Records from 1985 to 2011. Most recent: operational control imposed, 14 January 2011.
Inspection history · 38
6 January 2011
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3921781
14 May 2008
PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3206043
14 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3206140
11 May 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3203536
23 December 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3120322
16 December 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3116562
3 October 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3071449
24 July 2007
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3003539
18 July 2007
Random ISPS/MTSA-No PSC
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2999671
3 May 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2920602
29 April 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2917984
6 September 2006
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2769827
17 January 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 285987
13 March 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 275601
2 December 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 435416
5 February 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 425176
22 November 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 423006
28 October 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 409250
25 June 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 404943
1 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 391630
19 May 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 378392
7 June 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 367477
13 March 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 365213
19 August 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 360275
24 June 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359070
10 May 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 358136
2 October 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 521163
19 January 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 341424
23 October 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 507644
10 January 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 334695
27 February 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 328732
5 February 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 494138
14 December 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 327336
23 June 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 457458
3 December 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 319968
5 April 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 446263
8 November 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 312511
2 October 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 305001
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 January 2011
Resolved
0750 - Fire Prevention - Fire protection systems shall be maintained ready for immediate use. The PSCO discovered that two remote fuel shut off valves from the HFO and DO tanks were disabled. - SOLAS 74a II-2/14
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 21 January 2011
Resolution: Received, reviewed and accepted class report from RINA stating the deficiency was rectified. Valves were repaired and tested satisfactorily.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 January 2011
Resolved
0750 - Fire Prevention - The maintenance plan shall include at least the following fire protection systems, fire-fighting systems and appliances, where installed: emergency shutdown of fuel supply. PSCO inquired with C/E as to his maintenance plans, testing procedures and periodicity to which he stated he had no knowledge of any for the fuel supply emergency shutdowns.
- SOLAS 74a II-2/14
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 21 January 2011
Resolution: Received, reviewed and accepted class report from RINA stating the deficiency was rectified. ISM audit was conducted, maintenance plans found in compliance.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 6 January 2011
Resolved
0750 - Fire Prevention - If a fire in any one compartment could put all fire pumps out of action, there shall be an alternative means of providing water for fire-fighting. Captain stated that the emergency fire pump had sustained a substantial leak so the pump was disassembled for repair. - SOLAS 60un CH. 2 reg. 65
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2011
Resolved 21 January 2011
Resolution: Received, reviewed and accepted class report from RINA stating the deficiency was rectified. Packing was replaces and the motor landed ashore for repairs by ALPHA MAR-INW. After reinstallation the pump was tested using two hoses with satisfactory results
Stability › Weathertight Integrity › General
Issued 6 January 2011
Resolved
1240 - Cargo and other hatchways - Upon the catastrophic failure of the #4 cargo handling crane the jib fell onto the #4 cargo hatch cover resulting in a two inch by two inch hole penetrating into the cargo area.
- ILLC reg. 16
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2011
Resolved 21 January 2011
Resolution: Received, reviewed and accepted class report from RINA stating the deficiency was rectified. The hole was temporarily repaired with a doubler plate. Imposed a condition of class to make permanent repairs prior to 20 March 2011.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 6 January 2011
No resolution recorded
1150 - Loading and unloading equipment - The #4 cargo handling crane experienced a catastrophic failure causing the jib to fall and severed a cable. Provide documentation to the satisfaction of the administration attesting to the cause of the failure and proper repair prior to cargo operations in the cargo hold.
- ILO 147
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2011 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 29 April 2007
Resolved
Vessel loss propulsion while transiting HSC.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2007
Resolution: Received satisfactory class report.
Navigation
Issued 2 December 1999
Resolved
THE VESSEL DEPTH SOUNDER RECORDER WAS INOPERABLE IN VIOLATION OF 33 C.F.R.164.35(i).
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Fire Fighting
Issued 25 June 1997
Resolved
ONE FIREMANS SUIT HAD THE FIRE RESISTANT MATERIAL WORN OFF OF IT.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Navigation
Issued 25 June 1997
Resolved
UPON ARRIVAL FOR THE INSPECTION THE STEERING GEAR SYSTEM WAS TAKEN APART._x001C_ THE SYSTEM WAS NOT AVAILABLE FOR INSPECTION. THE SYSTEM WAS THEN PUT BACK _x001C_TOGETHER AND TESTED. THE TEST WAS COMPLETED AND WAS SHOWN THAT IT WAS IN GOOD WORKING ORDER.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 25 June 1997
Resolved
CHIEF ENGINEER COULD NOT PROPERLY OPERATE THE OILY WATER SEPERATOR.
Condition: Unknown
Due 25 June 1997
Resolved 26 June 1997
Navigation
Issued 1 June 1996
Resolved
Vessel missing steering telex linkage safety Hardware.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Navigation
Issued 1 June 1996
Resolved
Boarding Officers noted that the steering compartment had improperly storedoxidizers in the steering compartment.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 10 January 1990
Resolved
FLAMES SCREENS NOT PROPERLY INSTALLED ON FUEL OIL AND LUBE OIL VENTS.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Navigation
Issued 14 December 1988
Resolved
NO APPROVAL LABEL ON VESSEL'S ARPA AS REQUIRED BY 33CFR164.38(D)(1).
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988