MAURY USCG vessel records
← All vessels

MISS GRACIE

Built
2001
Last inspected
11 February 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 February 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8968428
Flag
UNITED STATES
Maury page id
psix-25645

Documentation record

Registered dimensions (L × B × D)148.2 ft × 30.0 ft × 12.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)148.2 ft × 30.0 ft × 12.1 ft
ITC tonnagegross 350 / net 105
BuilderSWIFTSHIPS SHIPBLD LLC · MORGAN CITY LA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 12 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
350 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
105 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

11 February 2025 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8085932
19 December 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7840695
5 January 2023 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7616844
1 November 2022 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7587908
6 December 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7363544
15 May 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7199486
15 May 2021 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7201329
6 October 2020 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7073802
15 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6836080
11 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6537683
20 August 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6517815
26 July 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6221486
21 June 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5914363

Deficiency record · 12

09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 19 December 2023 Resolved
Sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Add sea rails to the oven. 46 CFR 184.220(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: Rails added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 19 December 2023 Resolved
Inspection of all railings and bulwarks and their attachment to the hull structure. One stanchion post on the deck has a hole causing a leak into the vessel. Repair as original. 46 CFR 176.802(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: Hole repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Exhaust piping on port engine needs to be suitable insulated. 46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: Exhaust lagging replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2023 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Hoses from each engine to the oil pressure gauges were approximately 15 feet of USCG A-1 J-1527 hoses. Replace hoses to gauges with SAE J-1942 hoses. 46 CFR 182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2024
Resolved 3 January 2024
Resolution: Hoses replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 December 2023 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bolts on engine room supply vent trunks used as maintenance openings located on the port and starboard side of the generator room found missing to allow increased air flow to the engine room. However, this provides a direct opening from the engine room to the generator space which is a watertight bulkhead. 46 CFR 179.320(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2024
Resolution: Access cover secured.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 January 2023 Resolved
The smoke detectors in the accomadation areas did not meet the UL standard. Vessel to replace all independent smoke detectors to the correct type.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2023
Resolution: Replaced smoke detectors with the correct type.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 5 January 2023 Resolved
The ventalation closing plates on the main deck for the machinery spaces below could not be secured. Vessel to repair the hardware on the vents to allow for securing of the ventailation closure plates.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 13 January 2023
Resolution: Corrected by using appropriate sized bolts & wing nuts, rewelding the tabs on the plates to match up with the securing bolts.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 5 January 2023 Resolved
Two tanks in the fwd machinery space that contained flamable liquids had plastic sight glasses. Replace with a suitable heat resistant type of sight glass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 13 January 2023
Resolution: Corrected with a glass tube and tack welded alluminum flat bar on either side of the sight glass to avoid accidental breakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2021 Resolved
Exhaust gas must not leak from the piping or any connections. Make permanent repairs to crack on starboard generator exhaust piping where it meets the hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 9 December 2021
Resolution: Repaired exhaust piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 December 2021 Resolved
A hatch cover must: Have securing decives. Replace securing device on fore-peak hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2022
Resolved 9 December 2021
Resolution: Replaced securing device on fore-peak hatch cover.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 26 July 2017 Resolved
Anchor winch inoperable.
Condition: Improper/Lack of Maintenance
Due 2 August 2017
Resolved 27 July 2017
Electrical › Electric Generation Source (service) › Generator
Issued 26 July 2017 Resolved
Generator Started back up automatically after shutdown after CO2 operational test.
Condition: Improper Installation
Due 2 August 2017
Resolved 27 July 2017