MAVERICK

MAVERICK is a 1986 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1986, most recently in April 2026, along with 104 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2014 and 2018.

Records from 1986 to 2026. Most recent: inspection, 24 April 2026.

Built
1986
Last inspected
24 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP7631
262046
Flag
UNITED STATES
368383460
Maury page id
psix-262046

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 39 calendar years (1986–2026)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.5 ft × 35.0 ft × 7.2 ft
Registered tonnagegross 94 / net 80
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 September 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Net Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP7631MMSI 368383460 · active · compulsorily equipped · granted 15 August 2024, expires 15 August 2034
WDH9761MMSI 367671340 · expired · compulsorily equipped · granted 9 May 2015, cancelled 14 June 2025
WSC9172MMSI 367015440 · expired · compulsorily equipped · granted 2 February 2005, cancelled 13 June 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 74

24 April 2026 Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8355389
14 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8200174
6 May 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8131070
16 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8070264
23 September 2024 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8047899
3 September 2024 In-Service Inspection · Administrative Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7995083
25 July 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7958694
19 December 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7830581
29 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7594005
5 August 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7518652
16 December 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7361962
17 September 2020 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7054258
29 June 2020 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6983614
16 December 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6862894
17 December 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6592121
25 November 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6589125
25 June 2018 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6448141
29 January 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6341486
7 December 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6322590
20 October 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6020088
9 March 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830033
1 September 2015 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5225084
6 May 2014 Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4851646
27 July 2011 MARPOL Annex VI Survey · DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4095784
26 November 2010 MARPOL Annex VI Survey · DAPI Audit · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3863573
19 February 2010 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3682469
6 July 2009 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3526566
16 December 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3357840
6 December 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3110760
27 November 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3088948
25 January 2006 Deadweight Survey · Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2559677
11 April 2005 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2307188
10 June 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2094622
27 May 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2079197
26 September 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1912212
29 July 2002 Re-Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1650644
12 February 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1486095
15 February 2001 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1410484
6 September 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1424992
15 February 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1401182
19 February 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1461969
5 August 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 797451
20 February 1998 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 778840
28 January 1998 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1116098
27 January 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 142964
27 January 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 781995
29 July 1997 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 784125
8 April 1997 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1098940
18 February 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1105976
6 August 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1087155
22 February 1996 Deficiency Check · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 882124
22 March 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1398215
22 February 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1161637
19 December 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1140238
18 February 1994 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1431338
1 February 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1429719
7 August 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 950932
24 February 1992 Drydock Extension · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 948958
24 February 1992 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 948960
25 February 1991 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 918936
25 September 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1216611
27 February 1990 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1216421
27 March 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1348495
6 March 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 887501
11 May 1988 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347986
9 March 1988 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1336751
24 March 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1329319
19 February 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1316091
10 August 1986 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1000696
7 August 1986 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1304600
7 August 1986 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1307229
9 July 1986 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1306620
19 March 1986 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 998073
4 March 1986 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 989532

Deficiency record · 104

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2025 Resolved
Firehose bracket holders are wasted, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 15 August 2025
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 August 2025 Resolved
Ships whistle not in compliance with minimum dB level, must be repaired or replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 17 October 2025
Resolution: horn replaced.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 14 August 2025 No resolution recorded
Vessel has several cracked windows. Make safe until replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025 — due date passed with no resolution recorded
Resolution: Windows are custom design, have been measured & ordered, def extended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2025 Resolved
Engineroom air receiver pressure relief valve leaks, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 17 October 2025
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025 Resolved
Engineroom dead-end wiring must be removed or properly terminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 21 January 2025
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025 Resolved
Main batteries must be chocked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 21 January 2025
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 January 2025 Resolved
Freeboard measuring tool must aboard the vessel and available to the crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 25 March 2025
Resolution: approved tool has been fabricated, installed on vessel and is readily available for the crew.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 January 2025 Resolved
emergency fuel shut-off must be properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 16 January 2025
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 January 2025 Resolved
MDE exhaust lagging requires tightening &/or replacing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 21 January 2025
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 September 2024 Resolved
Pin hole leak discovered in fuel tank void aft most bays on stbd side of keel. Vessel is not authorized to operate commercially until repairs have been completed to the satisfaction of the cognizant OCMI/attending Marine Inspector. A one-time transit will be allowed pending approval of submitted emergency drydocking and transit plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2024
Resolved 10 December 2024
Resolution: repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2022 Resolved
All ferry vessels less than 65ft must be provided with one fixed power bilge pump with a capacity of 25 gallons per minute and one portable hand pump with a minimum capacity of 5 gallons per minute. No portable hand pump onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2022
Resolution: Obtained a portable hand pump which is now onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 November 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water. The indicator light for the engine room and lazarette do not work. The panel is also mislabeled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2022
Resolution: Witnessed video of all 3 high water alarm lights working properly. The panel has also been relabeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2022 Resolved
An adult life jacket must be provided for each person carried onboard a vessel. 151 adult lifejackets are required but only 148 adult lifejackets are onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2022
Resolution: Obtained 3 new lifejackets which are properly marked and are onboard the vessel.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 29 November 2022 Resolved
Each vessel less than 65ft must be equipped with a public address system which can be a fixed PA system or a battery powered bullhorn if audible in all accommodation spaces and batteries are continually maintained at a fully charged level. PA system onboard does not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 13 December 2022
Resolution: PA system has been repaired and is audible in the passenger cabins.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 November 2022 Resolved
Each vessel must carry an approved first aid kit or a kit with equivalent contents and instructions. Medicine in first aid kit is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 13 December 2022
Resolution: New aspirin has been placed in first aid kit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 November 2022 Resolved
A marine employer whose vessel is involved in a casualty shall ensure drug and alcohol testing can be completed within the required timeframe. Alcohol testing must be conducted within 2 hours. No alcohol swabs are onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 13 December 2022
Resolution: Obtained new alcohol test strips and placed them onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 December 2021 Resolved
All machinery shall be maintained in a manner to protect against fire. Lube and gear oil gage lines for the main engine are chaffing and present a fire hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2021
Resolution: Replaced worn lines, remounted and added chafe protection to new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 December 2021 Resolved
A vessel on a lakes, bays and sounds route must carry three red hand flare distress signals and three orange smoke signals. Vessel does not have flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2021
Resolution: Obtained flares and placed them on the vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 December 2021 Resolved
A visual alarm must be provided at the operating station to indicate a high water level. Panel is not marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2021
Resolution: Marked the high water alarm panel with names of spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 December 2021 Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Vessel has an extension cord mounted in each passenger cabin space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2021
Resolved 29 December 2021
Resolution: The extension cord in each passenger space has been removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 December 2021 Resolved
Vessels carrying vehicles must have suitable barriers installed at the ends of vehicle runways. Vessel cargo nets are not tight and need a 3rd line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2021
Resolved 27 December 2021
Resolution: Added a third line and tightened the nets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2021 Resolved
Each vessel shall be provided with safe and readily available fire fighting equipment to extinguish any fires likely to be encountered. Vessel cannot secure ventilation to the engine room space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 2 February 2022
Resolution: Vent covers have been fabricated for the engine room ventilation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2020 Resolved
For each 21,000 gal or part thereof of any flammable or combustible liquid being transported on board there must be provided at least one B-V (100 pound) dry chemical fire extinguisher. Vessel does not have a B-V fire extinguisher. Vessel restricted from carrying flammable or combustible liquids.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 7 October 2020
Resolution: 125 LB ABC Dry Chemical Extinguisher procured. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2020 Resolved
All vessels of 26' and over shall be provided with individual bilge lines. Bilge piping for #3 void and laz appears to be partially clogged. Make repairs and retest to satisfaction of attending MI. 46 CFR 182.25-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2020
Resolution: Piping and strainers unclogged. System tested. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 September 2020 Resolved
All vessels must be equipped with NAV lights that are compliance with NAV RULES. STBD NAV light is inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2020
Resolution: STBD Nav light operational. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2020 Resolved
Each child life jacket must be stowed in a location that is marked and separated from adult life jackets. Child life jackets on port side not separated and stowage not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 1 October 2020
Resolution: Life jackets separated and marked. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 September 2020 Resolved
Vessel shall be equipped with suitable portable battery lights. Only one rechargeable flash light on board and battery was dead. Recharge light and procure additional light for pilot house. 46 CFR 180.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: Two flash lights provided. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2020 Resolved
All wiring and cables shall be suitable for marine service and for particular installation used. Port NAV light cable insulation deteriorated. Replace cable. Port fwd flood light cable damage. Replace cable. 46 CFR 183.10-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: New wire installed on port Nav light and port flood light. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 September 2020 Resolved
Each hatch exposed to the weather must have a securing device and be attached by hinge, captive chains, or other device to prevent loss. Three hatches on deck are not secured. Install securing device.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 October 2020
Resolved 29 September 2020
Resolution: Captive chains installed. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 September 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit missing content.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: New first-aid kit procured. All sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 16 December 2019 Resolved
A visual and audible alarm must be provided a the operating station. Compartment #3 visual indicator is inoperable. Repair/replace. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 6 January 2020
Resolution: Indicator repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2019 Resolved
One length of fire hose shall be provided for each fire hydrant. Port side hose is unserviceable. Replace. 46 CFR 181.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: New fire hose was purchased.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 December 2019 Resolved
Where at least monthly manual inspections are conducted, the date the manual inspection was performed and the initials of the person performing the inspection shall be recorded. Monthly checks not being recorded. Record monthly checks. NFPA 10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 17 December 2019
Resolution: Maintenance completed and portable extinguishers added to monthly preventative maintenance checklist.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 December 2019 Resolved
The bilge pipe piercing the collision bulkhead must be fitted with screw-down valve and must be operable from above the weather deck. Tool missing to operate valve. Replace tool. 46 CFR 182.25-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: New tool provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 December 2019 Resolved
As appropriate for intended route, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot and Light List. Extracts from publications may be provided instead of complete publication. Vessel has out-of-date charts and missing Coast Pilot and Light List. Provide publications. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: Publications provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 December 2019 Resolved
Each hatch exposed to the weather must have a securing device. Hatches on deck missing securing device. 46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: Securing device installed on each hatch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 December 2019 Resolved
The master or person in charge shall ensure that the ship is not operate unless a garbage management plan is on the ship. No management plan on board. Provide plan. 33 CFR 151.57
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 17 December 2019
Resolution: Garbage management plan provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2019 Resolved
All electrical equipment exposed to the weather must be watertight. Junction box fwd of generator has lose connections. Flood light on port side fwd of wheel house has exposed wires. Wires for port side light has exposed wires and connections do not terminate in junction box. Wires in engine room not properly secured for stbd nav light and for heater located on port side passenger area. Wires engine room for stbd nav lights do not terminate in junction box. Repair all listed items. 46 CFR 183
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: All electrical defs were resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018 Resolved
Bilge Pump check valves for forepeak, void space 1, void space 2, and laz were found installed incorrectly (backwards). Prove proper operation of the bilge pump prior to movement. Operator fixed on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Operator fixed on the spot. Operator removed bilge manifold and installed check valves correctly. Proved proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018 Resolved
Bilge pickup in laz was found missing. Replace bilge pickup prior to movement.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Bilge pickup in laz was found missing. Operator installed a bilge pickup.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018 Resolved
Strainer basket for bilge pickup in laz was found missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 22 December 2018
Resolution: Strainer basked for bilge pickup in laz was properly installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018 Resolved
High level bilge float switch was found loose and improperly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 22 December 2018
Resolution: High Level bilge float switch was properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 December 2018 Resolved
Engine room escape hatch was found difficult to open due to being caught on a bench above the exit.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 22 December 2018
Resolution: Engine room escape hatch was fixed to allow for unobstructed opening and closing.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 29 January 2018 Resolved
Improper connector to battery, replace with non automotive type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 30 January 2018
Resolution: Proper connections have been installed on batteries.
Engineering › Bilge Water Management System › Valve
Issued 29 January 2018 Resolved
Reachrod to valve wasted / inop. Repair replace for proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 30 January 2018
Resolution: Installed reach rod to valve completed, test sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 December 2017 Resolved
Conduct annual inspection prior to carrying passegners.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2017
Resolved 29 January 2018
Resolution: Completed annual inspection.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 September 2015 Resolved
Provide Nav Rules Book.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2015
Resolved 21 September 2015
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 September 2015 Resolved
Provide updated charts for location transited.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2015
Resolved 21 September 2015
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 1 September 2015 Resolved
Mark vehicle deck with traffic lines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2015
Resolved 21 September 2015
Fire Fighting › Fire Main › Condition
Issued 1 September 2015 Resolved
Renew port side fire station vertical deck pipe. Piping is wasted and holed at the base at the penetration through the deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2015
Resolved 21 September 2015
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 1 September 2015 Resolved
Provide proof of radio operators permit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2015
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 1 September 2015 Resolved
Provide a means to properly secure rescue platform at the gunwale.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2015
Resolved 21 September 2015
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 September 2015 Resolved
Provide proof of enrollment in DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 October 2011 Resolved
Renew lazarette high water alarm.
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 3 November 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 October 2011 Resolved
Renew float light battery with approved battery.
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 3 November 2011
Construction/Loadline › Structures › Superstructure
Issued 24 October 2011 Resolved
Crop and renew to good metal port and starboard mooring posts and port mooring cleat. Identify all wastage.
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 3 November 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 October 2011 Resolved
Install bilge high level alarm in the void with the transducer through hull penetration.
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 3 November 2011
Fire Fighting › Fire Hoses › Condition
Issued 26 November 2010 Resolved
Provide fire hose for port side fire hydrant. Current hose leaks at the hydrant/hose connection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2010
Resolution: A new hose was installed. All sat.
Engineering › Reduction Gearing/Clutches › Gear
Issued 6 July 2009 Resolved
Prior to carrying passengers prove proper operation of the main engine gear.
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 10 July 2009
Communications › Public Address System › Loudspeaker
Issued 16 December 2008 Resolved
Provide bullhorn per 46CFR184.610
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 29 December 2008
Resolution: Bullhorn purchased and placed on board.
Navigation › Piloting/Steering › Marine Charts
Issued 16 December 2008 Resolved
Provide updated nautical chart (1998 edition on board and torn).
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 29 December 2008
Resolution: New nautical chart purchased and placed on board.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 December 2008 Resolved
Provide new waterlight battery.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 29 December 2008
Resolution: New waterlight battery purchased and installed.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 16 December 2008 Resolved
Prior to carrying flammable or combustible cargo, provide evidence of a B-V extinguisher or other fire protection as listed in 49CFR176.315.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 2 February 2009
Resolution: Received documentation of B-V extinguisher.
Fire Fighting › Nozzles › Type
Issued 16 December 2008 Resolved
Prior to carrying flammable or combustible cargo, provide a hose nozzle that provides both solid stream and water spray as listed in 49CFR176.315
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 2 February 2009
Resolution: Received documentation of new fire hose nozzle.
Stability › Watertight Integrity › General
Issued 29 October 2007 Resolved
Securing devices for forpeak, #1 void and steering compartments were not in use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2007
Resolved 10 December 2007
Resolution: Securing devices put in place.
Lifesaving › Lifebuoys › Serviceable
Issued 29 October 2007 Resolved
corrosion clip holding water light to ring buoy stuck in open position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2007
Resolved 10 December 2007
Resolution: New corrosion clip for water light in place.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 October 2007 Resolved
Bracket holding portable extinguisher to the wall became loose in the pilot house and does not hold extinguisher to the wall. Extinguisher was found on the deck of the pilot house. Bracket needs to be remounted to the wall
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 December 2007
Resolved 10 December 2007
Resolution: Extinguisher remounted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 January 2006 Resolved
Properly install battery under console.
Action required: 705 - Other - as specified
Resolved 2 October 2006
Resolution: Battery properly installed and witnessed by attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2006 Resolved
Provide proper termination of electric wires under console.
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 2 October 2006
Resolution: Electric wires under console properly terminated as witnessed by attending marine inspector.
Documentation › Certificates/Documents › Stability Letter
Issued 25 January 2006 Resolved
Prove proper stability with 2.44 long tons removed from the forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2006
Resolved 24 October 2006
Resolution: New stability letter issued by MSC 10 October 2006
Fire Fighting › Fire Pumps › Arrangement
Issued 25 January 2006 Resolved
Prove proper operation of fire/bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2006
Resolution: Bilge/Fire pump tested sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 June 2004 Resolved
Address the hanging light fixture
Due 1 July 2004
Resolved 1 July 2004
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 June 2004 Resolved
Retrofit new reflective tape on the specified life jackets
Due 1 July 2004
Resolved 1 July 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 10 June 2004 Resolved
Repair the cracked window on the bridge
Due 1 July 2004
Resolved 1 July 2004
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 10 June 2004 Resolved
Attach the anchor to the anchor line
Due 1 July 2004
Resolved 1 July 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 June 2004 Resolved
Attach the life light through the life ring not just the line.
Due 1 July 2004
Resolved 1 July 2004
Deck/Cargo
Issued 29 July 2002 Resolved
Reconfigure bow and stern net closures so that there are no openings greater than 4". Provide line with "No Passengers permitted Beyond This Point" sign.
Due 28 March 2003
Resolved 28 March 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 July 2002 Resolved
Provide guards on front of generator and main engine.
Due 17 August 2002
Resolved 31 October 2002
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 February 2002 Resolved
Relocate battery from wheelhouse to outside wheelhouse
Condition: Improper Installation
Due 28 February 2002
Resolved 28 February 2002
Communications › Internal Communications System › Portable Radios
Issued 12 February 2002 Resolved
Provide two hand held radios for comms between engineroom and wheelhouse.
Condition: Unknown
Due 28 February 2002
Resolved 28 February 2002
Unknown
Issued 15 February 2001 Resolved
PROVIDE UPDATED CHARTS (46CFR 184.420).
Condition: Unknown
Due 15 March 2001
Resolved 23 March 2001
Unknown
Issued 15 February 2001 Resolved
PROVIDE COMPANY POLICY FOR PASSENGER COUNT RECORDS WHEN NO ONE IS IN THE OFFICE. (46CFR 185.504)
Condition: Unknown
Due 15 March 2001
Resolved 23 March 2001
Unknown
Issued 15 February 2001 Resolved
PROVIDE BILGE ALARM FOR AFT STEERING COMPARTMENT (46CFR 182.520)
Condition: Unknown
Due 15 March 2001
Resolved 23 March 2001
Unknown
Issued 15 February 2001 Resolved
PROVIDE PORTABLE BILGE PUMP IAW 46CFR 182.520(b.
Condition: Unknown
Due 15 March 2001
Resolved 23 March 2001
Unknown
Issued 15 February 2001 Resolved
PROVIDE CURRENT TRAINING AND LIFESAVING EQUIPMENT LOGS IAW 46CFR 185.420/702
Condition: Unknown
Due 15 March 2001
Resolved 23 March 2001
Lifesaving
Issued 20 February 1998 Resolved
CONDUCT UNDERWAY OPERATIONAL TEST OF THE VESSEL INCLUDING EMERGENCY DRILLS.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Engineering
Issued 27 January 1998 Resolved
Provide proof of repairs (mechanic's report) to the main diesel engine blower prior to carrying passengers for hire. _x001C_
Condition: Unknown
Due 27 January 1998
Resolved 27 January 1998
Lifesaving
Issued 18 February 1997 Resolved
CONDUCT U/W DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Lifesaving
Issued 18 February 1997 Resolved
CONDUCT AND LOG DRILLS/TRAINING IAW THE REQUIREMENTS OF 46 CFR 185.520 AND 185.524.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Unknown
Issued 18 February 1997 Resolved
PROVIDE A FIRST AID KIT IAW 46 CFR 184.710 WITH CONTENTS AS SHOWN IN 46 CFRTABLE 160.041-4(b).
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Documentation
Issued 18 February 1997 Resolved
PROVIDE PROOF OF CREW ENROLLMENT IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Lifesaving
Issued 22 February 1996 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 24 May 1996
Resolved 23 May 1996
Lifesaving
Issued 22 February 1995 Resolved
INSTALL LIFE JACKET DONNING PLACARDS IN THE PASSENGER SPACES
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Documentation
Issued 22 February 1995 Resolved
PROVIDE A COPY OF THE FCC STATION LICENSE AND THE FCC RADIO TELEPHONY CERTIFICATE
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Construction/Loadline
Issued 22 February 1995 Resolved
REMOVE OIL IN THE BILGE IN THE MACHINERY SPACE
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Documentation
Issued 22 February 1995 Resolved
PROVIDE COPY OF DOCUMENTATED EVIDENCE OF ENROLLMENT IN A DRUG TESTING PROGRAM
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Construction/Loadline
Issued 22 February 1995 Resolved
PROVIDE 5 GPM HAND BILGE/FIRE PUMP
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Engineering
Issued 22 February 1995 Resolved
INSTALL BELT GUARD ON THE MAIN ENGINE ALTERNATOR
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Construction/Loadline
Issued 7 August 1986 Resolved
MAKE WATERTIGHT BULKHEAD FORWARD OF MAIN ENGINE AVAILABLE FOR HOSE TEST OF INSERT WHERE REMOVED FOR REPAIR OF MAIN ENGINE.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Engineering
Issued 7 August 1986 Resolved
PROVE OPERATION OF MAIN ENGINE UPON COMPLETION OF REPAIRS.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Unknown
Issued 9 July 1986 Resolved
SECURE ACCESS TO NEW WOOD CABIN. NO PASSENGERS MAY BE CARRIED IN THAT CABIN UNTIL SUCH TIME AS CONSTRUCTION IS COMPLETED AND APPROVED BY [name withheld], RI AND EXAMINED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 July 1986
Resolved 9 July 1986
Deck/Cargo
Issued 4 March 1986 Resolved
PROVIDE GUARD ON AFT RAMP CABLE DRUM.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Unknown
Issued 4 March 1986 Resolved
TOTAL PERSONS AND VEHICLES ALLOWED ARE LIMITED TO THE FOLLOWING, PENDING COMPLETION OF STABILITY ANALYSIS: 1. NOT MORE THAN FIFTY (50) TOTAL PERSONS2. ONE (1) SEMI-TRACTOR/TRAILER, OR 3. TWO (2) VAN BODY TRUCKS, OR 4. SEVEN (7) PASSENGER CARS.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Documentation
Issued 4 March 1986 Resolved
SUBMIT DECK VEHICLE/PASSENGER LOADING PLAN TO [name withheld] AND APPROVAL.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986

Casualty record · 2

4 January 2014Routine · role: Involved in a Marine Casualty · activity 4780648
25 November 2018Routine · role: Involved in a Marine Casualty · activity 6589125
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PRUDENCE FERRY (2014–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.