MAURY USCG vessel records Sign in
← All vessels

BARU SATU

BARU SATU is a 2001 freight ship. The Coast Guard has recorded 30 inspections since 2001, most recently in February 2012, along with 8 deficiencies and 6 operational controls.

Records from 2001 to 2012. Most recent: inspection, 10 February 2012.

Built
2001
Last inspected
10 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9233624 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PHILIPPINES
—
Maury page id
psix-25546

Inspections, by type

…with no type recorded13
Years with a record 11 calendar years (2001–2012)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16190 - Dead Weight, Ton
20274 - Displacement, Ton
9978 - Convention (Subpart B), Gross Ton
5489 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ROLF WILLIAMS Tank Ship · MISLE 791668 · 19 July 2009 · activity 3540559

Inspection history · 30

10 February 2012 ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4239018
31 October 2010 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3881524
12 March 2010 NPV Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3691134
5 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3675918
27 January 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3670991
27 January 2010 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3672091
19 July 2009 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3540559
12 January 2009 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3392572
22 August 2008 Spot Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3305743
19 August 2008 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3303572
9 March 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3159181
25 February 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3150923
25 February 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3153181
15 January 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3129941
5 March 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2882854
5 October 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2794090
5 October 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2794387
1 August 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2448176
11 May 2005 ISPS III Exam · PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2354971
10 December 2004 NPV Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2256892
15 August 2004 ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2166523
14 August 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2165669
7 June 2004 Ballast Water Examination · Re-Inspection · MTSA/ISPS Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2091482
11 May 2004 Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2070262
30 March 2004 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2033887
9 August 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1870969
19 February 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1745911
15 February 2002 Ballast Water Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1483505
11 February 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1487841
19 June 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 291188

Deficiency record · 8

Engineering › Steering Gear System › Rudder Stock
Issued 22 August 2008 Resolved
Leak in rudder packing.
Action required: 705 - Other - as specified
Resolved 4 September 2008
Construction/Loadline › Markings › Load Line Mark
Issued 15 January 2008 Resolved
Make deck line port and starboard contrasting to dark background so deck line is plainly visible.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 25 February 2008
Resolution: Vessel''s load line was in contrasting colors.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 15 January 2008 Resolved
Hydrostatic Release units are expired on all liferafts. Replace all three Hydrostatic release units on port, starboard, and forward liferafts.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 25 February 2008
Resolution: Received class report stating that the vessel purchased new hydrostatic releases for life rafts.
Lifesaving › Emergency Outfit
Issued 30 March 2004 Resolved
Five of eight EEBD's were improperly charged. Vessel's captain had placed orders for replacements and his management had been advised of the deficiency. LEGACY COMPONENT DESC: Breathing Apparatus
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 March 2004
Resolved 1 April 2004
Resolution: Received fax from UNITOR atttesting that all EEBD''s have been serviced.
Pollution Prevention/Response › Prevention Equipment
Issued 19 February 2003 Resolved
BILGE VENT, PORTSIDE MAIN DECK NEEDS TO BE CONTAINED. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 March 2003
Resolved 24 February 2003
Resolution: RECEIVED REPORT FROM DOWALINE TECH ATTESTING TO THE INSTALLATION OF CONTAINMENT BOX.
Engineering › Steering Gear System › Rudder Bearing
Issued 19 February 2003 Resolved
STEERING GEAR RUDDER STOCK HAS TOO MUCH CLEARANCE WITHIN BEARINGS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2003
Resolved 20 February 2003
Resolution: RECEIVED CLASS REPORT ATTESTING TO SATISFACTORY CLASS INSPECTION OF RUDDER STOCK BEARINGS. BEARING CLEARANCE MEASUREMENTS FOUND TO BE WITHIN THE PARAMETERS FOR THE SHIP IN SERVICE.
Fire Fighting › Firemans Outfit › Gloves
Issued 19 February 2003 Resolved
FIREMAN OUTFIT GLOVES DO NOT MEET SOLAS REGULATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2003
Resolved 20 February 2003
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE PURCHASE OF PROPER GLOVES.
Navigation › Piloting/Steering
Issued 15 February 2002 Resolved
PROVIDE RECEIPT OF MISSING CHART NUMBER 12274. PRIOR TO DEPARTURE PORT OF BALTIMORE. 33CFR 164. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2002
Resolved 16 February 2002
Resolution: RECEIVED RECEIPT FOR NEW CHART.

Ownership record