INFINITY is a 2001 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 2001, most recently in April 2026, along with 69 deficiencies and 2 casualty investigations between 2002 and 2019.

Records from 2001 to 2026. Most recent: inspection, 9 April 2026.

Built
2001
Last inspected
9 April 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5727
Flag
UNITED STATES
367162680
Maury page id
psix-25759

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (2001–2026)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)99.5 ft × 22.0 ft × 6.0 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)99.5 ft × 22.0 ft × 6.0 ft
ITC tonnagegross 220 / net 74
BuilderMID CITY STEEL FABRICATIN · LA CROSSE, WI, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST CLAIR SHORES, MI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
220 - Convention (Subpart B), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
74 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD5727MMSI 367162680 · active · compulsorily equipped · granted 8 February 2017, expires 25 January 2027
WDC2504MMSI 366994030 · expired · compulsorily equipped · granted 27 November 2004, cancelled 31 January 2015 · licensed under a name not among this hull’s recorded names (not shown)
WDA7470MMSI 366843670 · expired · compulsorily equipped · granted 23 March 2002, cancelled 26 May 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

9 April 2026 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8345118
13 August 2025 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8208902
7 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8106314
3 October 2024 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8012998
10 April 2024 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7892867
29 March 2023 Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7659156
7 April 2022 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7425067
21 April 2021 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7164973
29 June 2020 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6990589
11 November 2019 Examination of Repairs · Damage Survey · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6873008
16 August 2019 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6785069
21 May 2019 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6689974
10 April 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6659831
6 April 2018 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6385866
27 March 2018 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6383941
27 October 2017 Examination of Repairs · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6295944
7 April 2017 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6117283
2 December 2016 Drydock Extension
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6052516
12 April 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5857693
15 March 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5836319
14 August 2014 Plan Review "T" Boat
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4960562
9 September 2011 In-Service Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4140051
22 October 2010 DAPI Audit
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3879016
13 April 2009 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3454511
23 April 2008 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3190409
26 April 2007 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2916828
23 October 2006 Damage Survey
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2806337
2 August 2006 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2734868
8 July 2006 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2704535
2 March 2006 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2594752
4 October 2005 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2506954
21 September 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2497868
7 February 2005 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2288050
26 November 2004 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2248092
24 August 2004 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2174792
12 March 2004 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2023297
29 January 2004 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1996813
20 August 2003 Annual Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1882184
28 May 2003 Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1804023
21 May 2003 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1798419
29 March 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1777645
6 August 2002 Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1657540
30 July 2002 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1654308
22 June 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1636010
18 June 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413962
20 May 2001 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1379442

Deficiency record · 69

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 August 2025 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Observed vessel crew not conducting monthly checks of fire extinguishers. 46 CFR 176.810(b)(1)(ii)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 August 2025
Resolution: Inspections conducted and operator informed on requirement.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 6 May 2025 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instructions indicate use of life line and instruct crew to enter water if necessary to retrieve passengers. Master advised he would not instruct any crewmember to enter water. Life lines are not provided to crew. Revise procedure to align with Master's/company expectations and available equipment w/in 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 May 2025
Resolved 8 May 2025
Resolution: Emergency instructions updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2025 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring buoy found without reflective tape. Install tape on both sides of buoy per IMO specifications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 May 2025
Resolved 21 May 2025
Resolution: Retro tape added to lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 April 2022 Resolved
The owner/operator must provide satisfactory evidence of the required servicing to the marine inspector. Clean agents require weighing the cylinder and inspecting the hoses and nozzles as per the manufacturer's instruction manual. Fixed fire extinguishing system in the bow thruster space was found to not be tested/inspected since installation. Manufacture's instruction manual states that weighing of the cylinder shall be semi-annually. If the weight changes more than 32 OZ then it is to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 13 April 2022
Resolution: Received email confirmation that the pre engineered fixed fire fighting system for the bow thruster space had been serviced by an authorized technician. Weight change was within acceptable paramenters. System was reinstalled and put back into service. See
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 April 2021 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons overboard. Abandon ship and man overboard drills and training shall be logged for review by the USCG including the date and general description of the drill/training. Drills were not carried out as required or logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 April 2021 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire and shall be logged or documented for review by the USCG including date and general description of the drill and training topics. Drills were not carried out or logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 April 2021 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not verified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 April 2021 Resolved
The Master and crew of a vessel will be familiar with the content and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 April 2021 Resolved
Each officer employed upon any vessel subject to provisions of this subchapter must have his or her license or MMC on board and available for examination at all times when the vessel is operating. Documents were not on board at time of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 21 April 2021 Resolved
Employee Assistance Program (EAP): each EAP must include at least the following: display and distribution of a community service hotline telephone number for crewmember assistance and display and distribution of the employer's policy regarding drug and alcohol use in the work place. No postings of the policy or phone number were found.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 April 2021 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship, man overboard and fire drill be held under simulated emergency condition specified by the inspector. Drills are required to be carried out after new crew is hired on board for the summer season. Notify Coast Guard of the date drills will be carried out for attendance by Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 5 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2020 Resolved
Each lifejacket must be approved in accordance with 160.002, 160.005, or 160.055 in subchapter Q of this chapter and must be marked in accordance with 185.604. Child lifejackets carried on board are type II and are not approved for vessel service. Vessel is not allowed to carry child passengers until such time the proper lifejackets are provided.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2019 Resolved
Light list, coast pilot, and charts are outdated. Vessel shall update or renew all three.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 21 May 2019
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 April 2019 Resolved
Due to weather we could not get the vessel underway. vessel shall conduct fire and MOB drill to satisfaction of the attending USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 21 May 2019
Lifesaving › Lifebuoys › Serviceable
Issued 12 April 2016 Resolved
Aft ring buoy is worn and no longer serviceable. Replace ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 21 April 2016
Resolution: Ring buoy renewed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 April 2016 Resolved
Float light approval is expired. Replace with an approved float light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 21 April 2016
Resolution: New float light with current approval installed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 April 2016 Resolved
Lifeline on forward ring buoy is white. Replace with line that complies with 46 CFR 180.70(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 21 April 2016
Resolution: Line renewed with 3/8 three strand black poly pro. Sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 October 2005 Resolved
Provide non-corrosive clip with lanyard on upeer deck ring buoy.
Action required: 705 - Other - as specified
Due 18 October 2005
Resolved 5 October 2005
Resolution: Cleared
Electrical › Electrical Distribution System (service) › Cable
Issued 4 October 2005 Resolved
Clean battery posts prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2005
Resolved 5 October 2005
Resolution: Cleared
Construction/Loadline › Structures › Superstructure
Issued 4 October 2005 Resolved
Replace cracked STBD side superstructure window.
Action required: 705 - Other - as specified
Due 18 October 2005
Resolved 2 March 2006
Resolution: CLEARED
Construction/Loadline › Hull › Bottom Plating
Issued 21 September 2005 Resolved
INSERT/WELD NEW BOTTOM PLATE PORT SIDE OF ENGINEROOM BILGE WHERE THE 4' X 4' PLATE WAS CROPPED OUT BY MISTAKE.
Due 4 October 2005
Resolved 23 September 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 November 2004 Resolved
PROVIDE UPDATED CERTIFICATE OF DOCUMENTATION REFLECTING NEW OWNER AND NEW VESSEL NAME.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 7 February 2005
Documentation › Certificates/Documents › FCC SSL
Issued 26 November 2004 Resolved
PROVIDE UPDATED FCC RADIO STATION LICENSE AND FCC SAFETY RADIOTELEPHONE CERTIFICATE.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 7 February 2005
Documentation › Logs/Records › Logbook (official)
Issued 26 November 2004 Resolved
PROVIDE LIFESAVING EQUIPMENT MAINTENANCE LOG.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 7 February 2005
Lifesaving › Buoyant Apparatus › Painter
Issued 26 November 2004 Resolved
PROVIDE AND INSTALL NEW LIFEFLOAT PAINTER LINES AT A MINIMUM OF 45 FEET IN LENGTH.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 7 February 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 November 2004 Resolved
PROVIDE AND INSTALL LATCHING DEVICE FOR ENGINE ROOM HATCH.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 7 February 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 26 November 2004 Resolved
PROVIDE AND POST ENGINE ROOM AND BOW THRUSTER ROOM FIXED FIRE FIGHTING SYSTEM OPERATING INSTRUCTIONS.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 7 February 2005
Personnel › Training › Seamanship
Issued 20 August 2004 Resolved
Train all masters on EPIRB testing & logging procedures.
Condition: Unknown
Due 8 September 2004
Resolved 26 November 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 20 August 2004 Resolved
Prove current servicing of bow thruster room fixed fire extinguishing system (post watch while operating bow thruster until this deficiency is cleared).
Condition: Improper/Lack of Maintenance
Due 8 September 2004
Resolved 26 November 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 20 August 2004 Resolved
Repair broken sewage tank holddown strapping.
Condition: Unknown
Due 8 September 2004
Resolved 7 February 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 20 August 2004 Resolved
Pipe hot water heater relief line to bilge.
Condition: Design Flaw
Due 8 September 2004
Resolved 26 November 2004
Electrical › Lighting (service)
Issued 20 August 2003 Resolved
Repair light fixture in lazerette and install proper bulb. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 25 August 2003
Resolved 25 August 2003
Resolution: Repaired, test sat.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 20 August 2003 Resolved
Replace belt cover on port MDE.
Condition: Unknown
Due 20 August 2003
Resolved 20 August 2003
Resolution: Cover replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 August 2003 Resolved
Replace cover to hot water heater electrical connection box.
Condition: Unknown
Due 20 August 2003
Resolved 20 August 2003
Resolution: Cover replaced.
Lifesaving › Buoyant Apparatus
Issued 20 August 2003 Resolved
Provide proper lanyard for ring buoy and painters for lifefloats. LEGACY COMPONENT DESC: Lanyard
Condition: Placed in Improper Service
Due 25 August 2003
Resolved 25 August 2003
Resolution: Completed.
Communications › Radio Communications
Issued 20 August 2003 Resolved
EPIRB; prove current registration. (vessel limited to 3 miles from shore) LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 25 August 2003
Resolved 29 January 2004
Resolution: Completed.
Lifesaving › Buoyant Apparatus
Issued 20 August 2003 Resolved
Replace cracked paddles for lifefloats, label and properly attach. LEGACY COMPONENT DESC: Lifefloat
Condition: Improper/Lack of Maintenance
Due 25 August 2003
Resolved 25 August 2003
Resolution: Completed.
Lifesaving › Buoyant Apparatus
Issued 20 August 2003 Resolved
Provide holding rack for upper deck ring buoy. LEGACY COMPONENT DESC: Ring Buoy
Condition: Placed in Improper Service
Due 20 August 2003
Resolved 20 August 2003
Resolution: Rack installed.
Accommodation/Occupational Safety › Ventilation
Issued 20 August 2003 Resolved
Replace cracked windows on bridge and main deck cenerline forward (2). LEGACY COMPONENT DESC: Windows
Condition: Unknown
Due 20 September 2003
Resolved 29 January 2004
Resolution: Completed.
Lifesaving › Buoyant Apparatus
Issued 20 August 2003 Resolved
Repair stbd lifefloat and upper deck ring buoy with approved [name withheld] repair kit.
Condition: Unknown
Due 25 August 2003
Resolved 25 August 2003
Resolution: Equipment repaired.
Navigation › Piloting/Steering
Issued 20 August 2003 Resolved
Provide current charts, coast pilot and light list. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Due 25 August 2003
Resolved 25 August 2003
Resolution: Nav pubs updated.
Engineering
Issued 20 August 2003 Resolved
Prove proper operation of stbd bridge window wiper. LEGACY COMPONENT DESC: Window Wipers
Condition: Improper/Lack of Maintenance
Due 25 August 2003
Resolved 25 August 2003
Resolution: Repaired, test sat.
Navigation › Piloting/Steering
Issued 20 August 2003 Resolved
Callibrate magnetic compass and provide a current deviation table. LEGACY COMPONENT DESC: Magnetic Compass
Due 2 September 2003
Resolved 29 January 2004
Resolution: Completed.
Construction/Loadline › Markings
Issued 28 May 2003 Resolved
Paint all draft markings a contrasting color with hull as needed. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 31 May 2003
Resolved 2 June 2003
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment
Issued 28 May 2003 Resolved
Lock closed or remove valve handle to forward waste pumpout overboard. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 31 May 2003
Resolved 2 June 2003
Resolution: Handle removed.
Documentation › Certificates/Documents
Issued 6 August 2002 Resolved
Provide stability letter LEGACY COMPONENT DESC: Stability Letter
Due 20 August 2002
Resolved 22 August 2002
Documentation › Certificates/Documents
Issued 6 August 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 20 August 2002
Resolved 22 August 2002
Documentation › Certificates/Documents
Issued 6 August 2002 Resolved
Provide Safety Radio Certificate LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Due 5 September 2002
Resolved 6 September 2002
Resolution: Reviewed current Safety radio Certificate.
Operations/Management › Drills/Instruction
Issued 6 August 2002 Resolved
Conduct and log man overboard and fire drills. LEGACY COMPONENT DESC: Fire
Due 20 August 2002
Resolved 22 August 2002
Documentation › Manuals/Policy Documentation
Issued 6 August 2002 Resolved
Provide emergency instructions LEGACY COMPONENT DESC: Emergency Instructions
Due 20 August 2002
Resolved 22 August 2002
Navigation › Piloting/Steering
Issued 6 August 2002 Resolved
Provide compass deviation table LEGACY COMPONENT DESC: Compass Deviation Table
Due 5 September 2002
Resolved 25 August 2003
Resolution: Cleared this requirment because they provided a deviation table, however the table showed deviations of up to 25 degrees. Issued a CG 835 to callibrate compass.
Documentation › Markings/Placards
Issued 6 August 2002 Resolved
Provide emergency broadcast placard LEGACY COMPONENT DESC: Emergency Broadcast Placard
Due 20 August 2002
Resolved 22 August 2002
Communications › Radio Communications
Issued 6 August 2002 Resolved
Ensure EPIRB is registered with new owner/operator information LEGACY COMPONENT DESC: EPIRB
Due 20 August 2002
Resolved 22 August 2002
Communications › Radio Communications
Issued 6 August 2002 Resolved
Ensure that EPIRB is installed correctly and is ready for use LEGACY COMPONENT DESC: EPIRB
Due 20 August 2002
Resolved 22 August 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 6 August 2002 Resolved
Securely mount soft drink pump LEGACY COMPONENT DESC: Soft drink equipment
Due 20 August 2002
Resolved 22 August 2002
Electrical › Electrical Distribution System (service)
Issued 6 August 2002 Resolved
Provide cover for junction box serving fresh water pump in fuel tank space LEGACY COMPONENT DESC: Junction Box
Due 20 August 2002
Resolved 22 August 2002
Fire Fighting › Remote Fuel Shutoff
Issued 6 August 2002 Resolved
Prove proper operation of engine room remote fuel shutoff system
Due 20 August 2002
Resolved 22 August 2002
Engineering › Shafting/Propeller Arrangements
Issued 6 August 2002 Resolved
Adjust port and starboard stuffing boxes in accordance with manufacturer's specifications LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Due 20 August 2002
Resolved 22 August 2002
Engineering › Bilge Water Management System
Issued 6 August 2002 Resolved
Prove proper operation of bilge pumping system LEGACY COMPONENT DESC: Piping
Due 20 August 2002
Resolved 22 August 2002
Fire Fighting › Fire Pumps
Issued 6 August 2002 Resolved
Replace or repair fire pump and prove proper operation prior to carrying passengers
Due 20 August 2002
Resolved 22 August 2002
Documentation › Manuals/Policy Documentation
Issued 6 August 2002 Resolved
Provide instructions for operating bilge and fire system LEGACY COMPONENT DESC: Bilge/Fire Pump
Due 20 August 2002
Resolved 22 August 2002
Navigation
Issued 18 June 2001 Resolved
Prove proper operation of port running light.
Condition: Unknown
Due 30 June 2001
Resolved 26 June 2001
Lifesaving
Issued 18 June 2001 Resolved
Provide manufacturers documentation for lines used on PLEs & ring buoys.
Condition: Unknown
Due 30 June 2001
Resolved 2 July 2001
Documentation
Issued 18 June 2001 Resolved
Provide FCC documentation - Safety Telephone Certificate and Station license.
Condition: Unknown
Due 30 June 2001
Resolved 26 June 2001
Lifesaving
Issued 18 June 2001 Resolved
Provide 6 adult & 1 child size PFD to equal 162 adult & 17 children total.
Condition: Unknown
Due 30 June 2001
Resolved 2 July 2001
Lifesaving
Issued 18 June 2001 Resolved
Prove proper operation of 1 life float waterlight.
Condition: Unknown
Due 30 June 2001
Resolved 26 June 2001
Lifesaving
Issued 18 June 2001 Resolved
Affix EPIRB registration to unit & provide copy to U.S. Coast Guard.
Condition: Unknown
Due 30 June 2001
Resolved 2 July 2001
Navigation
Issued 20 May 2001 Resolved
Replace port side navigation (docking) camera with correct image oriented camera.
Condition: Unknown
Due 20 May 2001
Resolved 20 May 2001
Lifesaving
Issued 20 May 2001 Resolved
Complete "new to zone" inspection and crew drills upon arrival in new home port, and prior to carrying passengers, to the satisfaction of the cognizant OCMI & attending marine inspector.
Condition: Unknown
Due 20 May 2001
Resolved 20 May 2001

Casualty record · 2

22 June 2002Routine · role: Involved in a Marine Casualty · activity 1636010
16 August 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6785069
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CAYAH AMANDA (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record