MAURY USCG vessel records
← All vessels

SANTIAGO PEARL

Built
1985
Last inspected
17 April 2018
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 April 2018
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8309713
262313
Flag
BELIZE
Maury page id
psix-262313

Documentation record

Tonnage as PSIX records it12649 - Convention (Subpart B), Net Ton
42884 - Dead Weight, Metric Ton
53851 - Displacement, Metric Ton
27818 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

17 April 2018 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6392587
17 February 2018 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6357038
17 February 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6357743
11 February 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6380452
8 February 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6351974
26 October 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6294168
25 September 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6276629
22 September 2017 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6267260
15 June 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6176927
24 February 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6088826
23 February 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6093479
23 February 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6094210
2 January 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6064630
10 November 2016 COE-Dockside · COE-Administrative
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6035452
9 November 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6038624
6 August 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5963822
6 August 2016 Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5966195
6 May 2016 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5870310

Deficiency record · 5

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 April 2018 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. Smoke detector above main diesel engine inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2018
Resolution: Class report stated that the repair was made and tested for functionality.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 17 February 2018 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one fo the essential auxiliaries becomes inoperative. Vessel lost propulsion while underway (outbound) due to a leak in the start air system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 February 2018
Resolved 18 February 2018
Resolution: Recieved class report from NKK stating damaged gasket was replaced and main engine operated properly in the presence of surveyor.
Construction/Loadline › Structures › Superstructure
Issued 22 September 2017 Resolved
Efficient guardrails or bullwarks shall be fitted to all exposed parts of the freeboard and superstructure deckss. Guardrail is broken portside near cargo hold #2 aft and starboardside near cargo hold #3 aft. Current dangerous cargo does not authorize welding.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 October 2017
Resolution: Guardrails repaired and welded to the satisfaction of attending Coast Guard Inspector.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 22 September 2017 Resolved
fireman's outfit protective clothing of material to protect skin from the heat radiating from the fire and from scalding steam burns. Found 02 firesuits in satisfactory condition and 02 firesuits in need of replacement due to chafe under armpits and in crouch. 04 complete sets needed for satisfactory rectification due to dangerous cargo aboard.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2017
Resolution: Two new fire fighting outfits were purchased to replace wasted outfit and provide a spare.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 6 August 2016 Resolved
Bridge propulsion control was limited to FULL and STOP while going AHEAD. Local control in engine room had full control of propulsion.
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 9 November 2016
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.

Ownership record