Records from 2001 to 2012. Most recent: inspection, 26 January 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
26 January 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4231970
10 September 2010
ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3846994
17 March 2009
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3434934
5 August 2008
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3283169
10 June 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3232646
9 May 2008
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3202453
9 February 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3144582
26 September 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3066438
30 January 2007
MARPOL Annex V Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2863809
26 September 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2786968
6 June 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2617063
23 September 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2499372
18 December 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2261664
8 October 2004
ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2216396
7 October 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2216051
4 August 2004
ISPS II Exam · NPV Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2155622
2 July 2003
Passenger/Freight Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1832918
18 April 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1776134
24 June 2002
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1635678
20 June 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1632498
23 April 2001
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 289270
19 April 2001
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 289230
Engineering › Compressed Air System (start air) › Compressor
Issued 17 March 2009
Resolved
Vessel reported a broken start air compressor. Class to Determine cause of failure and attest to proper operation prior to departure. 74SOLAS(04 cons) Ch.I Reg.II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2009
Resolution: Received class report attesting to proper repairs and function of start air compressor. Def. cleared.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 17 March 2009
Resolved
Vessel reported a crack in strengthening plate inside hold number 1. Make repairs to the satisfaction of Class prior to departure. 74SOLAS( 04 cons) Ch.I Reg II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2009
Resolution: Received class report attesting to the repairs of the number 1 hold. Def. cleared.
Deck/Cargo › Cargo Stowage › General
Issued 9 May 2008
Resolved
The coaming supports for the hatch cover speed locks were found to be cracked in the mid-ship area on the port and starboard sides. Class to attest to the integrity of the coamings in the vicinity of the speed locks. ILLC 66 Reg 16
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2008
Resolution: Recieved class report attesting to the repair of the cracks.
Construction/Loadline › Markings › Load Line Mark
Issued 9 May 2008
Resolved
The loadline markings on the vessels hull do not correspond with the vessel's loadline certificate. The certificate show's the markings as TF,F,T,S and W. The lines found on the vessel are TZW,ZW,T,Z, WWNA. Class to attest to the proper markings. ILLC 66 Annex I Reg 6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2008
Resolution: Class report attesting to the improper loadline marks being removed has be received
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 9 May 2008
Resolved
The vessel's Cargo Ship Safety Cert (CSSC) does not indicate the vessel is equipped with an echo depth sounder. Class to attest to the proper marking of the CSSC in regards to the installed equipment on board. SOLAS I/12(a)(V)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2008
Resolution: Received a class report attesting to the new issue of a CSSC equipment form C.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 September 2007
Resolved
Vessel is missing non-slip matting or surface in steering room. Vessel will order matting in next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 February 2008
Resolution: Vessel''s agent faxed proof of purchase of non-slip matting from vessel. Deficiency cleared.
Operations/Management › Equipment Service/Testing
Issued 20 June 2002
Resolved
Vessel failed to conduct required pre-arrival test(s) before entering U.S. navigable waters. Next U.S. port to verify compliance with the same.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 June 2002
Resolution: Verified that vessel conducted the required pre-arrival test(s) IAW 33CFR164.25. Vessel in compliance.