Records from 1985 to 2018. Most recent: inspection, 17 April 2018.
Inspection history · 25
17 April 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392920
23 February 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2590982
18 February 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2587713
8 November 2004
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2236805
5 April 2004
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2037495
6 October 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1923469
6 October 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1924194
1 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1919351
28 September 2003
Annual Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1915159
24 January 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1481006
6 April 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 42253
5 April 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 276595
27 May 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 416280
7 March 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 413406
16 March 1996
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 388841
29 September 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 383339
3 January 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 373821
9 September 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 360722
4 October 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 353415
13 July 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 344752
20 November 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 340202
8 March 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 321711
17 January 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 313828
18 October 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 304849
16 October 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 304794
Fire Fighting › Fire Hoses › Condition
Issued 23 February 2006
Resolved
Two fire hoses found to have excessive leakage when the emergency fire pump was run.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 February 2006
Resolution: Corrected on scene. Spares were on board
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 8 November 2004
Resolved
Ships automatic radar plotting aid is not functioning. Properly repair ARPA and provide report via fax to sector miami attesting to the proper operation of the vessel's ARPA. Report may be from appropriate flag state rep or qualified technician rep.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2004
Construction/Loadline › Hull › Bracket
Issued 5 April 2004
Resolved
Make permanent repairs to fractured coaming bracket at #5 cargo hold forward port and aft starboard corner
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: Recieved class report attesting to repairs.
Construction/Loadline › Hull › Bracket
Issued 5 April 2004
Resolved
Make permanent repairs to fractured coaming bracket at #4 cargo hold starboard side forward and port side aft prior to departure from port to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: Recieved class report attesting to repairs.
Construction/Loadline › Hull › Bracket
Issued 5 April 2004
Resolved
Make permanent repairs to fractured coaming bracket at #3 cargo hold port and starboard side aft and port and starboard side forward prior to departure from port to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: Recieved class report attesting to repairs
Construction/Loadline › Hull › Bracket
Issued 5 April 2004
Resolved
Make permanent repairs to fractured coaming bracket at #2 cargo hold port side aft and port side forward prior to departure from port to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: recieved class report attesting to repairs.
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2004
Resolved
Provide class approval for insert welded aft of #5 cargo hold prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: recieved class report attesting to repairs
Construction/Loadline › Hull › Hull Plating
Issued 5 April 2004
Resolved
Provide class approval for the to inserts welded port side hull aft to shear strake prior to departure from port
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2004
Resolution: recieved class report attesting to repairs
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 28 September 2003
Resolved
The main engine cooling water pump has been removed and is to be sent ashore for repairs to the motor. The stand-by ballast pump is being used as the main engine cooling water pump. Make repairs to the satisfaction of class by 01Oct03. LEGACY COMPONENT DESC: Cooling water pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 2 October 2003
Resolution: Received Class report stating the motor for the pump has been re-wound and installed. The main engine cooling water pump has been tested and found satisfactory.
Lifesaving › Lifeboat Equipment
Issued 24 January 2002
Resolved
PORT LIFEBOAT MISSING 3 FOOD RATIONS, AND STARBOARD LIFEBOAT MISSING 1 FOOD RATION, IN VIOLATION OF SOLAS 74/78 III/41.8.12. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2002
Resolved 26 January 2002
Resolution: RECEIVED FAX RECEIPT OF PURCHASE WITH SHIP''S STAMP. CLEARED DEFICIENCY.
Electrical
Issued 24 January 2002
Resolved
WASTED ELECTRICAL CONDUIT PORTSIDE, AMIDSHIP, OUTBOARD OF CARGO HATCH COMBING--IN VIOLATION OF SOLAS 74/78 II-1/PART D/45.5.5. TO BE ADDRESSED AT DRYDOCK (APR/MAY 2002) WITH CLASS APPROVAL. LEGACY COMPONENT DESC: ELECTRICAL CONDUIT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 28 September 2003
Resolution: Verified repairs.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 January 2002
Resolved
THREE STAIRTREADS (BOTTOM TREADS) STARBOARD SIDE OF VESSEL SEVERELY WASTED, IN VIOLATION OF ICLL 66. TO BE ADDRESSED AT DRYDOCK (APR/MAY 2002) WITH CLASS APPROVAL. LEGACY COMPONENT DESC: STAIRTREADS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 28 September 2003
Resolution: Verified repairs.
Lifesaving
Issued 5 April 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Lifesaving
Issued 5 April 2000
Resolved
VESSEL FAILED FIRE DRILL. CREW PERFORMED SATISFACTORY DRILL ON 06APR00.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Lifesaving
Issued 5 April 2000
Resolved
HYDROSTATIC RELEASE FOR STARBOARD LIFERAFT WAS OUTDATED. VESSEL MUST REPLACE PRIOR TO DEPARTURE. VESSEL CORRECTED DEFICIENCY ON 06APR00.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Accommodation/Occupational Safety
Issued 5 April 2000
Resolved
RAILING BY STARBOARD PILOT LADDER WAS WASTED AND NEEDS TO BE REPAIRED PRIORTO NEXT U.S. PORT AFTER SAILING FOREIGN.
Condition: Unknown
Due 5 May 2000
Resolved 24 January 2002
Resolution: PERFORMED INSPECTION OF RAIL DURING ANNUAL EXAM. RAIL WAS REPAIRED SATISFACTORY. CLEARED DEFICIENCY.
Documentation
Issued 7 March 1998
Resolved
NO RECORDS ON BOARD OF GARBAGE DISCHARGES AT PORT RECEPTION FACILITIES.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Navigation
Issued 7 March 1998
Resolved
CHARTS FOR THE AREA TO BE TRANSITED DID NOT HAVE CURRENT CORRECTIONS.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 7 March 1998
Resolved
NO U.S. COAST PILOT ON BOARD.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Fire Fighting
Issued 7 March 1998
Resolved
FIREMAIN SUPPLY PIPING TO FORWARD PAINT LOCKER SPRINKLER SYSTEM BROKEN.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Documentation
Issued 7 March 1998
Resolved
CREW FAILED TO ADHERE WITH VESSEL'S WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 7 March 1998
Resolved
FOOD RATIONS WITHIN EACH LIFEBOAT NOT AIRTIGHT.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 7 March 1998
Resolved
NO LIGHT LIST ON BOARD.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 7 March 1998
Resolved
NO CURRENT TIDAL CURRENT TABLE ON BOARD.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 7 March 1998
Resolved
NO CURRENT SAILING DIRECTIONS ON BOARD.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 7 March 1998
Resolved
EXPIRED BATTERIES IN BOTH RADAR TRANSPONDERS (SART).
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 16 October 1985
Resolved
CHARTS 11411,11412,11413 WERE NOT CURRENT OR CORRECTED.
Condition: Unknown
Due 18 October 1985
Resolved 16 October 1985
Navigation
Issued 16 October 1985
Resolved
US COAST PILOT,CG LIGHT LIST,TIDAL CURRENT TABLE AND LOCAL NTM NOT CURRENT OR UPDATED.
Condition: Unknown
Due 18 October 1985
Resolved 16 October 1985
Documentation
Issued 16 October 1985
Resolved
DISCHARGE OF OIL PROHIBITED PLACARD NOT DISPLAYED/MISSING.
Condition: Unknown
Due 18 October 1985
Resolved 16 October 1985
Documentation
Issued 16 October 1985
Resolved
VESSELS OIL RECORD BOOK WAS VOID OF ENTRIES.
Condition: Unknown
Due 18 October 1985
Resolved 16 October 1985