MAURY USCG vessel records Sign in
← All vessels

TAMMY JANE

TAMMY JANE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1989, most recently in February 2026, along with 99 deficiencies and 4 casualty investigations between 2016 and 2025.

Records from 1989 to 2026. Most recent: inspection, 9 February 2026.

Built
1985
Last inspected
9 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9309
261853
Flag
UNITED STATES
367747360
Maury page id
psix-261853

Inspections, by type

…with no type recorded9
Years with a record 34 calendar years (1989–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 14.0 ft × 8.4 ft
Registered tonnagegross 32 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLENN YOUNG BOATS · OCEAN SPRINGS, MS, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHILTON HEAD ISLAND, SC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Simplified, Net Ton
32 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9309MMSI 367747360 · active · compulsorily equipped · granted 28 April 2026, expires 20 July 2036
WBR3579MMSI 367342140 · cancelled · compulsorily equipped · granted 11 March 2008, cancelled 13 June 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

9 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8308353
22 April 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8117187
22 March 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8099536
22 March 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8101482
3 June 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7926426
14 February 2024 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7865147
6 July 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7735070
15 March 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7407438
27 January 2022 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7386705
17 March 2021 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7157697
16 March 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7157793
3 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7149644
13 November 2020 Type not recorded
No type recorded · Station Tybee · USCG Southeast District (CGD-SE) · Activity 7095035
19 May 2020 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6966239
6 January 2020 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6883646
4 March 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6636161
1 May 2018 Hull Examination · Drydock Exam · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6405514
23 February 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6360452
15 June 2017 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6181457
17 May 2017 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6149581
24 April 2017 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6125953
22 February 2017 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6092431
13 September 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5998949
17 August 2016 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5981673
16 August 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5975132
25 July 2016 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5952630
14 July 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6065970
21 March 2016 Hull Examination · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5838400
10 September 2015 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5717790
27 August 2014 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4973675
14 May 2014 Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4858625
17 May 2012 DAPI Audit · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4318792
3 October 2008 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3337742
24 March 2008 Administrative Inspection · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3164753
11 October 2007 Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3080245
9 October 2007 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3075747
3 October 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2792380
5 August 2005 Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2452477
8 July 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2519276
26 July 2004 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2145276
3 October 2003 Re-Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1918935
17 September 2002 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1676478
10 October 2001 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1403474
30 July 2001 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1405242
10 July 2000 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1439063
5 October 1999 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1459551
2 September 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 690795
10 August 1998 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1464121
30 June 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 69750
11 August 1997 Hull Examination · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1435972
11 June 1996 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1407701
30 June 1995 Examination of Repairs · Inclining Experiment · Hull Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1385483
26 April 1994 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1436863
6 April 1993 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1412493
10 April 1992 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1269067
22 October 1991 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 934136
12 April 1991 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1211041
28 June 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 911308
14 June 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1237008
2 May 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212516
4 April 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212515
4 August 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1037586
18 April 1989 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347410

Deficiency record · 99

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 June 2024 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. [name withheld] JR, one of two masters, is restricted from operating vessel until valid medical certificate issued. 46 CFR 15.401(c)
Action required: 705 - Other - as specified
Resolved 12 June 2024
Resolution: Operator provided documentation reflecting a valid medical certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2024 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Vessel's fuel shutoff stations not labeled. 46 CFR 185.30-20 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 24 June 2024
Resolution: Photos received of new fuel shutoff placards.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 June 2024 Resolved
Drip pans fitted with flame screens may be required under fuel strainers other than those mounted on the engine. MI requested drip pans be installed beneath fuel strainers. 46 CFR 182.20-40(b)(5) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 26 June 2024
Resolution: Pictures received of new flame bowls installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 June 2024 Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Vsl's starboard side battery housing not secure. 46 CFR 183.05-20(b) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 26 June 2024
Resolution: Picture received of battery housing secured.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 June 2024 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member at least once every three months as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Vsl logbook missing log of previous drills conducted, logged drills conducted for COI inspection. 46 CFR 185.420
Action required: 10 - Deficiency Rectified
Resolved 11 June 2024
Resolution: Operator logged drills conducted on 6/11/24.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. EPIRB hydrostatic release expired. 46 CFR 180.175(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 24 June 2024
Resolution: Photos received of new hydrostatic release installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 June 2024 Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vsl missed annual inspection required by 01 May 2024. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2024
Resolution: Renewal COI inspection conducted 6/11/24
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 July 2023 Resolved
Vessels required to carry radio equipment must be inspected by a certified FCC Inspector once every 5 years. Vessel's Safety Radio Certificate is expired.
Action required: 10 - Deficiency Rectified
Due 6 July 2023
Resolved 11 July 2023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 January 2022 Resolved
At each initial and subsequent inspection of certification and shall conduct the following inspection of hull structure and appurtenances: Inspect the condition of the construction of the hull. Extreme rot and termite infestation was found in the hull structures strength members in the vessels stern compartment deck longitudinal's. Vessel must provide a repair proposal to include a damage assessment for these strength members.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2022 Resolved
Annual maintenance and recharging of extinguishers must be done annually. Vessels fire extinguishers have not been services or inspected under NFPA 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 January 2022 Resolved
A vessel not required a power driven fire pump must have at least 03 two and a half gallon buckets (2.5 gal) with an attached lanyard. Vessel was missing a lanyard on one of their fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 January 2022 Resolved
All machinery and equipment must be installed and maintained to afford adequate protection from fire, explosion, failure, and injury. MSD pump was not mounted and laid on top of MSD tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 January 2022 Resolved
A vessel must carry adequate up to date and applicable charts and nautical publications. Vessel missing up to date tide tables and Coast Pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 5 Lifejackets were deteriorated and need replacing. Vessel restricted to 34 adults.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 April 2021
Resolution: Replaced the unservicable life jackets
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 March 2021 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Vessel's EPIRB battery is expired. Vessel restricted to 3 nm from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 April 2021
Resolution: Vessel replaced and updated registration of the epirb
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 March 2021 Resolved
Each EPIRB must be tested monthly and shall be logged or otherwise documented. Vessel can not provide proof of monthly test.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2021
Resolution: New epirb placed in service and monthly testing being logged
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2021 Resolved
At each inspection all observed unsafe practices and hazardous situations must be corrected. Vessel has a crack on the port side raw water pipe going to the exhaust in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 26 April 2021
Resolution: vessel welded crack in exhaust elbow
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2021 Resolved
At each inspection all observed unsafe practices and hazardous situations must be corrected. Vessel has 2 exhaust leaks in the port lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 15 June 2021
Resolution: Vessel replace leaking hose and clamps
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2021 Resolved
Each navigation light and equipment must be fit for the service intended. Vessel's bell is missing the lanyard and inoperable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 26 April 2021
Resolution: vessel corrected operation of the bell
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's float light does not work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 26 April 2021
Resolution: vessel replaced the float light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2021 Resolved
Piping used in a vital system must be composed of ferrous materials or meet 182.720. Vessel has flexible hose on bilge suction.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 1 May 2021
Resolution: vessel replaced hose with SAE compliant hose and fittings
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2021 Resolved
A vessel of 12 meters or more in length must have a sternlight visibility of 2 miles. Vessel restricted to daytime operations due to extinguished stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 April 2021
Resolution: vessel replaced the stern light
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2021 Resolved
Electrical equipment used on a vessel must be installed and maintained to protect crew and passengers from electrical hazards, including fire, caused by or originating in electrical equipment. Vessel is using a power strip on bridge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 26 April 2021
Resolution: Vessel removed the power strip
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 February 2020 Resolved
Exhaust gas must not leak from the piping or any connections. Repair both exhaust leaks in aft compartment.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 7 March 2020
Resolution: Repaired exhaust leak
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 February 2020 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements. Master is missing radio operator permit. 47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Master has Marine Radio Operator Permit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2020 Resolved
Each life jacket must be marked with Type I retro reflective material approve in 46 CFR 164.018 or other standard specified by the Commandant. Life jackets need additional retro reflective tape.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Added retroreflective tape to lifejackets
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 February 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts nautical publications. Need up-to-date navigation rules on-board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 9 March 2020
Resolution: Up-to-date nav rules onboard
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 April 2017 Resolved
Install engine shutdown switch on Pre-engineered fixed gas fire extinguisher system to operate upon activation of fixed gas system to stop engine and then allow operator to restart MDE in override mode or install ventilation to allow engine to take air form outside of the engine space. Both methods to be approved by MI prior to installation.
Due 16 June 2017
Resolved 15 June 2017
Lifesaving › Lifefloat › Not on Board
Issued 24 April 2017 Resolved
Install approved life float of proper capacity on board & make available to MI for inspection. Vessel route reduced from LC to LBS until corrected.
Action required: 705 - Other - as specified
Resolved 11 May 2018
Resolution: Route changed to LBS.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 April 2017 Resolved
Conduct MOB while trawling for MI onboard.
Due 24 May 2017
Resolved 15 June 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 April 2017 Resolved
Remark life ring.
Due 24 May 2017
Resolved 17 May 2017
Lifesaving › Lifebuoys › Approval
Issued 24 April 2017 Resolved
Replace reflective tape on life ring.
Due 24 May 2017
Resolved 17 May 2017
Lifesaving › Lifebuoys › Serviceable
Issued 24 April 2017 Resolved
Replace worn grab lines on life ring with proper line.
Due 24 May 2017
Resolved 17 May 2017
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 April 2017 Resolved
Repair inoperable radar or remove from vessel.
Due 16 June 2017
Resolved 15 June 2017
Resolution: Removed from vessel.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 4 October 2016 Resolved
Develop a training/operating plan for trawling operation including man overboard recovery procedures.
Due 30 November 2016
Resolved 22 February 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 October 2016 Resolved
IAW 46 CFR 183.340, place proper connections inside approved junction box on port aft davit.
Due 30 November 2016
Resolved 22 February 2017
Unknown
Issued 17 September 2016 Resolved
Provide OCMI with electrical plans for inches with its electrical & operating information.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016
Resolution: Removed from vessel
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 September 2016 Resolved
Remove lug nut connections/splices on winch controls & replace with approved connections IAW 46 CFR 183.340. Place in approved junction box.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016
Resolution: Removed from vessel.
Electrical › Electric Supply System (service) › Cable
Issued 17 September 2016 Resolved
Provide OCMI with size/type of wiring/cabling for winches IAW 46 CFR 183.340.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016
Resolution: Removed from vessel.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 17 September 2016 Resolved
Provide OCMI with acceptable method of overcurrent protection to winch electrical installation IAW 46 CFR 183.380.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016
Resolution: Removed from vessel.
Unknown
Issued 17 September 2016 Resolved
Provide OCMI with electrical one line drawing showing all electrical components of winch installation on port/starboard sides.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016
Resolution: Removed from vessel.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 September 2016 Resolved
Provide OCMI with diagram showing all structure & equipment modifications to vessel since purchasing vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2016
Lifesaving › Lifefloat › Serviceable
Issued 13 September 2016 Resolved
Remove wasted lifefloat from service. Route is reduced from LC to LBS until lifefloat is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 May 2017
Communications › Radio Communications › EPIRB
Issued 13 September 2016 Resolved
Place EPIRB decal on unit.
Due 13 October 2016
Resolved 4 October 2016
Engineering › Bilge Water Management System › Strainer
Issued 13 September 2016 Resolved
Place bilge strainers on all bilge suctions.
Due 13 October 2016
Resolved 4 October 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 September 2015 Resolved
Renew expired COD.
Condition: Invalid
Due 1 October 2015
Resolved 2 October 2015
Resolution: Vessel owner provided current COD.
Communications › Radio Communications › EPIRB
Issued 4 September 2014 Resolved
46 CFR 184.502 requires EPIRBs to be maintained IAW 47 CFR 80. Registration and owner contact number was not correct. Provide proof of updated number.
Due 4 October 2014
Resolved 19 September 2014
Resolution: Provided EPRIB registration form with the correct contact number.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 4 September 2014 Resolved
46 CFR 185.604(h) requires all life jackets to be marked with Type I retro reflective tape. The tape provided is deteriorated and is not in serviceable condition on 18 of the 39 required adult life jackets. Limit vessel to the carriage of 29 adult passengers until Owner/Operator provides proof of appropriate markings.
Due 4 October 2014
Resolved 25 September 2014
Resolution: O/O provided the correct retro reflective tape on the remaining 10 life jackets.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 4 September 2014 Resolved
Provide proof that all crew members are enrolled in a random drug testing program. Cite: 46 CFR 16
Due 4 October 2014
Resolved 25 September 2014
Resolution: O/O provided documentation that all employees are enrolled in a random drug testing program.
Engineering › Bilge Water Management System › Pump
Issued 4 September 2014 Resolved
46 CFR 182.530(c) requires a visual indicator at the operating station for the automatic bilge pump operating station for the automatic bilge pump. the visual indicator is not working. Provide proof of proper operation..
Due 4 October 2014
Resolved 8 September 2014
Resolution: The indicator required by 46 CFR 182.530(c) was restored and properly operating.
Engineering › Fuel Oil Service System › Piping
Issued 4 September 2014 Resolved
Replace and provide proper support for main engine fuel vent hose required by 46 CFR 182.720.
Due 4 October 2014
Resolved 8 September 2014
Resolution: The supports for the main engine fuel vent as required by 46 CFR 182.720 were replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 September 2014 Resolved
46 CFR 176.25-50(a) requires overall safe practices onboard vessel. Provide proper support for raw water cooler hoses on the hydraulic system on the transmission.
Due 4 September 2014
Resolved 25 September 2014
Resolution: O/O provide sufficent bracing for the hydraulic lines.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 August 2014 Resolved
46 CFR 177.35-15 (a) requires guards around moving parts of machinery. Provide guards around alternator on starboard main.
Due 4 October 2014
Resolved 8 September 2014
Resolution: The guards required by 46 CFR 177.35-15 were properly placed and secured around all moving parts.
Engineering › Steering Gear System › Rudder
Issued 15 May 2014 Resolved
Provide repair proposal to renew/repair the following: (a) Crevice corrosion on the stainless steel forward and aft (port and starboard) shaft struts (and associated fasteners); and (b) Crevice corrosion on the port and starboard rudder blades and rudder shaft/stock (and associated fasteners).
Due 15 June 2014
Resolved 10 June 2014
Resolution: Completed in-kind installation of the shaft struts and rudders completed.
Construction/Loadline › Hull › Bottom Plating
Issued 15 May 2014 Resolved
Properly repair starboard FRP shaft tube. 46CFR176.25-5
Due 15 June 2014
Resolved 10 June 2014
Resolution: Starboard propeller shaft tube FRP properly repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 May 2014 Resolved
Properly repair port amidships handrail cracked weld. 46CFR177.35-1
Due 15 June 2014
Resolved 12 June 2014
Resolution: Port amidships handrail (top course) properly re-welded.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 May 2014 Resolved
Properly display name and home port of vessel on transom. 46CFR185.30-1
Due 15 June 2014
Resolved 10 June 2014
Resolution: Name on transom properly displayed.
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2014 Resolved
Properly repair weak floor board outside head. 46CFR176.15-5
Due 15 June 2014
Resolved 10 June 2014
Resolution: floor board at landing to head properly renewed.
Construction/Loadline › Hull › Side Shell
Issued 17 May 2012 Resolved
A total of twelve gelcoat blisters were found during the inspection. Repair blisters to the satisfaction of the attending Marine Inspector prior to receiving credit for hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2012
Resolution: Vessel owner repaired the affected areas utilizing the West System method for blister repair.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 October 2007 Resolved
Submit repair proposal to make permanent repairs to 1) Vsl's portside rail bulkhead aprox amidships. 2) FWD bow soft deck 3) Aft lazerette deck beams have wood rot.
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 9 November 2007
Resolution: Vessel''s owner submitted proposal to satisfaction of Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 9 October 2007 Resolved
Ensure all crew members are added to company's drug and alcohol testing program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 12 October 2007
Stability › Weathertight Integrity › General
Issued 9 October 2007 Resolved
Properly repair two cracked cabin windows.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 24 March 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 August 2005 Resolved
Rewrap exhaust with wire & remove duct tape from exhaust.
Condition: Improper/Lack of Maintenance
Due 10 August 2005
Resolved 10 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 August 2005 Resolved
Replace exhaust mounts with non-combustible hangers.
Due 10 August 2005
Resolved 10 August 2005
Stability › Watertight Integrity › General
Issued 5 August 2005 Resolved
Tioghten stuffing box to stop leak in aft steering.
Condition: Unknown
Due 10 August 2005
Resolved 10 August 2005
Engineering › Lubricating Oil Service System › Piping
Issued 8 July 2005 Resolved
Clean oil off stbd engine and repair leaks. Provide report detailing repair.
Condition: Improper/Lack of Maintenance
Due 29 July 2005
Resolved 10 August 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 July 2005 Resolved
Replace port remote fuel shutoff
Condition: Improper/Lack of Maintenance
Due 29 July 2005
Resolved 10 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 July 2005 Resolved
Replace port engine guard
Condition: Improper/Lack of Maintenance
Due 29 July 2005
Resolved 10 August 2005
Lifesaving › Lifebuoys › Stowage
Issued 8 July 2005 Resolved
Mount and mark new lifering.
Due 29 July 2005
Resolved 10 August 2005
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 July 2005 Resolved
Replace gasket on aft steering deckhatch
Condition: Improper/Lack of Maintenance
Due 29 July 2005
Resolved 10 August 2005
Lifesaving › Lifefloat › Serviceable
Issued 8 July 2005 Resolved
Repair/patch holes in lifefloat.
Condition: Improper/Lack of Maintenance
Due 29 July 2005
Resolved 10 August 2005
Construction/Loadline
Issued 10 July 2000 Resolved
PROVIDE INDICATOR LIGHTS FOR SPACES CONTAINING BILGE HIGH LEVEL ALARMS.
Condition: Unknown
Due 10 August 2000
Resolved 11 August 2000
Lifesaving
Issued 10 July 2000 Resolved
DEVELOP A VOYAGE PLAN AND PASSENGER COUNT SYSTEM.
Condition: Unknown
Due 10 August 2000
Resolved 11 August 2000
Lifesaving
Issued 10 August 1998 Resolved
APPLY RETRO-REFLECTIVE TAPE TO THREE (3) ADULT AND FIVE (5) CHILD LIFE JACKETS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Documentation
Issued 10 August 1998 Resolved
VESSEL OPERATED WITHOUT A VALID COI FROM 30JUN98 (DATE OF EXPIRATION) TO 10AUG98 (DATE OF INSPECTION. ISSUED TEMP COI. MIDF INITIATED TO CREATE A DETECTION CASE FOR MARINE VIOLATION.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Lifesaving
Issued 10 August 1998 Resolved
PROVE LIFE FLOAT WEAK LINK MEETS MANUFACTUERERS STANDARD, OR RENEW SAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Lifesaving
Issued 10 August 1998 Resolved
RENEW ONE (1) ADULT LIFE JACKET. UNTIL RENEWED, TOTAL PERSONS ALLOWED IS 43._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Lifesaving
Issued 30 June 1995 Resolved
Label all life jacket lockers, mount placards and life jacket instructions.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Fire Fighting
Issued 30 June 1995 Resolved
Service or replace fixed Halon sytem for engine room.
Condition: Unknown
Due 30 June 1995
Resolved 30 June 1995
Engineering
Issued 12 April 1991 Resolved
Provide rotating machinery guards on both main engines_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Navigation
Issued 12 April 1991 Resolved
Provide 24 inch anchor ball_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Fire Fighting
Issued 12 April 1991 Resolved
Provide suitable length of suction and discharge hose for hand fire pump_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Navigation
Issued 12 April 1991 Resolved
Provide compass deviation card_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Lifesaving
Issued 12 April 1991 Resolved
Stencil name of vessel on paddles in life floats_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Engineering
Issued 28 June 1990 Resolved
ENSURE PROPER OPERATION OF STARBOARD EMERGENCY FUEL SHUT OFF IAW 46CFR182.20-40(B)(3)
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Lifesaving
Issued 28 June 1990 Resolved
PROVIDE EMERGENCY PLACARD FOR LOCATION OF PFD'S IAW 46CFR185.25(D)
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Documentation
Issued 28 June 1990 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Lifesaving
Issued 28 June 1990 Resolved
REMOUNT EPIRB TO ALLOW FOR FLOAT FREE OPERATION IAW 46CFR180.40(A)(3)
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Navigation
Issued 28 June 1990 Resolved
PROVIDE CURRENT CHARTS OF THE AREA TO BE NAVIGATED, COAST PILOT, LIGHT LISTTIDE TABLES AND CURRENT TABLES IAW 46CFR185.20-35.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Lifesaving
Issued 2 May 1990 Resolved
INSTALL THE PROPER SIZE WEAK LINK ON LIFE FLOATS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 2 May 1990 Resolved
OBTAIN AND POST AN FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 2 May 1990 Resolved
INSTALL A BLANK IN THE WHELLHOUSE ELECTRICAL PANEL.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 2 May 1990 Resolved
INSTALL A VALVE IN THE COLLISION BULKHEAD DRAIN LINE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
STENCIL NUMBER OF ADULT LIFE PRESERVERS ON STORAGE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 18 April 1989 Resolved
HOOK-UP VOLT AND AMP METER TO SHIP'S GENERATOR.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Documentation
Issued 18 April 1989 Resolved
OBTAIN FCC STATION LICENSE.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Documentation
Issued 18 April 1989 Resolved
OBTAIN CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Construction/Loadline
Issued 18 April 1989 Resolved
SUBMIT FIBERGLASS LAMINATE TEST RESULTS.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Lifesaving
Issued 18 April 1989 Resolved
PROVIDE LIFEJACKET LIGHTS FOR 4 ADULT AND 3 CHILDREN.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989

Casualty record · 4

14 July 2016Routine · role: Involved in a Marine Casualty · activity 6065970
16 August 2016Routine · role: Involved in a Marine Casualty · activity 5975132
16 March 2021Routine · role: Involved in a Marine Casualty · activity 7157793
22 March 2025Routine · role: Involved in a Marine Casualty · activity 8099536
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.