Records from 1985 to 2008. Most recent: inspection, 6 June 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
6 June 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3229111
5 March 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2596244
27 February 2006
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2592862
30 June 2004
ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2116153
23 June 2004
PII Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2108929
4 June 2004
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2088737
17 July 2003
Annual Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1849241
9 April 2003
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770548
20 March 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1763291
6 August 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1657585
24 April 2002
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1608842
3 August 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292452
24 October 1999
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 434052
29 September 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 433143
10 July 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 701668
27 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392751
9 June 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 379128
31 May 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 367226
12 November 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 362114
2 December 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354770
23 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463808
27 October 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 499940
2 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 347968
22 October 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 339935
11 January 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 320534
5 October 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 304590
Fire Fighting › Fire Hydrants
Issued 9 April 2003
Resolved
Fire hydrant and possible associated piping located on forecastle was found to be plugged, not allowing adequate pressure. Solas 74 (unamended), Ch.II-2, Reg. 5 (e). Correct within 30 days. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 17 July 2003
Resolution: Light covers were replaced.
Fire Fighting › Fire Main
Issued 9 April 2003
Resolved
A temporary patch was observed on the fire main, starboard side, near #4 cargo hold. Solas 74 (unamended), Ch. II-2, Reg. 5 (e). Correct within 30 days. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 17 July 2003
Resolution: Fire main was replaced.
Electrical › Lighting (service)
Issued 9 April 2003
Resolved
One light cover was found to be missing and one light cover was broken on related fixtures located in the forcastle locker. ILO 147. Correct within 30 days. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 17 July 2003
Resolution: Light cover was replaced.
Documentation › Certificates/Documents
Issued 6 August 2002
Resolved
The vessel's IOPP Record of Construction and Equipment does not show the maximum throughput of the OWS. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 8 August 2002
Resolution: Received copy of corrected class certificate satisfying requirement.
Navigation
Issued 3 August 2001
Resolved
Echo depth sounding device unable to continously record depth sounding in violation of 33 CFR 164.35(i).
Condition: Unknown
Due 4 August 2001
Resolved 6 August 2001
Documentation
Issued 29 September 1999
Resolved
Update oil transfer procedures IAW 33 CFR 155.750 prior to any oil_x001C_ transfer operation,including internal transfer.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Fire Fighting
Issued 29 September 1999
Resolved
Provide proffessional approved servicing report where CO2 system is not ready for immediate use due to air blow down line open, CO2 pipe to cargo hold manifold blanked closed, valve labels painted over and loose gear in CO2 room. SOLAS 74 II-2/8. Correct prior to departure.
Condition: Unknown
Due 29 September 1999
Resolved 2 October 1999
Navigation
Issued 27 June 1996
Resolved
The vessel was operating in U.S. waters with an inop. Secondary Radar, no notification to the COTP of New Orleans, noted during Port State Control Examination. The vessel was placed on a COTP restriction and required to submit a Letter of Undertaking in the amount of $25,000.00.
Condition: Unknown
Due 28 June 1996
Resolved 10 July 1996
Fire Fighting
Issued 9 June 1995
Resolved
SOLAS/II-214_x001C_ FIREMAIN LEAKED UNDER PRESSURE WHEN TESTED.
Condition: Unknown
Due 13 June 1995
Resolved 11 June 1995
Documentation
Issued 11 January 1988
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Navigation
Issued 11 January 1988
Resolved
VESSEL'S CHART 18524(22ED 27APR85) HAD NO CORRECTIONS.
Condition: Unknown
Due 16 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988
Resolved
VESSEL'S CHART 18521(55ED 26OCT85) HAD NO CORRECTIONS.
Condition: Unknown
Due 16 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988
Resolved
VESSEL'S ARPA UNIT DID NOT HAVE A LABEL INDICATING MET REQUIREMENTS OF MINIMUN PERFORMANCE STANDARDS.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Navigation
Issued 11 January 1988
Resolved
VESSEL'S CHART 18526(43ED 17MAR84) HAD NO CORRECTIONS.
Condition: Unknown
Due 16 January 1988
Resolved 11 January 1988
Navigation
Issued 11 January 1988
Resolved
VESSEL'S CHART 18523(42ED 09FEB85)HAD NO CORRECTIONS.
Condition: Unknown
Due 16 January 1988
Resolved 11 January 1988