MAURY USCG vessel records Sign in
← All vessels

CELTIC

CELTIC is a 1968 commercial fishing vessel. The Coast Guard has recorded 25 inspections since 1986, most recently in January 2023, along with 16 deficiencies and 1 casualty investigation in 2023.

Records from 1986 to 2023. Most recent: inspection, 19 January 2023.

Built
1968
Last inspected
19 January 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL3090
256320
Flag
UNITED STATES
367387370
Maury page id
psix-256320

Inspections, by type

…with no type recorded7
Years with a record 15 calendar years (1986–2023)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 17.0 ft × 5.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGUNDERSON BROTHERS ENGINEERING CORP · PORTLAND, OR, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWESTPORT, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 1 June 2026 · expires 30 June 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL3090MMSI 367387370 · active · voluntarily equipped · granted 24 October 2019, expires 24 October 2029
WDE6984MMSI 367387370 · expired · voluntarily equipped · granted 10 December 2008, cancelled 16 February 2019
WSC6391MMSI not assigned · expired · compulsorily equipped · granted 3 February 1997, cancelled 3 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 25

19 January 2023 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 7625994
19 January 2023 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7627394
9 January 2009 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3391325
8 December 2008 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 3377330
10 June 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1110095
24 April 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1398517
21 April 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387822
12 April 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387821
28 April 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396175
2 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396176
15 April 1993 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132501
5 May 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956784
15 April 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1258314
25 June 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230463
24 June 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214612
4 June 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1231238
2 May 1991 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223248
15 May 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900795
26 April 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230019
2 April 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 905564
17 April 1989 Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044246
11 May 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1349656
19 April 1988 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343719
12 May 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1334805
14 May 1986 Initial Certification · Credit Drydock
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297728

Deficiency record · 16

Construction/Loadline
Issued 15 April 1993 Resolved
MAKE REPAIRS TO ALL DAMAGED INTERIOR BULKHEADS IN WAY OF SIDESHELL BOTH SIDES. MAKE A PROPER REPAIR TO: (1) HOLED SIDE SHELL BENEATH DOUBLER PLATING LOCATED PORT SIDE IN FOREPEAK, (2) CRACKED AREA STBD SIDE OF E/R, REPAIR IMPROPER INSERTS. REPAIRS TO BE ACCOMPLISHED OVER NEXT SEVERAL DDX'S
Condition: Unknown
Due 30 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 15 April 1992 Resolved
PROVIDE A CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 15 April 1992 Resolved
SUBMIT TO OCMI FOR APPROVAL, A MAN OVERBOARD RECOVERY SYSTEM.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Engineering
Issued 15 April 1992 Resolved
INSTALL PULLEY GUARD ON PORT ENGINE ALTERNATOR PULLEY.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Documentation
Issued 15 April 1992 Resolved
POST VESSEL'S DRUG TESTING POLICY.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Engineering
Issued 2 May 1991 Resolved
INSTALL FLAME ARRESTOR BOWLS FOR RACOR FUEL FILTERS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Documentation
Issued 2 May 1991 Resolved
PROVIDE HULL GAUGING REPORT TO MSO SAN FRANCISCO BAY.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Fire Fighting
Issued 2 May 1991 Resolved
REMOVE NON COAST GUARD APPROVED FIXED HALON FIRE EXTINGUISHING SYSTEM FROM THE VESSEL.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 May 1991 Resolved
INSTALL VAPOR PROOF LIGHTING FIXTURES WITH GUARDS IN ENGINEROOM.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Accommodation/Occupational Safety
Issued 2 May 1991 Resolved
EXTEND ONE ENGINEROOM VENT DUCT TO AS CLOSE AS PRACTICAL TO THE BILGE.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Documentation
Issued 2 May 1991 Resolved
PROVIDE DOCUMENTATION OF ENROLLMENT IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Fire Fighting
Issued 2 April 1990 Resolved
HAVE 15 LB CO2 BOTTLE HYDROSTATICALLY TESTED.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Engineering
Issued 19 April 1988 Resolved
CONDUCTED UNDERWAY TEST OF PROPULSION ENGINES, TRANSMISSIONS, AND STEERING SYSTEM. ALSO TEST ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Electrical
Issued 12 May 1987 Resolved
INSTALL PROTENTIVE BASKETS/COVERS OVER EXPOSED LIGHT BULBS IN INTERNAL COMPARTMENTS.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Documentation
Issued 12 May 1987 Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Construction/Loadline
Issued 12 May 1987 Resolved
INSTALL KEEPER CHAIN TO HATCH COVER FOR LAZARETTE COMPARTMENT.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987

Casualty record · 1

19 January 2023Routine · role: Involved in a Marine Casualty · activity 7627394
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.