MAURY USCG vessel records Sign in
← All vessels

BBC CHINA

BBC CHINA is a 2001 freight ship. The Coast Guard has recorded 12 inspections since 2001, most recently in September 2004, along with 16 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 2001 to 2004. Most recent: inspection, 15 September 2004.

Built
2001
Last inspected
15 September 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9219082 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-25548

Inspections, by type

…with no type recorded5
Years with a record 4 calendar years (2001–2004)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5548 - Convention (Subpart B), Gross Ton
5548 - Regulatory (Subpart C or D), Gross Ton
3020 - Convention (Subpart B), Net Ton
3020 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

15 September 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2196811
27 May 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2085982
23 February 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2010631
12 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2005558
12 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2006184
11 February 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1999001
14 July 2003 Passenger/Freight Vessel Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1843108
14 July 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1845921
27 December 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1723459
17 November 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1708412
7 November 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1704353
5 September 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 293397

Deficiency record · 16

Engineering › Steering Gear System › Rudder
Issued 23 February 2004 No resolution recorded
Repair as original the steering system to the satisfaction of class prior to departure. SOLAS 74 amd I/11.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Steering Gear System
Issued 23 February 2004 Resolved
Install anti-vibration device in the steering system linkage arms to auto pilot. LEGACY COMPONENT DESC: Linkage
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2004
Resolution: Received class report verifying repairs.
Pollution Prevention/Response › Prevention Equipment
Issued 23 February 2004 Resolved
Provide approval of the oily water separating equipment where a cross connection has been installed bypassing the 3-way valve and a soft patch plug is installed on a branch line. MARPOL 73/78 I. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2004
Resolution: Received class report verifying approval by class.
Navigation › Collision/Grounding Avoidance
Issued 11 February 2004 Resolved
Provide continuous recorder for depth sounding device IAW 33 CFR 164.35(i) to satisfaction of USCG Inspector. LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Due 11 March 2004
Resolved 23 February 2004
Resolution: A sufficient electronic continuous recorder is incorporated into the existing depth sounding device.
Fire Fighting › Structural - A Class Divisions
Issued 11 February 2004 Resolved
Prove proper operation of auto closure device on category A fire door IAW SOLAS 74/78 CH II-2 Reg 47.1 (located on 01 poop deck at the entrance to galley) to the satisfaction of USCG Inspector. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 11 March 2004
Resolved 23 February 2004
Resolution: Witnessed proper operation of auto closure device.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 14 July 2003 Resolved
Install hydrostatic release unit properly with weak link attached to the vessel on port side liferaft. (Weak link on the wrong side of the release)
Due 14 July 2003
Resolved 14 July 2003
Resolution: Release unit installed properly.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 July 2003 Resolved
Containment plugs need to be made readily available. (Plugs were stored in the engine room)
Due 14 July 2003
Resolved 14 July 2003
Resolution: Plug to be attached to a chain to the containment for accessibility
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 July 2003 Resolved
Reattach self closing device and remove hold back devices to firedoors in the engine room. (bungee cords holding doors open to emergency escape trunks)
Due 14 July 2003
Resolved 14 July 2003
Resolution: Device reconnected and holdbacks removed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 November 2002 Resolved
Engine crankcase exhaust is blowing oil through the exhaust vent adjacent to the battery room aft of the pilothouse - there is oil accumulation on deck below the exhaust vent. Oil blow-by is likely related to further maintenece problems with the main engine. LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 November 2002 Resolved
Audible alarm on OWS unit did not sound during test of 15 ppm content meter. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 November 2002 Resolved
A small copper sampling pipe and petcock had been installed appx 2 feet from the overboard discharge valve on the OWS. Engineer claimed that he used the sampling pipe to "make sure" oil didn't go overboard because the automatic shutoff had failed previously and allow sludge to reach the ovbd disch. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 17 November 2002 Resolved
Housekeeping in engine room is substandard. Drip trays, machinery pumps need to be wiped down. Change-over valve on HFO day tank is dripping HFO from overhead. Leaks need to be addressed and 5 gallon temporary drip cans removed.
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Navigation › Collision/Grounding Avoidance
Issued 17 November 2002 Resolved
Fathometer has no continuous recording device. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 705 - Other - as specified
Due 17 December 2002
Resolved 27 December 2002
Lifesaving
Issued 5 September 2001 Resolved
Prove proper operation of the free fall lifeboat engine to the attending U.S. Coast Guard Marine Inspector prior to departing the port of Honolulu IAW SOLAS Chapter III Regulation 20.2.
Condition: Unknown
Due 8 October 2001
Resolved 8 October 2001
Navigation
Issued 5 September 2001 Resolved
Repair and test steering gear to the satisfaction of class prior to next U.S. port.
Condition: Unknown
Due 8 October 2001
Resolved 8 October 2001
Lifesaving
Issued 5 September 2001 Resolved
Repair starboard rail on main deck to the satisfaction of class prior to next U.S. port IAW ICLL Annex I Regulation 25.
Condition: Unknown
Due 5 September 2001
Resolved 7 November 2002
Resolution: Recieved fax from master stating that the starboard railing has been repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.