MAURY USCG vessel records Sign in
← All vessels

BANA

BANA is a 1980 freight ship. The Coast Guard has recorded 30 inspections since 2001, most recently in November 2008, along with 31 deficiencies and 7 operational controls.

Records from 2001 to 2008. Most recent: inspection, 12 November 2008.

Built
1980
Last inspected
12 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7920857 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MALAYSIA
—
Maury page id
psix-26037

Inspections, by type

…with no type recorded17
Years with a record 7 calendar years (2001–2008)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it7049 - Displacement, Ton
3787 - Dead Weight, Ton
9367 - Convention (Subpart B), Gross Ton
3835 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

12 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3361552
5 July 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2984620
28 October 2006 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2809733
8 August 2006 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2740511
25 May 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2658407
29 April 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2636554
14 April 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2624883
12 March 2006 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2601041
1 November 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2526263
8 October 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2510489
7 September 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486165
7 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486432
2 September 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2481609
20 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2433343
6 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2416670
20 June 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2396684
19 June 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2395005
24 January 2005 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278031
20 December 2004 Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2262709
8 August 2004 PII Safety Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2151122
28 June 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2108411
25 February 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2012646
9 February 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2002853
10 January 2004 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1924957
9 June 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1812863
23 July 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1069297
14 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 291022
30 May 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 640510
29 May 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 290538
17 May 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 290209

Deficiency record · 31

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 March 2008 Resolved
The nontank VRP Interim Operating Authorization expired 7/6/07. The owner/operator has failed to verify the status of the vessel and/or recertify that response resources are capable of responding to the maximum extent practicable, to a worst case discharge.
Due 14 April 2008
Resolved 15 January 2009
Resolution: NTVRP plan #03192 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Lifesaving › Launching Appliances › Davit
Issued 28 October 2006 Resolved
Limit switch for stbd side lifeboat not working properly
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 November 2006
Resolution: Inspected,Test Sat
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 August 2006 Resolved
Emergency fire pump motor exhuast pipe is leaking into steering space. Repair or replace to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 23 August 2006
Resolution: Received class report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 August 2006 Resolved
Overboard discharge line to oily water separator has a soft patch. Repair or replace to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 23 August 2006
Resolution: Received class report.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 8 August 2006 Resolved
Install non-skid material around steering gear to the satisfaction of US Coast Guard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 23 August 2006
Resolution: received class report.
Electrical › Electric Generation Source (service) › Generator
Issued 8 August 2006 Resolved
#1 Generator is inoperative and can't carry the load. Make repairs to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2006
Resolved 1 October 2006
Resolution: Received class report. The No.1 diesel generator has been overhauled; tested under full load conditions and found operating satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 8 August 2006 Resolved
#1 Generator has temporary repair to fuel line. Make permanent repairs to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2006
Resolved 1 October 2006
Resolution: Received class report. No.1 diesel generator''s section of fuel line has now been renewed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 August 2006 Resolved
Auxillary generator upper deck aft installation. Cables from generator ran through a watertight door and through an emergency escape from the engine room. Have class approve operation of auxillary generator and provide class report to USCG [name withheld]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2006
Resolved 8 August 2006
Resolution: Received class report. Electric cables from the Aux generator have been re-routed and passed through W/T opening in the funnel plating.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 April 2006 Resolved
Primary radar, x-band 9ghz is not operational. Repair and prove proper operation of radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2006
Resolution: Received technician report attesting to proper repair of radar.
Engineering › Steam System (main) › Piping
Issued 7 September 2005 Resolved
1499 Make permanent repairs to steam return line above #1 generator to satisfaction of class. 50a.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 8 October 2005
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 7 September 2005 Resolved
0399 Repair or replace exhaust opening for ships refrigerator in aft galley bulkhead. 50a.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 8 October 2005
Lifesaving › Lifeboat › Hull
Issued 20 December 2004 Resolved
Port and stbd lifeboats gunwales damaged in way of gripes . Make permanent repair to lifeboats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 7 September 2005
Resolution: Def checked during AEF. Def CLeared.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 20 December 2004 Resolved
Port lifeboat rudder damaged in way of tiller fitting. Make permanent repair to fitting and prove proper tiller fit operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2004
Resolution: Received class surveyor report attesting to proper repairs
Electrical › Electric Generation Source (service) › Generator
Issued 20 December 2004 Resolved
Ship service generator #2, not operational. Provide proper operation of generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2004
Resolution: Received report from class surveyor attesting to an alternated means (portable 500kw generator) of power until they overhaul the generators.
Electrical › Electric Generation Source (service) › Generator
Issued 20 December 2004 Resolved
Ship service generator #1 not able to carry required load, trips off line, vessel blacked out. Prove proper operation of generator under rated load
Action required: 705 - Other - as specified
Due 21 January 2005
Resolved 23 December 2004
Resolution: Received report from class surveyor attesting to sat operation of generator
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 20 December 2004 Resolved
Bunker oil tank vent wasted and holed. Make permanent repairs to vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2005
Resolved 11 February 2005
Resolution: Temporary repair completed
Construction/Loadline › Structures › Air Pipe
Issued 20 December 2004 Resolved
CO2 room deck air vent wasted & holed. Make permanent repairs to vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 January 2005
Resolved 21 January 2005
Resolution: Received class report attesting to repairs.
Fire Fighting › Fire Hydrants › Location/Position
Issued 20 December 2004 Resolved
Fire hydrant and portable fire extinguisher inaccessable on B deck. Remove obstructions and provide clear access to fire station and portable extinguisher.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2004
Resolution: Received confirmation from GL class society rep. acting for BV requirement "dealt with".
Electrical › Lighting (service) › Lighting Fixture
Issued 20 December 2004 Resolved
CO2 room light fixture broke. Renew light fixture and prove proper operation
Action required: 705 - Other - as specified
Due 21 January 2005
Resolved 23 December 2004
Resolution: Light fixture repaired and found satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 December 2004 Resolved
Stbd CO2 room lighting out. Restore proper lighting in room.
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 23 December 2004
Resolution: Lighting restored to starboard CO2 room. Tested and found satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 20 December 2004 Resolved
Vessel transom holed & cracked in way of port side shell transom weld steering gear flat. Make permanent repair to damaged area.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2004
Resolution: Temporary repair effected. Condition of class given to make permanent repair.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 December 2004 Resolved
Excess oil in engine room bilges. Drums stowed in lower level engine room. Remove oil from bilges & remove waste oil drums. Provide receipt for waste oil removed from approved oil facility.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2004
Resolution: Received notification from class 7000 gallons of oil delivered ashore. Receipt to follow.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 20 December 2004 Resolved
Stbd inflatable liferaft missing identification paper from tube. Provide required raft id paper in tube.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2004
Resolved 23 December 2004
Resolution: Class confirmation. "dealt with"
Documentation › Certificates/Documents
Issued 10 January 2004 Resolved
Vessel's SOLAS exemption Certificate for Radio Direction Finder was expired. Vsl's class/flag to address issue LEGACY COMPONENT DESC: Exemption Certificate (SOLAS)
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 9 February 2004
Resolution: Vsl not required to have SOLAS exemption cert any longer. GPS installed and noted in form "E" of Cargo Ship Safety Certificate
Lifesaving › Inflatable Liferafts
Issued 10 January 2004 Resolved
Vessel's SEC stated vsl to have 50 person accomodation for liferafts. Vsls liferafts can accomodate only 41. Class/Flag to address issue. Vsl allowed to sail as only 17 crewmembers on board LEGACY COMPONENT DESC: Capacity
Action required: 705 - Other - as specified
Due 10 February 2004
Resolved 25 February 2004
Documentation
Issued 29 May 2001 Resolved
Vessel failed to obtain a COTP permit prior to entering anchorage F.
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001
Fire Fighting
Issued 17 May 2001 Resolved
Vessel's emergency fire pump has two soft patches (one on the discharge line and one on the suction line) and pump does not provide adequate water pressure. Permanent repairs must be made to the pump and proper operation of the pump to be conducted/verfied by the vessel's Class Society (NKK).
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Lifesaving
Issued 17 May 2001 Resolved
Replace/Renew broken liferail on starboard side lifeboat to the satisfaction of class.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Lifesaving
Issued 17 May 2001 Resolved
Replace/Renew rottd lifeline on starboard side lifeboat to satisfaction of class.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Lifesaving
Issued 17 May 2001 Resolved
Replace/Renew severly corroded pipes that protect wiring for lifeboat lowering control panel.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Accommodation/Occupational Safety
Issued 17 May 2001 Resolved
Vessel to provide adequate light fixtures in the toilet facility and showerroom.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.