MAURY USCG vessel records Sign in
← All vessels

TERORO II

TERORO II is a 1985 passenger vessel (inspected). The Coast Guard has recorded 85 inspections since 1985, most recently in May 2026, along with 76 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 12 May 2026.

Built
1985
Last inspected
12 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3142
255395
Flag
UNITED STATES
—
Maury page id
psix-255395

Inspections, by type

…with no type recorded4
Years with a record 41 calendar years (1985–2026)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 85

12 May 2026 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8371874
9 December 2025 Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8277232
2 April 2025 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8104053
1 December 2024 Examination of Repairs · In-Service Inspection · Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8041481
25 November 2024 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8038392
15 August 2024 In-Service Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7981928
30 November 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7831688
1 December 2022 Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7595389
17 November 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7600587
6 December 2021 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7362954
1 December 2021 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7355479
7 December 2020 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7107493
3 November 2020 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7088709
2 December 2019 DAPI Audit · COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6865255
11 December 2018 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6750832
7 November 2018 Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6576300
25 October 2017 In-Service Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6295205
15 November 2016 DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6041354
26 October 2016 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6029972
7 December 2015 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5776859
17 October 2014 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5009336
20 January 2012 DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4343410
12 January 2011 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3960311
6 October 2010 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3878619
8 January 2010 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3660279
12 January 2009 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3392502
3 October 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3339636
11 January 2008 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3128487
11 January 2007 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2854129
15 September 2006 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2786956
13 January 2006 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2566261
13 January 2005 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2274061
15 October 2004 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2224067
12 January 2004 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1983951
13 January 2003 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1730673
23 December 2002 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1725371
16 January 2002 Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1478731
11 October 2001 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1479281
19 January 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366132
14 January 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1423321
1 October 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1449249
30 August 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1399172
14 June 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1192937
27 April 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 790553
2 March 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1131985
10 February 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1130181
15 January 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1369000
11 January 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1402761
30 December 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 48951
14 January 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1450119
25 August 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1433241
8 July 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1117009
14 January 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1413110
26 November 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 51032
26 November 1996 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1374828
16 February 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879437
16 January 1996 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1183732
2 November 1995 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1193746
21 September 1995 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879884
18 January 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 864860
12 January 1995 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 862033
14 January 1994 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1162544
14 December 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1159345
23 September 1993 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1139488
27 April 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 832600
19 April 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 839482
15 March 1993 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 839661
22 January 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1144466
6 November 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1136591
26 March 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 944511
13 February 1992 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 951996
23 September 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 951997
17 January 1991 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 929132
17 April 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1224827
2 April 1990 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 905901
1 March 1990 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1226833
26 January 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 914994
20 January 1989 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 891131
12 October 1988 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201552
19 January 1988 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1320855
1 June 1987 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1342386
23 January 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1321457
23 January 1986 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 995290
16 December 1985 Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1297237
29 January 1985 Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1296855

Deficiency record · 76

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2025 Resolved
Each life jacket must be approved under approval series in 46 CFR Subchapter Q. Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Retro-reflective tape on the child life jackets and older adult life jackets was found to be worn/deteriorated. The vessel's name was not clearly marked on all life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 10 December 2025
Resolution: Life jackets have been fitted with new retro-reflective tape and have had the vessel name marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 December 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The vessel is overdue for its drydock and internal structural examinations.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2024
Resolution: The vessel is hauled out and has begun its drydock and internal structural examinations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 November 2024 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The vessel carries two EPIRBS and the batteries were found to have expired in 2019 and 2021. The EPIRB's cradle was found to be inside the main hull and is not installed in a float-free location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 30 November 2024
Resolution: A new battery (SEP2030 expiration) has been installed on the ACR EPIRB.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2024 Resolved
A power-driven vessel underway shall exhibit sidelights. The port and starboard running light were not operating properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 2 December 2024
Resolution: A new positive wire has been installed and operator proved proper operation of running lights.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 November 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR subchapter W or a kit with equivalent contents and instructions. Numerous items in the first aid kit were found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 30 November 2024
Resolution: New medical supplies have been purchased.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 November 2024 Resolved
A vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication and Coast Guard Light List. The U.S. Coast Pilot publication could not be produced and the Cost Guard Light List was outdated.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 2 December 2024
Resolution: Coast Guard Light List and U.S. Coast Pilot are now maintained on board the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 25 November 2024 Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06. The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. Vessel representatives could not provide a crew list covered by the Consortium testing program.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 25 November 2024
Resolution: Vessel owner provided covered crew list.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 November 2024 Resolved
Each EPIRB must be tested monthly, which shall be logged or otherwise documented. The last logged EPIRB test was in December 2023.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 30 November 2024
Resolution: EPIRB tests are being logged.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 November 2024 Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. The vessel's Communications Act Safety Radiotelephony Certificate expired in September 2024.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2024
Resolved 22 December 2024
Resolution: Received a photo of the newly-issued and corrected FCC Radiotelephony Certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 December 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Fire extinguishers have not had a annual service inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2023
Resolved 18 December 2023
Resolution: Fire extinguishers have been serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 December 2023 Resolved
A vessel on a limited coastwise route must carry six hand red flares distress signals approved in accordance with 160.021 in subchapter Q. Vessel has a pack on expired red flares.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2023
Resolved 18 December 2023
Resolution: New flares have been purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 December 2023 Resolved
The items contained in the first aid kit shall be as listed in table 160.041(b). Aspirin is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2024
Resolved 18 December 2023
Resolution: New aspirin has been purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2022 Resolved
Ring buoys shall be of first class workmanship and free from any defects materially affecting their appearance and serviceability. Life buoy has a defective seal along middle of bouy and needs to be replaced or repaired according to manufactures instruction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2022
Resolved 13 December 2022
Resolution: New ring buoy has been purchased.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2022 Resolved
Fire Buckets are required to have the words "FIRE BUCKET" stenciled in a contrasting color on each bucket and not used for any other purpose than intended as a fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2022
Resolved 13 December 2022
Resolution: Fire buckets have been labeled correctly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 December 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2022
Resolved 13 December 2022
Resolution: 2 portable lights have been placed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 December 2022 Resolved
Request copy of vessel's preventative maintenance plan (PMP).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2022
Resolved 13 December 2022
Resolution: Copy of vessel's PMP has been provided to MI.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 December 2022 Resolved
Fire and man overboard drills shall be logged or otherwise documented for review by the Coast Guard upon request. The log book is in a dilapidated state and needs to be updated/replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2022
Resolved 13 December 2022
Resolution: Vessel has started a new log book.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2021 Resolved
14 life jackets have been found to be in a dilapidated state and not fit for service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2021
Resolved 6 December 2021
Resolution: Received photo documentation of 20 new life jackets being shipped to vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2020 Resolved
Stern light inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: Light was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2020 Resolved
Extinguishers require servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: Extinguishers serviced and one renewed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 December 2020 Resolved
Bilge alarm was inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: Alarm renewed and tested, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2020 Resolved
First aid kit was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: New first aid kit onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2020 Resolved
Fire buckets need labled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: All buckets labled.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 7 December 2020 Resolved
Flares were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: Flares renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2020 Resolved
Vessels name not affixed to stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 11 December 2020
Resolution: Name has been remarked.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 December 2019 Resolved
Portable fire extinguishers were not serviced annually. Required fire extinguishers to be annually serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2020
Resolved 2 December 2019
Resolution: Fire extinguishers were serviced the same day after the inspection was complete.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 December 2019 Resolved
Vessel is required to have (03) 2.5 gallon fire buckets. Vessel did not have required number or size.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 2 December 2019
Resolution: Fire buckets were purchased same day after inspection was completed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 December 2019 Resolved
Items in first aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 2 December 2019
Resolution: Items were purchased same day and expired items replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2019 Resolved
Repair backing plate at end of boom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 23 December 2019
Resolution: Repaired backing plate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 December 2018 Resolved
Items in vessels first aid kit expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2019
Resolved 12 December 2018
Resolution: Items renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2018 Resolved
PFDs stored in plastic bags underneath vessel seats; with zero ventilation inside bags, PFDs became moldy and slimy causing retro reflective tape to fall off.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2019
Resolved 11 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 December 2018 Resolved
Vessel water light inop. Restricted to daytime operations only until rectified.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2019
Resolved 11 December 2018
Resolution: New battery installed and operational.
Lifesaving › Lifebuoys › Serviceable
Issued 30 October 2017 Resolved
Replace unservicable lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2017
Resolution: Owner obtained new lifering.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 October 2017 Resolved
Replace 05 unservicable adult and 01 unservicable child lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2018
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 25 October 2017 Resolved
Remove fungal growth from lifejackets and replace retroreflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2018
Lifesaving › Hand Flares › Expired
Issued 7 December 2015 Resolved
2 hand signals expired. 6 smoke signals expired.
Due 7 December 2015
Resolved 7 December 2015
Resolution: New distress signals provided.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 December 2015 Resolved
Float free waterlight battery dead.
Due 7 December 2015
Resolved 7 December 2015
Resolution: New battery provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 December 2015 Resolved
Tide/Currents not onboard vessel.
Due 7 January 2016
Resolved 7 December 2015
Resolution: Tide/currents provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 December 2015 Resolved
Light list not onboard vessel.
Due 7 January 2016
Resolved 7 December 2015
Resolution: Provided current light list.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 January 2011 Resolved
Provide CG approved first aid kit.
Due 12 February 2011
Resolved 20 January 2012
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 12 January 2011 Resolved
Provide rigging survey.
Due 1 December 2011
Resolved 1 March 2012
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 January 2011 Resolved
Provide water light lanyard.
Due 27 January 2011
Resolved 20 January 2012
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 January 2011 Resolved
Provide EAP program details.
Due 12 February 2011
Resolved 20 January 2012
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 January 2011 Resolved
Provide marine employer consortium enrollment proof.
Due 27 January 2011
Resolved 13 January 2011
Resolution: fax received
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 January 2010 Resolved
Both fire extinguishers required to be annually serviced.
Due 15 January 2010
Resolved 11 January 2010
Documentation
Issued 11 January 1999 Resolved
Provide evidence of compliance with chemical testing regulations to include: a. Copy of contract, b. crews list, c. dates of employment, d. pre-employment tests, e. random tests, f. employee assistance program, g. most recent MIS, h & i SMI & reasonable cause testing, j. Supervisor trng.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
Provide evidence of compliance with weekly inspection of survival craft.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Fire Fighting
Issued 11 January 1999 Resolved
Renew portable extinguisher bracket in vicinity of the electrical distribution panel.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999 Resolved
Update charts.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
Provide evidence of compliance with maintenance of survival craft.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999 Resolved
Provide evidence of compliance with crew training iaw 46 CFR 185.420.
Condition: Unknown
Due 11 February 1999
Resolved 12 January 1999
Documentation
Issued 11 January 1999 Resolved
Provide evidence of compliance with drills and training iaw 46 CFR 185.520.
Condition: Unknown
Due 11 February 1999
Resolved 12 January 1999
Construction/Loadline
Issued 11 January 1999 Resolved
Make 20 percent of chainplate fasteners available for inspection.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Fire Fighting
Issued 11 January 1999 Resolved
Provide evidence of testing and maintenance of portable extinguishers.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Documentation
Issued 11 January 1999 Resolved
Provide waste management plan.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Construction/Loadline
Issued 11 January 1999 Resolved
Renew gooseneck swivel.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Lifesaving
Issued 11 January 1999 Resolved
Install EPIRB to float free.
Condition: Unknown
Due 11 February 1999
Resolved 12 January 1999
Fire Fighting
Issued 14 January 1998 Resolved
Weight test extinguisher bottles.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998 Resolved
Remount EPIRB in on the exterior of the vessel so that it will float free and automatically activate.
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1998 Resolved
Stencil vessel name and provide retroreflective tape on new life ring bouys
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Lifesaving
Issued 14 January 1997 Resolved
Provide "bright" water tight container clearly marked "Distress Signals" for flares IAW 46CFR185.614
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 14 January 1997 Resolved
Log all abandon ship and man over board drills IAW 185.520(g)
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Lifesaving
Issued 14 January 1997 Resolved
Provide retroreflective tape on life ring buoys IAW 46CFR185.604(i)
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Unknown
Issued 14 January 1997 Resolved
Provide first aid kit IAW 46CFR184.710
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Navigation
Issued 14 January 1997 Resolved
Provide a radio emergency broadcast placard IAW 46CFR185.406
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 14 January 1997 Resolved
Log crew training IAW 46CFR185.420(b)
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Documentation
Issued 14 January 1997 Resolved
Log fire fighting drills IAW 46CFR185.524(e)
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Deck/Cargo
Issued 26 November 1996 Resolved
Repair damage to mast from accident.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Deck/Cargo
Issued 26 November 1996 Resolved
Replace main shackle on standing rigging for a rotating wing mast.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Lifesaving
Issued 16 January 1996 Resolved
Provide on board prior to departure, 12 distress signals. Six hand held red and six hand held orange signals.
Condition: Unknown
Due 16 January 1996
Resolved 17 January 1996
Lifesaving
Issued 16 January 1996 Resolved
Make permanent repairs to tears in way of the lifefloat's cover.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Deck/Cargo
Issued 12 January 1995 Resolved
Make weld repairs to cracks in way of aluminum block fitted between boom and mast. Repairs are to be inspected by a USCG Marine Inspector._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Construction/Loadline
Issued 6 November 1992 Resolved
AT NEXT DRYDOCK REPLACE THE PVC THRU HULL FITTING AND SEA VALVE FOR MSD SUCTION WITH METALLIC FITTINGS, OR SHOW PROOF OF CURRENT INSTALLATION MEETING THE REQUIREMENTS OF 46 CFR 182.40 FOR NON METALLIC PIPING SYSTEMS, NEXT DRYDOCK IS DUE NO LATER THAN 31MAR93.
Condition: Unknown
Due 6 November 1992
Resolved 6 November 1992
Lifesaving
Issued 13 February 1992 Resolved
PATCH TEARS IN 8 PERSON LIFEFLOAT AND RENEW LIFELINE FOR LOWER LIFEFLOAT.
Condition: Unknown
Due 6 March 1992
Resolved 17 June 1992
Fire Fighting
Issued 13 February 1992 Resolved
MOUNT B-II FIRE EXTINGUISHER IN CABIN WITH PROPER, CG APPROVED, MOUNTING BRACKET.
Condition: Unknown
Due 6 March 1992
Resolved 17 June 1992
Lifesaving
Issued 13 February 1992 Resolved
REPLACE JIMBUOY 8 PERSON LIFEFLOAT 160.027/17/0 DUE TO DETERIORATION OF FOAM AND COVERING.
Condition: Unknown
Due 30 August 1992
Resolved 5 November 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.