Records from 1985 to 1990. Most recent: inspection, 13 March 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
13 March 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 335790
13 March 1990
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1225403
21 August 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 325903
21 August 1988
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344627
19 June 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 316742
22 April 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 315719
22 April 1987
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1327337
17 October 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305107
Deck/Cargo
Issued 13 March 1990
Resolved
CONDUCT HYDROSTATIC TEST OF ALL CARGO AND BUNKER PIPING TO ONE AND ONE HALFTIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 31 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 13 March 1990
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF INSTALLED OXYGEN METER ON INERT GAS SYSTEM.
Condition: Unknown
Due 31 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 13 March 1990
Resolved
REPLACE FLAME SCREENS ON ALL BALLAST AND FUEL OIL TANKS.
Condition: Unknown
Due 31 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 13 March 1990
Resolved
REPLACE THREE LINED 2 1/2" LINED FIRE HOSES.
Condition: Unknown
Due 31 December 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 13 March 1990
Resolved
REPACK/REPAIR FIRE HYDRANT AT PORT AFT CORNER OF #2 CARGO HATCH.
Condition: Unknown
Due 31 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 22 April 1987
Resolved
46 CFR 32.53-60 TEMPERATURE INDICATOR FOR THE INERT GAS SYSTEM NOT INSTALLED IN THE CARGO CONTROL ROOM, AS REQUIRED.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Deck/Cargo
Issued 22 April 1987
Resolved
46 CFR 32.53-60 TEMPERATURE,OXYGEN PRECENT & IG PRESSURE INDICATORS NOT INSTALLED IN THE LOCATION OF THE PERSON-IN-CHARGE OF THE MAIN PROPULSION MACHINERY, AS REQUIRED.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Deck/Cargo
Issued 17 October 1985
Resolved
33CFR156.120(P) REPAIR EXCESSIVE PRODUCT LEAK IN NR. 2 CARGO PUMP.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Deck/Cargo
Issued 17 October 1985
Resolved
REMOVE EXCESSIVE PRODUCT FROM CARGO PUMP ROOM BILGE.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Deck/Cargo
Issued 17 October 1985
Resolved
46CFR32.53-60 PLACE A SUITABLE TEMPERATURE INDICATOR FOR THE INERT GAS SYSTEM IN THE CARGO CONTROL ROOM.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Deck/Cargo
Issued 17 October 1985
Resolved
46CFR32.53-60 PLACE SUITABLE TEMPERATURE, OXYGEN PERCENT AND PRESURE GAUGESFOR THE INERT GAS SYSTEM IN THE ENGINE CONTROL ROOM.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985