← All vessels
ALAM GULA
ALAM GULA is a 1985 freight ship. The Coast Guard has recorded 26 inspections since 1985, most recently in March 2009, along with 5 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 1985 to 2009. Most recent: inspection, 22 March 2009.
- Built
- 1985
- Last inspected
- 22 March 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
8505159 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9MCF3
257224
Flag
PANAMA
—
Maury page id
psix-257224
Inspections, by type
…with no type recorded22
Years with a record
15 calendar years (1985–2009)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13815 - Convention (Subpart B), Gross Ton
8010 - Convention (Subpart B), Net Ton
23418 - Dead Weight, Ton
28775 - Displacement, Ton
8010 - Convention (Subpart B), Net Ton
23418 - Dead Weight, Ton
28775 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
22 March 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3437859
11 January 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3392127
10 January 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391880
12 October 2008
MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3337451
4 October 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3338587
2 February 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3141660
29 January 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3138622
27 January 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3137105
2 June 2005
ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2377351
17 November 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1949481
22 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 184486
22 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 426626
22 October 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 383706
17 June 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 367780
20 March 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 356994
3 February 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 348574
16 November 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 340292
24 October 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 333168
3 November 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 326504
20 October 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 319125
18 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 455034
28 January 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 314001
14 October 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 312004
12 May 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 473892
12 May 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 499083
19 September 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 304502
Deficiency record · 5
Documentation
Issued 22 March 1999
Resolved
Obtain Class Society or Flag State approval of the SOPEP. 33 C.F.R. 151.29. Correct prior to next U.S. Port.
Fire Fighting
Issued 22 March 1999
Resolved
Remove hold back hooks on the doors to the steering gear flat and the aft door to the E/R. Fix the main entrance door to the E/R so that it closes properly. SOLAS 74 amd II-2/47. Correct prior to next U.S. Port.
Fire Fighting
Issued 22 March 1999
Resolved
Repair the valve from the priming pump for the emergency fire pump to eliminate oil leakage. SOLAS 74 amd II-2/4.3.3. Correct prior to next U.S. Port.
Electrical
Issued 22 March 1999
Resolved
Obtain Class approval of the electrical wiring for the outlet in the E/R control room and the wiring for the ventilation system in the CO2 room. SOLAS 74 amd II-1/45.1. Correct prior to next U.S. Port.
Navigation
Issued 14 October 1986
Resolved
VESSEL DID NOT HAVE ONBOARD A COPY OF THE INLAND NAVIGATION RULES.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.