Records from 1995 to 2019. Most recent: inspection, 16 January 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
16 January 2019
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6611045
14 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580520
17 April 2018
Type not recorded
No type recorded · USCGC KINGFISHER (WPB 87322) · USCG Southeast District (CGD-SE) · Activity 6394064
5 February 2018
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6346210
8 February 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6081966
16 November 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6040523
22 February 2016
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815248
20 March 2014
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 4819926
22 February 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4248066
7 December 2011
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4203046
14 December 2010
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3908517
15 March 2010
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3694521
23 March 2009
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3435728
15 December 2008
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3378721
3 March 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3155407
14 March 2007
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2966208
18 January 2007
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2857929
1 February 2006
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2577304
23 February 2005
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2297705
1 December 2004
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2251115
3 March 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2017179
25 February 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2012014
19 February 2003
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1746463
4 December 2002
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1715338
10 April 2002
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1603701
28 March 2001
Administrative
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1454916
16 February 2001
Inclining Experiment
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1373335
6 February 2001
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1422021
1 February 2001
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1074569
8 January 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412225
12 April 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1057505
17 February 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473337
1 February 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1365045
4 March 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378293
6 March 1997
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453323
11 March 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1466962
27 March 1995
Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394308
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 February 2018
Resolved
Replace Retroreflective material on 3x life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 7 February 2018
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 February 2018
Resolved
Replace retroreflective material on the vessel's life float and life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 7 February 2018
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 22 February 2016
Resolved
Provide emergency lighting for accomodation space egree
Action required: 705 - Other - as specified
Due 6 March 2016
Resolved 23 February 2016
Resolution: Vessel replaced emergency lighting
Construction/Loadline › Hull › Side Shell
Issued 14 December 2010
Resolved
Repair blisters marked on the port side of the keel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 December 2010
Resolved
Seal wire runs through forward transverse bulkhead in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2010
Construction/Loadline › Penetrations › Valve Flange
Issued 14 December 2010
Resolved
Remove PVC pipe & cap thru hull fitting in lazerette (port side).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 December 2008
Resolved
Repair/Replace port and starboard stringer as need based on core sampling to good structural wood, IWO lazarette.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2009
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 December 2008
Resolved
Upon completion of item #1 provide repair proposal to MSD Panama City with type, location, and schedule based on findings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 1 February 2006
Resolved
Provide B-I & B-II portable fire extinguishers as indicated on COI as required by 46 CFR 176.810.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2006
Resolved 1 February 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 1 February 2006
Resolved
Install smoke detection unit in forward accommodation space as required by 46 CFR 176.810(a)(7).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2006
Resolved 1 February 2006
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 1 February 2006
Resolved
Renewcwasted links in anchor chain as as per 46 CFR 184.300.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2006
Resolved 1 February 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 February 2005
Resolved
Provide visual alarm for bilge pump. 46 CFR 182.530c.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 9 March 2005
Documentation › Certificates/Documents › FCC SSL
Issued 23 February 2005
Resolved
Obtain FCC station license. 47 CFR 80.13.
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 9 March 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 February 2005
Resolved
Obtain light list and tide/tidal current tables. 46 CFR 184.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 9 March 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 February 2005
Resolved
Replace and date batteries for floating electric water lights on life float and ring lifebuoy. 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 9 March 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 February 2005
Resolved
Obtain 18-foot lanyard for floating electric water light on life float. 46 CFR 180.200.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 9 March 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2005
Resolved
Obtain first aid kit 46 CFR 184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2005
Resolved 9 March 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 February 2005
Resolved
Install adequate emergency lighting to illuminate means of escape from passenger accommodations below main deck.
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 9 March 2005
Navigation › Collision/Grounding Avoidance
Issued 25 February 2004
Resolved
Renew stbd running light IAW 46 CFR 183.420. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 25 March 2004
Resolved 3 March 2004
Resolution: Owner renewed stbd running light.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2004
Resolved
Mark means of escape both sides IAW 46 CFR 185.606. LEGACY COMPONENT DESC: Means of Escape
Due 25 March 2004
Resolved 3 March 2004
Resolution: Owner marked means of escape-both sides.
Lifesaving › Rigid Liferafts
Issued 25 February 2004
Resolved
Renew water light on lifefloat prior to carrying passengers LEGACY COMPONENT DESC: Water Light
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2004
Resolved 3 March 2004
Resolution: Owner renewed waterlight on lifefloat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 February 2004
Resolved
Renew lifejacket lights IAW 46 CFR 180.75 LEGACY COMPONENT DESC: Lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2004
Resolved 3 March 2004
Resolution: Owner renewed lights on lifejackets.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 February 2004
Resolved
Renew retro on lifejacket identified by Inspector. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2004
Resolved 3 March 2004
Resolution: Owner renewed retro on lifejackets.
Engineering › Fuel Oil Service System
Issued 25 February 2004
Resolved
Install hose clampon SSDG F/O line. LEGACY COMPONENT DESC: Hose Clamp
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2004
Resolved 3 March 2004
Resolution: Owner installed hose clamp.
Engineering › Steering Gear System
Issued 4 December 2002
Resolved
Renew rudder bearing. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 January 2003
Resolved 12 December 2002
Resolution: Owner renewed rudder bearing.
Navigation
Issued 6 February 2001
Resolved
DEMONSTRATE PROPER OPERATION OF SHIP'S WHISTLE IAW 33CFR86.
Condition: Unknown
Due 6 March 2001
Resolved 2 March 2001
Navigation
Issued 6 February 2001
Resolved
PROVIDE FCC SAFETY CERTIFICATE IAW 47CFR80, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 March 2001
Resolved 2 March 2001
Fire Fighting
Issued 6 February 2001
Resolved
PROVIDE FIXED FIRE FIGHTING CERTIFICATES IAW 16CFR810(B)(2), PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 6 March 2001
Resolved 2 March 2001
Lifesaving
Issued 6 February 2001
Resolved
PROVIDE ON BOARD DISTRESS SIGNALS IAW 46CFR180.68, PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 6 March 2001
Resolved 2 March 2001
Navigation
Issued 6 February 2001
Resolved
PROVIDE ON BOARD REQUIRED PUBLICATIONS, INCLUDING TIDE AND CURRENT TABLES, COAST PILOT, AND LIGHT LIST, IAW 46CFR184.420.
Condition: Unknown
Due 6 March 2001
Resolved 2 March 2001
Electrical
Issued 8 January 2001
Resolved
PROVIDE SHOCK PROTECTION ON BATTERY CUTOUT SWITCH AND BATTERY BOX COVERS IAW 46 CFR 183.350
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Electrical
Issued 8 January 2001
Resolved
STRAP ELECTRICAL CABLES THROUGH OUT IAW 46 CFR 183.340
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Engineering
Issued 8 January 2001
Resolved
INSTALL MACHINERY GUARDS ON SSDG IAW 46 CFR 177.960
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Electrical
Issued 8 January 2001
Resolved
PROVIDE CABLE PROTECTION ON SSDG IAW 46 CFR 183.340
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001