failed to use proper atmoshpheric testing equipment onboard for confined space entry and "safe for hotwork" determination prior to conducting hotwork in a fuel tank and in a ballast tank contamintated with fuel. Vessel shall have proper testing equipment onboard. LEGACY COMPONENT DESC: LEL Testing
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2003
Resolved 29 October 2003
Resolution: Class confirmed proper equipment is now onboard.
Operations/Management › Vessel Safety Management
Issued 25 October 2003 Resolved
Vessel Safety Management System does not adequately cover safe work practices for determining a space is safe for hotwork. Vessel recently completely hotwork in a fuel tank without atmospheric testing. However, according to SMS, all they needed to do was have chief engineer or master approval. LEGACY COMPONENT DESC: Plans for Shipboard Operations
Action required: 705 - Other - as specified
Due 26 October 2003
Resolved 29 October 2003
Resolution: LR Class addressed issue.
Operations/Management › Vessel Safety Management
Issued 25 October 2003 Resolved
COTP Houston-Galveston questions the validity of the Safety Management Certificate based on the deficies identified on this boarding and the other defs found on recent PSC annual inspection conducted by HOUMS on 17OCT03. Vessel required to conduct external audit of SMS by issuing authority. LEGACY COMPONENT DESC: External Certification/Verification/Control
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2003
Resolved 29 October 2003
Resolution: LR conducted ISM Audit and provided report.
Engineering › Steering Gear System
Issued 17 October 2003 Resolved
Rudder angel indicator is reading inaccurate while operating on the #2 steering pump. Port side angle indicator is off also off by 10 degrees (SOLAS 74 V/12(m)). LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2003
Resolution: Received report from class attesting to the correction of the deficiency.
Engineering › Steering Gear System
Issued 17 October 2003 Resolved
Pump #2 is malfunctioning. When switch on rudder jumps 5 degrees off course (SOLAS 74 II-1/29). LEGACY COMPONENT DESC: Pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2003
Resolution: Received report from class attesting to the correction of the deficiency.
Lifesaving › Rescue Boat
Issued 17 October 2003 Resolved
Rescue boat motor is inopertive due to broken fuel line (SOLAS 74 III/8(b)). Repair fuel line and test engine. LEGACY COMPONENT DESC: Propulsion Engine
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2003
Resolution: Received report from class attesting to the correction of the deficiency.
Operations/Management › Vessel Safety Management
Issued 17 October 2003 Resolved
Vessel is missing its Fire Fighting Operational Manual (SOLAS II-2/15.2.3) Replace manual. LEGACY COMPONENT DESC: Emergency Preparedness
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 24 October 2003
Resolution: Received report from class attesting to the vessel possession of a Fire Operational book.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 June 2003 Resolved
received request for deviation due to lose of gyro
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2003
Resolved 7 June 2003
Resolution: Received tech rep report attesting to repairs, test sat.
Fire Fighting › Emergency Fire Pumps
Issued 22 July 2002 Resolved
Insufficient water pressure on emergency fire pump. Solas II-2 Regulation 4.3.3.2 LEGACY COMPONENT DESC: Pressure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Resolution: Received letter from class confirming that necessary repairs have been made to the satisfaction of the approving administration.
Lifesaving
Issued 22 September 1999 Resolved
SERVICE SHIPBOARD LIFERAFTS AT THE NEXT PORT HOUSTON, TX. PRIOR TO DEPARTURE. SOLAS 74 (Amended)III/19.8.1
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Navigation
Issued 22 September 1999 Resolved
PROVIDE TIDAL CURRENT OR STREAM TABLES FOR GULF OF MEXICO PRIOR TO DEPARTURE FROM NEXT PORT. 33CFR 164.33
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Documentation
Issued 22 September 1999 Resolved
CONSOLIDATE FIRE EQUIPMENT MAINTENANCE INSPECTIONS, SCBA TANK READINGS AND LIFESAVING EQUIPMENT INSPECTIONS INTO ONE MANUAL. _x001C_ SOLAS 74(Amended) II-2 Reg 20/1
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Fire Fighting
Issued 22 September 1999 Resolved
FLAG STATE TO ADDRESS THE FIREFIGHTING ARRANGEMENTS IN THE PAINT_x001C_ LOCKER/EDG ROOM AND ADDRESS LACK OF ACCESSIBLE EXTINGUISHER AT THE ENTRANCETHEREOF, UPON RETURN TO U.S. PORT AFTER VOYAGE TERMINATION_x001C_ SOLAS 74 (Amended) II/2 A.6
Condition: Unknown
Due 6 October 1999
Resolved 22 July 2002
Resolution: Arrangments for/of paint lockers are according to the discretion of the administration.
Unknown
Issued 22 September 1999 Resolved
f
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Navigation
Issued 16 November 1998 Resolved
HOSES AND CORDS BLOCKED SIGHT OF THE STEERING GEAR SCHEMATAIC IN STEERING GEAR SPACE.
Condition: Unknown
Due 20 December 1998
Resolved 7 December 1998
Lifesaving
Issued 16 November 1998 Resolved
POST LEGIBLE FIRE CONTROL PLAN IN SHIP'S PASSAGEWAYS. CURRENT FIRE CONTROLPLAN IS FADED AND ILLEGIBLE._x001C_ _x001C_ TO BE CORRECTED PRIOR TO 20DEC98
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Navigation
Issued 7 May 1994 Resolved
VSL'S COAST PILOT FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 20 June 1994
Resolved 14 June 1994
Navigation
Issued 7 May 1994 Resolved
VSL HAS NO TIDE OR TIDAL CURRENT TABLES FOR AREA TRANSITED._x001C_
Condition: Unknown
Due 10 June 1994
Resolved 10 June 1994
Navigation
Issued 7 May 1994 Resolved
VSL'S MANEUVERING FACT SHEET INCOMPLETE.
Condition: Unknown
Due 10 June 1994
Resolved 10 June 1994
Navigation
Issued 7 May 1994 Resolved
VSL'S LIGHT LIST FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 10 June 1994
Resolved 10 June 1994
Documentation
Issued 31 August 1985 Resolved
NO OIL TRANSFER PROCEDURES. MASTER STATED "WE DONT HAVE ANY WRITTEN DOWN" WHEN ASKED FOR THE TRANSFER PROCEDURES.
Condition: Unknown
Due 31 August 1985
Resolved 31 August 1985
Navigation
Issued 31 August 1985 Resolved
NO TIDAL CURRENT TABLES ONBOARD. WHEN ASKED, THE MATE SAID "I DON'T HAVE SUCH A BOOK."
Condition: Unknown
Due 31 August 1985
Resolved 31 August 1985

Ownership record