Records from 2001 to 2004. Most recent: inspection, 15 September 2004.
Inspection history · 12
15 September 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2196811
27 May 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2085982
23 February 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2010631
12 February 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2005558
12 February 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2006184
11 February 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1999001
14 July 2003
Passenger/Freight Vessel Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1843108
14 July 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1845921
27 December 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1723459
17 November 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1708412
7 November 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1704353
5 September 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 293397
Engineering › Steering Gear System › Rudder
Issued 23 February 2004
No resolution recorded
Repair as original the steering system to the satisfaction of class prior to departure. SOLAS 74 amd I/11.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Steering Gear System
Issued 23 February 2004
Resolved
Install anti-vibration device in the steering system linkage arms to auto pilot. LEGACY COMPONENT DESC: Linkage
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2004
Resolution: Received class report verifying repairs.
Pollution Prevention/Response › Prevention Equipment
Issued 23 February 2004
Resolved
Provide approval of the oily water separating equipment where a cross connection has been installed bypassing the 3-way valve and a soft patch plug is installed on a branch line. MARPOL 73/78 I. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2004
Resolution: Received class report verifying approval by class.
Navigation › Collision/Grounding Avoidance
Issued 11 February 2004
Resolved
Provide continuous recorder for depth sounding device IAW 33 CFR 164.35(i) to satisfaction of USCG Inspector. LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Due 11 March 2004
Resolved 23 February 2004
Resolution: A sufficient electronic continuous recorder is incorporated into the existing depth sounding device.
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2004
Resolved
Prove proper operation of auto closure device on category A fire door IAW SOLAS 74/78 CH II-2 Reg 47.1 (located on 01 poop deck at the entrance to galley) to the satisfaction of USCG Inspector. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 11 March 2004
Resolved 23 February 2004
Resolution: Witnessed proper operation of auto closure device.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 14 July 2003
Resolved
Install hydrostatic release unit properly with weak link attached to the vessel on port side liferaft. (Weak link on the wrong side of the release)
Due 14 July 2003
Resolved 14 July 2003
Resolution: Release unit installed properly.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 July 2003
Resolved
Containment plugs need to be made readily available. (Plugs were stored in the engine room)
Due 14 July 2003
Resolved 14 July 2003
Resolution: Plug to be attached to a chain to the containment for accessibility
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 July 2003
Resolved
Reattach self closing device and remove hold back devices to firedoors in the engine room. (bungee cords holding doors open to emergency escape trunks)
Due 14 July 2003
Resolved 14 July 2003
Resolution: Device reconnected and holdbacks removed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 November 2002
Resolved
Engine crankcase exhaust is blowing oil through the exhaust vent adjacent to the battery room aft of the pilothouse - there is oil accumulation on deck below the exhaust vent. Oil blow-by is likely related to further maintenece problems with the main engine. LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 November 2002
Resolved
Audible alarm on OWS unit did not sound during test of 15 ppm content meter. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 November 2002
Resolved
A small copper sampling pipe and petcock had been installed appx 2 feet from the overboard discharge valve on the OWS. Engineer claimed that he used the sampling pipe to "make sure" oil didn't go overboard because the automatic shutoff had failed previously and allow sludge to reach the ovbd disch. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 November 2002
Resolved
Housekeeping in engine room is substandard. Drip trays, machinery pumps need to be wiped down. Change-over valve on HFO day tank is dripping HFO from overhead. Leaks need to be addressed and 5 gallon temporary drip cans removed.
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Navigation › Collision/Grounding Avoidance
Issued 17 November 2002
Resolved
Fathometer has no continuous recording device. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Lifesaving
Issued 5 September 2001
Resolved
Prove proper operation of the free fall lifeboat engine to the attending U.S. Coast Guard Marine Inspector prior to departing the port of Honolulu IAW SOLAS Chapter III Regulation 20.2.
Condition: Unknown
Due 8 October 2001
Resolved 8 October 2001
Navigation
Issued 5 September 2001
Resolved
Repair and test steering gear to the satisfaction of class prior to next U.S. port.
Condition: Unknown
Due 8 October 2001
Resolved 8 October 2001
Lifesaving
Issued 5 September 2001
Resolved
Repair starboard rail on main deck to the satisfaction of class prior to next U.S. port IAW ICLL Annex I Regulation 25.
Condition: Unknown
Due 5 September 2001
Resolved 7 November 2002
Resolution: Recieved fax from master stating that the starboard railing has been repaired.