← All vessels
ATLANTIC EXPRESS
Freight Ship · Bulk Carrier class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named ATLANTIC EXPRESS
ATLANTIC EXPRESS is a 1985 freight ship. The Coast Guard has recorded 92 inspections since 1985, most recently in December 2011, along with 143 deficiencies and 11 operational controls.
Records from 1985 to 2011. Most recent: inspection, 17 December 2011.
- Built
- 1985
- Last inspected
- 17 December 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 143 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8412223 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EFO4
261641
Flag
PANAMA
—
Maury page id
psix-261641
Inspections, by type
…with no type recorded72
Years with a record
27 calendar years (1985–2011)
The 92 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it15284 - Convention (Subpart B), Gross Ton
6690 - Convention (Subpart B), Net Ton
23924 - Dead Weight, Ton
30432 - Displacement, Ton
6690 - Convention (Subpart B), Net Ton
23924 - Dead Weight, Ton
30432 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 92
17 December 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4209885
12 December 2011
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4206626
12 August 2011
Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4109686
1 August 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4101949
22 November 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3896299
22 November 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3911980
29 January 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3668622
10 December 2009
COE-Dockside
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3647839
20 July 2009
ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3540312
27 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3437510
5 December 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3375281
15 August 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3299608
12 August 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3296126
11 July 2008
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3264436
4 April 2008
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3177434
10 March 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3161729
25 January 2008
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3136197
15 January 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3131221
16 May 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2931849
14 May 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2930164
9 May 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2925797
25 January 2006
Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 2575961
7 November 2005
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2530034
28 September 2005
MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · STCW 95 Exam · ILO-147 Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2503116
27 September 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2502365
24 September 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2503643
14 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2334186
10 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2330713
30 September 2004
ISPS II Exam · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2210905
7 October 2003
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1923207
16 September 2003
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1906228
19 June 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1827372
9 June 2003
Deficiency Check · Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1813922
30 May 2003
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1805647
8 November 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1701348
6 November 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1701834
1 January 2002
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1474637
1 November 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 295000
4 June 2001
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 290571
4 June 2001
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 523582
16 April 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 289143
2 April 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 288715
5 May 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 277580
14 March 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 275845
24 January 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 273838
31 August 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 431563
13 June 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 48847
25 May 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 184232
18 March 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 426647
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 29823
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424649
25 August 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 419560
2 March 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 519286
18 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 410889
29 September 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 408400
29 September 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 692194
22 August 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 407042
26 April 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400727
30 January 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 399904
12 December 1996
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 399242
3 December 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 398930
19 November 1996
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 397662
30 October 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 396966
18 June 1996
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 392395
15 April 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 390091
12 April 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 389881
16 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 386835
30 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384313
21 June 1995
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 472045
8 December 1994
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 373292
14 November 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 491226
2 December 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 362854
12 November 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 362216
28 February 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 356617
11 December 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 354980
8 November 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 354388
16 June 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 351420
9 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 350723
25 February 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 655492
6 February 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348712
25 July 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 501136
24 January 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 341484
15 December 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 491029
24 February 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 335445
5 September 1989
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 484202
11 February 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 328818
9 February 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 321212
26 May 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 480151
10 November 1986
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 312672
22 June 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 452358
15 November 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305712
22 October 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305633
Deficiency record · 143
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 August 2011
Resolved
1730 OWS was found with 24 inch crack on 2nd stage tank. Class must inspect prior to use of OWS. Due to cargo hold cleaning, bilge water tank does not have the capacity left to hold oily water. Vessel must remove oily waste prior to shifting to Stockton, CA.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 August 2011
Resolved
1499 The following patches were found during the inspection of the engine room: 1) S/W discharge line for ballast 2) Generator S/W air compressor discharge 3) S/W outlet line for lube oil cooler 4) Outlet line for F/W generator 5) Main engine S/W cooler inlet 6) Main engine S/W cooler outlet (4 inch X 3 inch )
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 August 2011
Resolved
0981 During the engine room inspection, three bent frames were found on starboard forward bulkhead near Fuel Oil Purifier aft of topside tank number four.
Construction/Loadline › Structures › Manhole
Issued 12 August 2011
Resolved
1299 The following load line discrepancies were found during the inspection: 1) Hole in forward corner of house on port side on the main deck. 2) Watertight door to FWD bosun stores on STBD side is not weather tight. 3) All covers to entrance of topside tanks are warped, have no gaskets and bolts are missing. 4) covers for FWD peak tanks are not secure. 5) Covers to chain lockers are not secure.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 12 August 2011
Resolved
0600 release device for both life boats is disconnected. Not sure how crew will release the boats. Manufactures booklet for life boats is not on board.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 12 August 2011
Resolved
0600 Exhaust muffler for life boat engines is not covered with insulation for crew protection. Mufflers are too short and will cause exhaust gas to blow in the coxswain face.
Lifesaving › Immersion Suits › General
Issued 12 August 2011
Resolved
0600 Immersion suit for second mate is too small. Appropriate size must be provided.
Lifesaving › Inflatable Liferafts › Approval
Issued 12 August 2011
Resolved
0620 Life raft forward is for sixteen person. Safety equipment certificate and safety drawing shows six person. Class surveyor must inspect and advise.
Lifesaving › Lifeboat Equipment › Oar
Issued 12 August 2011
Resolved
0600 The following items were found on both life boats. 1) Buoyant oars, wastage at end of blade. 2) Crutches not attached by lanyard or chain.3) Sea anchors are oil soaked.4) Emergency drinking water is in patched and previously used containers. 5) fire extinguishers are below pressure.6) Bowsing tackle blocks wasted, unsuitable.7) Canopy support bars inadequate.8) Skates are wasted and damaged
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 12 August 2011
Resolved
0600 The embarkation ladders for the life boats are three meters too short.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 August 2011
Resolved
1999 Every ship of 400 gross tons and above shall carry a garbage management plan the crew shall follow. Mixed garbage was found in every receptacle regardless of designated markings or color.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 12 August 2011
Resolved
1999 Shipboard incineration shall be allowed only in a shipboard incinerator. Two burn barrels are located on the stern, starboard side. Many items including aerosol cans, flash lights, paper, plastics, metal cans and glass were found.
Pollution Prevention/Response › Response Equipment › Containers
Issued 12 August 2011
Resolved
1999 The disposal of plastic into the sea, which may contain toxic or heavy metal residue is prohibited. The crew is covering the life rafts with plastic garbage bags for protection and did not remove the plastic after cargo operations. Due to natural elements the plastic bags deteriorated and fell into the water. In addition ash containing plastic residue from the burn barrels blowing into the..
Documentation › Markings/Placards › Oil Discharge Placard
Issued 12 August 2011
Resolved
0199 Vessel is required to have a placard in accordance with 33CFR155.450 Vessel's pollution placard is no longer valid due to the fine amount. 10c
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 12 August 2011
Resolved
0950 All electrical components must be installed as to not cause injury or shock. The batteries in the battery room are not secured for sea. 10c
Pollution Prevention/Response › Response Equipment › Containers
Issued 12 August 2011
Resolved
1999 The party shall take such steps as will ensure that the ship will not sail until the situation has been brought to order in accordance with MARPOL Annex V. There are excessive amounts of garbage of various types throughout the ship. All garbage must be removed from the vessel, this includes paper, plastic, metal, ash, pyrotechnics, ETC
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 12 August 2011
Resolved
0695 The SOLAS training manual provided shall contain instructions for systems and equipment specific to the vessel. The training manual found onboard did not have ship specific information. SOLAS III/51 10c
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 August 2011
Resolved
0700 The following discrepancies were found with the vessel's fire control actions: 1) Spare firefighting equipment is not stowed properly. 2) Training firefighting equipment is not marked "For Training " 3) Main fire line by cargo hold #2 is patched.
4) Natural air vent closures throughout the ship are inoperable. 5) Explosion cover for paint locker light is missing. 6) There are excessive open
Documentation › Logs/Records › Oil Record Book
Issued 12 August 2011
Resolved
1710 Oil record book 1) Crew not using correct code for C.11.1 / C.11.2 / C11.3 2) Crew has not been documenting manual transfers under C.11.4 3) Crew has been using old oil record book not the one approved by class.
Documentation › Logs/Records › Oil Record Book
Issued 12 August 2011
Resolved
1710 Capacity of bilge tank listed on IOPP certificate stated 82.51. The capacity of bilge on the capacity plan states 80.0. Capacity being used by crew in oil record book is 82.51. Class surveyor must advise.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 August 2011
Resolved
2510 Crew did not wear life jackets while working on embarkation ladder. Safety guards are missing from grinding wheels and wire brushes. Parts of the voyage plan held no regard to location and transit of vessel. SOLAS IX/5 10c
Lifesaving › Lifeboat › Propulsion Engine
Issued 12 August 2011
Resolved
0610 While lowering the port side lifeboat dust and rust particles were seen coming from the davit motor. Class must address. 17 a/b/c
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 12 August 2011
Resolved
3099 The ship identification number shall be permanently marked. Ship's identification number located in the engine room is painted above the engine control room, and is not permanent.
Engineering › Steam System (main) › Piping
Issued 20 July 2009
Resolved
AUX steam return line (to AFT well tank) STBD side Bottom Deck Engine Room leaking profusely into ships bilge. This condition causes excessive water in the bilge. 74 Solas I/11- Rectify to the Satisfaction of Class.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 20 July 2009
Resolved
Both fire suits are in non compliance- One suit due to tear in jacket, and the other due to missing reflective material on gloves. These conditions pose a risk to the crew during a fire. Solas 74 II-2 51(j)(i) Rectify to the Satisfaction of Class.
Lifesaving › Launching Appliances › Davit
Issued 20 July 2009
Resolved
Both Port & Stbd Lifeboat Davits are 4 months overdue for annual inspection. This brings into doubt the condition of the launching appliance, posing a hazard to the crew during use of appliances. Solas 2004 cons. III/20.11.2.2
Rectify to the Satisfaction of Class.
Communications › Radio Communications › Satellite Communications Capability
Issued 20 July 2009
Resolved
Both SARTS have expired batteries, which hinders the capability of them being readily accessible for proper use. 74 Solas III/6.2.2(04 cons) Rectify to the Satisfaction of Class.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2008
Resolved
Vessel's steering gear area does not have suitable handrails, grating, or other non-slip surfaces creating a hazardous condition in the event of a hydrolic fluid leak.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 January 2008
Resolved
Vessel has earth ground on 44V electrical system
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 January 2008
Resolved
Vessel must provide documentation from certificate issuing authority addressing the installation of pvc piping on seawater overboard
Engineering › Fuel Oil Service System › Valve
Issued 25 January 2008
Resolved
Vessel's emergency generator fuel supply remote fuel shut off valve does not close completely
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 9 May 2007
Resolved
Vessel does not have a approved Sailing Direction Publication for the Gulf of Mexico. Vessel is to provide proof of the appropriate publication for the next Port State Control Inspection
Lifesaving › Launching Appliances › Davit
Issued 28 September 2005
Resolved
Lifeboat davit limit control switches are inoperable.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 September 2005
Resolved
Fire doors with magnetic hold backs do not close when activated from bridge.
Personnel › Manning/Qualifications
Issued 9 June 2003
Resolved
First Engineer not in possession of a valid medical certificate. The F.E. recently a sister ship for M/V ATLANTIC EXPRESS and the certificate was not transferred. LEGACY COMPONENT DESC: Medical Fitness
Electrical › Electrical Distribution System (service)
Issued 9 June 2003
Resolved
Electrical box not permanently affixed to bulkhead on maindeck superstructure. LEGACY COMPONENT DESC: Junction Box
Electrical › Lighting (service)
Issued 9 June 2003
Resolved
Light cover missing in forward bow compartment. LEGACY COMPONENT DESC: Lighting Fixture
Accommodation/Occupational Safety › Occupational Safety
Issued 9 June 2003
Resolved
Machinery guard missing on starboard anchor windlass motor. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Accommodation/Occupational Safety › Occupational Safety
Issued 8 November 2002
Resolved
Repair the safety storm rail located stbd side fwd main deck. Storm rail is bend. LEGACY COMPONENT DESC: Deck Rail
Accommodation/Occupational Safety › Occupational Safety
Issued 8 November 2002
Resolved
The safety rail on Starboard side of the bridge platform needs to be repair. One section is missing. LEGACY COMPONENT DESC: Deck Rail
Electrical › Electrical Distribution System (service)
Issued 8 November 2002
Resolved
Remove electric wire at port aft of boat deck or install it inside of a juntion box. LEGACY COMPONENT DESC: Wiring
Accommodation/Occupational Safety › Occupational Safety
Issued 8 November 2002
Resolved
Repair bent safety rail located aft port lifeboat. LEGACY COMPONENT DESC: Deck Rail
Accommodation/Occupational Safety › Messroom
Issued 8 November 2002
Resolved
Repair damaged floor in crew mess.
Construction/Loadline › Markings
Issued 8 November 2002
Resolved
Paint the Loadline in contrasting color of ship hull, on both sides. LEGACY COMPONENT DESC: Load Line Mark
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 8 November 2002
Resolved
Privide proper documentation (Certificate of Inspectoin of Crew Accomodation) foffr maxinum crew member on board. LEGACY COMPONENT DESC: People Per Room
Lifesaving › Inflatable Liferafts
Issued 8 November 2002
Resolved
Port side liferaft has a crack on the lower shell. Repair/Replace and have classification approve. LEGACY COMPONENT DESC: Container Construction
Construction/Loadline › Structures
Issued 8 November 2002
Resolved
Replce corroded vent pipe for the Apparatus room next to the battery room.
Electrical › Electrical Distribution System (service)
Issued 8 November 2002
Resolved
Remove bare wires for the light fixture in the apparatus room next to the battery room. LEGACY COMPONENT DESC: Wiring
Fire Fighting › Structural - A Class Divisions
Issued 8 November 2002
Resolved
Performe maintenance to the port side class "A" fire door located at the emergency exit in main engine space. The door does not close completely. LEGACY COMPONENT DESC: Openings - Fire Doors
Accommodation/Occupational Safety › Messroom
Issued 8 November 2002
Resolved
Have vessel Administration to address roach infestation in galley and adjacent spaces prior to 07DEC02 and have administration to fax statement of action taken to our office. LEGACY COMPONENT DESC: Location
Navigation › Collision/Grounding Avoidance
Issued 6 November 2002
Resolved
LETTER OF DEVIATION ISSUED FOR INOPERATIVE SECOND RADAR. LEGACY COMPONENT DESC: Radar
Lifesaving
Issued 1 November 2001
Resolved
Replace expired hand flares for port & stbd lifeboats. Total 12 flares needed.
Accommodation/Occupational Safety
Issued 1 November 2001
Resolved
Repair wasted treads to ladders IWO aft house L/B deck and above.
Deck/Cargo
Issued 1 November 2001
Resolved
repair crane drive chain stbd side #1 hold chain wasted/fractured.
Lifesaving
Issued 1 November 2001
Resolved
remove all paint supplies from engine room.
Deck/Cargo
Issued 1 November 2001
Resolved
Replace all missing flame screens using 30x30 mesh, IWo all FO storage tanks, vents on main deck around house.
Construction/Loadline
Issued 1 November 2001
Resolved
Replace approved screens for ballast. Numerous vents missing bug approved screens.
Lifesaving
Issued 1 November 2001
Resolved
Replace damaged food rations for port & stbd lifeboats. 12 port, 16 stbd Total 28 @ 10000 kjs each.
Fire Fighting
Issued 1 November 2001
Resolved
Class Society surveyor to attest to the proper repair & operation of fixed CO2 system. Piping from CO2 room to cargo block being replaced. (wasted)
Engineering
Issued 1 November 2001
Resolved
Class society surveyor to attest to proper repair and operation of OWS. Both storage tanks wasted/holed at bottom.
Engineering
Issued 1 November 2001
Resolved
Class society surveyor to attest to temp repair & recommend permanent repair to SW cooling on air cooler piping main engine (intake & discharge).
Electrical
Issued 1 November 2001
Resolved
Class society surveyor to attest to proper repair to temp repair IWO discharge for generator & main engine cooling stbd side.
Electrical
Issued 1 November 2001
Resolved
Class to attest to permanent repair recommendation, temp repair IWO soft patch suction line main generator cooling stbd.
Accommodation/Occupational Safety
Issued 1 November 2001
Resolved
Repair all wasted rails throughput house and deck area. Numerous wasted/missing rails.
Construction/Loadline
Issued 2 April 2001
Resolved
Make repairs to automatic closure device to engine room access door. _x001C_ SOLAS 74 II-2/5. Make repairs prior to next U.S. port.
Navigation
Issued 24 January 2000
Resolved
VESSEL REQUESTED LOD WITH SECONDARY RADAR INOPERABLE
Navigation
Issued 18 March 1999
Resolved
The vessel's magnetic compass was not visible from the main steering stand.
Lifesaving
Issued 18 March 1999
Resolved
The lifeboats were missing all provisions and pyrotechnics. _x001C_ (SOLAS 74 REG III/41)
Navigation
Issued 18 March 1999
Resolved
The chart for the area transited (NOAA 11370) was a 1986 edition with no corrections.
Navigation
Issued 18 March 1999
Resolved
Tidal current tables for the Gulf Of Mexico was not onboard.
Deck/Cargo
Issued 18 March 1999
Resolved
The winches on the focsle were leaking hydraulic oil. (SOLAS 74 REG I/11)
Navigation
Issued 18 March 1999
Resolved
The hydraulic oil tank for the steering gear was leaking. _x001C_ (SOLAS 74 REG I/11)
Documentation
Issued 18 March 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 18 March 1999
Resolved
The hospital had a limited supply of medicines and medical supplies._x001C_ (PWSA 33USC 1223(B))
Navigation
Issued 18 March 1999
Resolved
A vessel was missing a non-slip surface on deck by the steering gear controls. (SOLAS 74 REG II/29)
Lifesaving
Issued 18 March 1999
Resolved
The paint locker was severely cluttered preventing entry to the space._x001C_ (SOLAS 74 REG II/2)
Fire Fighting
Issued 18 March 1999
Resolved
The vessel's fire fighting gear was not stowed in accordance with the fire control plan. (SOLAS 74 REG.II/20)
Lifesaving
Issued 18 March 1999
Resolved
The vessel's liferafts were not mounted properly. (SOLAS 74 REG III/38)
Fire Fighting
Issued 25 August 1998
Resolved
EMERGENCY ESCAPE DOOR,IN ENGINE ROOM, HAS BROKEN HINGE. REPAIR/RENEW PROVIDE CLASS REPORT NLT 8/31/98.
Navigation
Issued 25 August 1998
Resolved
CHARTS FOR JACKSONVILLE NOT CURRENT. PUBS OUT OF DATE. PROVIDE CURRENT CHARTS NLT 26AUG98.
Documentation
Issued 25 August 1998
Resolved
IOPP FORM "A" NOT ON BOARD. PROVIDE NLT 27AUG98.
Engineering
Issued 25 August 1998
Resolved
FIBERGLASS PATCH UPPER L/O COOLER. REPAIR/RENEW PROVIDE CLASS REPORT 25SEP98.
Navigation
Issued 25 August 1998
Resolved
OUTDATED CHARTS AND PUBS SHOULD BE ADDRESSED BY ISM. PROVIDE DOCUMENTATION THAT OUTDATED CHARTS AND PUBS ARE ADDRESSED BY ISM.
Navigation
Issued 25 August 1998
Resolved
EMERGENCY STEERING NOT DONE ACCORDING TO PROCEDURE. RUDDER RETURNS TO ZERO.PROVIDE PROOF EMERGENCY STEERING WORKS ACCORDING TO INSTRUCTION OR THAT SYSTEM AUTOMATICLY RETURNS TO AMIDSHIP.
Fire Fighting
Issued 25 August 1998
Resolved
FIRE DETECTION SHOWS FAULT. REPAIR/RENEW PROVIDE CLASS REPORT NLT 31AUG98.
Fire Fighting
Issued 25 August 1998
Resolved
FIRE PUMP PRESSURE GAUGES BROKE. REPAIR/RENEW PROVIDE CLASS REPORT NLT 25SEP98.
Deck/Cargo
Issued 18 December 1997
Resolved
RENEW AFT MOORING LINE PORT SIDE.
Construction/Loadline
Issued 18 December 1997
Resolved
PROVIDE CLASS REPORT ON REPAIRS MADE TO HOLE'S IN BOTTOM OF CARGO HOLD'S #1AND #4.
Fire Fighting
Issued 18 December 1997
Resolved
FREE UP DOGS ON HATCH DOOR FOR EMERGENCY ESCAPE FROM ENGINE ROOM.
Documentation
Issued 18 December 1997
Resolved
PROVIDE PROOF OF MASTER'S AND SECOND ENGINEER'S APPLICATION TO PANAMA FOR LICENSE RENEWAL.
Accommodation/Occupational Safety
Issued 18 December 1997
Resolved
MAKE REPAIRS TO ALL HANDRAILS AS NEEDED THROUGHOUT MAIN DECK.
Navigation
Issued 29 September 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 22 August 1997
Resolved
PRIOR TO NEXT U.S PORT, AFTER GOING FOREIGN. REPAIR RECORDER FOR ECHO DEPTH SOUNDING DEVICE.
Engineering
Issued 22 August 1997
Resolved
PRIOR TO NEXT NEXT U.S, PORT AFTER GOING FOREIGN. UPDATE OIL POLLUTION PLACKARDS THROUGH OUT THE VESSEL.
Lifesaving
Issued 22 August 1997
Resolved
PRIOR TO NEXT U.S, PORT AFTER GOING FOREIGN. REPLACE PORT LIFE BOAT PROPELLER. (ORDERED 07AUG97)
Lifesaving
Issued 30 January 1997
Resolved
UPON INSPECTION ALL LIFE RINGS WERE WASTED AND ROTTED.
Lifesaving
Issued 3 December 1996
Resolved
SEA ANCHORS FOR BOTH LIFEBOATS WERE DETERIORATED._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 3 December 1996
Resolved
FORPEAK STOREROOM HAD DEADENDED ELECTRICAL WIRING NEAR ELECTRIC PANEL._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 3 December 1996
Resolved
PORT LIFERAFT SEA PAINTER WAS MISSING THE WEAK LINK.
Deck/Cargo
Issued 3 December 1996
Resolved
#1 CARGO HATCH OPENING PUMP IS LEAKING OIL ON THE PORT SIDE._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 3 December 1996
Resolved
SOME MEDICATIONS WERE EXPIRED. MEDICAL LOCKER WAS VERY LIGHTLY STOCKED._x001C_ ASPIRIN, CALIMINE LOTION, ANTACIDS, SMALL BANDAGES._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 3 December 1996
Resolved
LOADLINE AND DRAFT MARKINGS WERE WORN DOWN AND NOT IN CONTRASTING COLOR._x001C_
Navigation
Issued 3 December 1996
Resolved
COMMUNICATION SYSTEM BETWEEN BRIDGE AND STEERING ROOM WAS INOP._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 3 December 1996
Resolved
VESSEL HAD A SPACE HEATER TEMPORARILY WIRED TO 440V DISTRIBUTION PANEL INSTEAD OF A BLOCK HEATER FOR THE EMERGENCY GENERATOR. TEMP SPLICES WERE UNSAFE. SPACE HEATER WAS BURNING THE PAINT ON THE DECK.
Navigation
Issued 3 December 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH CHART 12327 MISSING (3) CORRECTIONS, 96-13, 19, AND 24. (LATER CORRECTIONS HAD BEEN MADE)
Navigation
Issued 3 December 1996
Resolved
EXCESSIVE HYDRAULIC OIL ON DECK IN STEERING ROOM._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 3 December 1996
Resolved
LIGHT FIXTURE ON PORT BRIDGE WING WAS HANGING BY ELECTRIC WIRING AND STUFFING TUBE WAS CRACKED.
Lifesaving
Issued 3 December 1996
Resolved
LIFERAFT FOR FOCSLE WAS IMPROPERLY STOWED INSIDE THE FOREPEAK._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 3 December 1996
Resolved
INTERNATIONAL SHORE CONNECTION WAS MISSING THE GASKET.
Fire Fighting
Issued 3 December 1996
Resolved
FIXED CO2 SYSTEM INSTRUCTIONS MISSING FROM CO2 ROOM._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 3 December 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH AN INOPERATIVE SECONDARY RADAR ANDDID NOT REQUEST A LETTER OF DEVIATION.
Accommodation/Occupational Safety
Issued 3 December 1996
Resolved
INSCECTICIDES AND CLEANING SUPPLIES ON SHELVES ABOVE FOOD IN DRY STORES ROOM.
Electrical
Issued 3 December 1996
Resolved
LIGHTING FIXTURES ABOVE RACKS IN HOSPITAL WERE INOP.
Electrical
Issued 3 December 1996
Resolved
RACK LIGHT IN AB ROOM 121 BROKEN AND WIRING EXPOSED.
Deck/Cargo
Issued 30 October 1996
Resolved
PRIOR TO NEXT U.S. VOYAGE INSTALL MECHANICAL PLUGS IN ALL OIL CONTAINMENT WELLS.
Fire Fighting
Issued 30 October 1996
Resolved
PRIOR TO NEXT U.S. VOYAGE REPAIR LATCH ON FIRE STATION BOX, PORT SIDE BETWEEN HOLD #3 AND HOLD #4.
Fire Fighting
Issued 30 October 1996
Resolved
PRIOR TO NEXT U.S. VOYAGE REPAIR ALL VENT DAMPNERS. VERY HARD TO OPEN AND CLOSE, AND SOME ARE STUCK IN THE CLOSED POSITION.
Fire Fighting
Issued 30 October 1996
Resolved
DEMONSTRATE REMOTE OPERATION OF EMERGENCY FIRE PUMP. SWITCH LOCATED ON BRIDGE DOESN,T WORK PROPERLY.
Accommodation/Occupational Safety
Issued 30 October 1996
Resolved
PRIOR TO NEXT U.S. VOYAGE RENEW LADDER RUNGS LEADING TO DECK ABOVE BRIDGE.
Documentation
Issued 30 October 1996
Resolved
PRIOR TO DEPARTURE PROVIDE SOLAS SAFETY CONSTRUCTION AND FORM (E) OF SOLAS SAFETY EQUIPMENT CERTIFICATES.
Navigation
Issued 30 October 1996
Resolved
PRIOR TO DEPARTURE REPAIR ECHO DEPTH SOUNDER RECORDER. PAPER SLIPPING AND NOT RECORDING PROPERLY.
Lifesaving
Issued 30 October 1996
Resolved
PRIOR TO DEPARTURE REPLACE RINGBUOYS ON PORT AND STARBOARD SIDES OF_x001C_ LIFEBOAT DECK.
Electrical
Issued 30 October 1996
Resolved
PRIOR TO NEXT U.S. VOYAGE INSTALL COVER ON ELECTRICAL JUNCTION BOX IN FORWARD BOS'N HOLD.
Navigation
Issued 15 April 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH THE LIGHT LIST NOT CORRECTED UP TODATE.
Navigation
Issued 15 April 1996
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH A COAST PILOT NOT CORRECTED UP TO DATE.
Fire Fighting
Issued 12 April 1996
Resolved
4 FIRE STATION VALVE WHEELS/HANDLES MISSING FROM 4 DIFFERENT HOSE_x001C_ STATIONS. SOLAS 74 II-2/21_x001C_
Lifesaving
Issued 12 April 1996
Resolved
PROPERLY STOW ALL OXYGEN & ACETYLENE CYLINDERS PRIOR TO DEPARTURE.
Engineering
Issued 12 April 1996
Resolved
REMOVE WASTED COVER FOR FLAME SCREENS FOR L/O & SLUDGE TANK VENTS _x001C_ LOCATED MAINDECK STBD SIDE.
Navigation
Issued 12 April 1996
Resolved
REPAIR COMMS BETWEEN BRIDGE & STEERING ROOM.
Lifesaving
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPLACE WIRE GRIPS(TIE DOWN STRAPS) ON BOTH LIFEBOATS.
Engineering
Issued 16 January 1996
Resolved
PRIOR TO BUNKERING IN THE U.S., CONDUCT HYDROSTATIC TEST OF BUNKER PIPING TO 150% MAWP.
Fire Fighting
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPAIR FIRE HOSE STORAGE BOXES ON MAIN DECK FIRE STATIONS.
Engineering
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPLACE FLAME SCREENS ON F/O AND L/O VENTS.
Construction/Loadline
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPAIR HYDRAULIC LEAK IN CARGO HATCH LINEFOR #6 CARGO HATCH.
Lifesaving
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPLACE 32 EXPIRED BATTERIES FOR LIFEJACKET LIGHTS.
Construction/Loadline
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, PROVIDE CLASS SOCIETY REPORT FOR DECK HYDRAULIC LINE TEST.
Fire Fighting
Issued 16 January 1996
Resolved
REPAIR/REPLACE HANDLE TO VALVE ON FIRE STATION, STBD MAIN DECK, NEXT TO SUPERSTRUCTURE.
Lifesaving
Issued 16 January 1996
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, REPLACE GRABLINES ON BOTH LIFEBOATS.
Navigation
Issued 6 February 1992
Resolved
VESSEL'S MANEUVERING FACT SHEET WAS MISSING MANEUVERING INFO RELAVENT TO VESSEL'S LOADED CONDITION. THIS INFO HAD BEEN MISSED BY THE COAST GUARD ONALL PREVIOUS BOARDINGS.
Navigation
Issued 22 October 1985
Resolved
TESTS REQUIRED BY 33CFR164.25 WERE NOT RECORDED IN SHIP'S LOG
Navigation
Issued 22 October 1985
Resolved
TIDE TABLE, TIDAL CURRENT TABLES, AND INLAND NAVIGATION RULES PUBLICATIONS WERE NOT ONBOARD.
Navigation
Issued 22 October 1985
Resolved
MANEUVERING INFROMATION NOT POSTED IN WHEEL HOUSE 33CFR164.35(G)
Documentation
Issued 22 October 1985
Resolved
INFORMATION REQUIRED IN OIL TRANSFER PROCEDURES WAS MISSING 33CFR155.730
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.