Records from 1985 to 1992. Most recent: inspection, 13 April 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
13 April 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 684513
10 April 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 350051
10 April 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 958152
1 October 1990
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 905417
25 August 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 332158
29 July 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331712
29 July 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1349834
3 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197327
1 December 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 506182
1 September 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 325447
28 May 1988
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 323600
28 May 1988
Certificate of Compliance
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1198470
18 June 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 515356
25 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306696
8 November 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 305335
8 November 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1302707
Navigation
Issued 10 April 1992
Resolved
LIGHT LIST NOT CURRENTLY CORRECTED FOR AREA TRANSITED.
Condition: Unknown
Due 10 May 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 10 April 1992
Resolved
TIDAL CURRENT TABLES MISSING.
Condition: Unknown
Due 10 May 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 10 April 1992
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 10 May 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 10 April 1992
Resolved
OIL RECORD BOOK INCOMPLETE.
Condition: Unknown
Due 10 April 1992
Resolved 13 April 1992
Engineering
Issued 10 April 1992
Resolved
PLACE BLANKS ON ALL TRANSFER HOSES ON DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 10 April 1992
Resolved
PROVIDE MECHANICAL PLUGS FOR CARGO OIL CONTAINMENT SYSTEM AND FOR ALL FUEL CONTAINMENT AREAS.
Condition: Unknown
Due 24 April 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 10 April 1992
Resolved
PROVIDE DOCUMENTATION PROVING THAT LIFEBOAT FALLS HAVE BEEN RENEWED OR END FOR ENDED WITHIN THE PAST 30 MONTHS IAW SOLAS 74 CHAP III/REG 19.4._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 10 April 1992
Resolved
REPLACE FLAME SCREENS ON THE FOLLOWING PRESSURE/VACUUM VENTS; #1 PORT DOUBLE BOTTOM, #4P CARGO TANK, #5S DB, #6S DB AND ON THE PORT SLOP TANK.
Condition: Unknown
Due 24 April 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 10 April 1992
Resolved
CLEAN OUT THE FOLLOWING PRESSURE/VACUUM VENTS; #2P DB, #2S DB, #3S DB AND #4S DB._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 1 October 1990
Resolved
VESSEL IS NOT TO TRANSFER CARGO IN U.S. WATERS UNTIL DEF IS CORRECTED.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990
Deck/Cargo
Issued 29 July 1989
Resolved
THE CARGO TANK PV VALVE FLAME SCREENS MUST BE RENEWED (DUE TO PRESENCE OF EXCESSIVE AMOUNT OF PAINT ON SCREENS) PRIOR TO RETURN NEXT U.S. PORT.
Condition: Unknown
Due 29 July 1989
Resolved 29 July 1989
Deck/Cargo
Issued 29 July 1989
Resolved
THE CARGO PUMP ROOM MUST BE MADE GAS-FREE, CERTIFIED BY A MARINE CHEMIST, AND MADE AVAILABLE FOR USCG INSPECTION NO LATER THAN 30OCT89.
Condition: Unknown
Due 29 July 1989
Resolved 29 July 1989
Navigation
Issued 1 September 1988
Resolved
A VIO OF 33 CFR 164.11(R) IN THAT THE ECHO DEPTH SOUNDER REQ. BY 33 CFR 164.35(H) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/WIN THE NAVIGABLE WATERS OF THE U.S
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988
Documentation
Issued 28 May 1988
Resolved
VSL BOARDED PORT OF TOLEDO BY MSO BOARDING PARTY FOR ANNUAL EXM. VSL DID NOT HAVE OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720
Condition: Unknown
Due 28 May 1988
Resolved 28 May 1988