← All vessels
CELTIC
Commercial Fishing Vessel · Fishing Vessel class · Built 1960s · USCG Northwest District (CGD-NW) · Other hulls named CELTIC
CELTIC is a 1968 commercial fishing vessel. The Coast Guard has recorded 25 inspections since 1986, most recently in January 2023, along with 16 deficiencies and 1 casualty investigation in 2023.
Records from 1986 to 2023. Most recent: inspection, 19 January 2023.
- Built
- 1968
- Last inspected
- 19 January 2023
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
687681
WDL3090
256320
Flag
UNITED STATES
367387370
Maury page id
psix-256320
Inspections, by type
…with no type recorded7
Years with a record
15 calendar years (1986–2023)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 17.0 ft × 5.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGUNDERSON BROTHERS ENGINEERING CORP · PORTLAND, OR, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWESTPORT, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 1 June 2026 · expires 30 June 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL3090MMSI 367387370 · active · voluntarily equipped · granted 24 October 2019, expires 24 October 2029
WDE6984MMSI 367387370 · expired · voluntarily equipped · granted 10 December 2008, cancelled 16 February 2019
WSC6391MMSI not assigned · expired · compulsorily equipped · granted 3 February 1997, cancelled 3 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 25
19 January 2023
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 7625994
19 January 2023
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7627394
9 January 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3391325
8 December 2008
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 3377330
10 June 1997
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1110095
24 April 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1398517
21 April 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387822
12 April 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387821
28 April 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396175
2 November 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396176
15 April 1993
Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132501
5 May 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956784
15 April 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1258314
25 June 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230463
24 June 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214612
4 June 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1231238
2 May 1991
Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223248
15 May 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900795
26 April 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230019
2 April 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 905564
17 April 1989
Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044246
11 May 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1349656
19 April 1988
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343719
12 May 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1334805
14 May 1986
Initial Certification · Credit Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297728
Deficiency record · 16
Construction/Loadline
Issued 15 April 1993
Resolved
MAKE REPAIRS TO ALL DAMAGED INTERIOR BULKHEADS IN WAY OF SIDESHELL BOTH SIDES. MAKE A PROPER REPAIR TO: (1) HOLED SIDE SHELL BENEATH DOUBLER PLATING LOCATED PORT SIDE IN FOREPEAK, (2) CRACKED AREA STBD SIDE OF E/R, REPAIR IMPROPER INSERTS. REPAIRS TO BE ACCOMPLISHED OVER NEXT SEVERAL DDX'S
Documentation
Issued 15 April 1992
Resolved
PROVIDE A CURRENT COMPASS DEVIATION CARD.
Lifesaving
Issued 15 April 1992
Resolved
SUBMIT TO OCMI FOR APPROVAL, A MAN OVERBOARD RECOVERY SYSTEM.
Engineering
Issued 15 April 1992
Resolved
INSTALL PULLEY GUARD ON PORT ENGINE ALTERNATOR PULLEY.
Documentation
Issued 15 April 1992
Resolved
POST VESSEL'S DRUG TESTING POLICY.
Engineering
Issued 2 May 1991
Resolved
INSTALL FLAME ARRESTOR BOWLS FOR RACOR FUEL FILTERS.
Documentation
Issued 2 May 1991
Resolved
PROVIDE HULL GAUGING REPORT TO MSO SAN FRANCISCO BAY.
Fire Fighting
Issued 2 May 1991
Resolved
REMOVE NON COAST GUARD APPROVED FIXED HALON FIRE EXTINGUISHING SYSTEM FROM THE VESSEL.
Electrical
Issued 2 May 1991
Resolved
INSTALL VAPOR PROOF LIGHTING FIXTURES WITH GUARDS IN ENGINEROOM.
Accommodation/Occupational Safety
Issued 2 May 1991
Resolved
EXTEND ONE ENGINEROOM VENT DUCT TO AS CLOSE AS PRACTICAL TO THE BILGE.
Documentation
Issued 2 May 1991
Resolved
PROVIDE DOCUMENTATION OF ENROLLMENT IN A DRUG TESTING PROGRAM.
Fire Fighting
Issued 2 April 1990
Resolved
HAVE 15 LB CO2 BOTTLE HYDROSTATICALLY TESTED.
Engineering
Issued 19 April 1988
Resolved
CONDUCTED UNDERWAY TEST OF PROPULSION ENGINES, TRANSMISSIONS, AND STEERING SYSTEM. ALSO TEST ENGINE DRIVEN BILGE PUMP.
Electrical
Issued 12 May 1987
Resolved
INSTALL PROTENTIVE BASKETS/COVERS OVER EXPOSED LIGHT BULBS IN INTERNAL COMPARTMENTS.
Documentation
Issued 12 May 1987
Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Construction/Loadline
Issued 12 May 1987
Resolved
INSTALL KEEPER CHAIN TO HATCH COVER FOR LAZARETTE COMPARTMENT.
Casualty record · 1
19 January 2023Routine · role: Involved in a Marine Casualty · activity 7627394
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National