SEA EAGLE

SEA EAGLE is a 1984 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1984, most recently in March 2026, along with 96 deficiencies and 9 casualty investigations between 2005 and 2013.

Records from 1984 to 2026. Most recent: inspection, 23 March 2026.

Built
1984
Last inspected
23 March 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ7950
256679
Flag
UNITED STATES
368011670
Maury page id
psix-256679

Inspections, by type

…with no type recorded14
Years with a record 38 calendar years (1984–2026)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 15.5 ft × 6.6 ft
Registered tonnagegross 37 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · PORT EVERGLADES FL, UNITED STATES · built 1984
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Net Ton
37 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7950MMSI 368011670 · active · compulsorily equipped · granted 2 November 2017, expires 2 November 2027
WDC7691MMSI 367075260 · expired · compulsorily equipped · granted 5 November 2005, cancelled 9 January 2016
WAK4951MMSI not assigned · expired · compulsorily equipped · granted 7 February 1995, cancelled 18 October 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

23 March 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8319644
23 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8117903
26 February 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8086213
29 February 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7872252
22 February 2023 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7640599
5 December 2022 DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7601805
24 March 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7418093
2 March 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7382544
23 September 2021 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7318608
16 February 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7141106
14 January 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6887232
29 October 2019 Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6848610
7 January 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6606729
8 August 2017 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6235412
25 May 2017 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6155396
26 March 2014 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4823370
13 July 2012 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4377547
3 July 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4367236
2 July 2012 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 4365748
13 February 2012 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4243197
6 February 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4239863
1 February 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4239423
10 March 2010 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3693372
8 March 2010 Type not recorded
No type recorded · USCGC NANTUCKET (WPB 1316) - Port · USCG Southeast District (CGD-SE) · Activity 3706589
29 December 2009 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3656381
17 December 2009 DAPI Audit · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3652049
19 February 2009 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3423156
3 February 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3411560
27 May 2008 Hull Examination · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3219240
6 February 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3142720
2 January 2008 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3127239
13 February 2007 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2871409
13 October 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2800060
6 April 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2618549
23 February 2006 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2590741
6 February 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2579769
29 April 2005 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2345838
9 March 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2305721
5 October 2004 Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2213184
10 May 2004 Administrative Inspection
Administrative · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2063710
11 February 2004 Deficiency Check · Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2007991
27 May 2003 Damage Survey
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1838194
25 May 2003 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1802604
3 April 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1768315
11 February 2003 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1741312
30 January 2003 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1740888
29 January 2003 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1807619
20 February 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1486297
22 January 2002 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1480119
15 May 2001 Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1454946
18 January 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401406
7 March 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415324
24 February 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1470502
8 December 1998 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381424
13 February 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777620
4 March 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 774597
20 February 1997 Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1105410
11 March 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885202
26 April 1995 Hull Examination · Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1169662
20 April 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 137914
18 April 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 853363
14 March 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 860720
7 March 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 855237
19 October 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 830074
10 March 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1150623
3 June 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261225
11 May 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1265946
3 February 1992 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 950558
30 April 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 998632
1 April 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 909128
14 May 1990 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949411
13 March 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1259915
13 March 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1263341
3 August 1989 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1243469
22 February 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1043351
19 May 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040711
13 March 1987 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005349
25 April 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306492
23 April 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 998733
12 November 1985 Credit Drydock · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299244
20 March 1984 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306489

Deficiency record · 96

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 April 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Port side fuel shutoff valve does not close completely due to cable loop getting caught in eye bolt. Additionally, starboard valve handle is broken and does not stop at the fully closed/open positions. Repair shutoff valves to satisfaction of MI. 46 CFR 182.20-40 (b)(3) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 6 May 2025
Resolution: Verified new starboard side fuel shutoff valve was installed and can fully open and close, as well as port side fuel shutoff valve cable loop was fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Lighting wire for aft deck found disconnected and open. Repair/replace to satisfaction of MI. 46 CFR 183.01-15 (a) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 6 May 2025
Resolution: Verified lighting wiring on aft deck was reconnected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 April 2025 Resolved
A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Cabin compartment electronic submersible pump was inoperable. Repair/replace to satisfaction of MI. 46 CFR 182.520(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 6 May 2025
Resolution: Verified forward cabin space ESP is now operable. Breaker was off previously.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 February 2024 Resolved
Fuel shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines. Discovered port side fuel shutoff unable to fully close due to pull cable crimp getting caught in eye bolt. Repair/replace pull cable to allow valve to fully close.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2024
Resolution: O/O Provided picture of cable crimp for fuel shut off.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 February 2024 Resolved
The power fire pump shall be self priming and of such size as to discharge an effective stream from a hose connected to the outlet. Fire pump was unable to produce stream of water to fire hoses. O/O provided video showing fire pump working properly after MI's departed the vessel. Ice was built up in the discharge line blocking the stream of water.
Action required: 10 - Deficiency Rectified
Resolved 29 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 February 2024 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Discovered cotter pins on steering ram assembly to be severely corroded. Replace corroded cotter pins on steering ram assembly. 46 CFR 182.30-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 6 March 2024
Resolution: O/O provided picture of new cotter pins
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 February 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be replaced if the expiration date has passed. Found three floating water lights with expired batteries. Replace floating water light batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 6 March 2024
Resolution: O/O Provided picture of newly purchased float light batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 February 2024 Resolved
All electrical installations shall be to the satisfaction of the officer in charge, marine inspection. Found several dead end electrical wires behind console in pilot house. Remove any old/unused wires & cap/secure remaining electrical wires under console. 46 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 6 March 2024
Resolution: O/O provided pictures of electrical wires secured/capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2022 Resolved
Flexible nonmetallic hose must meet SAE J1942 and have factory end fittings that meet SAE 1475. Diesel supply hose for starboard engine is hose clamped to its end fittings and has no visible markings showing what standard the hose meets. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 15 December 2022
Resolution: Replacement hose is a Parker 221FR-8. Listed as equivalent to SAE J1942.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 December 2022 Resolved
Remove all zip ties that from the life float, especially those used for coiling the painter and pendants. CORRECTED ON THE SPOT. 46 CFR 180.130(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2022
Resolution: Corrected on the spot.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 2 March 2022 Resolved
Vessel's sewage overboard valve was not properly secured. Install proper securing device to sewage overboard valve. 33CFR159.7(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 24 March 2022
Resolution: USCG satisfied with picture sent from [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022 Resolved
Vessel unable to provide annual servicing report for portable fire extinguishers. Provide Marine Inspector servicing report attesting that the annual maintenance was carried out for all portable extinguishers. 46CFR176.810(b)(1)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 25 March 2022
Resolution: USCG satisfied with picture provided by [name withheld] to clear the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2022 Resolved
Vessel only had 01 donning instructions posted and has 03 different life jacket models requiring different donning instructions. Acquire and post donning instructions for all life jacket models carried on board. 46CFR185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 24 March 2022
Resolution: USCG satisfied with pictures that [name withheld] provided
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 March 2022 Resolved
01 light in the machinery space and lazarette are missing lenses. 01 light in the machinery space is missing protective guard. Install missing lenses and protective guards on all lighting fixtures in machinery space and lazarette. 46CFR183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 24 March 2022
Resolution: USCG satisfied with pictures that [name withheld] provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 September 2021 Resolved
Penetrations and opening in watertight bulkheads must have means to make watertight. Vessel's fresh water hose penetrated the lazarette/engine room bulkhead and the engine room/# 2 space compartment bulkhead on the port side and penetrations were not watertight. Various electrical cables and wiring penetrations were also found on both port and starboard side of the lazarette and engine room bulkhead that were not watertight. Vessel has old/unused generator piping that penetrates the lazarette/engine room bulkhead in the center of bulkhead that is not watertight. Make all penetrations watertight. 46 CFR 171.114
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 22 October 2021
Resolution: O/O submitted photos of all bulkhead penetrations being properly sealed up.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 September 2021 Resolved
Each opening exposed to the weather must be watertight. Vessel had an installed fresh water hose that penetrated the weather deck over the lazarette compartment on the starboard side of the vessel. Remove penetration and make watertight or install satisfactory metallic valve. 46 CFR 171.124
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 15 October 2021
Resolution: O/O submitted satisfactory photos of an installed valve to the fresh water pipe fitting that penetrated the weather deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2021 Resolved
Life jackets must be stowed in convenient places distributed throughout the accommodation spaces. Each life jacket kept in a stowage container must be readily available. Life jackets are stowed in one centralized location in a forward compartment of the accommodation space located within the head. Passengers on weather deck would need to open three doors to access them. Prepare a proposal in order to have life jackets in an arrangement spread throughout the accommodation spaces and readily available and submit to USCG for review. 46 CFR 180.78.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 26 March 2021
Resolution: Owner sent photos of new arrangement. 18 starboard and 18 aft by the starwell, properly marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 February 2021 Resolved
Each hatch exposed to the weather must be watertight on a partially protected route. Each hatch cover must have a securing device; and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Engine room and laz space hatches do not have securing devices to maintain watertight integrity; hatches are not attached to the vessel. Alternatively, prove watertightness of current arrangement by a 30PSI hose test though a nozzle of not less than .5". 46 CFR 171.214.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02MAR2021. Witnessed satisfactory installation and hydro test with pressurized water hose of ER deck hatches. No water entered ER. - - PDJArnett-CIV
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2021 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flames arresters. The flame screen shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. Vessel was missing flame screen on diesel fuel tank vent pipe discharge end (starboard aft). Replace to standard above. 46 CFR 182.20-35(d).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 12 March 2021
Resolution: Received photo of flame screen installation and receipt of proper type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2021 Resolved
Life ring must be fitted with a lifeline of at least 60ft. Each life buoy with a floating water light must have a lanyard 3-6ft that secures the water light around the body of the ring life buoy. Life Buoy was outfitted with a line attached around the grab line of the buoy and was more than 3-6 feet. Attach 60ft lifeline to life ring and separately attach water light on a 3-6 lanyard, secured around the body of the life ring. 46 CFR 180.70(c) and(d)(2).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02MAR2021. Observed life rings were properly outfitted with lanyard of appropriate material and lengths. -- PDJArnett-CIV
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 February 2021 Resolved
Where fire extinguishing equipment is not required but is installed, the system or equipment and its installation shall meet the requirements of this part. One fire extinguisher in the engine room was overdue for annual service and in the red. Replace or remove extinguisher (this is an extra fire extinguisher per requirement for the space.)46 CFR 181-05-5(a).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 2 March 2021
Resolution: Cleared. 02MAR2021. Observed fire extinguisher had been removed from the ER. -- PDJArnett-CIV
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2020 Resolved
Provide 10 adult PFD's, passenger count is limited to 35 until corrected. 46 CFR 176.808
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2020
Resolved 19 March 2020
Resolution: Operator purchased 10 new life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2020 Resolved
Replace flexible vent hose. 46 CFR 182.20-30
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2020
Resolved 19 March 2020
Resolution: Reviewed operator submitted photo of new hose installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 January 2020 Resolved
Provide emergency procedures at the operating station. 46 CFR 185.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2020
Resolved 19 March 2020
Resolution: procedures have been posted as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 January 2020 Resolved
Vessel passengers are restricted from accessing the bow due to low rail height. If passenger access is desired, submit plans for changes to CG. Address issue at next drydock, activity 6887232
Action required: 705 - Other - as specified
Due 14 February 2020
Resolved 16 February 2021
Resolution: Vessel added additional course of rail to existing configuration. Rail height is now 40 inches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2020 Resolved
Provide plug for fuel filter drain.
Action required: 10 - Deficiency Rectified
Due 14 February 2020
Resolved 14 January 2020
Resolution: Operator provided plug.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 January 2020 Resolved
Replace ball valve with a screw type valve in the forepeak. Due at next drydock.
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 23 September 2021
Resolution: Owner replaced valve, MI witnessed replacement during DD/ISE exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 7 January 2019 Resolved
Small hole found on aft vent on port side where the deck meets the vent approximately 18" forward of the back of the vent. Complete temporary repair, and finish permanent repair at next dry dock. 46 CFR 179.320
Action required: 10 - Deficiency Rectified
Resolved 7 January 2019
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 March 2010 Resolved
KW01 Re-label vessel name on life ring buoy.
Due 10 March 2010
Resolved 10 March 2010
Fire Fighting › Nozzles › Condition
Issued 10 March 2010 Resolved
KW02 Replace broken nozzle on fire hose.
Due 10 March 2010
Resolved 10 March 2010
Construction/Loadline › Structures › Manhole
Issued 10 March 2010 Resolved
KW03 Hatch over lazarette must be watertight
Due 11 June 2011
Resolved 15 February 2012
Resolution: Holes were cut in lazarette hatches and pins were inserted to make the compartment watertight.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 March 2010 Resolved
KW04 One life ring buoy onboard the vessel must have a light attached by a 3ft lanyard w/ at least 60 feet of line also attached to the life ring buoy.
Due 10 March 2010
Resolved 10 March 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 March 2010 Resolved
KW05 Install STBD lazarette light w/ glass housing and metal guard to eliminate electrocution threat.
Due 10 March 2010
Resolved 10 March 2010
Electrical › Electric Generation Source (service) › Switch
Issued 10 March 2010 Resolved
KW06: Install oil pump switch into a designated switchboard.
Due 31 March 2010
Resolved 1 April 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2010 Resolved
KW07 Clean up wires throughout the vessel w/ ties or metal clamps.
Due 31 March 2010
Resolved 10 March 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 December 2009 Resolved
Marine Employer could not produce and accurate and complete Employee Assistance Program proof of training for all crewmembers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2010
Resolved 11 January 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 December 2009 Resolved
Vessel did not have required Alcohol testing equipment for crewmembers for Post-Casualty testing from a Marine Casualty Incident.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2009
Resolved 11 January 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 December 2009 Resolved
Vessel did not conduct required alcohol testing of crewmembers for a Marine Casualty Incident
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2010
Resolved 11 January 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 February 2009 Resolved
Provide proof of enrollment of drug and alcohol program enrollment for all crew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2009
Resolved 3 February 2009
Engineering › Bilge Water Management System › Not Operational
Issued 3 February 2009 Resolved
Prove proper operation of the lazarette bilge suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2009
Resolved 3 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2009 Resolved
Install metal wire ties for all cabling in the engine room not to exceed more than 24 inches.
Due 3 February 2009
Resolved 3 February 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 13 October 2006 Resolved
6 inch piece of flex hose was placed between spool piece and valve. 3 valves were made up like this 2 in the engine room and 1 in the lazarette.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2006
Resolved 16 October 2006
Resolution: Spool piece was removed and new valves were inserted.
Construction/Loadline › Hull › Bottom Plating
Issued 13 October 2006 Resolved
Severe pitting was noted in the aft engine room and in the lazarette. Owner/operator is cropping and renewing 26" X 8" plating in the starboard aft lazarette and the engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2006
Resolved 16 October 2006
Resolution: New bottom plating was installed and pressure tested satisfactory.
Documentation › Certificates/Documents › FCC SSL
Issued 6 February 2006 Resolved
Provide valid FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 23 February 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 February 2006 Resolved
Provide an additional chain in way of all embarkation areas.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 23 February 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2006 Resolved
Repair lighting in way of stbd side engine space.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 23 February 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 February 2006 Resolved
Replace retroreflective material in way of vessel lifefloats.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 6 February 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 February 2006 Resolved
Replace retroreflective material in way of child size lifejackets.
Action required: 705 - Other - as specified
Due 6 March 2006
Resolved 6 February 2006
Documentation › Logs/Records
Issued 11 February 2004 Resolved
Create training manual that meets the requirements of 46CFR185.420. LEGACY COMPONENT DESC: Training Logbook
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 18 February 2004
Resolution: Corrected
Construction/Loadline › Hull › Bottom Plating
Issued 27 May 2003 Resolved
Make permanent repairs to fractured hull plate in way of port head discharge. Minimum inserts shall not be less than 18 x 18 inches with radiused corners.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 29 May 2003
Resolution: Corrected. Vessel authorized to return to service.
Lifesaving › Buoyant Apparatus
Issued 11 February 2003 Resolved
Renew netting on 12 person life float and patch surface cracks using manufacturer's approved patch kit.
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 February 2003 Resolved
Renew retro-reflective tape on 26 adult & 6 child PFD's. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Operations/Management › Drills/Instruction
Issued 11 February 2003 Resolved
Post Emergency Instruction List. LEGACY COMPONENT DESC: Flooding Mitigation
Action required: 705 - Other - as specified
Due 11 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Construction/Loadline › Hull
Issued 30 January 2003 Resolved
Clean welds as indicated for closer inspection where weld porosity is suspected along the the oval inserts located at the wind and waterline at the stern of the vessel. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 January 2003
Resolution: corrected.
Construction/Loadline › Hull › Bottom Plating
Issued 30 January 2003 Resolved
Clean and grind areas of bottom plate in way of clad welds and repair areas by inserting new plate or by using an acceptable marine epoxy to coat pits surrounding the clad welds. Where epoxy is used, those area shall be made available for inspection after the epoxy has set.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 January 2003
Resolution: Corrected. Owner employed the use of marine epoxy ( A-788 Splash Zone by Z-Spar) over ground down clad welds. The Excessive weldment of the clad welds were found porous toward the outer edges of the weldment but once ground were found sound.
Construction/Loadline › Hull
Issued 30 January 2003 Resolved
Vee and re-weld porous weld at chine on starbaord bow located 28 inches forward of the splash rail, in way of the splash rail.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 January 2003
Resolution: Corrected.
Construction/Loadline › Hull
Issued 30 January 2003 Resolved
Grind and epoxy excess weldment in way of previously blanked head discharge, located at the portside bow near the keel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 January 2003
Resolution: Corrected.
Construction/Loadline › Hull
Issued 30 January 2003 Resolved
Vee and re-weld porous weld as indicated in way of oval insert located at the port chine aft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2003
Resolution: Corrected.
Construction/Loadline › Hull
Issued 30 January 2003 Resolved
Renew port raw water seavalve and clean gate on starboard raw water seavalve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2003
Resolution: Onwer replaced both seavalves with new bronze ball valves. Onwer stated that care was taken to isolate the bronze from the aluminum spoolpieces with the use of teflon as an isolator.
Construction/Loadline › Hull
Issued 22 January 2002 Resolved
Removal of 2.5 x 5 inch rectangular doubler patch in way of starboard bow chine revealed a 5 inch fracture in the vessel's hull plating. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper Installation
Due 25 February 2002
Resolved 25 January 2002
Resolution: Crop and renewed 28 x 18 inch section of hull in way of existing fracture.
Construction/Loadline › Hull
Issued 22 January 2002 Resolved
Spool pieces for both the port and starboard MDE raw water intakes were wasted most likely from electrolysis between the bronze sea valve and the aluminum spool piece.
Condition: Improper/Lack of Maintenance
Due 25 January 2002
Resolved 29 January 2002
Resolution: Cropped and renewed
Construction/Loadline › Penetrations
Issued 22 January 2002 Resolved
Replace wasted skin valve in way of starboard side engine room bilge over board discharge.
Condition: Improper/Lack of Maintenance
Due 25 February 2002
Resolved 29 January 2002
Resolution: Replaced with new valve.
Construction/Loadline › Hull
Issued 22 January 2002 Resolved
Grind and reweld 8 inch circular insert in way of vessel's bottom plating, starboard side midship. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Due 25 February 2002
Resolved 29 January 2002
Resolution: Weld grinded out and rewelded.
Construction/Loadline › Hull
Issued 22 January 2002 Resolved
Crop and renew 18x 30 inch inset in way of port bow. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 25 February 2002
Resolved 29 January 2002
Resolution: Removed requirement after discussing with owner. Owner states inset has existed for 14 years and is not severe enough to call for repair. Owner to monitor throughout vessel service and will inspect at next dry docking.
Construction/Loadline
Issued 7 March 2000 Resolved
Repair/renew forepeak bilge line.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Lifesaving
Issued 7 March 2000 Resolved
Log monthly check of EPIRB and inspection of lifesaving equipment.
Condition: Unknown
Due 7 March 2000
Resolved 14 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
Provide/service one BI extinguisher.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 24 February 1999 Resolved
Repair replace ceiling panels in accomodation space: Forward stbd side & port centerline.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Documentation
Issued 24 February 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 February 1999
Resolved 2 March 1999
Lifesaving
Issued 24 February 1999 Resolved
Re-write emergency procedures to reflect actual vessel procedures.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Documentation
Issued 24 February 1999 Resolved
Provide FCC Safety Certificate.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Accommodation/Occupational Safety
Issued 24 February 1999 Resolved
Provide cover for bulkhead, port-side forward (lifejacket locker).
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Electrical
Issued 24 February 1999 Resolved
Provide light cover, stbd side, aft.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Navigation
Issued 8 December 1998 Resolved
Repair/renew stbd rudder stabilizer.
Condition: Unknown
Due 15 December 1998
Resolved 27 December 1998
Construction/Loadline
Issued 8 December 1998 Resolved
Repair fractured welds on longitudinals that are located in aft steering compartment.
Condition: Unknown
Due 15 December 1998
Resolved 27 December 1998
Navigation
Issued 8 December 1998 Resolved
Replace port rudder stock stabilizer.
Condition: Unknown
Due 15 December 1998
Resolved 27 December 1998
Engineering
Issued 20 February 1997 Resolved
Install lagging on exhaust manifolds of both engines.
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Fire Fighting
Issued 20 February 1997 Resolved
Provide 3 fire buckets with lanyards.
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Lifesaving
Issued 20 February 1997 Resolved
Stencil name of vessel on 12 person lifefloat.
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Lifesaving
Issued 20 February 1997 Resolved
Renew battery in waterlight for 22 person lifefloat.
Condition: Unknown
Due 1 March 1997
Resolved 4 March 1997
Electrical
Issued 14 March 1995 Resolved
Make all electrical connections using approved wiring methods as described in 183.05-50. Specifically make electrical connections noted by inspector in the engineroom in electrical boxes.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Fire Fighting
Issued 14 March 1995 Resolved
Remount B-II fire extinguisher located on the forward bulkhead of the engineroom. (Present bracket not acceptable)
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Construction/Loadline
Issued 14 March 1995 Resolved
Replace leaking mechanical (ceramic-carbon) seal on port engine driven bilge/fire pump
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Lifesaving
Issued 14 March 1995 Resolved
Seperate child and adult lifejackets by a partition or other acceptable method. (stowing in a different location)
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Lifesaving
Issued 14 March 1995 Resolved
Replace retro-reflective material on all lifejackets as necessary. Retro on most jackets is deteriorated to a questionable level._x001C_ Discussed the "standard" for lifejackets with the vessel representative.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Engineering
Issued 14 March 1995 Resolved
Adjust packing on both shafts.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Electrical
Issued 11 May 1992 Resolved
REMOVE BATTERIES, CLEAN BOXES AND FIBERGLASS OR LEAD LINE THE SAME.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Lifesaving
Issued 11 May 1992 Resolved
LABEL CAPACITY ON LIFEFLOATS.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Lifesaving
Issued 11 May 1992 Resolved
REATTACH LABEL ON 6 PERSON LIFEFLOAT
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Engineering
Issued 11 May 1992 Resolved
RECONNECT PORT FUEL SHUTOFF
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Engineering
Issued 11 May 1992 Resolved
DISCONNECT ELECTRICAL CONNECTIONS, FUEL LINES AND SEA SUCTION LINES TO INOPERATIVE GENERATOR. PLUG AND/OR CAP FUEL AND SEA WATER LINES.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Construction/Loadline
Issued 11 May 1992 Resolved
REMOVE OIL FROM LAZARETTE BILGE AND CLEAN SAME.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Lifesaving
Issued 11 May 1992 Resolved
SEW STRAPS ON LIFEFLOATS
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Fire Fighting
Issued 11 May 1992 Resolved
REPLACE SEA WATER HOSE TO FIREPOUMP.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Construction/Loadline
Issued 11 May 1992 Resolved
PUMP #2 COMPARTMENT DRY.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Electrical
Issued 19 May 1988 Resolved
INSTALL GUARD OVER ROTATING MACHINERY ON INDEPENDENT GENERATOR.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988

Casualty record · 9

29 April 2005Routine · role: Involved in a Marine Investigation (non-casualty) · activity 2345838
6 April 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2618549
19 February 2009Routine · role: Involved in a Marine Casualty · 1 injured · activity 3423156
1 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3783309
6 February 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4239863
4 March 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4273930
10 April 2012Routine · role: Involved in a Marine Casualty · activity 4287885
30 December 2012Routine · role: Involved in a Marine Casualty · activity 4574298
26 March 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4556728
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.