Records from 1985 to 2003. Most recent: inspection, 2 May 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
2 May 2003
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1780900
29 April 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1783795
29 April 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1813430
13 March 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 288101
19 May 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 278719
20 February 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 73998
2 February 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 274162
12 January 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 424214
11 August 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 419074
21 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 407838
2 August 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 406422
16 December 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 398192
26 August 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394421
4 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 378844
27 April 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 377657
4 September 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 370632
29 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 363344
1 February 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 355972
10 October 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 339713
4 October 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 332864
1 September 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 325441
29 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 517548
26 October 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 319258
2 September 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 318334
31 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 318365
4 December 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 313188
8 September 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 311184
1 November 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 305235
25 October 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 304973
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 May 2003
No resolution recorded
Fix to the satisfaction of class the leaks on the following lines: suction side of the main fire pump pipe and the discharge side of the diesel generator cooling pipe. SOLAS 74 I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Logs/Records › Oil Record Book
Issued 2 May 2003
No resolution recorded
The vessel only has onboard the Oil Record Book going back to 29-Mar-03. Provide the original Oil Record Book for the past three years. MARPOL 73/78 I/20
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Personnel › Training › Familiarization Training
Issued 2 May 2003
No resolution recorded
Update crew familiarization to comply with STCW 95 A-VI/1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving
Issued 11 August 1998
Resolved
Remove all paint containers from behind heavy oil settling tank and properly store in paint locker. SOLAS II-2/18.7
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Fire Fighting
Issued 11 August 1998
Resolved
Ensure all fire doors leading from engine room and around galley are self closing. SOLAS II-2/47
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Fire Fighting
Issued 2 August 1997
Resolved
REMOVE HOLDBACKS FROM FIREDOORS PRIOR TO RETURN TO a U.S. port. IAW SOLAS 74 CH II-2 PART B REGULATION 23.
Condition: Unknown
Due 21 September 1997
Resolved 24 September 1997
Fire Fighting
Issued 26 August 1996
Resolved
PROVIDE SPANNER WRENCHES FOR ALL FIRE HOSE STATIONS. SOLAS CHAPT II-2 REG4. COMPLETED PRIOR TO NEXT U.S. PORT CALL.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Engineering
Issued 27 April 1995
Resolved
Make permanent repairs to salt water piping (holed) on port side aft - to air compressor cooler, prior to departure, per SOLAS Chap II-1, Reg 26(1)
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Construction/Loadline
Issued 27 April 1995
Resolved
Make permanent repair to drain line (patched) on port side, aft of lower level engineroom, prior to departure, per SOLAS Chap II-1, Reg 26(1)
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Engineering
Issued 27 April 1995
Resolved
Make permanent repairs to salt water piping (holed) on starboard fresh water cooler inlet and outlet, prior to departure, per SOLAS Chap II-1, Reg26(1)
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Navigation
Issued 31 August 1987
Resolved
VESSEL DID NOT HAVE PORT OF PORT ANGELES CHART 18468 ED. 15. 33 CFR 164.33 (A)(1)(I),(II).
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Navigation
Issued 31 August 1987
Resolved
VESSELS CHARTS 18465 & 18460 NOT CORRECTED UP TO DATE ASREQUIRED BY 33 CFR 164.33(A)(1)(I).
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Documentation
Issued 31 August 1987
Resolved
OIL TRANSFER PROCEDURES WERE NOT COMPLETE IN ACCORDANCE WITH 33 CFR 155.750
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Accommodation/Occupational Safety
Issued 8 September 1986
Resolved
VESSEL HAD A TYPE II MARINE SANITATION DEVICE THAT DID NOT HAVE THE REQUIRED CHEMICALS INSTALLED IN THE DEVICE, THERE-BY ALLOWING RAW UNTREATEDSEWAGE TO BE DISCHARGED INTO U.S. WATERS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Navigation
Issued 8 September 1986
Resolved
VESSEL HAD A 1985 USCG LIGHT LIST ON BOARD THAT WAS ONLY CORRECTED UP TO NOTICE TO MARINERS #52/85. THERE WERE NO 1986 CORRECTIONS IN THE PUBLICATION.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986