MAURY USCG vessel records Sign in
← All vessels

MISS GRACIE

MISS GRACIE is a 2001 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2001, most recently in February 2025, along with 28 deficiencies and 1 casualty investigation in 2021.

Records from 2001 to 2025. Most recent: inspection, 11 February 2025.

Built
2001
Last inspected
11 February 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968428 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
369015000 (licence lapsed)
Maury page id
psix-25645

Inspections, by type

…with no type recorded5
Years with a record 20 calendar years (2001–2025)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)148.2 ft × 30.0 ft × 12.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)148.2 ft × 30.0 ft × 12.1 ft
ITC tonnagegross 350 / net 105
BuilderSWIFTSHIPS SHIPBLD LLC · MORGAN CITY LA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
350 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
105 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAFEMMSI 369015000 · cancelled · compulsorily equipped · granted 24 November 2021, cancelled 20 August 2026
WAFEMMSI 369015000 · expired · compulsorily equipped · granted 21 June 2011, cancelled 21 August 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 35

11 February 2025 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8085932
19 December 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7840695
5 January 2023 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7616844
1 November 2022 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7587908
6 December 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7363544
15 May 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7199486
15 May 2021 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7201329
6 October 2020 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7073802
15 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6836080
11 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6537683
20 August 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6517815
26 July 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6221486
21 June 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914363
3 June 2014 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4879108
11 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4375310
19 January 2012 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4227985
2 August 2011 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4103104
9 April 2008 Administrative Inspection · Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3180819
16 June 2007 Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2963467
15 March 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2602826
6 March 2006 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2595553
17 January 2006 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2568149
17 January 2006 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2568299
9 September 2005 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2488392
28 July 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2443236
19 July 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2431824
18 July 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2431471
3 June 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2377847
28 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2064725
27 April 2004 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2053541
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1973510
2 July 2003 Annual Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1833131
26 August 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1666718
21 June 2001 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433858
26 April 2001 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433857

Deficiency record · 28

09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 19 December 2023 Resolved
Sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Add sea rails to the oven. 46 CFR 184.220(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: Rails added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 19 December 2023 Resolved
Inspection of all railings and bulwarks and their attachment to the hull structure. One stanchion post on the deck has a hole causing a leak into the vessel. Repair as original. 46 CFR 176.802(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: Hole repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Exhaust piping on port engine needs to be suitable insulated. 46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: Exhaust lagging replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2023 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Hoses from each engine to the oil pressure gauges were approximately 15 feet of USCG A-1 J-1527 hoses. Replace hoses to gauges with SAE J-1942 hoses. 46 CFR 182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2024
Resolved 3 January 2024
Resolution: Hoses replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 December 2023 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bolts on engine room supply vent trunks used as maintenance openings located on the port and starboard side of the generator room found missing to allow increased air flow to the engine room. However, this provides a direct opening from the engine room to the generator space which is a watertight bulkhead. 46 CFR 179.320(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2024
Resolution: Access cover secured.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 January 2023 Resolved
The smoke detectors in the accomadation areas did not meet the UL standard. Vessel to replace all independent smoke detectors to the correct type.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2023
Resolution: Replaced smoke detectors with the correct type.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 5 January 2023 Resolved
The ventalation closing plates on the main deck for the machinery spaces below could not be secured. Vessel to repair the hardware on the vents to allow for securing of the ventailation closure plates.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 13 January 2023
Resolution: Corrected by using appropriate sized bolts & wing nuts, rewelding the tabs on the plates to match up with the securing bolts.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 5 January 2023 Resolved
Two tanks in the fwd machinery space that contained flamable liquids had plastic sight glasses. Replace with a suitable heat resistant type of sight glass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 13 January 2023
Resolution: Corrected with a glass tube and tack welded alluminum flat bar on either side of the sight glass to avoid accidental breakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2021 Resolved
Exhaust gas must not leak from the piping or any connections. Make permanent repairs to crack on starboard generator exhaust piping where it meets the hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 9 December 2021
Resolution: Repaired exhaust piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 December 2021 Resolved
A hatch cover must: Have securing decives. Replace securing device on fore-peak hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 9 December 2021
Resolution: Replaced securing device on fore-peak hatch cover.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 26 July 2017 Resolved
Anchor winch inoperable.
Condition: Improper/Lack of Maintenance
Due 2 August 2017
Resolved 27 July 2017
Electrical › Electric Generation Source (service) › Generator
Issued 26 July 2017 Resolved
Generator Started back up automatically after shutdown after CO2 operational test.
Condition: Improper Installation
Due 2 August 2017
Resolved 27 July 2017
Documentation › Certificates/Documents › Stability Letter
Issued 11 July 2012 Resolved
The vessel shall reduce the max deck cargo weight, to comply with the new assumed average weight per person standards.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 July 2012
Resolution: Vessel issued stability letter for new deck cargo weight carrying capacity IAW MSC letter H1-1203297.
Stability › Watertight Integrity › General
Issued 9 April 2008 Resolved
Fix hole drilled into the E/R bulkhead to run an extension cord through.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Stability › Watertight Integrity › General
Issued 9 April 2008 Resolved
E/R ventilation access panels have no gaskets to make them watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Engineering › Fuel Oil Service System › Hose
Issued 9 April 2008 Resolved
#2 MDE fuel line is leaking.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Communications › Radio Communications › EPIRB
Issued 9 April 2008 Resolved
Hydro release out of date.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 April 2008 Resolved
Bilge alarm for rudder room not working.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 9 April 2008 Resolved
Smoke alarms had no batteries installed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Construction/Loadline › Structures › Scuttle
Issued 9 April 2008 Resolved
Emergency escape ladder needs the broken step replaced.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 16 June 2007 Resolved
Substancial cracking in the starboard generator exhaust IWO the side shell. Previous weld repairs had been completed on the area but were insufficient. Required area to be cropped and renewed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2007
Lifesaving
Issued 2 July 2003 Resolved
Provide Coast Guard approved hydrostatic release for EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 28 July 2003
Lifesaving › Liferaft Equipment
Issued 2 July 2003 Resolved
Provide liferaft capacity for total persons allowed onboard vessel. Ensure rafts have been inspected at a Coast Guard approved facility and have the proper sticker attached.
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 28 July 2003
Navigation › Piloting/Steering › Marine Charts
Issued 2 July 2003 Resolved
Provide corrected charts for operating area.
Due 13 August 2003
Resolved 16 July 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 July 2003 Resolved
Provide tidal current, light list, and Coast Pilot for vessels operating area.
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 28 July 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 2 July 2003 Resolved
Provide Coast Guard approved fire extinguishers for vessels allowance. LEGACY COMPONENT DESC: Number
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 28 July 2003
Lifesaving
Issued 2 July 2003 Resolved
Provide hydrostatic releases for all life rafts.
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 28 July 2003
Documentation › Certificates/Documents
Issued 2 July 2003 Resolved
Provide current certificate of documentation.
Action required: 705 - Other - as specified
Due 13 August 2003
Resolved 28 July 2003

Casualty record · 1

15 May 2021Routine · role: Involved in a Marine Casualty · activity 7199486
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.