← All vessels
ORIENTAL PHOENIX
Freight Ship · Ro-Ro Cargo Ship class · Built 1980s · USCG Oceania District (CGD-O) · Other hulls named ORIENTAL PHOENIX
ORIENTAL PHOENIX is a 1985 freight ship. The Coast Guard has recorded 27 inspections since 1985, most recently in October 2008, along with 19 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 1985 to 2008. Most recent: inspection, 15 October 2008.
- Built
- 1985
- Last inspected
- 15 October 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8405282 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELLZ4
259277
Flag
PHILIPPINES
—
Maury page id
psix-259277
Inspections, by type
…with no type recorded16
Years with a record
14 calendar years (1985–2008)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it27658 - Regulatory (Subpart C or D), Gross Ton
27658 - Convention (Subpart B), Gross Ton
8298 - Regulatory (Subpart C or D), Net Ton
8298 - Convention (Subpart B), Net Ton
11824 - Dead Weight, Ton
27658 - Convention (Subpart B), Gross Ton
8298 - Regulatory (Subpart C or D), Net Ton
8298 - Convention (Subpart B), Net Ton
11824 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
15 October 2008
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3344810
13 September 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3323606
8 January 2008
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3126676
24 February 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2298952
19 February 2005
Ballast Water Examination · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2295745
26 August 2004
NPV Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2175369
27 May 2004
MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2079630
11 May 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2064913
10 April 2004
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2041369
1 April 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2035651
26 December 2002
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1722994
17 November 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1704817
8 April 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 276341
20 August 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 431731
15 August 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 431596
7 November 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 422021
11 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 403644
1 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 530328
1 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 869342
25 September 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 339480
21 September 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 440807
3 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323070
7 April 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 322470
1 July 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 510321
26 November 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 312927
16 June 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 500873
28 October 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 305021
Deficiency record · 19
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 September 2008
Resolved
MSD is not Coast Guard approved.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 September 2008
Resolved
MSD does not have approved Coast Guard placard.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 September 2008
No resolution recorded
Non-tank Vessel Response Plan does not list Guam as approved COTP Zone.
Navigation › Piloting/Steering
Issued 11 May 2004
Resolved
Vessel requested LOD for inoperative Gyrocompass. Certified technicians report of repairs must be submitted to this office in writing when vessel is in compliance. LEGACY COMPONENT DESC: Gyro Compass
Electrical › Electrical Distribution System (emergency)
Issued 1 April 2004
Resolved
Emergency [name withheld] indicated a Ground. LEGACY COMPONENT DESC: Ground Detection
Engineering › Bilge Water Management System
Issued 1 April 2004
Resolved
Pipe from bilge pump is leaking. LEGACY COMPONENT DESC: Piping
Fire Fighting › Ventilation Systems
Issued 1 April 2004
Resolved
Fire damper closures inoperative. Dampers do not close after activating releasing mechanisms. LEGACY COMPONENT DESC: Operating Controls
Lifesaving › Launching Appliances
Issued 1 April 2004
Resolved
Port and STBD lifeboat winch mounting bolts are wasted. LEGACY COMPONENT DESC: Winch
Electrical › Lighting (service)
Issued 17 November 2002
Resolved
Broken Light fixture after steering LEGACY COMPONENT DESC: Lighting Fixture
Accommodation/Occupational Safety › Ventilation
Issued 17 November 2002
Resolved
Exhaust fan CO2 room duct wasted
Construction/Loadline
Issued 8 April 2000
Resolved
Prove operation of all weathertight doors on the accommodation deck.
Engineering
Issued 8 April 2000
Resolved
Ensure all fuel tank vent containments meet the holding capacity requirements as required by 33 CFR 155.320(a).
Lifesaving
Issued 8 April 2000
Resolved
Replace all ring buoy grab lines and throw lines that are deteriorated._x001C_ SOLAS 74 Amended III/ 31.
Documentation
Issued 8 April 2000
Resolved
Update fire control plan to include fire station 8, second deck. SOLAS 74 Amended II/ 20.
Lifesaving
Issued 15 August 1999
Resolved
0001) Per SOLAS AMENDED, CH-3,REG 31/1.6,lifebuoys on Port/Stb. bridge wings are under 4kg weight, and thus insufficient mass to operate quick- release arrangement for self-activating smoke signals and self-igniting lights.
Navigation
Issued 7 November 1998
Resolved
LOCAL AREA NAVIGATION CHARTS (18474 AND 18450) WERE NOT CURRENTLY CORRECTEDIN ACCORDANCE WITH 33CFR164.33_x001C_ CORRECT PRIOR TO NEXTSEATTLE PORT CALL
Fire Fighting
Issued 11 May 1997
Resolved
LOW PRESSURE CO2 SYSTEM LAST SERVICED 18MAY93.
Navigation
Issued 7 April 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33 (A)(1)(II) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS IAW 33 CFR 164.33(B).
Navigation
Issued 7 April 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH U. S. COAST PILOT NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33 (A)(2)(I) OR AN EQUIVALENT FOREIGN GOVERNMENT PUBLICATION IAW 33 CFR 164.33(B).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.