Records from 2014 to 2026. Most recent: inspection, 24 April 2026.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2025
Resolved
Firehose bracket holders are wasted, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 15 August 2025
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 August 2025
Resolved
Ships whistle not in compliance with minimum dB level, must be repaired or replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 17 October 2025
Resolution: horn replaced.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 14 August 2025
No resolution recorded
Vessel has several cracked windows. Make safe until replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025 — due date passed with no resolution recorded
Resolution: Windows are custom design, have been measured & ordered, def extended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2025
Resolved
Engineroom air receiver pressure relief valve leaks, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2025
Resolved 17 October 2025
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025
Resolved
Engineroom dead-end wiring must be removed or properly terminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 21 January 2025
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025
Resolved
Main batteries must be chocked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 21 January 2025
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 January 2025
Resolved
Freeboard measuring tool must aboard the vessel and available to the crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 25 March 2025
Resolution: approved tool has been fabricated, installed on vessel and is readily available for the crew.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 January 2025
Resolved
emergency fuel shut-off must be properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 16 January 2025
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 January 2025
Resolved
MDE exhaust lagging requires tightening &/or replacing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2025
Resolved 21 January 2025
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 September 2024
Resolved
Pin hole leak discovered in fuel tank void aft most bays on stbd side of keel. Vessel is not authorized to operate commercially until repairs have been completed to the satisfaction of the cognizant OCMI/attending Marine Inspector. A one-time transit will be allowed pending approval of submitted emergency drydocking and transit plan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2024
Resolved 10 December 2024
Resolution: repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2022
Resolved
All ferry vessels less than 65ft must be provided with one fixed power bilge pump with a capacity of 25 gallons per minute and one portable hand pump with a minimum capacity of 5 gallons per minute. No portable hand pump onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2022
Resolution: Obtained a portable hand pump which is now onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 November 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate high water. The indicator light for the engine room and lazarette do not work. The panel is also mislabeled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2022
Resolution: Witnessed video of all 3 high water alarm lights working properly. The panel has also been relabeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2022
Resolved
An adult life jacket must be provided for each person carried onboard a vessel. 151 adult lifejackets are required but only 148 adult lifejackets are onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2022
Resolution: Obtained 3 new lifejackets which are properly marked and are onboard the vessel.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 29 November 2022
Resolved
Each vessel less than 65ft must be equipped with a public address system which can be a fixed PA system or a battery powered bullhorn if audible in all accommodation spaces and batteries are continually maintained at a fully charged level. PA system onboard does not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 13 December 2022
Resolution: PA system has been repaired and is audible in the passenger cabins.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 November 2022
Resolved
Each vessel must carry an approved first aid kit or a kit with equivalent contents and instructions. Medicine in first aid kit is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 13 December 2022
Resolution: New aspirin has been placed in first aid kit.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 November 2022
Resolved
A marine employer whose vessel is involved in a casualty shall ensure drug and alcohol testing can be completed within the required timeframe. Alcohol testing must be conducted within 2 hours. No alcohol swabs are onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2022
Resolved 13 December 2022
Resolution: Obtained new alcohol test strips and placed them onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 December 2021
Resolved
All machinery shall be maintained in a manner to protect against fire. Lube and gear oil gage lines for the main engine are chaffing and present a fire hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2021
Resolution: Replaced worn lines, remounted and added chafe protection to new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 December 2021
Resolved
A vessel on a lakes, bays and sounds route must carry three red hand flare distress signals and three orange smoke signals. Vessel does not have flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2021
Resolution: Obtained flares and placed them on the vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 December 2021
Resolved
A visual alarm must be provided at the operating station to indicate a high water level. Panel is not marked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2021
Resolution: Marked the high water alarm panel with names of spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 December 2021
Resolved
Flexible or portable cords cannot be used for permanently installed wiring. Vessel has an extension cord mounted in each passenger cabin space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2021
Resolved 29 December 2021
Resolution: The extension cord in each passenger space has been removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 December 2021
Resolved
Vessels carrying vehicles must have suitable barriers installed at the ends of vehicle runways. Vessel cargo nets are not tight and need a 3rd line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2021
Resolved 27 December 2021
Resolution: Added a third line and tightened the nets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2021
Resolved
Each vessel shall be provided with safe and readily available fire fighting equipment to extinguish any fires likely to be encountered. Vessel cannot secure ventilation to the engine room space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 2 February 2022
Resolution: Vent covers have been fabricated for the engine room ventilation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2020
Resolved
For each 21,000 gal or part thereof of any flammable or combustible liquid being transported on board there must be provided at least one B-V (100 pound) dry chemical fire extinguisher. Vessel does not have a B-V fire extinguisher. Vessel restricted from carrying flammable or combustible liquids.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 7 October 2020
Resolution: 125 LB ABC Dry Chemical Extinguisher procured. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2020
Resolved
All vessels of 26' and over shall be provided with individual bilge lines. Bilge piping for #3 void and laz appears to be partially clogged. Make repairs and retest to satisfaction of attending MI. 46 CFR 182.25-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2020
Resolution: Piping and strainers unclogged. System tested. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 September 2020
Resolved
All vessels must be equipped with NAV lights that are compliance with NAV RULES. STBD NAV light is inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2020
Resolution: STBD Nav light operational. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2020
Resolved
Each child life jacket must be stowed in a location that is marked and separated from adult life jackets. Child life jackets on port side not separated and stowage not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 1 October 2020
Resolution: Life jackets separated and marked. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 September 2020
Resolved
Vessel shall be equipped with suitable portable battery lights. Only one rechargeable flash light on board and battery was dead. Recharge light and procure additional light for pilot house. 46 CFR 180.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: Two flash lights provided. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2020
Resolved
All wiring and cables shall be suitable for marine service and for particular installation used. Port NAV light cable insulation deteriorated. Replace cable. Port fwd flood light cable damage. Replace cable. 46 CFR 183.10-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: New wire installed on port Nav light and port flood light. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 September 2020
Resolved
Each hatch exposed to the weather must have a securing device and be attached by hinge, captive chains, or other device to prevent loss. Three hatches on deck are not secured. Install securing device.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 October 2020
Resolved 29 September 2020
Resolution: Captive chains installed. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 September 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit missing content.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: New first-aid kit procured. All sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 16 December 2019
Resolved
A visual and audible alarm must be provided a the operating station. Compartment #3 visual indicator is inoperable. Repair/replace. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 6 January 2020
Resolution: Indicator repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2019
Resolved
One length of fire hose shall be provided for each fire hydrant. Port side hose is unserviceable. Replace.
46 CFR 181.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: New fire hose was purchased.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 December 2019
Resolved
Where at least monthly manual inspections are conducted,
the date the manual inspection was performed and
the initials of the person performing the inspection shall be recorded. Monthly checks not being recorded. Record monthly checks. NFPA 10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 17 December 2019
Resolution: Maintenance completed and portable extinguishers added to monthly preventative maintenance checklist.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 December 2019
Resolved
The bilge pipe piercing the collision bulkhead must be fitted with screw-down valve and must be operable from above the weather deck. Tool missing to operate valve. Replace tool.
46 CFR 182.25-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: New tool provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 December 2019
Resolved
As appropriate for intended route, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot and Light List. Extracts from publications may be provided instead of complete publication. Vessel has out-of-date charts and missing Coast Pilot and Light List. Provide publications.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: Publications provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 December 2019
Resolved
Each hatch exposed to the weather must have a securing
device. Hatches on deck missing securing device.
46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: Securing device installed on each hatch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 December 2019
Resolved
The master or person in charge shall ensure that the ship is not operate unless a garbage management plan is on the ship. No management plan on board. Provide plan. 33 CFR 151.57
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 17 December 2019
Resolution: Garbage management plan provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2019
Resolved
All electrical equipment exposed to the weather must be watertight. Junction box fwd of generator has lose connections. Flood light on port side fwd of wheel house has exposed wires. Wires for port side light has exposed wires and connections do not terminate in junction box. Wires in engine room not properly secured for stbd nav light and for heater located on port side passenger area. Wires engine room for stbd nav lights do not terminate in junction box. Repair all listed items. 46 CFR 183
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2019
Resolved 3 January 2020
Resolution: All electrical defs were resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018
Resolved
Bilge Pump check valves for forepeak, void space 1, void space 2, and laz were found installed incorrectly (backwards). Prove proper operation of the bilge pump prior to movement. Operator fixed on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Operator fixed on the spot. Operator removed bilge manifold and installed check valves correctly. Proved proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018
Resolved
Bilge pickup in laz was found missing. Replace bilge pickup prior to movement.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 December 2018
Resolved 17 December 2018
Resolution: Bilge pickup in laz was found missing. Operator installed a bilge pickup.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018
Resolved
Strainer basket for bilge pickup in laz was found missing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 22 December 2018
Resolution: Strainer basked for bilge pickup in laz was properly installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2018
Resolved
High level bilge float switch was found loose and improperly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 22 December 2018
Resolution: High Level bilge float switch was properly secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 December 2018
Resolved
Engine room escape hatch was found difficult to open due to being caught on a bench above the exit.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2018
Resolved 22 December 2018
Resolution: Engine room escape hatch was fixed to allow for unobstructed opening and closing.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 29 January 2018
Resolved
Improper connector to battery, replace with non automotive type connectors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 30 January 2018
Resolution: Proper connections have been installed on batteries.
Engineering › Bilge Water Management System › Valve
Issued 29 January 2018
Resolved
Reachrod to valve wasted / inop. Repair replace for proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 30 January 2018
Resolution: Installed reach rod to valve completed, test sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 December 2017
Resolved
Conduct annual inspection prior to carrying passegners.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2017
Resolved 29 January 2018
Resolution: Completed annual inspection.