MAURY USCG vessel records Sign in
← All vessels

BALTIC PROSPERITY

BALTIC PROSPERITY is a 1984 freight ship. The Coast Guard has recorded 20 inspections since 1986, most recently in March 2007, along with 71 deficiencies.

Records from 1986 to 2007. Most recent: inspection, 7 March 2007.

Built
1984
Last inspected
7 March 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8319093 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
259090
Flag
PANAMA
—
Maury page id
psix-259090

Inspections, by type

…with no type recorded13
Years with a record 11 calendar years (1986–2007)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it5307 - Convention (Subpart B), Gross Ton
2915 - Convention (Subpart B), Net Ton
6310 - Dead Weight, Ton
9756 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

7 March 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883375
14 July 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2418803
3 July 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2412814
12 November 2004 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2239361
29 March 2004 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2033002
16 March 2004 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2025642
17 August 2002 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1661632
21 July 2000 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 280168
3 July 2000 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 279557
7 January 2000 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 273415
11 February 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425444
11 August 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 652649
4 August 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 360090
13 July 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 651680
15 June 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 450677
8 August 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 331937
28 September 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 318731
21 September 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 318591
15 September 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 318444
7 October 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 311732

Deficiency record · 71

Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 July 2005 Resolved
Steering gear room missing suitable arrangements for a safe work environment to include non-slip surface from entrance of doorway to working area. SOLAS Ch. II-1 reg. 29 / 13.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 August 2005
Resolved 6 December 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 14 July 2005 Resolved
Two unsound patches on discharge piping to boiler/toilet service pump. SOLAS 74 Chap. II-1 Reg 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 14 July 2005 Resolved
Drain line from galley has cement patch on overboard discharge valve. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2005 Resolved
Unsound patch on generator salt water cooling line next to lube oil separator. SOLAS 74 Chap. I Reg.11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2005 Resolved
Unsound patch on salt water suction line to generator found under ship service generator cooling pump. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Deck/Cargo › Cargo Refrigeration › General
Issued 14 July 2005 Resolved
Unsound patch on refrigeration line in way of second level, forward engine room. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Freshwater Generation System › Piping
Issued 14 July 2005 Resolved
Three unsound patches found in way of generator fresh water cooler. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 14 July 2005 Resolved
Leaking unsound patch made of twine on piping from generator to fuel sludge tank. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Deck/Cargo › Cargo Refrigeration › General
Issued 14 July 2005 Resolved
Unsound patch found above #1 and #2 reefer pumps. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Deck/Cargo › Cargo Refrigeration › General
Issued 14 July 2005 Resolved
Unsound patch found on pipe above #3 reefer power panel. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Freshwater Generation System › Piping
Issued 14 July 2005 Resolved
Six unsound patches in way of fresh water supply piping to cabins found above blended oil tank. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 14 July 2005 Resolved
Unsound patch on hot water piping for hotel services found above escape ladder in way of engine room. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Freshwater Generation System › Piping
Issued 14 July 2005 Resolved
Unsound patch found on bottom side of main engine fresh water cooler. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Fire Fighting › Means of Escape › Blocked
Issued 14 July 2005 Resolved
Work bench partially blocking ladder preventing safe egress from engine room. SOLAS Ch. II-2 reg. 13
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2005
Resolved 6 December 2006
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 14 July 2005 Resolved
Unsound patch made of twine in way of shower drain line in engine room. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 14 July 2005 Resolved
Unsound patch on drain line near frame 36, port side forward. SOLAS 74 Chap. I Reg. 11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 14 July 2005 Resolved
Galley drain line replaced and rerouted with flexible hose. SOLAS 74 Chap. I Reg. 11.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 6 December 2006
Documentation › Markings/Placards › Oil Discharge Placard
Issued 16 March 2004 Resolved
Provide Oil Pollution Placard prior to next U.S. Port
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 12 November 2004
Resolution: During the course of the engine room inspection the boarding team noted that the vessel had a Oil Pollution Placard posted.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 16 March 2004 Resolved
Containment boxes by Port 3C3A, 4 Port 4C, and 3 starboard are in need of welding. LEGACY COMPONENT DESC: Coamings
Action required: 15 - Rectify deficiencies by next port
Due 16 March 2004
Resolved 12 November 2004
Resolution: During the course of the deck inspection, the boarding team noted that the containment boxes had been welded as needed.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 March 2004 Resolved
Install machinary guards on all ship service generators between prime mover and generator area. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Resolved 24 March 2004
Resolution: RCVD REPORT FROM CLASS SOCIETY ( NKK ) STATING THAT MACHINERY GUARD IS NOT NECESSARY.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 March 2004 Resolved
Upper level of enginroom the handrails were broken LEGACY COMPONENT DESC: Hand Grab
Condition: Damaged By Earlier Event
Due 15 April 2004
Resolved 12 November 2004
Resolution: During the course of the engine room inspection, the boarding team noted that the handrails had been fixed.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 16 March 2004 Resolved
missing oil pollution placard in enginroom space
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 12 November 2004
Resolution: During the course of the engine room inspection, the boarding team noted that the oil pollution placard had been posted.
Documentation › Certificates/Documents
Issued 17 August 2002 Resolved
Vessel owner must provide documentation indicating role of Harp Marine LTD, listed as operator on the Certificate of Financial Responsibility. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2002
Resolution: Harp Marine LTD. is Owner and Operator.
Lifesaving › Launching Appliances
Issued 17 August 2002 Resolved
The air connections to both port and stbd limit switches are wasted and must be replaced. LEGACY COMPONENT DESC: Davit
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2002
Resolution: Replaced.
Fire Fighting
Issued 21 July 2000 Resolved
Renew leaking fire main piping in engine room. Fire main vertical piping next to engine control room.
Condition: Unknown
Due 21 August 2000
Resolved 17 August 2002
Fire Fighting
Issued 3 July 2000 Resolved
Renew leaking fire main piping in engine room. Leaks are in two places, 1)lower level near GS pump in the fire main elbow overhead 2) fire main vertical piping next to engine control room.
Condition: Unknown
Due 21 July 2000
Resolved 21 July 2000
Engineering
Issued 7 January 2000 Resolved
Renew fuel oil containment, forward of #1 cargo hatch.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Accommodation/Occupational Safety
Issued 7 January 2000 Resolved
Provide portable toilets until ship's toilets and MSD are operable.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 January 2000 Resolved
Prove proper operation of MSD and toilets.
Condition: Unknown
Due 6 February 2000
Resolved 7 March 2000
Unknown
Issued 7 January 2000 Resolved
Renew leaking hydraulic line for cargo hatch #1, port side of #1 cargo hold.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 January 2000 Resolved
Make permanent repairs to bilge/ballast fire pump suction (port side).
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 7 January 2000 Resolved
Make permanent repair to slight leak on air conditioning overboard flange to hull weld, forward port side engine room.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Stop excessive leaking from fire and bilge pump shaft packing.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 7 January 2000 Resolved
Renew dog on hatch on the port side of #2 cargo hold.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Renew leaking deck wash line, port side, connected to fire main.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Documentation
Issued 7 January 2000 Resolved
Provide original valid cargo ship safety equipment record form E.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Make permanent repair to leak in fire pump suction piping.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Prove that emergency fire pump provide 2 jets of water as required by SOLAS74 CH II-2/52.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Conduct fire drill to satisfaction of U.S.C.G.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Lifesaving
Issued 7 January 2000 Resolved
Conduct boat drill to satisfaction of U.S.C.G.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Engineering
Issued 7 January 2000 Resolved
Stop fuel leak on emergency fire pump.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Engineering
Issued 7 January 2000 Resolved
Renew fuel oil containment, forward of #1 cargo hatch.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 January 2000 Resolved
Make watertight door to forward stores watertight.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Deck/Cargo
Issued 7 January 2000 Resolved
Renew wasted padeyes and shackles for both anchor stoppers.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Deck/Cargo
Issued 7 January 2000 Resolved
Renew guard on starboard, forward windlass brake.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 7 January 2000 Resolved
Make permanent repairs to leaking no. 1 saltwater service pump discharge pipe.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 January 2000 Resolved
Renew inoperable dogs on cargo hatches.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Engineering
Issued 7 January 2000 Resolved
Renew holed (2 places) ejector discharge pipe.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Accommodation/Occupational Safety
Issued 7 January 2000 Resolved
Make permanent repair to forward end of distilling plant tank.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Deck/Cargo
Issued 7 January 2000 Resolved
Stop excessive leaking on #2 and #3 cargo reefer condensor pumps.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Accommodation/Occupational Safety
Issued 7 January 2000 Resolved
Renew holed MSD overboard piping.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Fire Fighting
Issued 7 January 2000 Resolved
Make permanent repair to fire main next to engine cotrol (veritical piping).
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Engineering
Issued 7 January 2000 Resolved
Repair lube oil leak on #2 generator.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Lifesaving
Issued 7 January 2000 Resolved
Renew line on bridge wing ring buoy.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Construction/Loadline
Issued 7 January 2000 Resolved
Repair holes in superstructure on #4 deck, aft.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Unknown
Issued 7 January 2000 Resolved
Remove oil in aft starboard containment.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Navigation
Issued 7 January 2000 Resolved
Log pre-arrival tests as required by 33 CFR 164.25.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Navigation
Issued 7 January 2000 Resolved
Provide current coast pilot and sailing directions.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Documentation
Issued 7 January 2000 Resolved
Have master sign oil record book pages.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Show location of international shore connection on fire control plan.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Electrical
Issued 7 January 2000 Resolved
Renew light covers throughout vessel.
Condition: Unknown
Due 6 February 2000
Resolved 17 August 2002
Engineering
Issued 7 January 2000 Resolved
Provide plugs for oil containment.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Accommodation/Occupational Safety
Issued 7 January 2000 Resolved
Remove means to pump raw sewage overboard while within 3 miles of U.S. shore.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 January 2000 Resolved
Pump ashore, to holding tank or discharge through properly operating MSD, sewage from backed up toilets.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 January 2000 Resolved
Conduct and log fire and boat drills as required by SOLAS 74 amended CH III.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Navigation
Issued 4 August 1993 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. CHART #12214 USED BY THE VESSEL WASNOT CORRECTED TO NTM 25/93, WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM CAPE HENLOPEN, DE TO WILMINGTON, DE.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Navigation
Issued 4 August 1993 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VESSELS U.S. CHARTS #12304, AND 12311 WERE NOT THE CURRENT EDITIONS AND WERE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Navigation
Issued 15 September 1987 Resolved
CHARTS 11412, 11413, 11414 WERE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Navigation
Issued 15 September 1987 Resolved
USCG LIGHT LIST WAS NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Navigation
Issued 15 September 1987 Resolved
U.S. COAST PILOT WAS NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Navigation
Issued 15 September 1987 Resolved
INLAND NAVIGATION RULES NOT ONBOARD VESSEL.
Condition: Unknown
Due 28 September 1987
Resolved 15 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.