SIFNOS BAY is a 1985 freight ship. The Coast Guard has recorded 45 inspections since 1986, most recently in May 2007, along with 35 deficiencies and 12 operational controls, 2 with no removal date recorded.
Records from 1986 to 2007. Most recent: inspection, 14 May 2007.
- Built
- 1985
- Last inspected
- 14 May 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- 2 with no removal date recorded
Identity
8507535 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HFJ7
255294
Flag
MALTA
—
Maury page id
psix-255294
Inspections, by type
The 45 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it15832 - Convention (Subpart B), Gross Ton
8990 - Convention (Subpart B), Net Ton
32207 - Displacement, Ton
26591 - Dead Weight, Ton
8990 - Convention (Subpart B), Net Ton
32207 - Displacement, Ton
26591 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 45
14 May 2007
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2925191
26 September 2005
PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2501617
18 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2314184
7 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2306387
18 February 2005
PII Safety Exam · Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2294346
18 February 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2295442
11 February 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2291131
1 February 2005
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2284842
17 September 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2198441
19 August 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2170377
18 August 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2170205
13 August 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2164863
13 August 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2165307
6 April 2004
Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2038630
4 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2041171
16 March 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2033893
11 March 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2022546
10 March 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2029531
5 November 2003
Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1942784
15 August 2003
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1876793
30 January 2003
Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1737655
23 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1722551
16 December 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1719800
4 March 2001
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 288003
13 September 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 281969
9 April 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 427342
25 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 426908
25 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 427193
14 August 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 393841
20 October 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 361823
31 December 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 488024
16 December 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 355126
21 October 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 353833
10 May 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350798
13 December 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 684359
19 November 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 684358
31 October 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 346824
24 June 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 344542
1 October 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 339605
27 March 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 336104
10 February 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 328268
24 December 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 320213
19 June 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 536479
3 November 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 312465
14 April 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 471387
Deficiency record · 35
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 May 2007
Resolved
A total of 15 food rations on both lifeboats were found to have broken vacuum seals and had gone bad. After the removal of the bad rations, each lifeboat no longer had enough to be able to provide for its full capacity. Purchase a sufficient amount of food rations to be able to provide for the full capacity of each lifeboat and provide proof to the Coast Guard by 21May07.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 26 September 2005
Resolved
Conduct repairs or renewal of the MSD system to the satisfaction of the Flag Administration. Tank has numerous temporary repairs to the tank plating and top plate is holed.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 6 April 2004
Resolved
No. 3 auxiliary diesel generator, No. 3 high pressure injection pump has an excessive fuel oil leak. Do not operate until repairs are made to the satisfaction of class. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 6 April 2004
Resolved
No.3 auxiliary diesel generator, No. 5 high pressure injection pump has a notable leak. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 6 April 2004
Resolved
The auxiliary diesel generator booster pump steam supply line is patched and leaking. LEGACY COMPONENT DESC: Booster Pump
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 6 April 2004
Resolved
No. 1 auxiliary diesel generator, No. 3 cylinder has a notable cooling water leak and lube oil leak. LEGACY COMPONENT DESC: Piping
Engineering › Steering Gear System › Differential Assembly
Issued 22 March 2004
Resolved
Condition of Class imposed to have worn parts to the steering gear replaced within the next 3 months (22 June 2004). LEGACY COMPONENT DESC: Worn Parts
Operations/Management › Drills/Instruction
Issued 16 March 2004
Resolved
VESSEL FAILED TO PERFORM A SATISFACTORY ABANDON SHIP DRILL. AS REQUIRED BY SOLAS 74/78 CH.III/REG.18. TO BE CONDUCTED, SATISFACTORY, IN PRESENCE OF A COAST GUARD INSPECTOR, PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Abandon Ship
Operations/Management › Vessel Safety Management
Issued 16 March 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Vessel Safety Management
Issued 16 March 2004
Resolved
BASED ON UNSAT FIRE & ABANDON SHIP DRILLS, PERFORMED BY THE VSL'S CREW ON TWO OCCASIONS, THE VALIDALITY OF THE VSL'S TRNG & DRILLS AS PER THE VSL'S SMS HAS BEEN CALLED INTO QUESTION. AS REQUIRED BY 33CFR96.250(g)&(h) & SOLAS 74/78 CH.IX. TO BE ADDRESSED BY VSL'S FLAG OR R.O., PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Resources and Personnel
Lifesaving › Inflatable Liferafts
Issued 11 March 2004
Resolved
VESSEL'S 6-MAN LIFERAFT IS DUE FOR SERVICE. AS REQUIRED BY SOLAS 74/78 CH.III/REG.19.8.1.1. TO BE CORRECTED PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: EXPIRED SERVICE DATE
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 11 March 2004
Resolved
VESSEL IS MISSING 5 WEEKS OF NOTICES TO MARINERS - CONSEQUENTLY, CHARTS AND PUBS ARE NOT UPDATED. AS REQUIRED BY 33CFR164.33(a)(ii). TO BE CORRECTED PRIOR TO DEPARTURE.
Fire Fighting › Fire Hydrants
Issued 11 March 2004
Resolved
VESSEL'S FIRE MAIN HYDRANT LOCATED AFT OF #1 CARGO HATCH PORT SIDE MAIN DECK WAS FOUND UNABLE TO BE SECURED. AS REQUIRED BY SOLAS 74/78 CH.II-2/REG.4.6 LEGACY COMPONENT DESC: Condition
Operations/Management › Drills/Instruction
Issued 11 March 2004
Resolved
VESSEL'S CREW FAILED TO PERFORM A SATISFACTORY FIRE DRILL. AS REQUIRED BY SOLAS 74/78 CH.III/REG.18. TO BE CONDUCTED, SATISFACTORY, IN PRESENCE OF A COAST GUARD INSPECTOR, PRIOR TO DEAPRTURE. LEGACY COMPONENT DESC: FIRE DRILL
Engineering › Fuel Oil Service System
Issued 11 March 2004
Resolved
VESSEL HAS TWO LEAKING STEAM LINES; ONE WITH SOFT PATCH, LOCATED #1 & #2 FUEL OIL BOOSTER PUMP AREA AND ONE AROUND THE STUFFING LUBE OIL BOX AREA. THEY WERE FOUND UNABLE TO WITHSTAND MAX WORKING PRESSURE. AS REQUIRED BY SOLAS 74/78 CH.II-1/REG.33.1. VESSEL'S CLASS TO ADDRESS PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Steam Heating Lines
Engineering › Generator (propulsion/auxiliary-electric)
Issued 11 March 2004
Resolved
VESSEL HAS A 2 FOOT SOFT PATCH LOCATED ON THE MAIN SALT WATER LINE FOR THE MAIN SHIPBOARD GENERATORS. AS REQUIRED BY SOLAS 74/78 CH.II-1/REG.26.1. TO BE ADDRESSED BY CLASS PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: MAIN SALTWATER SUPPLY
Fire Fighting › Emergency Fire Pumps
Issued 15 August 2003
Resolved
Permanently repair or replace electrical starter box for emergency fire pump. LEGACY COMPONENT DESC: Power Source
Electrical › Lighting (service)
Issued 15 August 2003
Resolved
Permanently affix lighting on engine room second deck in the vicinity of main engine controls. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Electric Generation Source (emergency)
Issued 15 August 2003
Resolved
Make permanent repairs to emergency generator exhaust where leaking. LEGACY COMPONENT DESC: Generator
Engineering › Steering Gear System
Issued 16 December 2002
Resolved
Noted significant lateral, and forward and aft movement of rudder post within the bearing. LEGACY COMPONENT DESC: Rudder Bearing
Pollution Prevention/Response › Prevention Equipment
Issued 16 December 2002
Resolved
Wasted piping on top of sewage tank. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Engineering › Lubricating Oil Storage/Transfer System
Issued 16 December 2002
Resolved
Crew is installing a fill valve, T-connection on top of Main Engine Cylinder oil tank #1 to connect to the other cylinder oil tank. LEGACY COMPONENT DESC: Tank
Engineering › Sea-water System (primary cooling)
Issued 16 December 2002
Resolved
No. 3 generator cooling water to intercooler piping has a temporary patch. LEGACY COMPONENT DESC: Piping
Pollution Prevention/Response › Prevention Equipment
Issued 16 December 2002
Resolved
Sewage overboard piping has a temporary patch above the check valve. LEGACY COMPONENT DESC: Sewage System Piping
Lifesaving
Issued 25 March 1999
Resolved
UPON SPOT INSPECTION WATER LIGHTS ON PFD'S WERE NOT WORKING. CORRECT AS NEEDED. CORRECT PRIOR TO DEPARTURE.
Construction/Loadline
Issued 14 August 1996
Resolved
MAKE PERMANENT REPAIRS TO SCUPPER DISCHARGE LINE AT CEMENT BOX LOCATED PORTSIDE LOWER ENGINEROOM (ABOVE OWS) PRIOR TO NEXT U.S. PORT CALL FROM A FOREIGN PORT. ILLC CHAP II REG 22
Navigation
Issued 31 October 1991
Resolved
VESSEL NOT CARRYING CURRENT U.S. CHART #18521.
Navigation
Issued 31 October 1991
Resolved
VESSEL NOT CARRYING CURRENT U.S. CHART #18523.
Navigation
Issued 31 October 1991
Resolved
VESSEL NOT CARRYING CURRENT U.S. CHART #18524.
Navigation
Issued 27 March 1990
Resolved
33CFR164.11(Q) THE TEST REQUIRED BY 33CFR164.25 WERE NOT CONDUCTED OR LOGGED. AUTHORITY CITE: 33USC1223 PENALTY CITE: 33USC1232
Unknown
Issued 27 March 1990
Resolved
33CFR157.67 IMPROPER DISPOSAL OF PLASTICS. AUTHORITY CITE: 33USC1903 PENALTY CITE:33USC1908
Navigation
Issued 27 March 1990
Resolved
33CFR164.33(A)(1)(II) CHARTS 11324, 11327, 11328, AND 11329 NOT CORRECTED. AUTHORITY CITE: 33USC1223 PENALTY CITE: 33USC1232
Navigation
Issued 27 March 1990
Resolved
33CFR164.33(A)(2)(I) COAST PILOT VOL. 5 NOT CORRECTED. AUTHORITY CITE: 33USC1223 PENALTY CITE: 33USC1232
Navigation
Issued 27 March 1990
Resolved
33CFR164.33(A)(2)(II) COAST GUARD LIGHT LIST VOL. 4 UNCORRECTED. AUTHORITY CITE: 33USC1223 PENALTY CITE: 33USC1232
Navigation
Issued 3 November 1986
Resolved
PROVIDE TIDAL CURRENT TABLES OR FOREIGN GOVERNMENT EQUIVALENT ON BOARD IN ACCORDANCE WITH 33CFR164.33(A)(3)(II).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.